• Title/Summary/Keyword: Sediment oxygen demand

Search Result 118, Processing Time 0.027 seconds

The Policy Review and Water Quality Characteristics of National Fishing Harbors and Designated Ports in East Coast of Korea (동해안 국가어항과 지정항만의 수질특성 및 정책적 고찰)

  • Lee, Dae-In;Kim, Gui-Young;Moon, Ju-Hoon;Eom, Ki-Hyuk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.4
    • /
    • pp.213-223
    • /
    • 2011
  • The status and changes of water quality of national fishing harbors and designated ports in East Coast of Korea were analyzed to support establishment effective water environmental management. COD (Chemical Oxygen Demand) concentration was satisfied to designated water quality criteria in most areas, but TN (Total Nitrogen) and TP (Total Phosphorus) exceeded the criteria frequently. Also, peak concentration was summer in COD and SS (Suspended Solid), but winter in TP. Eutrophication index of Ganggu and Pohang (old) area were the highest. Pollution index by function of COD, TN, and TP of Ganggu, Pohang, Jumunjin, and Guryongpo was high with gradual increasing recently, on the contrary, that of Samcheok, Imwon, and Chuksan was decreased. Pollution index involving multi-indictors relation to organics and inorganics was necessary for water quality assessment. Designated water quality criteria needed to be improved because the criteria of Jukbyun and Chuksan was applied more strictly compared to the other regions although without difference of environmental characteristics. Furthermore, the criteria notified lately needed to be related to management pollutants from land-based sources. The continuous diagnosis and monitoring on sediment quality within the study area were necessary for prevention of water pollution and eco-friendly disposal of dredged sediment. Especially, monitoring of Designated Ports was implemented partially, however monitoring ratio of National Fishing Har-bors was 7% to whole part. Therefore, systematic and integrated environmental monitoring for ports and harbors with charge of national management was reestablished by strengthening and securing a legal basis.

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

Estimation of Total Allowable Pollutant Loads Using Eco-hydrodynamic Modeling for Water Quality Management on the Southern Coast of Korea (생태계 모델에 의한 총허용 오염부하량 산정을 통한 연안해역의 수질관리)

  • Lee, Dae-In;Kim, Jong-Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.1
    • /
    • pp.29-43
    • /
    • 2007
  • For effective management of water quality on the southern coast of korea, a three-dimensional eco-hydrodynamic model is used to predict water quality in summer and to estimate the reduction rate in pollutant loads that would be required to restore water quality. Under the current environmental conditions, in particular, pollutant loadings to the study area were very high, chemical oxygen demand (COD) exceeded seawater quality criteria to comply with current legislation, and water quality was in a eutrophic condition. Therefore, we estimated reduction rates of current pollutant loads by modeling. The model reproduced reasonably the flow field and water quality of the study area. If the terrestrial COD, inorganic nitrogen and phosphorus loads were reduced by 90%, the water quality criteria of Region A were still not satisfied. However, when the nutrient loads from polluted sediment and land were each reduced by 70% simultaneously, COD and $Chl-{\alpha}$ were restored. When we reduced the input COD and nutrient loads from the Nakdong River by 80%, $Chl-{\alpha}$ and COD of Region B decreased below $10\;{\mu}g\;1^{-1}$ and $2\;mg\;1^{-1}$, respectively. The water quality criteria of Region C were satisfied when we reduced the terrestrial COD and nutrient loads by 70%. Total allowable loadings of COD and inorganic nutrients in each region were determined by multiplying the reduction rates by current pollutant loads. Estimated high reduction rates, although difficult to achieve at the present time under the prevailing environmental conditions, suggest that water pollution is very severe in this study area, and pollutant loads must be reduced within total allowable loads by continuous and long-term management. To achieve the reduction in pollutant loads, sustainable countermeasures are necessary, including the expansion of sewage and wastewater facilities, polluted sediment control and limited land use.

  • PDF

Rhizosphere Enhances Removal of Organic Matter and Nitrogen from River Water in Floodplain Filtration (홍수터 여과를 이용한 하천수의 질소와 유기물 제거에 미치는 근권의 효과)

  • Jeong, Byeong-Ryong;Chung, Jong-Bae;Kim, Seung-Hyun;Lee, Young-Deuk;Cho, Hyun-Jong;Baek, Nam-Joo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.1
    • /
    • pp.8-15
    • /
    • 2003
  • If contaminated river water is sprayed over a floodplain, the microbial processes can simultaneously remove organic matter and nitrogen during the infiltration through the sediment profile. The effect of rhizosphere on the removal of organic matter and nitrogen from contaminated river water was investigated using floodplain lysimeters. River water was sprayed at a rate of $68.0L\;m^{-2}\;d^{-1}$ on the top of the lysimeters with or without weed vegetation on the surface, Concentrations of $NO_3$, $NH_4$ and dissolved oxygen (DO), and chemical oxygen demand (COD) and Eh in water were measured as functions of depth for 4 weeks after the system reached a steady state water flow and biological reactions. A significant reductive-condition for denitrification developed in the 30-cm surface profile of lysimeters with weeds. At a depth of 30 cm, COD and $NO_3$-N concentration decreased to 5.2 and $0.9mg\;L^{-1}$ from the respective influent concentrations of 18.2 and $9.8mg\;L^{-1}$. The removal of $NO_3$ in lysimeters with weeds was significantly higher than in those without weeds. Vegetation on the top was assumed to remove $NO_3$ directly by absorption and to create more favorable conditions for denitrification by supply of organic matter and rapid $O_2$ consumption, In the lysimeters without weeds, further removal of $NO_3$ was limited by the lack of an electron donor, i.e. organic matter. These results suggest that the filtration through native floodplains, which include rhizospheres of vegetation on the surface, can be effective for the treatment of contaminated river water.

Sanitary Characteristics of Seawater and Sediments in Tongyeong Harbor (통영항의 해수 및 저질의 위생학적 특성)

  • Park, Jun-Yong;Kim, hhhYeong-In;Bae, Ki-Sung;Oh, Kwang-Soo;Choi, Jong-Duck
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.367-375
    • /
    • 2010
  • The bacteriological and physiochemical analysis of sea water and sediments in Tongyeong harbor was conducted to evaluate sanitary conditions. The samples were collected at 8 stations established once a month from June, 2008 to May, 2009. During the study period, the range of temperature was from 6.7 to $25.2^{\circ}C$, transparency ranged from 1.2 to 2.6 m, chemical oxygen demand ranged from 1.90 to 2.92 mg/L, dissolved oxygen ranged from 6.2 to 10.5 mg/L, dissolved nitrogen ranged from 0.052 to 0.098 mg/L, phosphate ranged from 0.044 to 0.065 mg/L, respectively. Seafood, if eaten raw, carries the risk of food poisoning. Seafood poisoning is often cause by pathogenic microorganism originating from fecal contamination, such as Salmonella sp., Shigella sp. and norovirus. Fecal coliforms are an important indicator of fecal contamination. Therefore, data on fecal coliform are very important for evaluating the safety of fisheries in coastal areas. So, we investigated the sanitary indicate bacteria. The coliform group and fecal coliform MPN's of sea water in Tongyeong harbor were ranged from < 1.8~22,000/100 mL (GM 164.9 MPN/100 mL) and < 1.8~7,900 MPN/100 mL (GM 33.7 MPN/100 mL), respectively. Total coliform were detected 97.0% in 96 of samples and 68.9% of total coliforms were fecal coliforms. These results similar to another seawater detection ratio of total coloforms and fecal coliforms. The Vibrios was isolated and identified with VITEK system. Four hundred eighty strains that were obtained from sea water samples in Tongyeong harbor Detection ratio Vibrio alginolyticus, 34.2%, Vibrio parahaemolyticus, 13.8%, Vibrio vulnificus 10.0%, and V. mimicus 12.5% respectively. Vibrio cholerae O1, was not detected. During the study period, the ranges of water content, ignition loss, COD, and acid volatile sulfates in sediments in Tongyeoung harbor were 41.0~57.4%, 7.8~10.5%, 6.51~9.30 mg/g, 0.04~0.09 mg/g, respectively. Heavy metals in sediment of Tongyeoung harbor were Cd, $0.10{\pm}0.05$; Cu, $4.79{\pm}8.20$; As, $1.95{\pm}0.17$; Hg, $0.10{\pm}0.07$; $Cr^{6+}$, $0.34{\pm}0.12$; Zn, $125.33{\pm}16.40$; Ni, $16.43{\pm}1.93$ mg/kg.

Estimating Carrying Capacity of Lake Shihwa for Water Quality Management (수질관리를 위한 시화호의 환경용량 산정)

  • Kim, Hyung-Chul;Choi, Woo-Jeung;Lee, Won-Chan;Koo, Jun-Ho;Lee, Pil-Yong;Park, Sung-Eun;Hong, Seok-Jin;Jang, Ju-Hyoung
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.571-581
    • /
    • 2007
  • The mechanism of water pollution in Lake Shihwa, one of highly eutrophicated artificial lakes in Korea, has been studied using a numerical 3D physical-biochemical coupled model. In this study, the model was applied to estimate the contribution of land-based pollutant load to water quality of heavily polluted Lake Shihwa. The chemical oxygen demand(COD) was adopted as an index of the lake water quality, and the spatial distribution of an average COD concentration during the summer from 1999 to 2000 was simulated by the model. The simulated COD showed a good agreement with the observed data. According to reproducibility of COD, the high-est levels between 8 and 9 mg/L were shown at the inner site of the lake with inflow of many rivers and ditches, while the lowest was found to be about 5 mg/L at the southwestern site near to dike gate. In the pre-diction of water quality of Lake Shihwa, COD showed still higher levels than 3 mg/L in case of reduction of 95% for land-based pollutant load. This suggests that the curtailment of land-based pollutant load is not only sufficient but the improvement of sediment quality or the increase of seawater exchange should be considered together to improve a water quality in Lake Shihwa.

Environmental Pollutants in Streams of Andong District and Insect Immune Biomarker (안동지역 하천의 환경오염물질과 곤충면역 생체지표 분석)

  • Ryoo Keon Sang;Ko Seong-Oon;Cho Sunghwan;Lee Hwasung;Kim Yonggyun
    • Korean journal of applied entomology
    • /
    • v.44 no.2
    • /
    • pp.97-108
    • /
    • 2005
  • Samples of water, soil, and sediment were taken from 10 streams near Andong, Korea in May 2004. To assess the degree of environmental pollution of each stream, chemical pollutants such as total notrogen (T-N), total phosphorus (T-P), chemical oxygen demand (COD), heavy metals, organophosphorus pesticides, organochlorine pesticides, and dioxin-like PCB congeners were analyzed by standard process tests or U.S. EPA methods. In addition, biomarkers originated from insect immune systems of beet armyworm, Spodoptera exigua, were used to analysis of the environmental samples. Except Waya-chun stream showing T-N content of 9.12 mg/L, most streams were contaminated with relatively low levels of overall pollutants in terms of T-N, T-P, and COD, compared to their acceptable environmental levels designated by the Ministry of Environment. Contents of Pb and Cd in samples of each stream were much lower than environmentally permissible levels. However, several times higherconcentrations of Pb and Cd were found in locations at Mi-chun, Kilan-chun, and Hyunha-chun streams, in comparison with other streams. Diazinon, parathion, and phenthoate compounds among organophosphorus pesticides were detected as concentrations of 0.19, 0.40, and $1.13\;{\mu}g/g$, respectively, from soil sample collected in the vicinity of Mi-chun stream. On the other hand, 16 organochlorine pesticides and 12 dioxin-like PCB congeners, known as endocrine disrupting chemicals, selected in this study were not found above the limit of detection. Biomarker analyses using insect immune responses indicated that Waya-chun stream was suspected as exposure to environmental pollutants. Limitation and compensation of both environmental analysis techniques are discussed.

The Spatio-temporal Distribution of Organic Matter on the Surface Sediment and Its Origin in Gamak Bay, Korea (가막만 표층퇴적물중 유기물량의 시.공간적 분포 특성)

  • Noh Il-Hyeon;Yoon Yang-Ho;Kim Dae-Il;Park Jong-Sick
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • A field survey on the spatio-temporal distribution characteristics and origins of organic matter in surface sediments was carried out monthly at six stations in Gamak Bay, South Korea from April 2000 to March 2002. The range of ignition loss(IL) was $4.6{\sim}11.6%(7.1{\pm}1.6%)$, while chemical oxygen demand(CODs) ranged from $12.25{\sim}99.26mgO_2/g-dry(30.98{\pm}19.09mgO_2/g-dry)$, acid volatile sulfide(AVS) went from no detection(ND)${\sim}10.29mgS/g-dry(1.02{\pm}0.58mgS/g-dry)$, and phaeopigment was $6.84{\sim}116.18{\mu}g/g-dry(23.72{\pm}21.16{\mu}g/g-dry)$. The ranges of particulate organic carbon(POC) and particulate organic nitrogen(PON) were $5.45{\sim}23.24 mgC/g-dty(10.34{\pm}4.40C\;mgC/g-dry)$ and $0.71{\sim}2.99mgN/g-dry(1.37{\pm}0.58mgN/g-dry)$, respectively. Water content was in the range of $43.1{\sim}77.6%(55.8{\pm}5.6%)$, and mud content(silt+clay) was higher than 95% at all stations. The spatial distribution of organic matter in surface sediments was greatly divided between the northwestern, central and eastern areas, southern entrance area from the distribution characteristic of their organic matters. The concentrations of almost all items were greater at the northwestern and southern entrance area than at the other areas in Gamak Bay. In particular, sedimentary pollution was very serious at the northwestern area, because the area had an excessive supply of organic matter due to aquaculture activity and the inflow of sewage from the land. These materials stayed longer because of the topographical characteristics of such as basin and the anoxic conditions in the bottom seawater environment caused by thermocline in the summer. The tendency of temporal change was most prominently in the period of high-water temperatures than low-water ones at the northwestern and southern entrance areas. On the other hand, the central and eastern areas did not show a regular trend for changing the concentrations of each item but mainly showed a higher tendency during the low-water temperatures. This was observed for all but AVS concentrations which were higher during the period of high-water temperature at all stations. Especially, the central and eastern areas showed a large temporal increase of AVS concentration during those periods of high-water temperature where the concentration of CODs was in excess of $20mgO_2/g-dry$. The results show that the organic matters in surface sediments in Gamak Bay actually originated from autochthonous organic matters with eight or less in average C/N ratio including the organic matters generated by the use of ocean, rather than terrigenous organic matters. However, the formation of autochthonous organic matter was mainly derived from detritus than living phytoplankton, indicated the results of the POC/phaeopigment ratio. In addition, the CODs/IL ratio results demonstrate that the detritus was the product of artificial activities such as dregs feeding and fecal pellets of farm organisms caused by aquaculture activities rather than the dynamic of natural ocean activities.

  • PDF