• Title/Summary/Keyword: Secure Switch

Search Result 28, Processing Time 0.04 seconds

Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment (PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2010
  • The purpose of this study is to examine the structure and heat generation mechanism of low voltage switches used to turn on or off the power supply to an indoor lighting system and investigate how the fixtures and movable contacts of the switches are damaged depending on the types of energy sources in order to secure the judgment base for expected PL disputes. Based on the Korean Standard (KS) testing method for incombustibility, this study applied a general flame to the switch. In addition, current was supplied to the switch using the PCITS (Primary Current Injection Test System). The ambient temperature and humidity were maintained at $22{\pm}2^{\circ}C$ and 40~60% respectively while performing the test. It is thought that the switch generated heat due to a defective connection of the wire and clip, insulation deterioration and defective contact of the movable contact, etc. The surface of the switch damaged by the general flame was uniformly carbonized. When the flame source was removed, the fire on the switch was extinguished naturally. From the result obtained by disassembling the switch carbonized by the general flame, it could be seen that fixtures and movable contacts remained in comparatively good shape but the enclosure, clip support, movable contact, indicating lamp, etc. showed carbonization and discoloration. In the case of the switch damaged by overcurrent, the clip connecting the wires, clip support, etc. showed almost no trace of damage, but the fixtures, movable contact, indicating lamp, etc. were severely carbonized. That is, the sections with high contact resistance were intensively damaged and showed a damage pattern indicating that carbonization progressed from the inside to the outside. Therefore, it is possible to judge the initial energy source by analyzing the characteristics of the carbonization pattern and the metal fixtures of damaged switches.

Wavelength Selective Switch using LCoS Display (LCoS 디스플레이를 이용한 파장선택스위치)

  • Lee, Yong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5288-5293
    • /
    • 2014
  • This paper presents the characterization of the wavelength selective switch using a LCOS display instead of a MEMS device, which is a core technology for the next generation ROADM. We constructed a five-port WSS, and examined the basic characteristics of the WSS, such as the response time, beam steering, insertion loss, and channel isolation. The response time of WSS was 11.6 mS and the beam steering characteristics of LCOS was well performed. The measured insertion loss at 40 channels in the c-band were 5.5~12.7 dB and channel isolation was 16~18 dB. Although the characteristics of LCOS-based WSS are inferior to the conventional MEMS-based WSS, it can be improved by additional experiments that secure the technology competitiveness.

The development of industrial secure L2 switch and introduction example for management and security improvement of supervisory control network in purification plant (정수장 감시제어망의 관리와 보안개선을 위한 산업용 보안 L2스위치 개발 및 적용사례)

  • Kim, Yunha;Yu, Chool;Oh, Eun;Kim, Chanmoon;Park, Ikdong;Kim, Yongseong;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.329-339
    • /
    • 2019
  • Recently, the advancement of information and communication technology(ICT) is expanding the connectivity through Internet of Things(IoT), and the media of connection is also expanding from wire/cable transmission to broadband wireless communication, which has significantly improved mobility. This hyperconnectivity has become a key element of the fourth industrial revolution, whereas the supervisory control network of purification plants in korea is operated as a communication network separated from the outside, thereby lagging in terms of connectivity. This is considered the best way to ensure security, and thus there is hardly any consideration of establishing alternatives to operate an efficient and stable communication network. Moreover, security for management of a commercialized communication network and network management solution may be accompanied by immense costs, making it more difficult to make new attempts. Therefore, to improve the conditions for the current supervisory control network of purification plants, this study developed a industrial security L2 switch that supports modbus TCP(Transmission Control Protocol) communication and encryption function of the transmission section. As a result, the communication security performance improved significantly, and the cost for implementing the network management system using Historical Trend and information of HMI(Human Machine Interface) could be reduced by approximately KRW 200 million. The results of this study may be applied to systems for gas, electricity and social safety nets that are infrastructure communication networks that are similar to purification plants.

An Efficient Kernel Introspection System using a Secure Timer on TrustZone (TrustZone의 시큐어 타이머를 이용한 효율적인 커널 검사 시스템)

  • Kim, Jinmok;Kim, Donguk;Park, Jinbum;Kim, Jihoon;Kim, Hyoungshick
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.4
    • /
    • pp.863-872
    • /
    • 2015
  • Kernel rootkit is recognized as one of the most severe and widespread threats to corrupt the integrity of an operating system. Without an external monitor as a root of trust, it is not easy to detect kernel rootkits which can intercept and modify communications at the interfaces between operating system components. To provide such a monitor isolated from an operating system that can be compromised, most existing solutions are based on external hardware. Unlike those solutions, we develop a kernel introspection system based on the ARM TrustZone technology without incurring extra hardware cost, which can provide a secure memory space in isolation from the rest of the system. We particularly use a secure timer to implement an autonomous switch between secure and non-secure modes. To ensure integrity of reference, this system measured reference from vmlinux which is a kernel original image. In addition, the flexibility of monitoring block size can be configured for efficient kernel introspection system. The experimental results show that a secure kernel introspection system is provided without incurring any significant performance penalty (maximum 6% decrease in execution time compared with the normal operating system).

Loop Current Calculation based on Voltage Angle Difference at Tie Switch for Switching Plan Validation in Distribution System Operation (상시개방점 양단전압 측정값을 이용한 배전선로 루프운전 가능 여부 판단 방법)

  • Son, Juhwan;Lim, Seongil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.14-21
    • /
    • 2015
  • Distribution systems are operated in radial structure, but temporal loop structure could be founded the live load transfer. Main purposes of reconfiguration of distribution network are load balancing, loss minimization and voltage drop maintaining. In the loop structure, huge loop current can be flowed between two substations in case of large voltage angle difference. Protection devices of distribution line can be triped by this huge loop current. So, precise calculation of loop current is very important for secure switching. This paper proposes a novel calculation method of loop current using the voltage angle differences measured at the tie switches. Feasibility of the propose method has been verified by various case studies based on Matlab simulation.

Design and Implementation of a Fast DIO(Digital I/O) System (고속 DIO(Digital I/O) 시스템의 설계와 제작)

  • Lee, Jong-Woon;Cho, Gyu-Sang
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.5
    • /
    • pp.229-235
    • /
    • 2006
  • High speed PC-based DIO(Digital I/O) system that consists of a master device and slave I/O devices is developed. The PCI interfaced master device controls all of serial communications, reducing the load on the CPU to a minimum. The slave device is connected from the master device and another slave device is connected to the slave device, it can repeated to maximum 64 slave devices. The slave device has 3 types I/O mode, such as 16 bits input-only, 16 bits output-only, and 8bits input-output. The master device has 2 rings which can take 64 slaves each. Therefore, total I/O points covered by the master is 2048 points. The slave features 3 types of input/output function interchangeability by DIP switch settings. Library, application, and device driver software for the DIO system that have a secure and a convenient functionality are developed.

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

Assessing the adoption potential of a smart greenhouse farming system for tomatoes and strawberries using the TOA-MD model

  • Lee, Won Seok;Kim, Hyun Seok
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.743-752
    • /
    • 2020
  • The purpose of this study was to estimate the economic evaluation of a smart farm investment for tomatoes and strawberries. In addition, the potential adoption rate of the smart farm was derived for different scenarios. This study analyzed the economic evaluation with the net present value (NPV) method and estimated the adoption potential of the smart farm with the trade-off analysis, minimum data (TOA-MD) model. The results were as follows: The analysis of the net present value shows that the smart farm investment for the two crops are economically feasible, and the minimum prices for the tomatoes and strawberries should be 1,179 and 3,797 won/kg to secure a sufficient economic feasibility for the smart farm investment. Next, the analysis of the potential adoption rates for smart farms through the TOA-MD model showed that when the support ratio for the adoption of a smart farm system was 50% and the price increase rates were, respectively, - 5, 2.5, 0, 2.5, and 5%, the conversion rates for tomato farms to switch to smart farms were 0.97, 1.78, 3.05, 4.91, and 7.47%, while the ratios of the strawberry farms to switch to smart farms were 0.12, 0.29, 0.65, 1.33, and 2.53%, respectively. This study has some known limitations, but it provides useful information on decision making about smart farm adoption and can contribute to government policies on smart farms.

Safe Bike : Secure your Bicycle with this smart Arduino based GPS device

  • Godfrey, Daniel;Song, Mi-Hwa
    • International journal of advanced smart convergence
    • /
    • v.5 no.3
    • /
    • pp.16-26
    • /
    • 2016
  • This proposed project is about a bicycle anti theft devised system which helps people protect the bicycle from theft and helps to track the stolen bicycle's location using a smart phone. Safety bike uses two main devices to keep the bicycle secured, the vibration sensor and GPS sensor. The purpose of this project is to put all these small devices into one well connected system which will help the bicycle owner have more control over the security of his own bicycle. The whole system can be divided into two main parts. The first part is about the hardware development whereby all electronics components are connected via the circuit design using wire wrapping technique. This hardware part includes, a vibrations sensor, a GPS receiver, a toggle switch, LED light, Bluetooth and a buzzer. Wireless Bluetooth signals are used as the means of communication between the smartphone and the microcontroller. The second part is the software part which is being to program and control the whole system. The program is written using MikroBasic, a full-featured Basic compiler for microcontroller based systems. In conclusion, this system is designed to enable user to have control in securing his/her bicycle also being able to find and locate it at any time using GPS receiver and mobile android application.

3 Dimensional Electric Field Analysis for 362kv GIS and Analysis on the effect of particle attached on spacer (362kV GIS 차단부 3차원 전계해석 및 스페이서에 부착된 파티클의 영향 분석)

  • Ryu, Sung-Sic;Seok, Bok-Yeol;Lee, Hyeong-Goo;Kim, Yong-Han;Song, Tae-Hun;Choi, Young-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1773-1775
    • /
    • 2003
  • In this Study, the insulation safety for Closing Resistor and Disconnect Switch(DS) of 362kV GIS was estimated through 3 dimensional electric field analysis. In addition, the basic study to secure the electric insulation design technique was carried out through the research on the effect of a metallic particle which is generated in the GIS. As a result of 3 dimensional electric field analysis, it was found that the insulation capability of Closing Resistor and DS of 362kV GIS is stable electrically. Also, the fundamental data to improve the insulation capability of spacer was obtained by analyzing the maximum electric field according to the attached angle of a metallic particle which is attached on the surface of a spacer.

  • PDF