• Title/Summary/Keyword: Sectional Area Curve

Search Result 65, Processing Time 0.026 seconds

An Investigation into Micro Valve Field and Flow Field Characteristic of 7mm Width (7mm폭의 Micro Valve 자장 및 유동특성 고찰)

  • Jeon, Y.S.;Kim, D.S.;Shin, D.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.657-658
    • /
    • 2006
  • Recently, the micro on-off valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for micro valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate micro on-off valve using the analogy of equivalent magnetic circuit and Finite Element Method(FEM) respectively. In case of poppet, flow field characteristic was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D distribution curve of the force by working the front poppet.

  • PDF

Discriminative validity of the timed up and go test for community ambulation in persons with chronic stroke

  • An, Seung Heon;Park, Dae-Sung;Lim, Ji Young
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.4
    • /
    • pp.176-181
    • /
    • 2017
  • Objective: The timed up and go (TUG) test is method used to determine the functional mobility of persons with stroke. Its reliability, validity, reaction rate, fall prediction, and psychological characteristics concerning ambulation ability have been validated. However, the relationship between TUG performance and community ambulation ability is unclear. The purpose of this study was to investigate whether the TUG performance time could indicate community ambulation levels (CAL) differentially in persons with chronic stroke. Design: Cross-sectional study. Methods: Eighty-seven stroke patients had participated in this study. Based on the self-reporting survey results on the difficulties experienced when walking outdoors, the subjects were divided into the independent community ambulation (ICA) group (n=35) and the dependent community ambulation group (n=52). Based on the area under the curve (AUC), the discrimination validity of the TUG performance time was calculated for classifying CAL. The Binomial Logistic Regression Model was utilized to produce the likelihood ratio of selected TUG cut-off values for the distinguishing of community ambulation ability. Results: The selected TUG cut-off values and the area under the curve were <14.87 seconds (AUC=0.871, 95% confidence interval=0.797-0.945), representing a mid-level accuracy. Concerning the likelihood ratio of the selected TUG cut-off value, it was found that the group with TUG performance times shorter than 14.87 seconds showed a 2.889 times higher probability of ICA than those with a TUG score of 14.87 seconds or longer (p<0.05). Conclusions: The TUG can be viewed as an assessment tool that is capable of classifying CAL.

Stratifying Patients with Haematuria into High or Low Risk Groups for Bladder Cancer: a Novel Clinical Scoring System

  • Tan, Guan Hee;Shah, Shamsul Azhar;Ann, Ho Sue;Hemdan, Siti Nurhafizah;Shen, Lim Chun;Abdul Galib, Nurudin Al-Fahmi;Singam, Praveen;Kong, Ho Chee Christopher;Hong, Goh Eng;Bahadzor, Badrulhisham;Zainuddin, Zulkifli Md
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6327-6330
    • /
    • 2013
  • Haematuria is a common presentation of bladder cancer and requires a full urologic evaluation. This study aimed to develop a scoring system capable of stratifying patients with haematuria into high or low risk groups for having bladder cancer to help clinicians decide which patients need more urgent assessment. This cross-sectional study included all adult patients referred for haematuria and subsequently undergoing full urological evaluation in the years 2001 to 2011. Risk factors with strong association with bladder cancer in the study population were used to design the scoring system. Accuracy was determined by the area under the receiver operating characteristic (ROC) curve. A total of 325 patients with haematuria were included, out of which 70 (21.5%) were diagnosed to have bladder cancer. Significant risk factors associated with bladder cancer were male gender, a history of cigarette smoking and the presence of gross haematuria. A scoring system using 4 clinical parameters as variables was created. The scores ranged between 6 to 14, and a score of 10 and above indicated high risk for having bladder cancer. It was found to have good accuracy with an area under the ROC curve of 80.4%, while the sensitivity and specificity were 90.0% and 55.7%, respectively. The scoring system designed in this study has the potential to help clinicians stratify patients who present with haematuria into high or low r isk for having bladder cancer. This will enable high-risk patients to undergo urologic assessment earlier.

Development of an Ejector System for Operation of Chemical Lasers (II) - Optimal Design of the Second-Throat Type Annular Supersonic Ejector - (화학레이저 구동용 이젝터 시스템 개발 (II) - 이차목 형태의 환형 초음속 이젝터 최적 설계 -)

  • Kim Sehoon;Jin Jungkun;Kwon Sejin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1231-1237
    • /
    • 2004
  • Determination of geometric design parameters of a second-throat type annual supersonic ejector is described. Tested geometric parameters were primary nozzle area ratio, cross-sectional area of second-throat, L/D ratio of second-throat and primary flow injection angle. Varying these four geometric parameters, we build a test matrix made of 81 test conditions, and experimental apparatus was fabricated to accommodate them. For each test condition, the stagnation pressure of primary flow and the static pressure of the secondary flow were measured simultaneously along with their transition to steady operation and finally to unstarting condition. Comparing the performance curve of every case focused on starting pressure, the unstarting pressure and the minimum secondary pressure, we could derive correlations that the parameters have on the performance of the ejector and presented the optimal design method of the ejector. Additional experiments were carried out to find effects of temperature and mass flow rate of the secondary flow.

Usefulness of four commonly used neuropathic pain screening questionnaires in patients with chronic low back pain: a cross-sectional study

  • Gudala, Kapil;Ghai, Babita;Bansal, Dipika
    • The Korean Journal of Pain
    • /
    • v.30 no.1
    • /
    • pp.51-58
    • /
    • 2017
  • Background: Recently symptoms-based screening questionnaires have gained attention for screening for a neuropathic pain component (NePC) in various chronic pain conditions. The present study assessed the usefulness of four commonly used NePC screening questionnaires including the Self-completed douleur neuropathique 4 (S-DN4), the ID Pain, the painDETECT questionnaire (PDQ), and the Self-completed Leeds Assessment of neuropathic Symptoms and Signs (S-LANSS) questionnaire in patients with chronic low back pain (CLBP) to assess the presence of NePC. Methods: This is a single-center cross-sectional study where patients with CLBP, with or without leg pain, were included. Participants were initially screened for NePC presence by a physician according to the regular practice, and later assessed using screening questionnaires. The diagnostic accuracy of these questionnaires was compared assuming the physician-made diagnosis as the gold standard. Results: A total of 215 patients with CLBP of which 164 (76.3%, 95% CI, 70.2-81.5) had a NePC were included. S-DN4, ID Pain, and PDQ have an area under the curve (AUC) > 0.8 indicating excellent discrimination. However, S-LANSS has an AUC of 0.69 (0.62-0.75), indicating low discrimination. S-DN4 has a significantly higher AUC as compared to ID Pain (d(AUC) = 0.063, P < 0.01) and S-LANSS (d(AUC) = 0.197, P < 0.01). But the AUC of S-DN4 does not significantly differ from that of PDQ (d(AUC) = 0.013, P = 0.62). Conclusions: S-DN4, ID Pain, and PDQ, but not S-LANSS, have good discriminant validity to screen for NePCs in patients with CLBP. Despite using all the tests, 20-30% of patients with an NePC were missed. Thus, these questionnaires can only be used as an initial clue in screening for NePCs, but do not replace clinical judgment.

Electrophysiological and Mechanical Characteristics in Human Ileal Motility: Recordings of Slow Waves Conductions and Contractions, In vitro

  • Ryoo, Seung-Bum;Oh, Heung-Kwon;Moon, Sang Hui;Choe, Eun Kyung;Yu, Sung A;Park, Sung-Hye;Park, Kyu Joo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.19 no.6
    • /
    • pp.533-542
    • /
    • 2015
  • Little human tissue data are available for slow waves and migrating motor complexes, which are the main components of small bowel motility. We investigated the electrophysiological and mechanical characteristics of human ileal motility, in vitro. Ileum was obtained from patients undergoing bowel resection. Electrophysiological microelectrode recordings for membrane potential changes and mechanical tension recordings for contraction from smooth muscle strips and ileal segments were performed. Drugs affecting the enteric nervous system were applied to measure the changes in activity. Slow waves were detected with a frequency of 9~10/min. There were no cross-sectional differences in resting membrane potential (RMP), amplitude or frequency between outer and inner circular muscle (CM), suggesting that electrical activities could be effectively transmitted from outer to inner CM. The presence of the interstitial cell of Cajal (ICC) at the linia septa was verified by immunohistochemistry. Contractions of strips and segments occurred at a frequency of 3~4/min and 1~2/min, respectively. The frequency, amplitude and area under the curve were similar between CM and LM. In segments, contractions of CM were associated with LM, but propagation varied with antegrade and retrograde directions. Atropine, $N^W$-oxide-L-arginine, and sodium nitroprusside exhibited different effects on RMP and contractions. There were no cross-sectional differences with regard to the characteristics of slow waves in CM. The frequency of contractions in smooth muscle strips and ileal segments was lower than slow waves. The directions of propagation were diverse, indicating both mixing and transport functions of the ileum.

Serum Levels of Interleukin-8 and Tumor Necrosis Factor-alpha in Coal Workers' Pneumoconiosis: One-year Follow-up Study

  • Lee, Jong-Seong;Shin, Jae-Hoon;Lee, Joung-Oh;Lee, Kyung-Myung;Kim, Ji-Hong;Choi, Byung-Soon
    • Safety and Health at Work
    • /
    • v.1 no.1
    • /
    • pp.69-79
    • /
    • 2010
  • Objectives: Various cytokines induced by inhalation of coal dust may mediate inflammation and lead to tissue damage or fibrosis, such as coal workers' pneumoconiosis (CWP). Methods: To investigate the relevance of serum cytokines in CWP, the levels of serum interleukin-8 (IL-8) and tumor necrosis factor-alpha (TNF-${\alpha}$) as CWP biomarkers in 110 retired coal miners (22 controls and 88 CWP subjects) were related to cross sectional findings and 1-year progressive changes of the pneumoconiosis. Progressive changes of CWP were evaluated by paired comparison of chest radiographs. Analysis by a receiver operating characteristic curve assessed the biomarker potential of each cytokine. Results: The mean serum IL-8 level was significantly higher in CWP compared to controls and IL-8 levels correlated with the degree of CWP. The median serum TNF-${\alpha}$ level was significantly higher in subjects with progressive CWP compared to subjects without CWP progression. The area under the ROC curve for IL-8 (0.70) and TNF-${\alpha}$ (0.72) for CWP identification and progression, respectively, indicated the biomarker potential of the two cytokines. Serum cutoff values of IL-8 and TNF-${\alpha}$ were 11.63 pg/mL(sensitivity, 69%; specificity, 64%) and 4.52 pg/mL (sensitivity, 67%; specificity, 79%), respectively. Conclusion: The results suggest that high levels of serum IL-8 are associated with the presence of CWP and those of serum TNF-${\alpha}$ are associated with the progression of CWP.

Secular change in waist circumference and waist-height ratio and optimal cutoff of waist-height ratio for abdominal obesity among Korean children and adolescents over 10 years

  • Kim, Min Sub;Kim, Se Young;Kim, Jae Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.7
    • /
    • pp.261-268
    • /
    • 2019
  • Purpose: This study aimed to evaluate the time trends of waist circumference (WC) and waist-height ratio (WHR), and to present WC and WHR distributions with optimal WHR cutoff for abdominal obesity in Korean children and adolescents. Methods: We performed a retrospective cross-sectional analysis of data from 13,257 children and adolescents (6,987 boys and 6,270 girls) aged 6-18 years who were included in the third to sixth Korea National Health and Nutrition Examination Survey (KNHANES, 2005-2015). Linear regression analyses were used to identify secular changes in WC and WHR by age, sex, and KNHANES waves. A receiver operating characteristic curve analysis was used to determine the optimal WHR cutoff values for abdominal obesity and cardiometabolic risk factors. Results: The mean WC and WHR distributions from 2005 to 2015 showed no significant secular changes between the KNHANES 4 waves (P for trend ${\geq}0.05$ in all ages and both sexes). The mean WCs in the present study were lower than those in the 2007 Korean National Growth Charts. The mean WHR at ages <13 years was statistically higher in the boys than in the girls, but did not significantly differ between the sexes among those aged 13 to 18 years. The optimal WHR cutoff for abdominal obesity was 0.48 (area under the curve, 0.985; 95% confidence interval, 0.985-0.985) in the 13- to 18-year-old adolescents. Conclusion: WC and WHR showed no secular changes over 10 years. The optimal WHR cutoff for abdominal obesity of 0.48 is useful for diagnosing and managing obesity and thus preventing obesity-related cardiometabolic complications in 13- to 18-year-old Korean adolescents.

Validation of a Korean translated version of the Critical Care Pain Observation Tool (CPOT) for ICU patients (중환자 통증사정을 위한 한국어판 Critical care Pain Observation Tool (CPOT)의 신뢰도 및 타당도 검증)

  • Kwak, Eun-Mi;Oh, Hee-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.1
    • /
    • pp.76-84
    • /
    • 2012
  • Purpose: The purpose of this methodological study was to examine the reliability and validity of a translated Korean version of the Critical Care Pain Observation Tool (CPOT) developed for assessment of pain in critically ill nonverbal patients. Methods: A cross-sectional study design was used. Data were collected from a convenience sample of 202 critically ill patients admitted to a university hospital. Upon establishment of content and translation equivalence between the English and Korean version of CPOT, psychometric properties were evaluated. Results: The interrater reliability was found to be acceptable with the weighted kappa coefficients of .81-.88. Significant high correlations between the CPOT and the Checklist of Nonverbal Pain Indicators were found indicating good concurrent validity (r=.72-.83, p<.001). Data showed the area under the ROC curve of 0.86 with a cut-off point of 1, which resulted in 76.9% sensitivity and 88.6% specificity. The mean score of CPOT during suctioning was significantly different from that of before (t= -14.16, p<.001) or 20 minutes after suctioning (t=16.31, p<.001). Conclusion: Results of this study suggest that the CPOT can be used as a reliable and valid measure to assess pain in critically ill nonverbal patients.

Psychometric Properties of Korean Version of Modified Leeds Sleep Evaluation Questionnaire (KMLSEQ)

  • Kim, Inja;Choi, Heejung;Kim, Beomjong
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.17 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • Purpose: The Leeds Sleep Evaluation Questionnaire (LSEQ) translated into Korean was modified to easily apply and reduce respondents' confusion and was evaluated for psychometric properties and discriminant ability. Methods: A total of 960 Korean adults aged 45 years and older participated in this cross-sectional survey. To test reliability, validity and discriminant ability, Cronbach's alpha, correlation analysis, confirmatory factor analysis, simple regression analysis and receiver operating characteristics (ROC) curve analysis were used. Results: Item-total correlations ranged between 62~.85 and Cronbach's alpha was .95. Area under ROC was .86 (95% CI: .83~.90) and the optimal cutoff score was identified as ${\leq}$ 66 (sensitivity, .77; specificity, .84; positive/negative predictive values, .49/.95). Using this cutoff score, the prevalence of insomnia in the study sample was 25.8% and tended to be more common in female and older groups. Conclusion: The data supported the psychometric properties of Korean Modified Leeds Sleep Evaluation Questionnaire (KMLSEQ) as an acceptable sleep measurement. In addition, KMLSEQ is likely to be a useful screening tool for insomnia.