• Title/Summary/Keyword: Section Repair

Search Result 173, Processing Time 0.019 seconds

Reliability of Maintained Hull Girders of Two Bulk Carrier Designs Subjected to Fatigue and Corrosion

  • Soares, C.Guedes;Garbatov, Y.
    • Journal of Ship and Ocean Technology
    • /
    • v.3 no.1
    • /
    • pp.27-41
    • /
    • 1999
  • The objective of the paper is to study the impact of changing the traditional hull design of bulk carriers by providing them with a double hull while keeping the same deadweight. It is demonstrated that by introducing the double hull the structural reliability is increased throughout the entire life and also the extend of the needed repair is reduced. The results are obtained with recently developed mathematical tools for the reliability assessment of ship hulls subjected to the existence of multiple cracks both in the stiffeners and in the plating and it models the crack growth process. The effect of corrosion is represented as time dependent. The long-term stress range acting on the elements is defined as a function of the local transverse pressure of the internal cargo and outside sea water combined with the stresses resulting from the longitudinal bending of the hull, which is a combined with the stresses resulting from the longitudinal bending of the hull, which is a combineation of horizontal and vertical bending moments. The effect of maintenance actions is modelled as a stochastic process. The results show that a different design of the midship section improves the structural safety and also the economy with respect to structural repair of bulk carriers.

  • PDF

Proposal of Repair Method and Pop-out Phenomenon of Concrete Incorporating Electric Arc Furnace Oxidizing Slag Fine Aggregate (전기로 산화 슬래그 잔골재를 사용한 콘크리트의 팝아웃현상 및 보수공법 제안)

  • Lee, Gun-Cheol;Lee, Mun-Hwan;Lee, Sea-Hyun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.65-71
    • /
    • 2007
  • Since pop-outs are occurred recently on concrete surface occasionally, it is needed to find out accurate causes and to suggest appropriate methods. On this study, it is investigated the occurrence mechanism of pop-outs caused by electric arc furnace Oxidizing slags as fine aggregate for concrete. As a result, it is investigated the cause of pop-outs that extremely small quantities of free CaO and free MgO in the electric furnace slag react with water to produce $Ca(OH)_2$ and $Mg(OH)_2$, so that their volumes are expanded and erupted about two times. As a resolution, it is needed to remove the potential cause of expansion by replacing the deteriorated concrete section up to the depth to secure the safe of structural element with repairing polymer mortar, especially more than 50MPa.

  • PDF

Damage of scarf-repaired composite laminates subjected to low-velocity impacts

  • Cheng, Xiaoquan;Zhao, Wenyi;Liu, Shufeng;Xu, Yunyan;Bao, Jianwen
    • Steel and Composite Structures
    • /
    • v.17 no.2
    • /
    • pp.199-213
    • /
    • 2014
  • The damage characters of scarf repaired composite laminates subjected to low-velocity impact with various energy levels at different locations are studied experimentally. The results are compared with those of the original laminates which have no initial damage and don't need repair. The impact load-time history of the specimens, the velocity-time curves of the impactor, the post impact compressive strength of the specimens and the C-scan photographs of the damaged regions are obtained. The delamination threshold load and damage character of the specimen section at impact point are also studied. The results have shown that the impact response of a repaired composite laminate is sensitive to the location of the impact. The impact load and the delamination threshold load have shown different characters for specimens with different impact locations. The debonding characters of the adhesive and compressive strength after impact of the specimens are also influenced by impact locations.

Fistula of the ankle : A complication of ankle sprain (염좌 후에 발생한 족관절 누공)

  • Lee, Woo-Chun;Kim, Jung-Hoon;Song, Jae-Kuk;Moon, Jeong-Seok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.261-264
    • /
    • 2002
  • Purpose: To investigate the clinical features of fistulas of the ankle joints. Materials and Methods: Seven fistulas in seven patients were reviewed during Apr. 2000 to Mar. 2002, retrospectively. There are five men and two wemen. Average age was 47.7 years (range, 42-65 years). Average follow-up period was 1.4 years. There were six cystic lesions after ankle sprain and one patient with persistent discharge after excision of bursa over lateral malleolus. Results: Duration from injury to presentation was average 9.8 years. The site of preoperative swelling was mostly over the lateral malleolus in five patients. In one patient, the area of swelling was extended to the anterolateral ankle joint and in another patient there was extensive swelling from Achilles tendon to the anterolateral ankle joint. Concomitant symptoms were instability in three patients, pain and instability in three patients. Methods of surgery were simple repair in one, modified Brostrom in three, augmentation with periosteal flap in addition to modified Brostrom in two and Chrisman-Snook in addition to augmentation with periosteal flap and modified Brostrom in one. There were no recurrence of instability as well as fistula. Conclusion: We think that the fistula of the ankle joint should be included in the differential diagnosis of the cystic lesion over the lateral malleolus and the result of surgical treatment would be satisfactory in most cases.

  • PDF

Investigation of shear transfer mechanisms in repaired damaged concrete columns strengthened with RC jackets

  • Achillopoulou, D.V;Karabinis, A.I
    • Structural Engineering and Mechanics
    • /
    • v.47 no.4
    • /
    • pp.575-598
    • /
    • 2013
  • The study presents the results of an experimental program concerning the shear force transfer between reinforced concrete (RC) jackets and existing columns with damages. In order to investigate the effectiveness of the repair method applied and the contribution of each shear transfer mechanism of the interface. It includes 22 concrete columns (core) (of 24,37MPa concrete strength) with square section (150mm side, 500 mm height and scale 1:2). Ten columns had initial construction damages and twelve were subjected to initial axial load. Sixteen columns have full jacketing at all four faces with 80mm thickness (of 31,7MPa concrete strength) and contain longitudinal bars (of 500MPa nominal strength) and closed stirrups spaced at 25mm, 50mm or 100mm (of 220MPa nominal strength). Fourteen of them contain dowels at the interface between old and new concrete. All columns were subjected to repeated (pseudo-seismic) axial compression with increasing deformation cycles up to failure with or without jacketing. Two load patterns were selected to examine the difference of the behavior of columns. The effects of the initial damages, of the reinforcement of the interface (dowels) and of the confinement generated by the stirrups are investigated through axial- deformation (slip) diagrams and the energy absorbed diagrams. The results indicate that the initial damages affect the total behavior of the column and the capacity of the interface to shear mechanisms and to slip: a) the maximum bearing load of old column is decreased affecting at the same time the loading capacity of the jacketed element, b) suitable repair of initially damaged specimens increases the capacity of the jacketed column to transfer load through the interface.

A re-route method for reliable data transport in Ad Hoc Networks (Ad Hoc 망에서 신뢰성 있는 데이터 전송을 위한 경로 재설정 기법)

  • 한정안;백종근;김병기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3A
    • /
    • pp.276-287
    • /
    • 2004
  • An ad hoc network is infra(Base Sstation or Access Point) free wireless mobile communication technology. Mobile nodes function as routers and servers in ad hoc networks. Many routing protocols for ad hoc network have been proposed. If any route is broken owing to moving node, source must repair broken route again. But route repair technology after route collapses is not suitable to transmit real-time data packet for QoS guarantee. So this paper presents route repair technology that prevents route from breaking. If intermediate node moves to critical section, the node issues handoff packet and sends the packet to the next node. After next node receives handoff packet, the node broadcasts route request packet to the previous node for intermediate node. Finally, even if intermediate node moves out of the routing region, the source can continuously transmit data packets to the destination through the new path.

The Performance Analysis of Diamond Grinding for Existing Concrete Pavement (기존 콘크리트 포장의 성능 향상을 위한 다이아몬드 그라인딩 공법의 초기 공용성 평가)

  • Jung Jong-Duck;Ryu Sung-Woo;Han Seung-Hwan;Cho Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.8 no.3 s.29
    • /
    • pp.77-88
    • /
    • 2006
  • The maintenance / repair of concrete pavements has become an issue as a result of increasing of concrete pavements' service year. Asphalt overlay is applied to the concrete pavements after partial repairs on all occasions. This thesis discusses the application standard, evenness, skid resistance, noise, economical efficiency, extension of life span, etc. of diamond grinding, a method of maintenance about concrete pavements. Based on this, it was applied to the field and measured the performance. It was measured the longitudinal evenness of before and after the construction through measurement equipment. and surveyed the skid resistance the each lane classified using the SN standard value. In case of noise, it is selected the kind of vehicle, velocity, then measured the noise between control and constructed site. In addition, it is evaluated the average texture depth. As a result of the analysis, longitudinal evenness is improved about $6{\sim}40%$, skid resistance is improved 66% at first section,37% at second section. Noise is reduced 3.4dB average, and average texture depth is 79% deeper than control section. Therefore, it can be concluded that diamond grinding is suitable as maintenance / repair method of concrete pavements.

  • PDF

GUIDED BONE REGENERATION USING $REGENAFORM^{(R)}\;AND\;OSSIX^{(R)}$ MEMBRANE: THREE CASE REPORTS ($Regenaform^{(R)}$$Ossix^{(R)}$ 차단막을 이용한 골유도재생술: 증례보고)

  • Kim, Young-Kyun;Yun, Pil-Young;Lim, Sung-Chul;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.6
    • /
    • pp.648-653
    • /
    • 2007
  • This case study investigated the clinical effect of guided bone regeneration(GBR) using $Regenaform^{(R)}\;and\;Ossix^{(R)}$ membrane and the histology of the new bone that formed just under the membranes. $Regenaform^{(R)}$ transplantation and covering with $Ossix^{(R)}$ membrane were performed to repair bone defects around implants after implantation in three patients. After $3{\sim}4$ months, the membranes were removed in a second operation, and a biopsy was taken under the membrane. The biopsies showed a bone density of $23{\sim}42%$, and subsequent prosthetic treatments were successful in all cases.

CFRP strengthening of steel columns subjected to eccentric compression loading

  • Keykha, Amir Hamzeh
    • Steel and Composite Structures
    • /
    • v.23 no.1
    • /
    • pp.87-94
    • /
    • 2017
  • Steel structures often require strengthening due to the increasing life loads, or repair caused by corrosion or fatigue cracking. Carbon Fiber Reinforced Polymers (CFRP) is one of the materials used to strengthen steel structures. Most studies on strengthening steel structures have been carried out on steel beams and steel columns under centric compression load. No independent article, to the author's knowledge, has studied the effect of CFRP strengthening on steel columns under eccentric compression load, and it seems that there is a lack of understanding on behavior of CFRP strengthening on steel columns under eccentric compression load. However, this study explored the use of adhesively bonded CFRP flexible sheets on retrofitting square hollow section (SHS) steel columns under the eccentric compression load, using numerical investigations. Finite Element Method (FEM) was employed for modeling. To determine ultimate load of SHS steel columns, eight specimens with two types of section (Type A and B), strengthened using CFRP sheets, were analyzed under different coverage lengths, the number of layers, and the location of CFRP composites. Two specimens were analyzed without strengthening (control) to determine the increasing rate of the ultimate load in strengthened steel columns. ANSYS was used to analyze the SHS steel columns. The results showed that the CFRP composite had no similar effect on the slender and stocky SHS steel columns. The results also showed that the coverage length, the number of layers, and the location of CFRP composites were effective in increasing the ultimate load of the SHS steel columns.

Fire performance of concrete-filled steel tubular columns strengthened by CFRP

  • Tao, Zhong;Wang, Zhi-Bin;Han, Lin-Hai;Uy, Brian
    • Steel and Composite Structures
    • /
    • v.11 no.4
    • /
    • pp.307-324
    • /
    • 2011
  • With the increasing use of concrete-filled steel tubes (CFST) as structural members, there is a growing need to provide suitable measures for possible strengthening or repair of these kinds of structural elements. Fibre reinforced polymer (FRP) jacketing is a recent method and is particularly attractive in which it does not significantly increase the section size, and is relatively easy to install. Thus, it can be used to enhance strength and/or ductility of CFST members. Very little information is available on the performance of FRP-strengthened CFST members under fire conditions. This paper is an attempt to study the fire performance of CFST columns strengthened by FRP. The results of fire endurance tests on FRP-strengthened circular CFST columns are presented. Failure modes of the specimens after exposure to fire, temperatures in the cross section, axial deformation and fire resistance of the composite columns are analysed. It is demonstrated that the required fire endurance can be achieved if the strengthened composite columns are appropriately designed.