• 제목/요약/키워드: Secondary Refrigerant

검색결과 34건 처리시간 0.02초

탄화수소 냉매를 사용한 냉방시스템의 성능 및 열전달 특성 (Performance and heat transfer of an air conditioning system filled with hydrocarbon refrigerants)

  • 장영수;김민수;노승탁
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.713-723
    • /
    • 1997
  • Performance and heat transfer characteristics of an air conditioning system filled with hydro- carbon refrigerants are experimentally investigated. Single component hydrocarbon refrigerants (propane, isobutane, butane and propylene) and binary mixtures of propane/isobutane and propane/butane are considered as working fluids in the air conditioning system. Performances of each refrigerant are obtained at several compressor speeds and temperature levels of secondary heat transfer fluids. The cooling capacity and the coefficient of performance are obtained as test results. Heat transfer data of selected refrigerants are achieved from overall conductance measurement. Average heat transfer coefficients at different mass fluxes are shown and they are also displayed for different heat capacities of the system. Experimental results show that some hydrocarbon refrigerants have better characteristics than R22.

R22 대체냉매의 성능 평가 (Performance evaluation of R22 alternative refrigerants)

  • 송용재;박봉진;정동수;김종보
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.292-302
    • /
    • 1998
  • In this study, 14 refrigerant mixtures composed of R32, R125, R134a, R143a, R152a, and R1270(Propylene) were tested in a breadboard heat pump in an attempt to replace R22 used in most of the residential air conditioners and heat pumps. The heat pump was of 1 ton capacity and water was employed as the secondary heat transfer fluids. All tests were conducted under ARI test A condition. Ternary mixtures composed of R32, R125, and R134a were shown to have 4∼5% higher COP and capacity than R22 and hence they seem to be very promising candidates to replace R22. On the other hand, ternary mixtures containing R125, R134a, and R152a have lower COP and capacity than R22. R32/R134a binary mixtures show a 7% increase in COP and have the similar capacity to that of R22 and hence they are also good candidates to replace R22. Special care must be exercised when a suction line heat exchanger is used with these mixtures in air conditioners. Finally, the compressor discharge temperatures of all mixtures tested were lower than those of R22 by 15.g∼34.7t, which indicates that these mixtures would offer better system reliability and longer life time than R22.

  • PDF

자동차 공조기용 R12 및 R134a 대체 냉매의 성능평가 (Performance of Alternative Refrigerants for R12 and R134a in Automobile Air-Conditioners)

  • 백인철;박기정;심윤보;정동수
    • 설비공학논문집
    • /
    • 제19권5호
    • /
    • pp.403-410
    • /
    • 2007
  • In this study, natural refrigerants and their mixtures that can supplement and replace R12 and R134a in automobile air-conditioners are studied. R134a is currently used as the refrigerant in new motor vehicle air conditioners, replacing the ozone depleting refrigerant R12. Although R134a has no ozone depletion potential, it has a relatively large global warming potential, approximately 1300 times that of $CO_2$ over a 100 year time horizon. For this reason, performance of natural refrigerants and their mixtures containing R152a, RE170 (Dimethylether, DME) and R600a (Isobutane) are measured under 2 different temperature conditions. They were tested in a refrigerating bench tester with an open type compressor. The test bench provided about 4 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. Test results show that the coefficient of performance (COP) of these refrigerants is up to 21.55% higher than that of R12 in all temperature conditions. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for automobile air-conditioners.

정사각 덕트 초임계 상태 이산화탄소 가스 냉각과정 중 2차 유동 특성 측정 연구 (Experimental Study on the Secondary Flow Characteristics of a Supercritical Carbon Dioxide Flow in a Gas Cooling Process Within a Square Duct)

  • 한성호;서정식;김용찬;김민수;최영돈
    • 대한기계학회논문집B
    • /
    • 제32권2호
    • /
    • pp.158-165
    • /
    • 2008
  • The carbon dioxide properties change sharply near the critical or pseudo-critical point in the heat transfer processes. The reduction in turbulent, convective heat transfer parameters observed in some supercritical data and in experiments with common gases can be due to property variation, acceleration, buoyancy or combinations of these phenomena, depending on the conditions of the applications. In this study, the measurement for the secondary flow driven by buoyancy was carried out on the supercritical carbon dioxide turbulent flows in the different boundary condition with the constant mass flow rate. The available measuring techniques were used to clarify the behaviour of any supercritical fluid. Laser Doppler Velocimeter (LDV) and a special device was used to measure the secondary velocity and turbulent characteristics of the supercritical flows.

단일유로 멀티사이클 및 바이패스유로 멀티사이클 적용 냉동시스템의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of a Single-Circuit Multi Cycle and a Bypass Two-Circuit Multi Cycle)

  • 송영승;정해원;윤원재;김용찬
    • 설비공학논문집
    • /
    • 제23권7호
    • /
    • pp.513-519
    • /
    • 2011
  • The object of this study is to investigate the performance characteristics of refrigerators using a single-circuit multi cycle and a bypass two-circuit multi cycle. Each refrigeration cycle was tested by varying secondary fluid mass flow rate and temperature. Based on the experimental data, the optimum refrigerant charge was 48 g and the COP at the optimum secondary fluid mass flow rate was 1.53 for the single-circuit multi cycle. For freezer(F)-only mode, both the single-circuit multi cycle and the bypass two-circuit multi cycle were operated at overcharge conditions, resulting in an increase of the secondary fluid mass flow rate. The maximum COPs of the single-circuit multi cycle and the bypass two-circuit multi cycle were 1.22 and 1.35, respectively. The COP increased by 10.7% with the application of the bypass two-circuit multi cycle.

이산화탄소 열펌프 시스템의 퍼지 제어에 관한 연구 (Study on the Fuzzy Control of CO2 Heat Pump System)

  • 이재승;한융희;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.513-518
    • /
    • 2008
  • In the air-conditioning and refrigeration industry, the efforts to protect the environment have been made. One of them is to use carbon dioxide as an alternative refrigerant, however, several researches have shown that the transcritical heat pump system using $CO_2$ has relatively lower efficiency resulting in a degraded steady-state system performance. Capacity control with fuzzy controller was carried out for $CO_2$ heat pump system. Evaporator secondary fluid outlet temperature was suggested for the control variable of compressor speed modulation.

  • PDF

R134a, R152a, R22/142b를 이용한 냉동기의 성능실험 (Performance of Refrigerator Using R134a, R152a and R22/142b)

  • 장영수;신지영;노승탁
    • 설비공학논문집
    • /
    • 제6권1호
    • /
    • pp.39-46
    • /
    • 1994
  • Experiments on the performance of refrigeration system using alternatives to R12 are carried out. The condenser and the evaporator are concentric-tube heat exchangers of counter-flow type and the compressor is driven by a variable speed motor. In this study, R134a, R152a, R22/142b(50 : 50 by mass) are adopted as alternatives to R12. Tests are performed by varying the inlet and outlet temperatures of secondary fluids of evaporator and condenser under the condition of constant compressor speed, degree of superheating and degree of subcooling. Results show that R134a has refrigeration capacity close to that of R12 and requires the greatest compressor power compared with that of others. And the system using R152a shows the best performance from the viewpoint of refrigeration capacity, compressor power and coefficient of performance. R22/142b is superior to R12 in the above points.

  • PDF

R134a 터보 냉동기용 2단 원심 압축기의 수치해석 기법과 내부유동 특성 (Numerical Analysis Techniques and Flow Characteristics of Two-Stage Centrifugal Compressor for R134a Turbo-Chiller)

  • 박한영;오현택;신유환;이윤표;김광호;정진택
    • 한국유체기계학회 논문집
    • /
    • 제10권4호
    • /
    • pp.29-38
    • /
    • 2007
  • In this study, flow structure in a two-stage centrifugal compressor for a turbo-chiller with the refrigerant, R134a, was numerically investigated at the design point of the compressor using a commercial code. Flow characteristics in the passages of impeller, diffuser and return channel were analyzed in detail including velocity vector, secondary flow, Mach number and pressure contours in blade spanwise and meridional plane for each stage. The estimation on the one-dimensional output from the preliminary design and three-dimensional shape of the impeller blade and the meridional shape of the return channel were performed through the flow analysis, while some numerical schemes and techniques including Multiple Frames of Reference technique, real gas property data and inlet boundary condition changes, which were used in CFD, were compared with their features. The results will be used as reference data for a new design of 3-D impeller shape to improve R134a compressor performance.

라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구 (A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter)

  • 민세홍;배연준
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.168-177
    • /
    • 2011
  • 본 연구에서는 현재 상업용으로 가장 많이 사용되고 있는 멀티시스템형 에어컨실외기의 화재 위험성을 평가하기 위하여 에어컨실외기의 실물 연소실험을 수행하였다. 그 결과 에어컨실외기는 내부 폭발과 상부 배출 그릴을 통한 급격한 화염분출 및 화재확산을 보였으며, 이는 실외기 내부에 내장된 전선, 전자 제어판, 열교환용 동판 및 합성수지류 등의 가연물이 연소하고 냉매가스가 충전된 배관이 가열로 인해 파괴되어 냉매가스가 분출되면서 화재폭발과 외부로 화염분출을 가속시켜 일어난 것이다. 본 실험에서 에어컨실외기의 최고 열방출율은 5,830 kW로 나타났으며, 열화상 카메라 및 열전대에 의해 측정된 실외기의 내부 온도는 최고 $1,201^{\circ}C$이고, 외부온도는 최고 $881^{\circ}C$ 이상, 화염의 길이는 약 5 m 이상 상승하였다. 그러므로 에어컨실외기의 화재는 주변 가연물을 발화시키는 원인으로 작용하여 건축물에 2차 화재를 발생시킴으로써 큰 피해를 줄 수 있을 것으로 판단된다. 이러한 실물실험에서 얻어낸 결과는 향후 컴퓨터시뮬레이션에서 에어컨실외기의 화재구현 및 주변 가연물로의 화재 확산 예측에 적용될 수 있을 것이다.

아이스슬러리형 축냉시스템을 이용한 쇼케이스 냉각장치의 열적성능에 관한 실험적 연구 (Thermal Performance of the Show-Case Cooler Using Ice Slurry Type Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.26-29
    • /
    • 2011
  • 일반적인 냉각 과정에 적용되는 이차 냉매로서 아이스슬러리 적용 기술이 최근 개발되고 있다. 아이스슬러리는 액체와 거의 동일한 특성을 가지고 있고, 단위 체적당 아이스슬러리의 에너지용량이 얼음 입자의 잠열로 인해 냉각수나 브라인에 비해 상당히 높지만 파이프를 통해서 잘 유동시킬 수 있다. 아이스슬러리를 적용하는 냉각시스템의 설계를 위한 기초 결과를 제시하기 위하여, 쇼케이스의 냉각 코일에 아이스슬러리를 적용하는 실험을 수행하였다. 냉각 코일 입구에서의 아이스슬러리의 온도가 R22에 비하여 적어도 $5^{\circ}C$ 정도 높지만, R22를 적용하는 냉각시스템에 비하여 동등한 열적 성능을 가지고 있었다.