• Title/Summary/Keyword: Second voltage

Search Result 734, Processing Time 0.039 seconds

Sliding Mode Control of a New Wind-Based Isolated Three-Phase Induction Generator System with Constant Frequency and Adjustable Output Voltage

  • Moradian, Mohammadreza;Soltani, Jafar
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.675-684
    • /
    • 2016
  • This paper presents a new stand-alone wind-based induction generator system with constant frequency and adjustable output voltage. The proposed generator consists of a six-phase cage-rotor induction machine with two separate three-phase balanced stator windings and a three-phase space vector pulse width modulation inverter that operates as a static synchronous compensator (STATCOM). The first stator winding is fed by the STATCOM and used to excite the machine while the second stator winding is connected to the generator external load. The main frequency of the STATCOM is determined to be constant and equal to the load-requested frequency. The generator output frequency is independent of the load power demand and its prime mover speed because the frequency of the induced emf in the second stator winding is the same as this constant frequency. A sliding mode control (SMC) is developed to regulate the generator output voltage. A second SMC is used to force the zero active power exchanged between the machine and the STATCOM. Some simulation and experimental results are presented to prove the validity and effectiveness of the proposed generator system.

Numerical Algorithm for Power Transformer Protection

  • Park, Chul-Won;Suh, Hee-Seok;Shin, Myong-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.3
    • /
    • pp.146-151
    • /
    • 2004
  • The most widely used primary protection for the internal fault detection of the power transformer is current ratio differential relaying (CRDR) with harmonic restraint. However, the second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic restraint CRDR must be modified. This paper proposes a numerical algorithm for enhanced power transformer protection. This algorithm enables a clear distinction regarding internal faults as well as magnetizing inrush and steady state. It does this by analyzing the RMS fluctuation of terminal voltage, instantaneous value of the differential current, RMS changes, harmonic component analysis of differential current, and analysis of flux-differential slope characteristics. Based on the results of testing with WatATP99 simulation data, the proposed algorithm demonstrated more rapid and reliable performance.

Advanced Numerical Relaying for Power Transformer Protection (전력용변압기보호를 위한 개선된 수치계전기법)

  • Park, Chul-Won;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.217-219
    • /
    • 2004
  • The second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic-restrained RDR needs modification. This paper describes an advanced numerical algorithm that utilizes terminal voltage, differential current harmonics, harmonic ratio, and flux-differential current slope. Based on the results of testing with WatATP99 simulation data, the proposed algorithm was proven to be faster and more reliable.

  • PDF

STUDY ON THE REAL TIME VOLTAGE-REACTIVE POWER CONTROL USING THE FUZZY THEORY (FUZZY 이론을 이용한 전압.무효전력의 순서제어에 관한 연구)

  • Song, K.Y.;Kim, S.Y.;Cho, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.231-234
    • /
    • 1990
  • This paper shows real-time control technique of voltage-reactive power using the fuzzy theory. Here, major benefits of applying the fuzzy set theory as follow. First, heuristic knowledge of operator has been used in the operation and control of power system. Second, difficulties in traditional multi-objective numerical solution methods have been solved. Also, to achieve optimizing process on the voltage-reactive power control conventional search method have been used.

  • PDF

Design for High Voltage Generator of Electron Beam Manufacturing System (전자빔 가공기를 위한 고전압 발생 장치 설계)

  • 임선종;강재훈;이찬홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.564-567
    • /
    • 2004
  • In the manufacture of integrated circuits, photolithography is the lowest yield step in present production lines. Electron beams form a powerful set of tools with which to attack this problem. Electron beams can be used to make patterns that are smaller than can a photolithography. We design a high voltage generator of electron beam manufacturing system. For this purpose, first, the configuration of electron beam manufacturing system was analyzed. Second, the basic configuration of a high voltage generator and test results were presented.

  • PDF

1MVA synchronous generator control for vessel used for digital AVR of drop method (Drop 방식의 디지털 AVR을 이용한 1MVA급 선박용 동기발전기 제어)

  • Yoo, Dong-Hwan;Hwang, Chun-Hwan;Park, Sang-Hoon;Yoo, Jae-Sung;Lee, Sang-Suk;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.225-229
    • /
    • 2007
  • The output voltage of a synchronous generator is regulated constantly by field current control of excitation system. Synchronous generator exciter has two type, first one is Drop control type by thyristor and second one is exciter current control type through power output by PWM control. Control method of the second one prevails, but when the power devices have a breakdown, output voltage of the generator rises rapidly. This exciter must have a protection circuit and system is complicated, so reliability is poor Excitation control type which is drop control type control only 10% of the power, so it can be improved precision. When a trouble come to the controller, output voltage of a generator don't rise excessively and the voltage rise about 10%, so it has a excellent reliability. This paper prove stability of the digital AVR.

  • PDF

Application of Disinfection Models on the Plasma Process (플라즈마 공정에 대한 소독 모델 적용)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.695-704
    • /
    • 2012
  • The application of disinfection models on the plasma process was investigated. Nine empirical models were used to find an optimum model. The variation of parameters in model according to the operating conditions (first voltage, second voltage, air flow rate, pH) were investigated in order to explain the disinfection model. In this experiment, the DBD (dielectric barrier discharge) plasma reactor was used to inactivate Ralstonia Solanacearum which cause wilt in tomato plantation. Optimum disinfection models were chosen among the nine models by the application of statistical SSE (sum of squared error), RMSE (root mean sum of squared error), $r^2$ values on the experimental data using the GInaFiT software in Microsoft Excel. The optimum model was shown as Weibull+talil model followed by Log-linear+ Shoulder+Tail model. Two models were applied to the experimental data according to the variation of the operating conditions. In Weibull+talil model, Log10($N_o$), Log10($N_{res}$), ${\delta}$ and p values were examined. And in Log-linear+Shoulder+Tail model, the Log10($N_o$), Log10($N_{res}$), $k_{max}$, Sl values were calculated and examined.

A High Efficiency Zero Voltage/Zero Current Transition Converter for Series Connected Battery Cell Equalization (영전압/영전류 스위칭을 이용한 고효율의 직렬 접속 배터리 전압 밸런싱 방법)

  • Kim, Tae-hoon;Park, Nam-Ju;Hyun, Dong-seok;Kim, Rae-young
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.26-27
    • /
    • 2011
  • This paper focuses on the zero-voltage/zero current transition voltage equalization circuit for the series connected battery cell. By adding auxiliary resonant cells at the main switching devices such as MOSFET or IGBT, zero current switching is achieved and turned off loss of switching elements is eliminated and by the voltage/second balancing of the inductor, zero voltage switching can be applied to switching element. Transformer coupling between battery cells and ZVZCT (Zero Voltage Zero Current Transition) switching method allow the fast balancing speed and high frequency operation, which reduces the size and weight of the circuit. The validity of the battery equalization is further verified using simulation involving four lithium-ion battery cell models.

  • PDF

Design of a High Stable Measuring Circuit for Radioactive Pulses (방사선 펄스의 고안정 계측회로 설계)

  • 송재용;한주섭;천상규;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.577-580
    • /
    • 2000
  • The aim of this paper is to develop a high stable measuring device for radioactive pulses. The device consists of a high voltage supply unit using a fly-back converter principle, and a pulse detection unit for gamma-rays and neutrons. The high voltage supply unit designed can generate DC voltage up to 1,500v at 5V-input, and have a series voltage regulator to maintain the output voltage constantly, resulting in less than 1.63% of voltage regulation. The pulse detection parts consists of an active integrator, a pole-zero circuit, and a 3-stage amplifier of 60 dB, and its frequency bandwidth is from 37 Hz to 300 kHz. From the experimental results, it is confirmed that the measuring device can count at least 10,000 pulses in a second.

  • PDF

A Design of Voltage-Controlled CMOS OTA and Its Application to Tunable Filters (전압-제어 CMOS OTA와 이를 이용한 동조 여파기 설계)

  • 차형우;정원섭
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.8
    • /
    • pp.1260-1264
    • /
    • 1990
  • A voltage controlled CMOS operational transconductance amplifier (OTA), whose transconductance is directly proportional to the DC bias voltage, has been designed for many electronic circuit applications. It consists of a differential pair and three ourrent mirrors. The SPICE simulation shows that the conversion sensitivity of the OTA is 41.817 \ulcornerho/V and the linearity error is less than 0.402% over a bias voltage range from -2. OV to 1. OV. Electrically tunalble filters based on voltage controlled impedances, which are realized with OTA's, also have been designed. The SPICE simulation shows that a second-order bandpass filter, whose center frequency is 23KHz at -1. OV, has the conversion sensitivity 6.6KHz/V and the linearity error less than 0.822% over a voltage range from -2.OV tp 1.OV, Tne OTA has been laid out with the 3\ulcorner n-well CMOS design rule adopted in ISRC (inter-university semiconductor research center). The chip size was about $0.756x0.945mm^2$.

  • PDF