• Title/Summary/Keyword: Seawater-source

Search Result 186, Processing Time 0.033 seconds

The Application and Evaluation of Heating and Cooling System by Seawater Heat Source for Research Center Building in Jeju (제주지역 연구소 건물의 해수열원 냉난방시스템 적용 및 평가)

  • Park, Jin-Young;Kim, Sam-Uel;Chang, Ki-Chang
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.26-31
    • /
    • 2013
  • Use of heat from seawater could be different from the weather conditions of a coastal city and seawater temperatures near the city. It will be a good option to use surface layer water with Heat Pump system for using seawater cooling/heating in Jeju. The study investigates the proper depth for seawater heat gain of Jeju area in Korea. Sampling points are 0, 10, 20, 30m from the surface of the Sea. Seawater temperature does not change significantly according to the depth in winter, while the temperature is quite different according to the depth in summer. In this study, it is analyzed to compare existing system and seawater heat source system for target buildings on Jeju. And this systems are calculated a initial cost.

Performance Test for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy (해수열원 및 폐열이용 고성능 열펌프 시스템 성능실험)

  • 최광일;오종택;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.979-986
    • /
    • 2003
  • The performance characteristics of heating and cooling operation for a heat pump system using seawater heat source and exhaust energy are presented. The heat pump system is made of a waste heat recovery system and a vapor compression refrigeration system. The working fluid is R-22. The heat pump system COPs are measured during heating and cooling operation modes, and the resultant COPs were 9.7 and 7.9, respectively, which are three times higher than those of the heat pump itself. Therefore, the performance of the heat pump system using exhaust energy is excellent compared to that of a general heat pump. The experimental data can be effectively used for the design of the high efficient heat pump using a seawater heat source.

Application and Life Cycle Cost Analysis for Ice-rink using Seawater Heat Source Cooling System (해수 냉방시스템의 빙상경기장 적용 방안 및 LCC 분석)

  • Park, Jin-Young;Kim, Sam-Uel;Lee, Ho-Saeng;Kim, Hyeon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.50-55
    • /
    • 2013
  • On a plan for the Winter Olympics 2018, Korean government is in the process of the world's first use of ocean energy for the Olympic ice-rink. This technology will be applied to a seaside town and have possibility of an export industry. In this study, we researched facilities and system for P ice-rink that acts as a cultural center as well as a physical plant in Busan and provided the way that apply by seawater heat source. Also, existing system and seawater heat source system of P ice-rink was analyzed by the most commonly used life cycle cost analysis among economics methods. Such economics data for ice-rink using seawater will be utilized by a basic information.

Nitrogen and Phosphorus Recoveries from Anaerobic Digester Supernatant Using Seawater as Magnesium Source for Struvite Formation (바닷물을 이용한 struvite 형성으로 혐기성 소화액으로부터 질소, 인 회수)

  • Kim, Yong-Beom;Ahn, Johng-Hwa
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.387-391
    • /
    • 2015
  • This study was performed to evaluate the effect of pH (8-12) and molar ratio of magnesium and phosphate ($[Mg^{2+}]/[PO_4{^{3-}}]$) (0.6-1.4) on struvite crystallization of anaerobic digester supernatant using seawater as magnesium source. pH range of 9-10 is favorable for ammonium and phosphate recoveries. The recovery efficiency of ammonium was highest at $[Mg^{2+}]/[PO_4{^{3-}}]$ of 1.0 and pH 10. On the other hand, high phosphate recovery efficiency (> 99%) was achieved at ($[Mg^{2+}]/[PO_4{^{3-}}]$) of 1.4 and pH 10. The results demonstrated that seawater can be considered as low-cost magnesium source to recover phosphorus from anaerobic digester supernatant.

Pollution of Polycyclic Aromatic Hydrocarbons (PAHs) in Seawater and Marine Sediments from Anmyundo Coastal Area after Oil Spill (유류사고 이후 안면도 연안 해수 및 퇴적물의 다환방향족탄화수소(PAHs) 오염에 관한 연구)

  • Lee, Wan-Seok;Park, Seung-Yoon;Kim, Pyoung-Joong;Jeon, Sang-Baeck;An, Kyoung-Ho;Choi, Yong-Seok
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1421-1430
    • /
    • 2010
  • Polycyclic aromatic hydrocarbons (PAHs) were investigated in seawater and marine sediment from Anmyundo coastal area after oil spill. The concentrations of total PAHs in surface and bottom of seawater at August were 31.1 to 142.6 ng/L and 5.9 to 50.9 ng/L in August and November, respectively. The concentrations of PAHs in sediment were 21.0 to 102.9 ng/g D.W. and 32.3 to 57.4 ng/g D.W. in August and November, respectively. PAHs concentrations in seawater and sediment in August were higher than those in November about 2.5 and 1.4 times, respectively. Diagnostic ratio (PhA/AnT and FluA/Pyr) were investigated to identify source of PAHs in seawater and sediment. The PAHs in seawater originated from pyrolytic source and those in sediment originated from pyrolytic and petrogenic source. The glass, wood and coal origin was higher than petroleum origin on the combustion origin of PAHs in seawater and sediment. The seawater of Anmyundo costal area recovered from oil spill, but the sediments of that were weakly influenced by oil spill until now. Because this area is developed many fishing grounds, demanded Long Term Environmental Monitoring Program (LTEMP). The concentrations of PAHs on depth of sediments were investigated at station 8 and 10. The concentrations of PAHs were decreased with increasing depth.

Performance Characteristics of Flooded Type Evaporator for Seawater Cooling System with Heat Source Temperature of Mid-year (중간기 열원수 온도에 따른 만액식 해수냉각시스템의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Lee, Jeong-Mok;Kang, In-Ho
    • Journal of Power System Engineering
    • /
    • v.21 no.2
    • /
    • pp.64-69
    • /
    • 2017
  • The purpose of this study is to investigate the performance characteristics of seawater cooling system for a fishing vessel. The circulation amount of refrigerant, condensation capacity, evaporation capacity, compression work and coefficient of performance(COP) were analyzed as the heat source temperature changed. The experimental setup consisted of an open-type compressor, a shell&tube type condenser, an evaporator and an expansion valve. The heat source was controlled by a constant temperature chamber. The main results of this study are summarized as follows. The condensation capacity increased with increasing heat source temperature, and it was confirmed that the effect of circulating amount of refrigerant was dominant. The amount of heat for vaporization was almost constant even though the temperature of the heat source increased. On the other hand, the compression power was increased. This is because the compression ratio increases as the condensation pressure, the enthalpy difference between inlet and outlet, the amount of circulating refrigerant increases. The performance coefficient of this system showed a tendency decreasing with increasing heat source temperature. Therefore, the basic data of the seawater cooling system for the maintenance of the catch line of the shore fishing boats was acquired through this study, and it is considered that it will be sufficient for the actual design.

A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump (해수열원 스크류 히트펌프의 연간 난방운전 성능 모사)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Lee, Young-Soo;Kim, Hyeon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump (해수열원 스크류 히트펌프의 연간 난방운전 성능 시뮬레이션)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Kang, Byung-Chan;Ra, Ho-Sang;Kim, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.488-493
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

  • PDF

Desalination of Seawater by Reverse Osmosis (역삼투법에 의한 해수의 담수화에 관한 연구)

  • Lee, Sun Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.155-164
    • /
    • 2004
  • Many countries, including Korea, suffer from a shortage of freshwater. With increases in population and the quality of life, along with large-scale expansion in industrial and agricultural activities, more freshwater is needed. Available resources, Including ground water, are limited, and desalination presents the opportunity for a new unlimited source of freshwater from the sea. The objectives of this study were to test membrane performance in seawater desalination and to examine the quality of water produced. bath well and sea water were used as water sources. Typically used membrane for seawater desalination and high rejection seawater desalination membrane are maintained at almost same recovery rate and permeate flux, while the conductivity was lower in the operation of typically used seawater membrane. The treated water quality using two types of membranes is satisfied with the Korea drinking water quality standards.

Performance Analysis of Ocean Thermal Energy Conversion on Working Fluid Classification (작동유체에 따른 온도차발전사이클의 성능 해석)

  • Lee, Ho-Saeng;Moon, Jung-Hyun;Kim, Hyeon-Ju
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.79-84
    • /
    • 2016
  • The thermodynamic performance of ocean thermal energy conversion with 1 kg/s geothermal water flow rate as a heat source was evaluated to obtain the basic data for the optimal design of cycle with respect to the classification of the working fluid. The basic thermodynamic model for cycle is rankine cycle and the geothermal water and deep seawater were adapted for the heat source of evaporator and condenser, respectively. R245fa, R134a are better to use as a working fluid than others in view of the use of geothermal water. It is important to select the proper working fluid to operate the ocean thermal energy conversion. So, this paper can be used as the basic data for the design of ocean thermal energy conversion with geothermal water and deep seawater.