• Title/Summary/Keyword: Seating

Search Result 223, Processing Time 0.019 seconds

Prevalence and Related Factors of Knee Osteoarthritis in Rural Women (농촌여성의 무릎 골관절염 유병률 및 관련요인)

  • Seo, Joong-Hwan;Kang, Pock-Soo;Lee, Kyeong-Soo;Yun, Sung-Ho;Hwang, Tae-Yoon;Park, Jong-Seo
    • Journal of agricultural medicine and community health
    • /
    • v.30 no.2
    • /
    • pp.167-182
    • /
    • 2005
  • Objectives: This study was performed to investigate the prevalence of knee osteoarthritis according to the criteria of diagnosing knee osteoarthritis in rural women and the factors related with this disease. Methods: The data obtained from 200 women older than 40 years of age residing in 5 Ri's in Goryeong-gun. Gyeongsanbuk-do by random cluster sampling from September to October 2002. Knee osteoarthritis was determined positive according to the Kellgren and Lawrence classification and knee pain. Results: Among these subjects, 71.0% showed more than grade 2 in radiologic finding and the rate of knee pain according to the survey was 67.0%. The rate of subjects meeting the criteria of knee osteoarthritis was 54.0%. According to univariate analysis, the prevalence of knee osteoarthritis increased with age and those farming people and people working in household industry was significantly high at 58.9% compared with others. The prevalence of knee osteoarthritis showed a significant relationship with the family history and past history of knee injury and knee surgery(p<0.01), and diabetes mellitus(p<0.05). The score of ADL was significantly different in the subjects with knee osteoarthritis compared with normal group(p<0.05). When the presence of knee osteoarthritis and the period of the life style of seating down on the floor were compared, a significant difference was present between the osteoarthritis group and normal group. As for metabolic factors, the blood sugar level, bone density, and body mass index(BMI) were significantly different in the osteoarthritis group compared with normal group. When multiple logistic regression analysis was performed with the presence of knee osteoarthritis as the dependent variable, the prevalence of knee osteoarthritis was significantly affected by older age, subjects farming or working in household industry, the history of knee injury, the history of surgery, higher blood sugar level, and higher BMI. Conclusions: These subjects need an intervention through self-care programs such as exercise for preventing osteoarthritis, weight control programs, other exercise programs strengthening knee joints, and guidelines when working in vinyl houses.

  • PDF

In Vitro Evaluation of Shear Bond Strengths of Zirconia Cerami with Various Types of Cement after Thermocycling on Bovine Dentin Surface (지르코니아 표면 처리와 시멘트 종류에 따른 치면과의 전단 결합 강도 비교 연구)

  • Cho, Soo-Hyun;Cho, In-Ho;Lee, Jong-Hyuk;Nam, Ki-Young;Kim, Jong-Bae;Hwang, Sang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.249-257
    • /
    • 2007
  • State of problem : The use of zirconium oxide all-ceramic material provides several advantages, including a high flexural strength(>1000MPa) and desirable optical properties, such as shading adaptation to the basic shades and a reduction in the layer thickness. Along with the strength of the materials, the cementation technique is also important to the clinical success of a restoration. Nevertheless, little information is available on the effect of different surface treatments on the bonding of zirconium high-crystalline ceramics and resin luting agents. Purpose : The aim of this study was to test the effects of surface treatments of zirconium on shear bond strengths between bovine teeth and a zirconia ceramic and evaluate differences among cements Material and methods : 54 sound bovine teeth extracted within a 1 months, were used. They were frozen in distilled water. These were rinsed by tap water to confirm that no granulation tissues have left. These were kept refrigerated at $4^{\circ}C$ until tested. Each tooth was placed horizontally at a plastic cylinder (diameter 20mm), and embedded in epoxy resin. Teeth were sectioned with diamond burs to expose dentin and grinded with #600 silicon carbide paper. To make sure there was no enamel left, each was observed under an optical microscope. 54 prefabricated zirconium oxide ceramic copings(Lava, 3M ESPE, USA) were assigned into 3 groups ; control, airborne-abraded with $110{\mu}m$ $Al_2O_3$ and scratched with diamond burs at 4 directions. They were cemented with a seating force of 10 ㎏ per tooth, using resin luting cement(Panavia $F^{(R)}$), resin cement(Superbond $C&B^{(R)}$), and resin modified GI cement(Rely X $Luting^{(R)}$). Those were thermocycled at $5^{\circ}C$ and $55^{\circ}C$ for 5000 cycles with a 30 second dwell time, and then shear bond strength was determined in a universal test machine(Model 4200, Instron Co., Canton, USA). The crosshead speed was 1 mm/min. The result was analyzed with one-way analysis of variance(ANOVA) and the Tukey test at a significance level of P<0.05. Results : Superbond $C&B^{(R)}$ at scratching with diamond burs showed the highest shear bond strength than others (p<.05). For Panavia $F^{(R)}$, groups of scratching and sandblasting showed significantly higher shear bond strength than control group(p<.05). For Rely X $Luting^{(R)}$, only between scratching & control group, significantly different shear bond strength was observed(p<.05). Conclusion : Within the limitation of this study, Superbond $C&B^{(R)}$ showed clinically acceptable shear bond between bovine teeth & zirconia ceramics regardless of surface treatments. For the surface treatment, scratching increased shear bond strength. Increase of shear bond strength by sandblasting with $110{\mu}m$ $Al_2O_3$ was not statistically different.

A Study on Bracket-Adhesive Combinations in Aspect of Shear Bond Strength and Bond Failure (전단접착강도와 탈락양상을 고려한 브라켓-접착제의 선택)

  • Han, Jae-Ik;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.955-974
    • /
    • 1998
  • The purpose of the present study was to seek bracket-adhesive combinations which have adequate bond strength with no enamel and bracket fracture. The shear bond strengths were measured, the sites of failure and the enamel damage were investigated and the peripheral sealing and adaptation between enamel surface, bonding adhesive and bracket were evaluated. 240 noncarious human premolars were divided into twenty four groups of ten teeth. Shear bond strengths of each group were determined in an universal testing machine after two days passed and the debonded specimens were inspected to determine the predominant bond failure sites. To evaluate peripheral sealing and adaption between enamel surface, adhesive and bracket, each specimen was cut longitudinally into two halves which included the midsection of the bracket, adhesive and enamel and exmined in scanning electron microscope. Six different types of brackets were bonded to the tooth with four different type of adhesives. Six different types of brackets were Image, Plastic, Crystaline, Fascination, Transcend 2000 and metal bracket and four different adhesives were No-mix, Light-Bond, OrthoLC and Superbond C&B. From this study, it may be concluded that (1) The mean shear bond strength varied from a high of 36.58 Kg (410.07 Kg/$cm^2$) with the Fascination-Light Bond combination group to a low of 8.93 Kg (75.51 Kg/$cm^2$) with theImage-OrthoLC combination group. When using OrthoLC as adhesive, the mean shear bond strength was significantly lower than that of other combination groups, (2) Regardless of adhesives, the mean shear bond strength of Fascination brackets was relatively high whereas Plastic and Image brackets had low shear bonding strength. The shear bond strength of Crystaline bracket and Transcend 2m was relatively equal to or lower than that of metal bracket, (3) There was a correlation between bond strength, enamel damage and bracket fracture. As the shear bond strength was increased, the rate of enamel damage and bracket fracture were increased, (4) The combination groups that use OrthoLC as adhesive were debonded in shear stress without enamel fracture and bracket fracture, whereas the combination groups that use Superbond C&B as adhesive experienced a relative high enamel fracture rate and bracket fracture rate, (5) Peripheral sealing and adaptation between enamel-adhesive-bracket were relatively good when using Light-Bond or No-mix as adhesive. Regardless of adhesives, adaptation between bracket-adhesive were relatively good in Ceramic brackets, (6) The combination groups which had adequate bonding strength with no enamel and bracket fracture were Crystaline-No mix, Crystaline-Light Bond, Crystaline-OrthoLC, metal-No mix, metal-Light Bond and metal-OrthoLC combination groups.

  • PDF