• Title/Summary/Keyword: Seat-cushion angle

Search Result 3, Processing Time 0.017 seconds

A Study on Characterizing a Healthy Driving Posture (건강한 운전 자세 특성 연구)

  • Kim, Darae;Choi, Hyungyun;Lee, Joungho;Ahn, Sungmin;Lee, Shiuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.5
    • /
    • pp.121-129
    • /
    • 2013
  • To find a healthy driving posture, in this study, survey and empirical analysis given onto measurement of car-seat angle has been performed. Among 153 male respondents, those drivers who has minimum 5 year experience and 2 hours daily driving has been selected by a multiple screening process. They were further confirmed to have no discomfort history in any body region caused by the driving task. Final 44 people verified that their actual driving posture is not significantly different (p = 0.692) from healthy one they think. And their data, accordingly, the healthy driving postures are clustered based on the same seat-cushion angle, seat-back angle and trunk-thigh angle. Consequently, three seat-angles of the 44 subjects showed a significant difference only with their height information which is the most effecting factor on driving posture among the physical characteristics. That is a first result categorized healthy driving posture classified physical, if it were departmentalized into additional study, could be able to reflected a factor of "healthy" on car seat design.

Development of body position sensor device for posture correction training (자세 교정훈련을 위한 체위 변환 감지 센서 디바이스의 개발)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2020
  • Recently the incidence of musculoskeletal disorders in students and office workers is increasing, and the necessity of maintaining correct posture and corrective training is required, but related research is insufficient. In the previous study, a membrane sensor or a pressure sensor was placed on the seat cushion to see the deviation of the body weight, or a sensor that restrained the user was attached to measure the position change. In this study, a sensor device for detecting a position change in consideration of wearing comfort was developed, and the measured angle was verified through an analysis app. A sensor device consisting of an IMU sensor is attached to the cervical spine and vertebra spine to measure the position transformation in the sitting position. The change value of the position measured by the two sensors was converted into an angle, and the angle value is displayed in real time through the analysis app. In this study, the possibility of measuring the real-time change value according to the change in position, the convenience of wearing, and the tendency of angle measurement were proved. Future research should proceed with more precise angle calculation and correction of motion noise.

Evaluation of measuring accuracy of body position sensor device for posture correction (자세교정을 위한 체위변환 감지 센서 디바이스의 정확성 평가)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Kang, Min-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.128-133
    • /
    • 2021
  • Recently Recently, the incidence of spinal diseases due to poor posture among students and office workers is increasing, and various studies have been conducted to help maintain correct posture. In previous studies, a membrane sensor or a pressure sensor was placed on the seat cushion to see the weight bias, or a sensor that restrained the user was attached to measure the position change. In our previous study, we developed a sensor device which can be easily attached to the body with an adhesive gel sheet and that measures and outputs the user's posture and body position in real time, but it has a limitation in the accuracy of the sensor value. In this study, a study was conducted to improve the performance of the position conversion sensor device and quantitatively evaluate the accuracy of the angle conversion measurement value, and a high accuracy with 2.53% of error rate was confirmed. In future research, it is considered that additional research targeting actual users is needed by diversifying posture correction training contents with multimedia elements added.