• Title/Summary/Keyword: Seasonal Performance Factor

Search Result 34, Processing Time 0.022 seconds

Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building (업무용 건물의 지열 히트펌프 시스템에 대한 성능 예측)

  • Sohn, Byonghu;Kwon, Han Sol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.409-415
    • /
    • 2014
  • Ground-source heat pump (GSHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy efficiency. These systems use the ground as a heat source and the heat sink for cooling mode operation. The purpose of this simulation study is to evaluate the performance of a hypothetical GSHP system in an office building and to assess the energy saving effect against the existing HVAC systems (boiler and turbo chiller). We collected monthly energy consumption data from an actual office building ($32,488m^2$) in Seoul, and created a model to calculate the hourly building loads with EnergyPlus. In addition, we used GLD (Ground Loop Design) V8.0, a GSHP system design and simulation software tool, to evaluate hourly and monthly performance of the GSHP system. The energy consumption for the GSHP system based on the hourly simulation results were estimated to be 582.6 MWh/year for cooling and 593.2 MWh/year for heating, while those for the existing HVAC systems were found to be 674.5 MWh/year and 2,496.4 MWh/year, respectively. The seasonal performance factor (SPF) of the GSHP system was also calculated to be in the range of 3.37~4.28.

Prediction and Analysis of PM2.5 Concentration in Seoul Using Ensemble-based Model (앙상블 기반 모델을 이용한 서울시 PM2.5 농도 예측 및 분석)

  • Ryu, Minji;Son, Sanghun;Kim, Jinsoo
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1191-1205
    • /
    • 2022
  • Particulate matter(PM) among air pollutants with complex and widespread causes is classified according to particle size. Among them, PM2.5 is very small in size and can cause diseases in the human respiratory tract or cardiovascular system if inhaled by humans. In order to prepare for these risks, state-centered management and preventable monitoring and forecasting are important. This study tried to predict PM2.5 in Seoul, where high concentrations of fine dust occur frequently, using two ensemble models, random forest (RF) and extreme gradient boosting (XGB) using 15 local data assimilation and prediction system (LDAPS) weather-related factors, aerosol optical depth (AOD) and 4 chemical factors as independent variables. Performance evaluation and factor importance evaluation of the two models used for prediction were performed, and seasonal model analysis was also performed. As a result of prediction accuracy, RF showed high prediction accuracy of R2 = 0.85 and XGB R2 = 0.91, and it was confirmed that XGB was a more suitable model for PM2.5 prediction than RF. As a result of the seasonal model analysis, it can be said that the prediction performance was good compared to the observed values with high concentrations in spring. In this study, PM2.5 of Seoul was predicted using various factors, and an ensemble-based PM2.5 prediction model showing good performance was constructed.

Empirical Study on the Forecasting of the Hotel Room Sales (호텔 객실판매 예측에 관한 실증적 연구 - 서울지역 특급호텔을 중심으로 -)

  • Han, Seung-Youb
    • Korean Business Review
    • /
    • v.4
    • /
    • pp.281-295
    • /
    • 1991
  • Nothing is more incorrect than forecasting. Nevertheless, forecasting is one of the most important business activities for the effective management. There has been rapid changes of the growth rate in every respect of the Korean hospitaity industry, especially the hotel industry, before and after the 88 Olympic Games. Therefore, the hoteliers shall be in need of more-than-ever accourate demand forecasting for the more systematic management and control. Under the above circumstances, this study suggested the best forecasting technique and method for the better sales and operations of the hotel rooms. The number of rooms sold is selected as a dependent variable of this study which is regarded as the best representative factor of measuring the growth rate of the rooms division performance of the hotels. The first step was to select the most verifiable independent variable diferently from the other countries or other areas of Korea. As a result, the number of foreign visitors was chosen. Empirical research, i.e. correlation and multiple regression analysis, shows that this independent variable has a strong relationship with the dependent variable told above. The second procedure was to estimate the number of rooms will be sold in 1991 on the basis of the formula calculated through the multiple regression analysis. Time series technique was conducted using the data of the number of foreign visitors by purpose of travel from 1987 to 1990. For the more correct forecasting, however, it would be desirable to adopt the data from 1989 considering the product or the industry life cycle. In addition, deeper analysis for the monthly or seasonal forecasting method is needed as a future research.

  • PDF

Experimental Study on Performance Comparison of Air-Conditioner with PF Heat Exchanger (PF 열교환기를 적용한 공조기의 성능 비교 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.470-475
    • /
    • 2009
  • In the present study, the heat transfer characteristics of the fin-tube and PF heat exchangers and the performances of the air-conditioner are experimentally investigated. Also, Cooling Seasonal Performance Factor(CSPF) of the air-conditioner is evaluated. For the heat exchanger experiment, the heat transfer and pressure drop are obtained. For the air-conditioner experiment, the cooling capacity, input power and COP are obtained. The air-enthalpy calorimeter and the constant temperature water bath are used. As the inlet air velocity increases, the heat transfer rate and pressure drop of the heat exchanger increased. PF heat exchanger has smaller refrigerant weight and larger capacity and COP than the fin-tube heat exchanger. The performance of PF-2 heat exchanger with the squarer fin is more excellent than that of PF-1 heat exchanger with the triangler fin. Also, CSPF of the fm -tube and PF heat exchanger is evaluated.

A Study on the Factors that Affect the On-Time Performances of Airline Companies (항공사 정시성에 영향을 주는 요인에 관한 연구)

  • Kwon, Bo-Hun;Jung, Jin-Young;Kim, Hyeon-Deok
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.5
    • /
    • pp.320-326
    • /
    • 2021
  • In airlines, on-time performance (OTP) is a measure of an airline's reliability and can be used as an important indicator when compared to other airlines. This study analyzed the effects and strength of delay factors on airline punctuality by analyzing the data of domestic K airlines for one year before and after March 2020, when the number of flights drastically decreased due to the corona virus. In addition, delays caused by seasonal weather effects were analyzed, and how the number of passengers who plummeted due to the corona situation had an effect on delay factors was studied. As for the delay factors, the delay codes of K airline which added its own codes to the delay codes of IATA, were applied. Based on the results of the analysis, we would like to suggest a method to minimize the delay.

Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials (석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구)

  • Ha, Joo-Yeon;Shin, Hyun-Gyoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.

Studies on the Mackerel Purse Seine operating in the Sea Area of Cheju island - 3. Fishing Ability of Purse Seiner by Classes of Boat-Size - (제주도 주변해역 고등어 건착망의 연구 - 3 . 망선의 선급별 어획성능 -)

  • 박정식
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.2
    • /
    • pp.61-69
    • /
    • 1989
  • Mackerel purse seine fishery operating in the sea area of Cheju and Tsushima is one of the most important fishery in Korean off shore fishery, which a fishing fleet are generally composed with one purse seiner, two light ships and three or four fish carriers. In this study, purse seiners are classified in to four classes in term of their gross tonnage : A class(80-100tons), B class(100-120tons), C class(130-140tons), and D class(140-150tons). Operating sea area are divided into five sectors including east and west sea area of Tsushima Island, coastal sea area of Cheju Island and south and west sea area of Cheju Island. The performance of the purse seiner, the fishing efficiency, the dimension of fishing gear and variation of CPUE in each operating sea area are summarized as follows: 1. The relationship between a gross tonnage x and net area of purse seine y of a purse seiner can be expressed as : y=538.8x+99657.3 2. The index of seasonal variation of CPUE from May to October is lower than the standard value, whereas index from November to April is higher. 3. The power factor of fishing efficiency by classes of boat-size shows significant differences with 1% level in each operating sea area. 4. The net efficiency of purse seiner by classes of boat-sea shows that B and C classes are higher than A and D classes.

  • PDF

Association of a Single Codon Deletion in Bone Morphogenetic Protein 15 Gene with Prolificacy in Small Tail Han Sheep

  • Guo, W.;Chu, M.X.;Deng, X.M.;Feng, J.D.;Li, Ning;Wu, Changxin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.11
    • /
    • pp.1491-1495
    • /
    • 2004
  • Small Tail Han Sheep has significant characteristics of high prolificacy and non-seasonal ovulatory activity and is an excellent local sheep breed in P. R. China. Recently a novel member of the transforming growth factor $\beta$ (TGF$\beta$) superfamily termed bone morphogenetic protein 15 (BMP15) was shown to be specifically expressed in oocytes and to be essential for female fertility. Therefore, BMP15 is a candidate gene for reproductive performance of Small Tail Han Sheep. The whole genomic nucleotide sequence of BMP15 gene in Small Tail Han Sheep was searched for polymorphisms by PCR-SSCP and direct sequencing, and only one polymorphism was found. The polymorphism was a result of a 3 base pair deletion, which eliminated a single Leu codon (CTT). The allelic frequencies for A (without deletion) and B (with a codon deletion) are 0.73 and 0.27 respectively. The effects of BMP15 genotype on litter size were evaluated using the least squares model. This indicated that there was a significant association between litter size of Small Tail Han Sheep and a deletion in BMP15 gene (p=0.02<0.05). Small Tail Han Sheep ewes with AA and AB genotype produce on average 0.5 and 0.3 more lambs per litter than those ewes with BB genotype.

Large-scale Atmospheric Patterns associated with the 2018 Heatwave Prediction in the Korea-Japan Region using GloSea6

  • Jinhee Kang;Semin Yun;Jieun Wie;Sang-Min Lee;Johan Lee;Baek-Jo Kim;Byung-Kwon Moon
    • Journal of the Korean earth science society
    • /
    • v.45 no.1
    • /
    • pp.37-47
    • /
    • 2024
  • In the summer of 2018, the Korea-Japan (KJ) region experienced an extremely severe and prolonged heatwave. This study examines the GloSea6 model's prediction performance for the 2018 KJ heatwave event and investigates how its prediction skill is related to large-scale circulation patterns identified by the k-means clustering method. Cluster 1 pattern is characterized by a KJ high-pressure anomaly, Cluster 2 pattern is distinguished by an Eastern European high-pressure anomaly, and Cluster 3 pattern is associated with a Pacific-Japan pattern-like anomaly. By analyzing the spatial correlation coefficients between these three identified circulation patterns and GloSea6 predictions, we assessed the contribution of each circulation pattern to the heatwave lifecycle. Our results show that the Eastern European high-pressure pattern, in particular, plays a significant role in predicting the evolution of the development and peak phases of the 2018 KJ heatwave approximately two weeks in advance. Furthermore, this study suggests that an accurate representation of large-scale atmospheric circulations in upstream regions is a key factor in seasonal forecast models for improving the predictability of extreme weather events, such as the 2018 KJ heatwave.

Performance assessment of an urban stormwater infiltration trench considering facility maintenance (침투도랑 유지관리를 통한 도시 강우유출수 처리 성능 평가)

  • Reyes, N.J. D.G.;Geronimo, F.K.F.;Choi, H.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.424-431
    • /
    • 2018
  • Stormwater runoff containing considerable amounts of pollutants such as particulates, organics, nutrients, and heavy metals contaminate natural bodies of water. At present, best management practices (BMP) intended to reduce the volume and treat pollutants from stormwater runoff were devised to serve as cost-effective measures of stormwater management. However, improper design and lack of proper maintenance can lead to degradation of the facility, making it unable to perform its intended function. This study evaluated an infiltration trench (IT) that went through a series of maintenance operations. 41 monitored rainfall events from 2009 to 2016 were used to evaluate the pollutant removal capabilities of the IT. Assessment of the water quality and hydrological data revealed that the inflow volume was the most relative factor affecting the unit pollutant loads (UPL) entering the facility. Seasonal variations also affected the pollutant removal capabilities of the IT. During the summer season, the increased rainfall depths and runoff volumes diminished the pollutant removal efficiency (RE) of the facility due to increased volumes that washed off larger pollutant loads and caused the IT to overflow. Moreover, the system also exhibited reduced pollutant RE for the winter season due to frozen media layers and chemical-related mechanisms impacted by the low winter temperature. Maintenance operations also posed considerable effects of the performance of the IT. During the first two years of operation, the IT exhibited a decrease in pollutant RE due to aging and lack of proper maintenance. However, some events also showed reduced pollutant RE succeeding the maintenance as a result of disturbed sediments that were not removed from the geotextile. Ultimately, the presented effects of maintenance operations in relation to the pollutant RE of the system may lead to the optimization of maintenance schedules and procedures for BMP of same structure.