• 제목/요약/키워드: Sealing units

검색결과 13건 처리시간 0.026초

접촉식 시일장치의 밀봉 접촉면 형상에 대한 최적화 설계연구 (Optimization Design on the Sealing Surface Profiles of Contacting Seal Units)

  • 김청균
    • 한국생산제조학회지
    • /
    • 제20권6호
    • /
    • pp.761-766
    • /
    • 2011
  • In this study, the optimized design profiles between a seal ring and a seal seat of contacting seal units has been proposed based on the FEM computed results. The maximum temperatures, the thermal distortions in axial and radial directions, and maximum contact normal stresses between a seal ring and a seal seat have been analyzed for various contact sealing profiles. The FEM computed results present that the contact area between seal rings and seal seats is very important for a good tribological performance such as low friction heating, low wear, high contact normal stress in a primary sealing components. The seal surface model III in which has a small sealing contact area shows low dilatation of primary sealing components, and high contact stress between a seal ring and a seal seat. This model with small contact surface of a seal ring produces high friction heating and contact stress. But the model III produces very small deformations of contacting sealing surface because of high convection heat transfer by cooling water circulation around the seal ring surface. Thus, the analysis results recommend a short width of a primary sealing unit rather than a big width of contact surfaces of contacting seal units for reducing a leakage and axial deformation of primary seal components.

LPG 용기용 밸브의 밀봉부품 크랙 및 결함에 관한 실험적 고찰 (Experimental Investigation on Cracks and Defects of a Valve Sealing Components for a LPG Cylinder)

  • 김청균;이병관;김태환
    • 한국가스학회지
    • /
    • 제11권1호
    • /
    • pp.23-28
    • /
    • 2007
  • 본 본문에서는 LPG 용기용 가스밸브의 O-링과 밸브패킹의 밀봉결함과 크랙에 관련된 실험적 연구를 수행하고자 한다. LP 가스의 누출을 방지하기 위해 사용하는 O-링은 LPG 밸브의 밀봉 안전성을 확보하는 핵심부품으로 대단히 중요하다. 밸브패킹은 LPG 연료의 공급과 충전을 하는데, 가스 공급구를 열고 닫는 중요한 역할을 담당한다. 이들 두개의 밀봉부품에 대한 성능은 밸브의 누설 안전성과 장수명에 밀접한 관련이 있다. 연구결과에 의하면, O-링의 대부분은 파티션 부근의 결합불량과 과도한 압축률로 인해 원주방향으로 크랙이 발생하는 것으로 분석되었다. 그 이외의 결함으로 거론된 경우는 LP가스의 과도한 가스압력으로 인한 압출현상의 발생은 압출크랙을 일으키는 원인으로 작용하고 있다. 따라서 본 논문에서는 가스밸브의 누설 안전성을 확보하고 수명을 연장하기 위해 O-링과 밸브패킹에 대한 엄격한 품질관리와 인증제도의 도입을 권장하고자 한다. 결국에는 LPG용기용 밸브의 품질과 안전성 확보를 위해 밀봉장치에 대한 품질안전 보증제도를 도입해야 밸브를 오랫동안 사용할 수 있을 것이다.

  • PDF

단감 자동정렬 포장장치 개발 (Development of an Automated Ordering and Packing Units for Sweet Persimmons)

  • 김진현;최중섭;김태욱
    • Journal of Biosystems Engineering
    • /
    • 제27권5호
    • /
    • pp.399-408
    • /
    • 2002
  • The sweet persimmons are producted 227,394 tons per year in Korea. They are preserved at cold storage after wrapping them in packing vinyl to maintain quality. Using conventional handwork, a skillful worker could probably produce only 1,000 packings a day. Hiring many skilled-labors to wrap sweet persimmons in packing vinyl seems to be difficult because of the recent rural crisis. Therefore, it was necessary to be developed for the automated ordering and packing unit that is convenient and laborsaving. This study were summarized as follows : Success rates of 99%, 100%, and 88% were observed for ordering parts, sealing and cutting films, and sealing films in the inlet part, respectively. The time required per 1 cycle was 16 seconds and the developed unit performed 225 cycles an hour. The unit showed an ability of 1,125 pieces per hour. Therefore, the productivity was 10 times greater than that of skillful handwork.

마찰접촉조건에 따른 소수력 수차용 밀봉장치의 마찰.마멸특성 연구 (A Study on the Friction and Wear Characteristics of Contact Sealing Units for a Small Hydro-power Turbine Under Various Rubbing Conditions)

  • 김청균
    • Tribology and Lubricants
    • /
    • 제22권6호
    • /
    • pp.314-319
    • /
    • 2006
  • In this paper, the friction and wear characteristics of contact type sealing unit far a water turbine have been presented. The sealing unit for a small hydropower generation is to stop a leakage of circulating water from an outside of an impeller to an inside of a rolling bearing. The friction heating between a seal ring and a seal seat may radically increase a surface temperature in which increase a power loss and wear on the rubbing surface. The surface wear strongly affect to the seal life of a mechanical face seal. In this study, the hardness of a stainless steel in which is a heat-treated is 892.8 in Victors hardness and the hardness of silicone carbide of SiC is 714.1 in Victors hardness. The surface hardness of a heat-treated stainless steel is 25% high compared with that of a ceramic material of SiC. The contact modes of rubbing surfaces are a dry friction, a water film friction and a mixed friction that is contaminated by a dust, silt, and moistures, etc. These two factors of a contact rubbing modes and a material property are very important parameters on the tribological performance such as a friction and wear between a seal ring and a seal seat in primary sealing unit. The experimental result shows that the surface hardness of a seal material is very important on the friction coefficient and a wear volume. Thus, the results recommend higher hardness of a seal material, which may reduce a friction loss and increase a wear life of primary seal components.

Sealing capability and marginal fit of titanium versus zirconia abutments with different connection designs

  • Sen, Nazmiye;Sermet, Ibrahim Bulent;Gurler, Nezahat
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.105-111
    • /
    • 2019
  • PURPOSE. Limited data is available regarding the differences for possible microleakage problems and fitting accuracy of zirconia versus titanium abutments with various connection designs. The purpose of this in vitro study was to investigate the effect of connection design and abutment material on the sealing capability and fitting accuracy of abutments. MATERIALS AND METHODS. A total of 42 abutments with different connection designs [internal conical (IC), internal tri-channel (IT), and external hexagonal (EH)] and abutment materials [titanium (Ti) and zirconia (Zr)] were evaluated. The inner parts of implants were inoculated with $0.7{\mu}L$ of polymicrobial culture (P. gingivalis, T. forsythia, T. denticola and F. nucleatum) and connected with their respective abutments under sterile conditions. The penetration of bacteria into the surrounding media was assessed by the visual evaluation of turbidity at each time point and the number of colony forming units (CFUs) was counted. The marginal gap at the implant- abutment interface (IAI) was measured by scanning electron microscope. The data sets were statistically analyzed using Kruskal-Wallis followed by Mann-Whitney U tests with the Bonferroni-Holm correction (${\alpha}=.05$). RESULTS. Statistically significant difference was found among the groups based on the results of leaked colonies (P<.05). The EH-Ti group characterized by an external hexagonal connection were less resistant to bacterial leakage than the groups EH-Zr, IT-Zr, IT-Ti, IC-Zr, and IC-Ti (P<.05). The marginal misfit (in ${\mu}m$) of the groups were in the range of 2.7-4.0 (IC-Zr), 1.8-5.3 (IC-Ti), 6.5-17.1 (IT-Zr), 5.4-12.0 (IT-Ti), 16.8-22.7 (EH-Zr), and 10.3-15.4 (EH-Ti). CONCLUSION. The sealing capability and marginal fit of abutments were affected by the type of abutment material and connection design.

Comparison of the sealing ability of various bioceramic materials for endodontic surgery

  • Benjamin Rencher ;Ana M. Chang ;Hanson Fong;James D. Johnson;Avina Paranjpe
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.35.1-35.11
    • /
    • 2021
  • Objectives: Endosequence Bioceramic Root Repair Material (BC-RRM) is used in endodontic microsurgery. It is available as a paste and a putty. However, no studies to date have examined the sealing ability of these forms alone or in combination as root-end filling materials. Hence, this study aimed to compare the sealing properties of these 2 forms of BC-RRM. Materials and Methods: Forty-two extracted upper anterior teeth were divided into 3 experimental groups, a positive and negative control. After the root canal treatment, the root ends were resected, retroprepared and retrofilled with either putty, paste + putty or mineral trioxide aggregate (MTA). The teeth were mounted in tubes so the apical 3 mm was submerged in Brain Heart Infusion (BHI) broth. The coronal portions of the canals were inoculated with Enterococcus faecalis and BHI broth and incubated for 30 days. The broth in the tubes was analyzed for colony forming units to check for leakage of bacteria from the canal. The teeth from the groups were sectioned and analyzed using scanning electron microscopy (SEM). The Kruskal-Wallis test and analysis of variance were used to analyze the data with a significance level p < 0.05. Results: The BC-RRM and MTA groups showed similar sealing ability. The positive control showed leakage in all samples. The SEM imaging showed the presence of bacteria in all experimental groups at the material-tooth interface. Conclusions: No significant differences were noted in the experimental groups, providing sufficient evidence that any combination could be effectively used during endodontic microsurgery.

아르곤가스 주입 단열 복층유리 내구성 평가 (Evaluation for Argon gas-filled Insulating glass units)

  • 김경남;정진영;배기선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.128-131
    • /
    • 2013
  • Energy losses through windows and doors are big problems in the construction industry. For glass only, it has takes the largest portion of mass from window assembly and it responsible for 24 ~ 45% of energy loss from total building energy loss. Insulating glass unit should maintain their basic functions during their working life in order to contribute positively for global warming issue. There have been many research works for improving insulating glass unit durability. But it is not easy job to fulfill the requirements because insulating glass units composed of many components. So, overall it is required to have right qualify control procedures starting from material selection to fabrication, shipping and installation to the customer site. In this report, we have reviewed the durability of insulating glass unit made from different grades of sealing materials based on globally accepted industry codes such as EN1279. ASTM E 2190 and Locally available code. KS L 2003. The result showed that there is a relationship between the mechanical properties of insulating glass 2nd sealant and the durability of the units.

  • PDF

In vivo에서 상아질 접착제 도포가 상아세관액 이동과 치수신경활동에 미치는 영향 (IN VIVO EFFECTS OF DENTIN BONDING AGENTS ON DENTINAL FLUID MOVEMENT AND INTRADENTAL NERVE ACTIVITY)

  • 손호현;이광원;박수정
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.425-435
    • /
    • 1996
  • The effect of application of dentin bonding agent to the exposed dentin on the intradental nerve activity (INA), dentinal fluid movement and sealing of the dentinal tubules, was investigated in this study. The INA was recorded from the single pulp nerve unit dissected from the inferior alveolar nerve. And specimen of dentin was observed by SEM. Dentinal fluid 'movement through exposed dentin surface was measured before and after the application of dentin bonding agent. 1. Eight Ao-fiber units (conduction velocity: $8.0{\pm}4.0m$/sec) were identified. 4M NaCl evoked an irregular burst of action potentials which ceased immediately after washing. 2. In 4 $A{\delta}$-fiber units, appliction of All Bond 2 completely abolished the INA induced by 4M NaCl. Also, application of Scotchbond Multipurpose(SBMP) totally abolished the INA induced by 4M NaCl in 4 $A{\delta}$-fiber units. 3. Before the application of dentin bonding agent, outward dentinal fluid movement of $10.2{\pm}5.7\;pl{\cdot}s^{-1}{\cdot}mm^{-2}$ was obsered. But after the application of dentin bonding agent the movement of dentinal fluid was stopped. 4. The gap width of 2-$3{\mu}m$ was formed between exposed dentin and adhesive resin in the specimens applied with dentin bonding agents of All Bone 2 and SBMP. But the formation of hybrid layer and the penetration of resin into were dentinal tubules were not clearly observed in interface between dentin and adhesive resin.

  • PDF

Respiratory support with heated humidified high flow nasal cannula in preterm infants

  • Jeon, Ga Won
    • Clinical and Experimental Pediatrics
    • /
    • 제59권10호
    • /
    • pp.389-394
    • /
    • 2016
  • The incidence of bronchopulmonary dysplasia (BPD) has not decreased over the last decade. The most important way to decrease BPD is by weaning the patient from the ventilator as soon as possible in order to reduce ventilator-induced lung injury that underlies BPD, and by using a noninvasive ventilator (NIV). Use of a heated, humidified, high flow nasal cannula (HHHFNC), which is the most recently introduced NIV mode for respiratory support in preterm infants, is rapidly increasing in many neonatal intensive care units due to the technical ease of use without sealing, and the attending physician's preference compared to other NIV modes. A number of studies have shown that nasal breakdown and neonatal complications were lower when using a HHHFNC than when using nasal continuous positive airway pressure (nCPAP), or nasal intermittent positive pressure ventilation. The rates of extubation failure during respiratory support were not different between patients who used HHHFNC and nCPAP. However, data from the use of HHHFNC as the initial respiratory support "after birth", particularly in extremely preterm infants, are lacking. Although the HHHFNC is efficacious and safe, large randomized controlled trials are needed before the HHHFNC can be considered an NIV standard, particularly for extremely preterm infants.

'후지' 사과의 단기 저온저장 및 모의수출 과정에서 소포장의 천공도 조절 효과 (Perforation Adjustment of Unit Package for 'Fuji' Apples during Short-term Cold Storage and Export Simulation)

  • 김수정;박윤문;윤태명
    • 원예과학기술지
    • /
    • 제32권2호
    • /
    • pp.184-192
    • /
    • 2014
  • '후지' 사과의 단기 저장과 모의 수출 과정에서 소포장 적용이 중량감소와 품질에 미치는 영향을 분석하기 위해 2년에 걸쳐 포장의 밀폐도를 단계적으로 조절하는 실험을 수행하였다. 포장의 밀폐도는 천공 처리 수준(무천공, 펀치 홀, 핀홀)과 밀봉 방식(끈 묶음, 열 접착)을 달리하여 조절하였다. 수확 후 사과를 $40{\mu}m$ 폴리프로필렌 필름 포장 봉지에 5개씩 담아 $0^{\circ}C$에서 4주 저장한 후, 1년차 예비실험에서는 바로 상온유통 과정을 거쳤고 2년차 본 실험에서는 2주간의 냉장 컨테이너 수출 운송과 현지 상온 유통 7일의 모의 수출 과정을 거쳤다. 천공 처리 없이 끈 묶음 혹은 열 접착한, 비교적 높은 수준의 밀폐 소포장에서는 이산화탄소 축적에 의한 내부갈변 증상이 발현되었다. 이에 비해 천공 처리 필름 소포장에서의 MA 환경조성은 핀홀 처리 소포장에서만 관찰되었고, 모든 처리에서 내부갈변 장해는 발생하지 않았다. 밀폐도가 낮은 펀치 홀 천공 처리 필름 소포장에서도 단기 저장 후 모의 수출 과정에서 중량 감소를 줄이는 효과가 나타났으나 과일의 이화학 품질에 미치는 영향은 미미하였다. 천공도를 낮춘 핀홀 처리 역시 이화학 품질 유지 효과는 없었으나 조직감 관능 유지에 효과가 있는 것으로 나타났다. 따라서 사과의 단기저장과 수출과정에 소포장 기술을 적용할 때 MA 조성을 통한 품질유지 효과를 높이기 위해서는 펀치 홀 천공보다는 훨씬 미세한 천공 처리의 필요성이 제시되었다.