• Title/Summary/Keyword: Sealing Technique

Search Result 111, Processing Time 0.028 seconds

Dependence of Xe Plasma Flat Fluorescent Lamp On the Electrode Gap and Dielectric Layer Thickness

  • Kang, Jong-Hyun;Lee, Yang-Kyu;Heo, Sung-Taek;Oh, Myung-Hoon;Lee, Dong-Gu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1519-1521
    • /
    • 2007
  • In this work, a coplanar-type plasma flat fluorescent lamp having cross type of electrode was fabricated by screen printing and sealing technique. Cross type of electrode with a dielectric layer were screen-printed on a rear glass plate, and then fired at $550^{\circ}C$. Phosphor was printed on and fired at $450^{\circ}C$. Finally, the lamp was sealed by frit glass at $450^{\circ}C$. The lamp of cross electrode type was studied depending on the electrode gap and the thickness of dielectric layer.

  • PDF

Resonant Loop Design and Performance Test for a Torsional MEMS Accelerometer with Differential Pickoff

  • Sung, Sang-Kyung;Hyun, Chul;Lee, Jang-Gyu
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.1
    • /
    • pp.35-42
    • /
    • 2007
  • This paper presents an INS(Inertial Navigation System) grade, surface micro-machined differential resonant accelerometer(DRXL) manufactured by an epitaxially grown thick poly silicon process. The proposed DRXL system generates a differential digital output upon an applied acceleration, in which frequency transition is measured due to gap dependent electrical stiffness change. To facilitate the resonance dynamics of the electromechanical system, the micromachined DRXL device is packaged by using the wafer level vacuum sealing process. To test the DRXL performance, a nonlinear self-oscillation loop is designed based on the extended describing function technique. The oscillation loop is implemented using discrete electronic elements including precision charge amplifier and hard feedback nonlinearity. The performance test of the DRXL system shows that the sensitivity of the accelerometer is 24 Hz/g and its long term bias stability is about 2 mg($1{\sigma}$) with dynamic range of ${\sigma}70g$.

High resolution 5" full color field emission displays with new aging technique

  • Kim, J.M.;Hong, J.P.;Park, N.S.;Ryu, Y.S.;Jung, J.E.;Hong S.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.23-23
    • /
    • 1998
  • High resolution field emission dispplay(FED) devices of 5 inch diagonal in size are fully developped for the applications of near-future flat ppanel dispplays. Under the unique gate-switching drive scheme electron trajectory pprofiles are simulated and tested by considering leakage effects of each ppixel. Uniquely-pprinted sppacer with high asppect ratio are fabricated on real ITO glass for high vacuum ppackaging. In addition new gas aging scheme of stabilizing field emitting array are extensively investigated during the sealing and exhausting pprocess in order to pprevent oxidation effects on the micro tipp. Finally fulll color images of 64 gray scale will be demonstrated.

  • PDF

Three-Dimensional Contact Stress Analysis for Structural Design of Bolted Joint Assembly of Pressure Vessels in Nuclear Power Plants (원자력 발전소용 압력용기의 볼트 연결 조립부 구조설계를 위한 3차원 접촉 응력 해석)

  • Lee, Boo-Youn;Kim, Tae-Woan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.122-128
    • /
    • 1999
  • Bolted joint assembly for nuclear power plants consists of various components : cover plate, retainer plate, manway flange, gasket and stud bolts/nuts. To guarantee the soundness of the joint, it is important to prevent leakage through the gasket and reduce the stress concentration factor at the thread root. In this paper, Submodeling technique for the finite element method is proposed to accurately compute three dimensional contact stresses which govern the sealing performance and the maximum contact stresses at the threads root. For verification of global solutions used as boundary conditions of submodel solution, the stresses on the cover plate and the manway flange are measured by strain gages when internal pressure is applied to the bolted joint assembly. The numerical results are compared with the experimental results.

  • PDF

An effect of Dentin Bonding Procedure on the Shear Bond Strength of Resin Cement to Porcelain Restoration (도재 수복물 합착시 상아질 접착 술식이 레진 시멘트의 전단결합강도에 미치는 영향)

  • Kang, Hae-Jin;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.67-78
    • /
    • 2012
  • The purpose of this study was to determine whether there were differences in shear bond strength to human dentin using IDS technique compared with DDS. Forty freshly extracted human molars were and devided into 4 groups. The control group specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent and cemented with resin cement. The IDS/SE(immediate dentin sealing, Clearfil$^{TM}$ SE Bond) and IDS/SB (immediate dentin sealing, Adapter$^{TM}$ Single Bond 2) specimens were, on the morrow of tooth preparation, light-cured after application of dentin bonding agent(Clearfil$^{TM}$ SE Bond and Adapter$^{TM}$ Sing Bond 2, respectively), whereas DDS specimens were not treated with any dentin bonding agent. IDS/SE, IDS/SB and DDS specimens were thermocycled. Following that delay, specimens were cemented with resin cement. The dentin bonding agent was left unpolymerized until the application of porcelain restoration. Shear bond strengths were measured using a universal testing machine. Specimens also were evaluated for mode of fracture using an optical microscope. The mean shear bond strengths of control group and IDS/SE groups were not statistically different from one another. The bond strength of IDS/SE group had a significantly higher mean than that of DDS group. There was no significant difference in the mean shear bond strength between IDS/SB(4.11MPa) and DDS group. The evaluation of failure modes indicates that most failures in the control group and IDS/SE groups were mixed, whereas failures in the DDS group were interfacial. When preparing teeth for indirect ceramic restoration, IDS with Clearfil$^{TM}$ SE Bond results in improved shear bond strength compared with DDS.

Development of an environmentally friendly precipitation treatment system utilizing open space in residential estates (주거단지의 외부공간을 활용한 친환경적 우수처리 시스템 개발)

  • Lee, Eun-Heui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.3
    • /
    • pp.55-65
    • /
    • 2001
  • The hydrological cycle system in the city is generally characterized by quick runoff, bad infiltration, low evaporation rate, and so on. It is caused by sealing greens up with pavements. Also, there are lots of contradictory environmental problems, such as inundation, the lack of underground water and dryness in the city, caused by the urban drainage system which is mostly focused on the quick draining off rainfall. In addition, the technique joining rain and sewage, which has more dangers of inundation, occupies 66% between two Korean drainage systems which consist of joining and dividing system. There has been some need to convert the present drainage system into the environmentally friendly hydrological cycle system. This is a theoretical study to examine some foreign cases and suggested applicable methods in our country, focusing on the environmentalyl friendly system of rainfall drainage. The precipitation treatment system can be made up of some possible phases choosing from premanagement, utilization, infiltration, retention, and inducement phases. Therefore, this study mostly focused on infiltration, retention, and inducement phases. It is necessary to suggest the multifunctional utilization of outdoor spaces, especially applying in new constructing and re-constructing residential estates.

  • PDF

Development of 22,000Ton Hydraulic Press for the Forming of Heat Plate with Ultra-Large Size (초대형 열교환기용 열판 성형을 위한 22,000Ton급 유압 프레스 개발)

  • Lim S. J.;Park H. J.;Yoon D. J.;Kim E. Z.;Lim H.;Na K. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.166-169
    • /
    • 2001
  • 22,000 Ton hydraulic press was developed using wire winding method. The hydraulic press consists of three piece of frame type. The outer layers of yoke-column frame and main cylinder linear were wound with piano wire(1mm${\times}$4mm) under controlled tension and the total length of wound wire was about 450Km. The developed hydraulic press is used for the forming of heat plate with ultra-large size. To obtain large force with relative small apparatus, high pressure of $1,500 Kgf/cm^2$ was supplied to main cylinder through pressure amplification by booster pump. Therefore sealing technique of main cylinder is so crucial that the seals were made of mitre ring type with super-elastic metal. The press total weight is about 150 tons, which is quite light and compact relative to that of conventional hydraulic press.

  • PDF

Which is the proper insertion method of laryngeal mask airway according to the rescuer's position? : Comparison between index finger insertion and thumb insertion (구조자의 위치에 따른 적절한 후두마스크기도기 삽입방법은 무엇일까? : 검지손가락법과 엄지손가락법의 비교)

  • Chun, Kyoung-Ha;Moon, Jun-Dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.3
    • /
    • pp.7-16
    • /
    • 2017
  • Purpose: The purpose of the study was to investigate the effects of laryngeal mask airway (LMA) insertion from different positions, using different methods, on the quality of the insertion, for identifying a more convenient and effective insertion method. Methods: In a model ambulance, 30 paramedic students performed the LMA insertion procedure, in four different settings, combinations of the rescuer's position (at the head end of the patient, at the side of the patient), and insertion technique (index finger insertion, thumb insertion), in a randomized order. Quality of insertion index and convenience of use were measured. Results: The quality of insertion index (tidal volume, gastric insufflation, airway pressure, airway sealing pressure, midline positions, insertion success grade, and insertion time) were not significantly different among four different settings. However LMA insertion from the anterior (head) end, using the index finger method compared to the thumb method was found to be significantly more convenient. Conclusion: We recommend using the more convenient and familiar LMA insertion method, between index finger insertion and thumb insertion, regardless of rescuer's position.

Nanochannels for Manipulation of DNA Molecule using Various Fabrication Molecule

  • Hwang, M.T.;Cho, Y.H.;Lee, S.W.;Takama, N.;Fujii, T.;Kim, B.J.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.4
    • /
    • pp.254-259
    • /
    • 2007
  • In this report, several fabrication techniques for the formation of various nanochannels (with $SiO_2$, Si, or Quartz) are introduced. Moreover, simple fabrication technique for generating $SiO_2$ nanochannels without nanolithography is presented. By using different nanochannels, the degree of stretching DNA molecule will be evaluated. Finally, we introduce a nanometer scale fluidic channel with electrodes on the sidewall of it, to detect and analyze single DNA molecule. The cross sectional shape of the nanotrench is V-groove, which was implemented by thermal oxidation. Electrodes were deposited through both sidewalls of nanotrench and the sealing of channel was done by covering thin poly-dimethiysiloxane (PDMS) polymer sheet.

Conversion of Fisheye Image to Perspective Image Using Nonlinear Scaling Function (비선형 스케일링 함수를 이용한 어안 영상의 원근 변환)

  • Kim, Tae-Woo;Cho, Tae-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.117-121
    • /
    • 2009
  • The fisheye image acquired with a fisheye camera has wider field of view than a general use camera. But large distortion of the object in the image requires conversion of the fisheye image to the perspective image because of user's difficult perception. The existing Ishii's method[1] has the problem that the object can has sire and geometrical distortion in the transformed image because it uses equidistance projection. This paper presented a conversion technique of the fisheye image to the perspective image using sealing function. In the experiments, it was shown that our method reduced size and geometrical distortion by applying the scaling function.