• Title/Summary/Keyword: Sealing Material

Search Result 306, Processing Time 0.026 seconds

Hydrostatic Pressure Resistance Performance Testing of Cement Mixed Siliceous Powder Waterproofing Coationgs (규산질계 분말형 도포방수재의 내투수성 성능평가 연구)

  • Park, So-Young;Kwon, Si-Won;Kim, Soo-Yeon;Kim, Byong-il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.31-32
    • /
    • 2018
  • Lately, cement mixed siliceous powder waterproofing coating has been used as a waterproofing material in the wet environment condition of an underground concrete structure. Underground is exposed to environmental influences such as pressure of ground water, pressure of soil. However, the quality standard for pressure (water pressure, earth pressure) is not specified in the specification of the cement mixed siliceous powder waterproofing coating. Therefore, in this study, the permeability test was carried out based on the assumption that the durability should be verified in consideration of the environmental aspects of the material in actual field. As a result of the test, the permeability was generated from the inorganic single type material, but it was caused by the sealing failure and the test error, and the permeability was not generated in most of the materials. The results of this study will be analyzed by reviewing the physical properties of the material, and the research direction will be resumed.

  • PDF

Biocompatible Material Design Minimizing Hypertrophic Injury and Treatment Effects using a Mini-pig (비대성 흉터를 최소화하는 생체적합성 재료설계와 미니돼지에 대한 치료 효과)

  • Kim, Yong-Hwan;Kim, Jong-Woo;Jin, Seong-Hun;Kim, I-Su;Kang, Myung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.6
    • /
    • pp.95-100
    • /
    • 2017
  • Recently, biomedical-grade texture material gauze has often been used to treat wounds. At this time, it is difficult to remove scratches and pushed gauze; if you remove it with force, the tissue may separate and bleeding may occur again. In this study, we studied a method to apply medical-grade silicone material. Similar to the research result that hypertrophic wounds reduce the thickness of scar marks. Through mini-pig experiments, we evaluated the effects on scar treatment. The test results showed that the silicone cover layer applied to the wound site had a sealing effect on the wound area, skin temperature, and histopathological examination. In conclusion, gel treatment utilizing a biocompatible substance had the effect of minimizing hypertrophic scars.

Performance of Polymer Suspension Insulator with Shed Profile (갓 형상에 따른 폴리머 현수애자의 열화특성)

  • Cho, H.G.;Lee, U.Y.;Kang, S.H.;Lim, K.J.;Yeo, H.G.;Ji, W.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.539-542
    • /
    • 2003
  • Recently, the polymer insulators which are being used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination which lead to the well known phenomenon of dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. The shape design of porcelain insulator is formalized but design standard for polymer insulator is no standardized up to now, much research is necessary in real condition. In this paper, the aging property of polymer insulator with shed shape(regular, alternative type) is analyzed through numerical analysis, CEA(canadian electricity association) tracking wheel test and IEC 61109 Annex C.

  • PDF

Fabrication and properties of Xe plasma flat fluorescent lamp (LCD Backlight용 FFL(Flat Fluorescent Lamp)의 제작 및 특성 연구)

  • Kang, Jong-Hyun;Lee, Yang-Kyu;Heo, Sung-Taek;Oh, Myung-Hoon;Lee, Dong-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.431-432
    • /
    • 2007
  • In this study, we used screen printing on the rear glass with silver electrodes, phosphor and a dielectric which is on the silver electrodes, and carried out firing in the temperature of $550^{\circ}C$, $570^{\circ}C$, $450^{\circ}C$ each. To seal the rear and top glass together, we used crystalline frit paste as a sealing material with dispenser and carried out firing up to $450^{\circ}C$. As using this panel, we focused on optimizing the condition which influences characteristics of discharging by the distance between electrodes, electrode structure, type and pressure of gases for FFL.

  • PDF

Sealing Ability of Three Different Materials Used as Retrograde Filling

  • Park, Ji-Hoon;Kang, Seung-Bok;Choi, Yong-Hoon;Bae, Ji-Hyun
    • Journal of Korean Dental Science
    • /
    • v.5 no.2
    • /
    • pp.60-67
    • /
    • 2012
  • Purpose: To test the apical leakage prevention performance of three different materials through protein leakage procedures using bovine serum albumin (BSA) and Bradford protein reagent. Materials and Methods: A total of 60 human single-rooted teeth were divided into 4 groups, and conventional root canal filling was done. The root was cut 3 mm from the apex, and a cavity was formed. Proroot MTA (MTA), Fuji II LC (GI), Fuji II LC with XP bond (GIA), and Caviton (CA) were used as experimental materials to fill the cavity in a retrograde filling manner. The extent of BSA leakage was then measured with a ultraviolet visible spectrophotometer 24, 48, and 72 hours after filling. Result: After 24 hours, among the 15 teeth of each group, 2 in MTA, 4 in GI, 3 in GIA, and 7 in CA showed leakage. After 48 hours, 3 in MTA, 5 in GI, 5 in GIA, and 10 in CA had leakage and discoloration. After 72 hours, among the 15 teeth of each group, 3 in MTA, 6 in GI, 5 in GIA, and 10 in CA showed leakage. The leakage in the CA group was greater than that in the MTA group at 48 and 72 hours based on Fisher's exact test (P=0.025), and the difference was statistically significant. Similarly, the leakage in the CA group was greater than that in the MTA group over time based on the Kaplan-Meier survival estimate (P=0.011), and the difference was statistically significant. Conclusion: Glass ionomer, glass ionomer after adhesive application, and MTA all showed leakage. Caviton showed greater leakage compared to MTA 48 and 72 hours after filling, and the difference was statistically significant; thus suggesting that Caviton is not appropriate as retrograde filling material considering its sealing ability.

A Study on the sealing Characteristic of Automobile Waterproof Connector (자동차용 방수커넥터의 밀봉특성에 관한 연구)

  • Ko, Young-Bae;Park, Hyung-Pil;Lee, Jeong-Won;Cha, Baeg-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.1859-1864
    • /
    • 2014
  • Liquid silicone rubber(LSR) has been applied to various products such as electronic devices owing to its excellent thermal and chemical resistance. Hyperelastic materials, however, have properties distinguished from general metal materials. Hyperelastic materials show elastic behaviors in the range of large deformation in which load has the nonlinear relation with deformation. In addition, they have characteristics of nonlinearity, incompressibility, in large scale. On account of such characteristics, there are many difficulties in design and production using these materials. In this study, the load-deformation relation obtained from tension and compression tests was applied to finite element analysis in order to design waterproof connectors for automobiles. Furthermore, the effectiveness of the finite element analysis was confirmed by comparing the results of analysis with those of performance tests.

Study on the Characteristics of Formaldehyde Emission from Wood-Based Panels Treated with Several Surface Finishing Materials (표면마감처리에 따른 목질보드의 포름알데히드 방산특성에 관한 연구)

  • So, Won-Tek;Lim, Jin-Ah
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.30-37
    • /
    • 2006
  • The present study examined the formaldehyde (HCOH) emission characteristic of various wood-based panel used in interior design, and measured changes in formaldehyde emission when a number of VOC reduction methods were applied. Formaldehyde emission showed a clear tendency of increase with the rise of temperature, and the concentration of formaldehyde emitted changed according to the preprocessing condition before measuring. Formaldehyde emission from wood board after bake out treatment was lower than that of the control group. When specimens were coated with urethane, cashew, water, oil stain, they generally showed the decrease of formaldehyde emission, although varying according to finishing material, and when edge sealing was applied the decrease became significant. $TiO_2$ coating was more effective in decreasing formaldehyde under ultraviolet lamps than under ordinary lamps. When the irradiation of ultraviolet lamps gets longer, formaldehyde emission decreased.

A STUDY OF SEALING ABILITY OF DENTIN BONDING AGENT AS ROOT CANAL SEALER (Dentin Bonding Agent의 근관폐쇄(根管閉鎖) 효과(效果)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Min, Hyo-Kie;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.103-111
    • /
    • 1988
  • The purpose of this study was to, examine the sealing ability of the denting bonding agent, when used with gutta percha cone, as a root canal sealer. Seventy two upper and lower extracted human teeth with single root were randomly selected and instrumented in a conventional method with K-file. After instrumentation and dry the canal with paper point, there were divided into three groups and twenty four teeth in each group were filled with the following material; In group I: Scotchbond in combination with gutta percha cone. In group II: AH 26 in combination with gutta percha cone. In group III: Tubli-Seal in combination with gutta percha cone. All specimens were immersed in Indian Ink, decalcified, and cleared. The depth of dye penetration into the canals were evaluated by caliper at the intervals of 1 day, 1 week, 2 weeks. The results were as follows; 1. Depth of dye penetration for all groups increased with time. 2. As to difference in mean dye penetration at time interval of 1 day and 14 days, Scotchbond group exhibited the smallest value as 0.53mm and Tubli-Seal group exhibited the largest value as 0.70mm. 3. There was the difference of dye penetration between each group, but its difference was not significant, statistically.

  • PDF

EVALUATION OF THE SEALING ABILITY OF Microseal® OBTURATION TECHNIQUE (Microseal®을 이용한 근관충전법의 근관폐쇄능력 평가)

  • Oh, Tea-Seok;Yoo, Hyeon-Mee;Hwang, Hea-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.682-689
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of the Microseal$^{(R)}$, which was new obturation system made by Tycom company, U.S.A. Forty-five extracted single-rooted human teeth were resected at cemento-enamel junction and divided three groups. All canals were prepared using Profile system, and then each group was obturated by lateral condensation technique (group 1), vertical condensation technique (group 2) and Microseal$^{(R)}$ condensation technique (group 3) with root canal sealer. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$ and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were resected horizontally at 1 mm (level I), 2 mm (level II), 3 mm (level III) from the anatomical root apex using low speed microtome and examined with Image analyzer (IBASR, Zeiss co., Germany.) at ${\times}25$ magnification. The gab between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was expressed percentage by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (one-way ANOVA). The results were as follows; 1. The mean ratio of leakage (%) was 6.46% at group 1, 3.06% at group 2, 11.27% at group 3. 2. When evaluating the ratio of leakage at the three levels, there was level I> level II> level III in all groups. Especially, the difference between level I and level III was statistically significant (p<0.05). 3. When evaluating the ratio of leakage at the three groups, there was group 3> group 1> group 2 at all levels. Especially the difference between group 2 and group 3 was statistically significant (p<0.05).

  • PDF

HISTOPATHOLOGIC STUDY OF FURCATION PERFORATIONS REPAIRED WITH SOME MATERIALS (치근이개부 천공부위에 대한 수종수복재의 치유효과에 관한 조직병리학적 연구)

  • Hong, Han-Pyo;Hong, Chan-Ui;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.610-626
    • /
    • 1995
  • Perforations especially in the furcations during endodontic treatment have notably detrimental effect on prognosis. The purpose of this study was to compare radiographically and histologically the sealing ability and the tissue responses of amalgam, Ketac-Silver, IRM, Vitapex, and mineral trioxide aggregate(MTA) used to repair furcation perforations. Thirty two experimental furcation perforations were created in the mandibular premolars of 6 mongrel dogs and immediately repaired with experimental materials. The animals were sacrificed after 16 weeks and radiographic and histopathologic results were evaluated. The following conclusions were drawn within the limits of the experimental results; 1. All materials tested in this experiment revealed a certain degree of extrusion into the periodontal space. 2. Both amalgam and Ketac-Silver showed the greatest degree of inflammation and bone resorption(p<0.0001). There was no significant difference between the amalgam and Ketac-Silver groups. 3. Both IRM and Vitapex showed a markedly milder degree of inflammatin and less bone resorption than amalgam or ketac-siver(p<0.00005). both IRM and vitapex showed the same respone. 4. MTA showed the least degree of Inflammation and bone resorption(p<0.05). The results of this experiment indicate that among the different materials tested, MTA appeared to be the best material for sealing furcation perforations, although the radiographic and histopathologic differences between the MTA and Vitapex groups were not statistically significant. But further studies with a larger sample are needed to have the exact conclusions.

  • PDF