• Title/Summary/Keyword: Sea dredging ground

Search Result 4, Processing Time 0.018 seconds

Evaluation on Bearing Capacity of Dredging Ground by Field Loading Test (현장재하시험에 의한 준설토지반의 지지력 평가방법 연구)

  • Park, Jong-Beom;Ju, Jae-Woo;Kim, Jang-Heung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.1
    • /
    • pp.53-61
    • /
    • 2014
  • Sea gives us a lot of benefits and one of them is a role of transporting goods easily by ship. Accordingly the industrial area or the container yard is constructed either on the low sea or near the sea. Sea dredging ground is made by pumping them using dredge pump to the inside of embankment after dredging undersea soils. The dredging ground after pumping is in the slurry state but as time goes, consolidation by the own weight happens and evaporation happens at the surface of dredging ground. The evaporation causes the crest layer in the upper side of dredging ground. Under the crest layer there is still a soil of slurry state which has just little bearing resistance. This kind of characteristics makes it difficult to get a exact bearing capacity using the equations proposed until now. In this study we have performed simultaneously both the field loading tests and the cone penetration tests on the sea dredging ground. From the result of field tests, new experimental equation for the ultimate bearing capacity has been proposed. If we use the new equation, it is believed that some design of sea dredging ground could be more accurate.

Optimal Input Database Construction for 3D Dredging Quantification (3차원 준설물량 산출을 위한 최적의 입력DB 구축방안)

  • Gang, ByeungJu;Hwang, Bumsik;Park, Heonwoo;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.5
    • /
    • pp.23-31
    • /
    • 2018
  • The dredging project became more important with the recent construction of off shore structures and reclamation projects. Accordingly, more exact quantitative estimation of the dredged amount should be required. The sub-sea ground information can be obtained generally by the boring investigation and the dredged amount can be estimated based on the depth or the deeper bound of a ceratin layer via 3D visualization program. During the estimation process, the input DB should be constructed with 1D elevation information from boring investigation for the spatially approximated distribution of a deeper bound of each ground layer. The input DB can be varied with the application of the borings and the approximation targets. Therefore, the 3D visualized ground profile and dredged amounts are compared on the actively dredged sites, vicinity of Saemangeum area and outer port area in Gunsan with regard to the input DB construction methods. Conclusively, the input DB based on the spatially approximated depths show higher precision results and more reasonable 3D visualized ground profiles.

Plant Distributions and Physicochemical Characteristics of Topsoil on the Reclaimed Dredging Area (임해준설매립지 식물분포와 표층토양의 이화학적 특성)

  • Nam, Woong;Kwak, Young-Se;Jeong, In-Ho;Lee, Deok-Beom;Lee, Sang-Suk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.3
    • /
    • pp.52-62
    • /
    • 2008
  • By analyzing specific plant distributions and physicochemical characteristics of topsoil in a reclaimed dredging area, baseline data was found of natural landscape planting sites, and developing dredged fill ground. The reclaimed dredging area is five different stands (1, 2, 3, 4 and 5) which were examined in this research. They are located from sea level to 15 meters in altitude and exhibited typical characteristics of the salt marsh in Gwangyang Bay. Species with high constancy in the vegetation on the reclaimed soil were classified into four stages. A total of 12, 15, 22, 27 and 35 different plant species were found and also increased in stands 1, 2, 3, 4 and 5, respectively. Moving from stand 1 to 5, halophytes decreased and non-halophytes increased. Desalination at each stage of the reclaimed dredging area was a driving force affecting the performance and distribution of halophytes and non-halophytes. Overall, 35 quadrats of soil were selected and analyzed for specific physicochemical characteristics of topsoil between O${\sim}$20cm. Results of the physicochemical analysis such as altitude, slope, vegetation and kind of reclaimed dredging soil, exhibited irregular increases or decreases. As survey areas moved from stand 1 to 4, desalination areas, soil acidity, electric conductions, content of salinity, available phosphorus, potassium, chlorine, calcium, and magnesium indicated decreasing patterns; however, total nitrogen, silt, and clay content increased. Cluster analysis and PCA by environmental data within the stands clearly showed five distinct vegetation patterns on the tested reclaimed area. These results indicate that the differences of performance and distribution of vegetation are due to the SAR in the reclaimed soil and related to the natural survival strategy at the given hostile habitat.

Characteristic of a Soft Ground Behavior Subjected to Static and Dynamic Loads (A Study on the Model Test) (정하중 및 동하중이 작용하는 연약지반의 거동특성(비교모형실험))

  • Kim, Jong-Ryeol;Kang, Jin-Tae;Lee, Chi-Yeal;Part, Yong-Myun;Jeong, Jea-Hoon
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.1
    • /
    • pp.111-118
    • /
    • 2008
  • In the study a 2 dimensional model test was executed to grasp the effect of the taking load of equipments on the ground when improving a soft ground like dredging reclaimed ground. The static load and the dynamic load in the consolidated model ground was $0.02kg/cm^2,\;0.03kg/cm^2\;and\;0.04kg/cm^2$ respectively. After consolidating far two months by consolidation load of $0.02kg/cm^2,\;0.03kg/cm^2\;and\;0.04kg/cm^2$ respectively, the ultimate bearing capacity was $0.16kg/cm^2,\;0.19kg/cm^2,\;0.24kg/cm^2$ respectively. And the energy price of dynamic load test at the same point as the settlement of static load test indicated $E=336{\sim}945kg{\cdot}cm,\;E=252{\sim}780kg{\cdot}cm\;and\;E=323{\sim}727kg{\cdot}cm$ for each consolidation load. When the static load and the dynamic load operated at the same ground condition, the heaving quantity was bigger in the case of the dynamic load than in the case of the static load, and the horizontal displacement quantity the in the case of dynamic load was exhibited very deficiently compared to the quantity in the case of static load test.