급탕기용 열펌프를 위한 $CO_2$ 스크롤 압축기 최적설계에 관한 연구 (Optimum Design of $CO_2$ Scroll Compressor for Heat Pump Water Heater)

  • 김현진;안기정;김철우
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.241-249
    • /
    • 2004
  • A parametric study on the scroll wrap configuration factors of a $CO_2$scroll compressor for heat pump water heater has been carried out. Since there are 7 scroll wrap design parameters and 5 equations relating them, two of the design parameters can be selected as independent parameters. In this study, the wrap thickness and orbiting radius are chosen as independent ones. Computer simulation program has been used to estimate the compressor performance at various combinations of the scroll wrap design parameters. It has been found that there exists optimum combination of the wrap parameters for the highest compressor performance over analyzed ranges of the design parameters.

Determination of an Optimum Orbiting Radius for an Oil-Less Scroll Air Compressor

  • Kim, Hyun-Jin;Lee, Yong-Ho;Kwon, Tae-Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권4호
    • /
    • pp.124-129
    • /
    • 2008
  • Design practice has been made on an oil-less scroll air compressor as an air supply device for a 2 kW fuel cell system where air pressure of 2 bar and flow rate of 120 liter/min are required. Basic structure of the scroll compressor includes double-sided scroll wrap for the orbiting scroll driven by two crankshafts connected to each other by a timing belt. These features can eliminate thrust surface which otherwise would produce frictional heat and jeopardize reliable operation of the orbiting scroll and the scroll element's deformation as well. This study focuses on optimum scroll wrap design; orbiting radius has been chosen as an independent design parameter. As the orbiting radius changes, scroll sizes such as scroll base plate and discharge port diameters change accordingly. Gas compression-related losses and mechanical loss also change with the orbiting radius. With a scroll base plate diameter of 120mm at most and discharge port of at least 10mm, the orbiting radius should be within the range of 2.5-4.0mm. With this range of the orbiting radius, it was estimated by performance analysis that the compressor efficiency reached to a maximum of ${\eta}_c$=96% at the orbiting radius of $r_s$=3.5mm for the scroll wrap height-to-thickness ratio of h/t=5.

소형 냉장고에 대한 스크롤 압축기 적용성에 관한 연구 (A Study on the Applicability of a Scroll Type Compressor to Small Capacity Refrigerators)

  • 김유찬;김우영;김현진
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.164-173
    • /
    • 2012
  • To study the applicability of a scroll type compressor to small capacity refrigerators, a R600a scroll compressor with algebraic scroll wrap has been designed. Its size and performance have been compared to a reciprocating type of the same displacement volume. By employing scroll wrap based on algebraic curve, high compression ratio can be accomplished without increasing the wrap angle much so that compact scroll may be obtained. Compared to a reciprocating one, the designed scroll compressor has diameter and height reduced by about 50% and 80%, respectively. By numerical simulation, it has been estimated that the scroll compressor provides 38.6% more cooling capacity than reciprocating type with 8.9% more power consumption, resulting in 27.3% increase in COP for ASHRAE low back pressure condition. With increasing the operating pressure ratio from 9.5 to 15.3, the overall compressor efficiency of the scroll compressor decreases from 72.6% to 65.2%, while that of the reciprocating compressor increases from 55.7% to 59.8%.

연료전지용 스크롤 공기압축기 개념설계 (Conceptual Design of the Scroll Air Compressor for Fuel Cell)

  • 권태훈;안종민;김현진;심재휘
    • 설비공학논문집
    • /
    • 제20권2호
    • /
    • pp.113-120
    • /
    • 2008
  • Potential application of the scroll type machine to air compressor for fuel cell has been studied. Among the seven configuration factors which determine scroll wrap profile, the wrap thickness and the orbiting radius were chosen as two independent variables to generate various scroll wrap profiles. A conceptual design practice was conducted for scroll air compressor for SOFC with power output of 2 kW. With larger wrap thickness and orbiting radius, base plate area of the orbiting scroll becomes smaller, so is the axial gas force acting on the base plate, resulting in reduced thrust loss in spite of larger friction velocity. Performance analysis on the designed model showed that its total efficiency was 64.4% with the mass flow rate per unit compressor input of 0.00905 kg/(s kW) for the wrap thickness of 3.5 mm and the orbiting radius of 3.0 mm.

공기구동 스크롤 팽창기 성능특성에 관한 실험적 연구 (Experimental Study on Performance Characteristics of Air Driven Scroll Expander)

  • 송원빈;곽철우;김태균;김주영;김광호
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.50-54
    • /
    • 2016
  • The performance of a scroll expander is the most important factor for the efficiency of small scale Organic Rankine cycle waste heat power generation systems. In this research, a scroll compressor was purchased and operated in reverse to function as a scroll expander. With air as a working fluid, a series of performance test were conducted on this expander by varying the inlet and outlet pressure. Secondly, We have tested through 2000 to 3500 rpm rotational speed to find the maximum power and efficiency of the expander. And last, It was observed in the initial experiments that the design of the expander's orbiting scroll wrap partially blocked the fluid intake which may have caused unnecessary flow resistance. To verify this theory, a small part of the scroll wrap was removed and the performance test was redone. It was observed that the lower back pressure assure the higher efficiency and power of expander and the rotational speed that shows maximum adiabetic efficiency of scroll expander is 69% at 2500 rpm. And by modified wrap of the scroll, we could get volume flow rate for 13% to 19% and power for 5% to 18% increased. But the maximum efficiency of the modified scroll was decreased 8%.

스크롤 압축기에서 축방향 순응하는 고정부재의 안정성 (Stability of the axially compliant fixed scroll in scroll compressors)

  • 김현진;이원학
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.93-103
    • /
    • 1997
  • This study presents a way of improving the stability of fixed scroll in scroll compressors. For the scroll compressor whose fixed scroll is designed to move in the axial direction for the axial compliance, the fixed scroll is under the influence of the overturning moment produced by internal gas forces. Unless the overturning moment is properly compensated by the moments of reaction forces at the suspension of the fixed scroll to the compressor frame, the fixed scroll would exhibit wobbling motion, increasing gas leakage through the gap induced by the wobbling of the fixed scroll between the two scroll members. The conditions on which the wobbling motion can be suppressed have been found analytically; The axial position of the fixed scroll suspension should be made within a certain range. The upper limit of this range is the axial location for the o-rings which are inserted between the fixed scroll and the back pressure chamber to promote sealing for the gas in the back pressure chamber. And the lower limit is mainly determined by the magnitude of the axial sealing force. As long as the axial sealing force is not negative over all crank angles, the lower limit is not above the mid-height of the scroll wrap. Larger axial sealing force lower the lower limit.

  • PDF

열변형을 고려한 스크롤 압축기의 누설 해석에 관한 연구 (A Study on the Leakage Analysis of Scroll Compressor with Thermal Deformation Considered)

  • 구인회;박진무
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2428-2437
    • /
    • 2000
  • In general, it is known that the portion of leakage loss is more than 20 % of total loss in scroll compressor. So far many studies have been done to improve the leakage problem and volumetric efficiency. In order to do this it is necessary that the leakage is exactly evaluated for conventional scroll model. Almost all studies that have been done were assumed that the clearance remains constant while operating. But in actual operating conditions, scroll wrap is deformed due to elevated refrigerant gas temperature. And this makes the leakage clearance change, so the leakage mass flow and the volumetric efficiency are also changed. In this study we assumed the steady state operating condition and obtain the average temperature and convection heat transfer coefficient in terms of involute angle. With these results, using finite element method we analyzed the heat transfer of scroll wrap, then did thermal deformation analysis. Then we obtain the leakage clearance and do the leakage and volumetric efficiency analysis. Compared with undeformed feature, we examine the effect of the thermal deformation on the leakage. The results say that the leakage mass flow for the case of considering thermal deformation is less than that for the unconsidered one, and this means that the leakage clearance is reduced due to thermal deformation.

가열구조를 갖는 스크롤 팽창기와 이를 이용한 분산발전 시스템 (Scroll Expander with Heating Structure and Their Systems for Distributed Power Source)

  • 김영민;신동길;이장희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.225-231
    • /
    • 2004
  • Scroll compressor has been used extensively for refrigeration since the early 1980's for its improved efficiency, greater reliability, smoother operation, lower noise and vibration. And also, nowadays, the scroll mechanism is used for expander even though in niche market yet. But scroll expander has not been used for high-temperature and high-pressure gas, because the continuous expansion of the gas causes a wide range of temperature distribution over the whole scroll wrap that leads to differential thermal expansion of scroll elements, which results in system vibrations, noise and efficiency losses. For the scroll expander to produce power more efficiently, all of radial and radial clearances between scroll wrap must be the same. In order to reduce differential thermal expansion in addition to improvements in thermal efficiency and specific power, we propose a scroll expander with heating structure. Heat-pipe heating structure is considered as the most effective method to heat the scroll expander at a uniform temperature. This paper includes some results of preliminary study of the scroll expander with heating structure and proposals of their systems for power generation and refrigeration.

  • PDF

준 1차원 누설모델링 및 열전달 손실을 고려한 스크롤압축기의 성능해석 (Performance analysis of a scroll compressor considering quasi one-dimensional leakage modeling and heat transfer loss)

  • 강태규;박경우;정연구;박희용
    • 대한기계학회논문집B
    • /
    • 제21권10호
    • /
    • pp.1339-1349
    • /
    • 1997
  • A numerical method of calculating the performance of a scroll compressor for refrigerant R-22 and R-134a is presented in this paper. A series of involute curves are employed for the scroll wrap design and the compression volume is investigated geometrically. The radial leakage flow rate through tip clearance is calculated by the two-dimensional compressible flow. On the basis of the results, quasi one-dimensional leakage modeling can be applied to the performance analysis of a scroll compressor, more effectively. Furthermore, the heat transfer effect between scroll wrap and working fluid in compression chamber is considered for the performance analysis. As the results of this study, the effects of the radial and tangential leakage flow rate and heat transfer on the scroll compressor performance are derived precisely. These results may provide the guideline for the design and development of a real scroll compressor.

비대칭 랩 스크롤 압축기의 바이패스 밸브 설계에 관한 연구 (A study on the by-pass valve design of a scroll compressor with asymmetric wrap)

  • 최진섭;곽상호;김현진
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.181-189
    • /
    • 2000
  • The scroll compressor used for heat pump has a wide range of operation condition. To cover both heating and cooling modes, the operating Pressure ratio ranges from 1.5 to 6.8. Since the scroll compressor, however, is a type of compressor whose pressure ratio is fixed, some loss in the compression work is caused by the operation at the pressure ratio different from the built-in pressure ratio. A way of avoiding this problem is to introduce by-Pass holes in compression chambers, so that the compressed gas of pressure higher than the discharge pressure, yet not reached to the discharge port can be released earlier through the by-Pass holes. In this paper, an optimum Positioning of the by-Pass hole and the effect of the by-pass valve on the compressor performance are studied.

  • PDF