• 제목/요약/키워드: Screw type

검색결과 547건 처리시간 0.027초

Air-Water Two-phase Flow Patterns and Pressure Distributions in a Screw-type Centrifugal Pump

  • Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권8호
    • /
    • pp.1203-1210
    • /
    • 2004
  • It was reported recently that the pump head degradation near the best efficiency point from single-phase flow to the break-down due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. In this paper, I carried out internal pressure measurements and visualizations, and investigated the various physical phenomena occurring inside a screw-type centrifugal pump operated in air-water two-phase flow. The results could give some characteristics about the degradation of pump performance on air-water two-phase flow.

대체에너지 사용시 공업용수 순환 개선을 위한 연구 (Study of industrial water calculation improvement by use Alternative Energy)

  • 최도순
    • 한국정보전자통신기술학회논문지
    • /
    • 제4권4호
    • /
    • pp.307-310
    • /
    • 2011
  • 이 논문은 1년에 몇 일 혹은 몇 시간 동안 만 최대 에너지가 공급된다. 그러므로 일반적인 경우에는 대부분 최대 에너지의 50%나 이보다 적은 양의 에너지를 얻게 된다. 이런 작은량의 에너지가 공급되는 Alternative Energy system (P. Voltac System)하에서 용수공급을 위해 기존의 Centrifugal pump를 사용 할 때와 Screw type pump를 사용할 때 공급된 용수량을 비교하였다. 연구 결과 Screw type pump 사용 시 alternative Energy system의 높이에 상관없이 단지 Screw type pump의 speed에 영향을 받으며 낮은 Energy 하 에서도 비교적 높은 효율을 낸다는 것을 실험적으로 비교 검토 하였다.

Resin Transfer Molding을 이용한 공기 압축기용 스크류로터 제작에 관한 연구 (A Study on the Manufacturing of Screw Rotors for Air-Compressors Using RTM Process)

  • 서정도;이대길
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.139-142
    • /
    • 1999
  • Screw rotors are core parts of screw type air compressors, compressors in refrigerating machines and super chargers of automobiles etc. They are composed of a female and a male rotors which have complex section profiles and helically swept geometry. Screw type compressors have advantages of low noise, high efficiency, less needs in maintenance etc. Usually, machining process of screw rotors requires long machining time using CNC machine designed only for screw rotors, which increase the cost of production. In this work, the screw rotors for air-compressors were manufactured with fiber reinforced epoxy composite materials by resin transfer molding process. The mold for the RTM process was made of aluminum and silicon rubber and was designed for release of helical shape products. Composite screw rotors, manufactured by RTM process, have advantages of lightweight, less cost of production, good characteristics of vibration etc.

  • PDF

CFD에 의한 수직형 정수처리 실증시설 내 압력식 오존접촉조 성능개선에 관한 연구 (Study on performance improved design of pressure-type ozone contactor in multistorey water treatment plant by CFD)

  • 최종웅;김성수;김정현;김관엽
    • 상하수도학회지
    • /
    • 제28권4호
    • /
    • pp.431-440
    • /
    • 2014
  • The ozonation process has been widely used for drinking water disinfection around the world. Recently, the pressurized ozone contactor, in which the side stream typed ozone injection method is installed, has been applied to water treatment system. In this study, numerical calculations were conducted to compare prototype and screw-type ozone contactors based on hydraulic effectiveness in more details. The prototype ozone contactor was already installed and operated in domestic water treatment plant, and the screw-type is the suggested one for improving ozone contact efficiency installing the screw plate to the prototype. Screw turn numbers of screw plate were changed as 3, 5, 7 and 9, respectively for numerical simulation. The CT(concentration of disinfectant in mg/L times time in minutes) value was considered as one of the options for evaluating disinfection ability. From the results, it could be concluded that the performance of the screw-type is higher than that of the protype contactor by controlling the variable T as the tracer time. Also, Morill index of the screw-type(turn numbers = 5 ) appeared to be lower than the other.

역극성 전압인가와 나사형 전극을 이용한 복합방전형 오존발생기의 특성 (The Characteristics of the Complex Discharge Type Ozonizer using Applied Voltage of a Inverse-Polarity and a Screw Type Electrode)

  • 송현직
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.80-85
    • /
    • 2011
  • In this paper, complex discharge type ozonizer with a screw type electrode has been designed and manufactured for environmental improvement using low power and high efficency ozoniazer. The complex discharge type ozonizer is equipped with three electrodes{central electrode(CE), internal electrode(IE) and external electrode(EE)}. Ozone of the complex discharge type ozonizer is generated by superposition of silent discharge and surface discharge in discharge space as a screw type CE and IE are respectively applied to AC high voltage of inverse-polarity has $180[^{\circ}]$ phase difference, EE is common electrode. In this time, when oxygen has been used as supplied gas, the maximum values of ozone concentration, ozone generation and ozone yield were obtained as 8,334[ppm], 3,249[mg/h] and 65.3[g/kwh].

Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study

  • Lee, Ki-Young;Shin, Kyung Su;Jung, Ji-Hye;Cho, Hye-Won;Kwon, Kyung-Hwan;Kim, Yu-Lee
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권2호
    • /
    • pp.133-142
    • /
    • 2020
  • Objectives: In this study, we determined the incidence and pattern of screw loosening in patients who received dental implants. Materials and Methods: Patients who received implants between January 2008 and October 2013 and completed their prosthetic rehabilitation were evaluated for the incidence, frequency, and onset of screw loosening using dental charts and radiographs. The association between each factor and screw loosening was analyzed using the chi-square test and a multivariate analysis with binary logistic regression models (P<0.05). Results: Total 1,928 implants were placed in 837 patients (448 males, 389 females), whose follow-up period after loading varied from 0.25 to 70 months (mean period, 31.5 months). Screw loosening occurred in 7.2% of implants. Most cases occurred less than six months after loading. Among those, 22.3% experienced recurrent screw loosening. Screw loosening was most common in the molar region (8.5%) and frequently associated with an implant diameter of ≥5 mm (14.2%). External implant-abutment connections (8.9%) and screw-retained implant prostheses (10.1%) showed higher incidence of problems than internal implant-abutment connections and cement-retained implants, respectively. Screw loosening was most common in implant prostheses with single crowns (14.0%). Conclusion: Within the limits of the current study, we conclude that the incidence of screw loosening differs significantly according to the position of implant placement, the type of implant and manufacturer, implant diameter, the type of implant-abutment connection, the type of retention in the implant prosthesis, and the type of implant prosthesis.

The effect of implant shape and bone preparation on primary stability

  • Moon, Sang-Hyun;Um, Heung-Sik;Lee, Jae-Kwan;Chang, Beom-Seok;Lee, Min-Ku
    • Journal of Periodontal and Implant Science
    • /
    • 제40권5호
    • /
    • pp.239-243
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effects of implant shape and bone preparation on the primary stability of the implants using resonance frequency analysis. Methods: Sixty bovine rib blocks were used for soft and hard bone models. Each rib block received two types of dental implant fixtures; a straight-screw type and tapered-screw type. Final drilling was done at three different depths for each implant type; 1 mm under-preparation, standard preparation, and 1 mm over-preparation. Immediately after fixture insertion, the implant stability quotient (ISQ) was measured for each implant. Results: Regardless of the bone type, the ISQ values of the straight-screw type and tapered-screw type implants were not significantly different (P>0.05). Depth of bone preparation had no significant effect on the ISQ value of straight-screw type implants (P>0.05). For the tapered-screw type implants, under-preparation significantly increased the ISQ value (P<0.05), whereas overpreparation significantly decreased the ISQ value (P<0.05). Conclusions: Within the limitations of this study, it is concluded that bone density seemed to have a prevailing effect over implant shape on primary stability. The primary stability of the tapered-screw type implants might be enhanced by delicate surgical techniques.

고정밀 이송을 위한 볼스크류용 체결기구의 특성에 관한 연구 (Characteristics of floating couplings of ball screw for high precision feeding system)

  • 김인찬;박천홍;정윤교;이후상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.610-614
    • /
    • 1996
  • As the run out error and misalignment of ball screw connected directly to guide table largely affect the motion accuracy of guideway, floating coupling that releases the table from screw nut except feed and rotational direction is needed todecrease its influences. The purpose of this study is to propose a practical model floating coupling of ball serew for high precision feeding system. The straightness, dynanic characteristics and micro step response of hydrostatic guideway, mounted with three types of coupling fixed type, leaf spring type and hydrostatic type, are tested and compared. From the resuts of experiments, it is proved that a hydrostatic type floating coupling is superior to other couplings and is available to high precision feeding system with ball screw.

  • PDF

Is All Anterior Oblique Fracture Orientation Really a Contraindication to Anterior Screw Fixation of Type II and Rostral Shallow Type III Odontoid Fractures?

  • Cho, Dae-Chul;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권6호
    • /
    • pp.345-350
    • /
    • 2011
  • Objective : It is debatable whether an anterior oblique fracture orientation is really a contraindication to anterior odontoid screw fixation. The purpose of this study was to investigate the feasibility of anterior odontoid screw fixation of type II and rostral shallow type III fracture with an anterior oblique fracture orientation. Methods : The authors evaluated 16 patients with type II and rostral shallow type III odontoid fracture with an anterior oblique fracture orientation. Of these 16 patients, 8 (group 1) were treated by anterior odontoid screw fixation, and 8 (group 2) by a posterior C1-2 arthrodesis. Results : Of the 8 patients in group 1, seven patients achieved solid bone fusion (87.5%), and one experienced screw back-out of the C-2 body two months after anterior screw fixation. All patients treated by posterior C1-C2 fusion in group 2 achieved successful bone fusion. Mean fracture displacements and fracture gaps were not significantly different in two groups. (p=0.075 and 0.782). However, mean fracture orientation angles were $15.3{\pm}3.2$ degrees in group 1, and $28.6{\pm}8.1$ degrees in group 2 (p=0.002), and mean fragment angulations were $3.2{\pm}2.1$ degrees in group 1, and $14.8{\pm}3.7$ degrees in group 2 (p=0.001). Conclusion : Even when the fracture lines of type II and rostral shallow type III fractures are oriented in an anterior oblique direction, anterior odontoid screw fixation can be feasible in carefully selected patients with a relatively small fracture orientation angle and relatively small fragment angulation.

제 II 형 치상돌기 골절에서 전방경유 나사못 고정술 (Anterior Screw Fixation of Type II Odontoid Fracture)

  • 김명진;황정현;성주경;황성규;함인석;박연묵;김승래
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권11호
    • /
    • pp.1461-1468
    • /
    • 2000
  • Objective : The aim of this study is to evaluate clinical outcome of anterior screw fixation for type II odontoid fractures for the prliematim of atlanatoaxial mobility. Methods : Between 1995 and 1999, we treated 15 cases of type II odontoid fractures by anterior screw fixation among 44 cases of odontoid fractures. Thece included 14 males and 1 female aged from 23 to 63 years, with a mean age of 39.7 years. The causes of trauma were traffic accident in 13 cases, slip down in 1 and fall down in 1. The fracture type was type II-P in 7 cases, type II-A in 3, type II-N in 2 and type II-A and P in 3. The fracture line was oblique downward and backward in 6 cases, oblique downward and forward in 3 and horizontally in 6. The range of follow up was 4 to 47 months(mean 26.5 months). Results : Adequate reduction and fixation were obtained in 12 cases. Three cases in which fracture type and line were type II-A and oblique downward forward were failed, so posterior transarticular screw fixation was performed. All except 3 failed cases had adequate cervical movement and stability. There were no operative mortality nor morbidity. Conclusion : Anterior screw fixation provides the best anatomical and functional results for type II odontoid fracture with intact transverse ligament when fracture line is horizontal or oblique downward and backward. But it is limited when fracture line is oblique downward and forward.

  • PDF