• 제목/요약/키워드: Screw Threads

검색결과 47건 처리시간 0.021초

임플란트의 표면조도가 골융합에 미치는 영향 (Bone-to-Implant Contact according to the Surface Roughness of the Implants)

  • 최귀현;허익;이만섭;권영혁
    • Journal of Periodontal and Implant Science
    • /
    • 제33권4호
    • /
    • pp.717-728
    • /
    • 2003
  • This study was performed to evaluate the difference of the bone-to-implant contact according to the surface roughness of the implants. Two beagles were used in the experiment. Extraction of the all premolars was performed in the mandible. In 3 months of healing, screw-shaped pure titanium machined surface implants (Implantium(R), Dentium Co. Korea), implants blasted with 45${\mu}m$ $TiO_2$ particles, (Implantium(R), Dentium Co. Korea) and implants blasted with 100${\mu}m$ $TiO_2$ particles (Implantium(R), Dentium Co. Korea) in diameter 3.4mm and length 6mm were installed in the edentulous mandible. Each dog was sacrificed at 4, 12 weeks after placement and then nondecalcified specimens were prepared for histologic analysis. The results of this study were as follows. 1. At 4 , 12 weeks after the surgery, bone-to-implant contact in the surface blasted with $TiO_2$ particles was higher than that in the pure titanium machined surface respectively. 2. Osseointegration in the surface blasted with 45${\mu}m$ $TiO_2$ particles was more increased than that in the surface blasted with 100${\mu}m$ $TiO_2$ particles. 3. Bone-to-implant contact was increased with time independent of surface roughness. 4. Bone formation was in the outfolded area more than inside the threads independent of surface roughness. From the above results, we were able t o find the most bone-to-implant contact in 45${\mu}m$ $TiO_2$ blasted implant.

임플란트 생체금속들과 골조직간의 생체적합도에 관한 연구 (BICOMPATIBILITY OF BICOMTALS IN RABBIT BONE)

  • 한종현;허성주;정종평;구영;류인철;최용창
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.557-565
    • /
    • 1997
  • Screw-shaped implants of commercially pure (c.p.) titanium, c.p. niobium, c.p. zirconium, and stainless steel(Sus 304) were inserted in the rabbit tibial bone over 12 weeks of follow-up. New developed torque gauge instrument was used to evaluate the implant holding power and a image analysis program coupled to a microscope was used for histomorphometry. The three best consecutive threads of each implant were measured. Quantitative analyses at 12 weeks revealed a partial bone contact to the four kinds investigated metals. There were no obvious adverse tissue reactions to any of the biomaterials. At 12 weeks the average removal torques for titanium, niobium and zirconium were better than that needed for Sus 304 screws, on the other hand high score of bony contact ratio of titanium and niobium were showed in comparison to those of zirconium and Sus 304. There was no significant differences in the amount of interfacial bone of zirconium and Sus 304 whereas there was significant difference in the torque forces of niobium and Sus 304. Three months after implant insertion, the average removal torque was 6.64 Ncm for the titanium, 6.57 Ncm for the niobium, 6.38 Ncm for the zirconium, and 4.25 Ncm for the Sus 304. On average bone contacts there were 51.24% in the titanium, 48.19% in the niobium, 31.79% in the zirconium, 23.54% in the Sus 304. Biocompatibility of the titanium, niobium and zirconium was acceptable level in comparison to the Sus 304.

  • PDF

Enhancement of bioactivity and osseointegration in Ti-6Al-4V orthodontic mini-screws coated with calcium phosphate on the TiO2 nanotube layer

  • Byeon, Seon-Mi;Kim, Hye-Ji;Lee, Min-Ho;Bae, Tae-Sung
    • 대한치과교정학회지
    • /
    • 제52권6호
    • /
    • pp.412-419
    • /
    • 2022
  • Objective: This study evaluated the effect of cyclic pre-calcification treatment on the improvement of bioactivity and osseointegration of Ti-6Al-4V mini-screws. Methods: The experimental groups were: an untreated group (UT), an anodized and heat-treated group (AH), and an anodized treatment followed by cyclic pre-calcification treatment group (ASPH). A bioactive material with calcium phosphate was coated on the mini-screws, and its effects on bioactivity and osseointegration were evaluated in in vitro and in vivo tests of following implantation in the rat tibia. Results: As a result of immersing the ASPH group in simulated body fluid for 2 days, protrusions appearing in the initial stage of hydroxyapatite precipitation were observed. On the 3rd day, the protrusions became denser, other protrusions overlapped and grew on it, and the calcium and phosphorus concentrations increased. The removal torque values increased significantly in the following order: UT group (2.08 ± 0.67 N·cm), AH group (4.10 ± 0.72 N·cm), and ASPH group (6.58 ± 0.66 N·cm) with the ASPH group showing the highest value (p < 0.05). In the ASPH group, new bone was observed that was connected to the threads, and it was confirmed that a bony bridge connected to the adjacent bone was formed. Conclusions: In conclusion, it was found that the surface treatment method used in the ASPH group improved the bioactivity and osseointegration of Ti-6Al-4V orthodontic mini-screws.

THE EFFECT OF AUTOLOGOUS PLATELET-RICH PLASMA (PRP) ON BONE FORMATION AROUND DENTAL IMPLANT IN THE RABBIT: A HISTOMOR-PHOMETRIC AND REMOVAL TORQUE STUDY

  • Yi Yang-Jin;Yang Jae-Ho;Lee Sun-Hyung;Kim Yung-Soo;Kwon Sang-Ho
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.659-681
    • /
    • 2001
  • Platelet-rich plasma(PRP) has been known to increase the rate and degree of bone formation by virtue of growth factors in concentrated platelets. Although its great healing effect on bone defect or pre-implantation site preparation in conjunction with bone substitute has been reported, the effect associated with implant is unknown. The purpose of this study was to investigate the effect of PRP on rapid osseointegration of endosseous dental implants in the rabbit tibiae. Twenty two adult female New Zealand white rabbits, weighing approximately 2.7-3.3kg, were used for this study. Twelve of the 22 animals were used for histomorphometric analysis and ten of the 22 were for removal torque test. Each animal received two implants in each tibia (two treated with PRP and two as control) and was given fluorochrome intramuscularly. For histomorphometric analysis, rabbits were divided into four groups according to the healing period. At 1 week, 2 weeks, 4 weeks and 8 weeks postoperatively, each three animals were sacrificed serially and the amount and rate of bone formation around dental implant were examined on the undecalcified sections under fluorescent microscope, polarized microscope and light microscope connected to a personal computer equipped with image analysis system. For removal torque test, rabbits were divided into two groups and removal torque tests were performed at 4 weeks, 10 weeks after implant placement. In total, 88 screw shaped, commercially pure titanium implants (Neoplant, Neobiotech, Seoul, Korea) were used in this study. Labeling pattern reflected differences of two groups in bone formation rate at each period. Histomorphometrically, PRP group showed significantly higher bone volume within threads compared to control group at 2 weeks ($70.30{\pm}4.96%$ vs. $50.68{\pm}6.33%$; P < .01) and 4 weeks ($82.59{\pm}5.94%$ vs. $72.94{\pm}4.57%$; P < .05 ). PRP group at 1, 2 and 4 weeks revealed similar degree of bone volume formation comparable to control group at 2, 4 and 8 weeks, respectively. On the other hand, while PRP group showed higher bone-implant contact ($47.37{\pm}8.09%$) than control group ($33.16{\pm}13.47%$) at 2 weeks, there were no significant differences between PRP group and control group for any experimental period. Removal torque values also showed no significant differences between PRP group and control group at any experimental period (P > .05). These findings imply that PRP could induce rapid, more bone formation around implant during early healing period and get faster secondary stability for reducing healing period, though it has not induced bone maturation enough to resist functional loading.

  • PDF

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구 (Study of the re-osseointegration of implant fixture after mechanical unscrewing)

  • 장지훈;조진현;이청희
    • 대한치과보철학회지
    • /
    • 제48권3호
    • /
    • pp.209-214
    • /
    • 2010
  • 연구 목적: 본 연구의 목적은 골 유착된 임플란트에 인위적 비틀림을 가한 후 골 유착이 다시 일어나는지, 혹은 일어나지 않는지, 일어난다면 이전의 골유착보다 강화되는지, 약화되는지에 대해 알아보기 위함이다. 연구 재료 및 방법:상업적으로 순수한 티타늄 (commercial pure titanium 99%)으로 직경 3.75 mm, 길이 4 mm의 표면처리 없는 실험용 임플란트를 제작하였다. 3.0 kg이상의 뉴질랜드산 흰색 암컷 토끼 7마리의 좌우 경골에 제작한 임플란트를 2개씩 식립 후, 6주의 골유착 유도 기간 부여 후 비틀림 제거력을 측정한 경우를 I군으로, 다시 임플란트 고정체를 재위치시키고 봉합하여 4주간의 치유기간을 더 두고 측정한 경우를 II군으로 분류하였다. 광학현미경을 이용한 조직 형태학적 분석을 위하여, 1차 비틀림 제거력 측정 직후 1마리의 토끼를 희생시키고, 2차 비틀림 제거력 측정 직후 2마리의 토끼를 희생시켜 각각 4개, 7개의 시편을 제작하여, 광학현미경 (${\times}20$) 분석에서 골-임플란트 접촉 (Bone-Implant contact, BIC, %)비율과 치밀골 부위에 위치하는 임플란트의 나사산 수를 측정하여 CBa (Bone area in the cortical passage)비율을 측정하였다. 비틀림 제거력과 BIC및 CBa비율에서의 I군과 II군의 통계적 유의성 ($\alpha$=.05)을 평가하였다. 결과: 비틀림 제거력 측정에서 I군은 $10.8{\pm}3.6$ NCm로 측정되었으며, II군은 $20.2{\pm}9.7$ NCm로 측정되었으며, I군보다II군의 비틀림 제거력이 평균 98.1% 증가되었다 (P<.05). 조직 형태학적 분석에서 BIC와 CBa 비율은 I군과 II군 사이에 통계적 유의성을 나타내지 않았고 (P>.05), RT/BIC와 RT/CBa 값은 I군과 II군 사이에 통계적 유의성을 나타냈다 (P<.05). 결론: 임플란트 고정체에 의원성 비틀림 동요가 발생한 경우에 초기 골유착을 얻기 위해 필요로 했던 치유기간보다 짧은 기간 내에 이전보다 견고한 골유착을 얻을 수 있을 것으로 생각된다.

폴리프로필렌사(絲)칩과 배향사(配向絲)를 결체(結締)한 톱밥보드의 물리적(物理的) 및 기계적(機械的) 성질(性質)에 관(關)한 연구(硏究) (A Study on Physical and Mechanical Properties of Sawdustboards combined with Polypropylene Chip and Oriented Thread)

  • 서진석;이필우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제16권2호
    • /
    • pp.1-41
    • /
    • 1988
  • 톱밥을 보드에 활용(活用)하기 위한 방안(方案)으로서, 톱밥자체의 약(弱)한 결집력(結集力)과 치수불량성(不良性)을 개선(改善)하기 위하여 비(非) 목질계(木質系) 재료(材料)인 폴리프로필렌 사(絲)칩과 배향사(配向絲)를 혼합(混合) 결체(結締)함에 다른 보드의 기초성질(基礎性質)로서 물리적(物理的) 기계적(機械的) 성질(性質)을 고찰(考察)하였는 바, 현재(現在) 제재용(製材用)으로 많이 이용(利用)되고 있는 나왕재(羅王材)(white meranti)의 톱밥에 개질재료(改質材料)로서 비(非) 목질(木質) 계(系) 플라스틱 물질(物質)인 폴리프로필렌 사(絲)를 칩상(狀) 또는 배향사(配向絲)의 형태(形態)로 조제(調製)하여 일반(一般) 성형법(成型法)을 적용(適用)함으로써 톱밥과 결체(結締) 구성(構成)한 톱밥보드를 제조(製造)하였다. 12 및 15%로 하여 구성(構成)하였다. 배향사(配向絲)는 보드폭방향(幅方向)으로 0.5, 1.0 및 1.5cm의 일정(一定)한 간격(間隔)으로 배열(配列)하였다. 위의 조건(條件)에 의(依)해 단(單) 2 3층(層)으로 각기(各己) 구분(區分)제조된 사(絲)칩 또는 배향사(配向絲) 구성(構成) 톱밥보드의 물리적(物理的) 및 기계적(機械的) 성질(性質)을 구명(究明)하였는 바, 그 주요(主要)한 결론(結論)을 요약(要約)하면 다음과 같다. 1. 사(絲)칩 혼합(混合) 단층구성(單層構成)보드의 두께 팽창율(膨脹率)은 톱잡대조(對照)보드의 팽창율보다 모두 낮았다. 사(絲)칩 함량(含量)을 증가(增加) 시킴에 따라서 두께 팽창율은 점차(漸次) 감소(減少)하는 경향이 뚜렷하였다. 한편, 2층구성(層構成)보드는 단층(單層) 구성(構成)보드보다 높은 팽창율을 나타냈으나 대부분이 톱밥대조(對照)보드 보다 팽창율이 낮았다. 3층(層)으로 사(絲)칩구성(構成)한 보드는 톱밥대조(對照)보드보다도 모두 낮은 두께 팽창율을 나타냈다. 2. 사(絲)칩 배향사(配向絲) 구성(構成)보드의 두께 팽창율은 0.5cm 배향간격에서 사(絲)칩함량(含量) 12%와 15%의 길이 1.0cm와 1.5cm로 구성함으로써 단층(單層) 및 3층구성(層構成)보드의 최저치(最低値)보다 더 낮았다. 3. 단층구성(單層構成)보드의 휨강도는 비중(比重) 0.51 구성(構成)보드의 경우 사(絲)칩함량(含量) 3%에서 톱밥대조)對照)보드보다 높은 강도를 나타냈으나, KS F 3104 의 파티클보드 100타입 기준(基準) 값인 80 kgf/$cm^2$에 훨씬 못 미쳤다. 그러나 비중(比重) 0.63 구성(構成)보드에서 함량(含量) 6%의 길이 1.5cm 사(絲)칩 구성과 함량(含量)3% 의 모든 사(絲)칩 길이로 구성한 보드, 그리고 비중(比重) 0.72의 모든 사(絲)칩 구성보드는 KS F 기준값을 훨씬 상회(上廻) 하였다. 2층구성(層構成)보드의 휨강도는 톱밥대조(對照)보드보다도 사(絲)칩구성의 경우 모두 낮았으며 단층구성(單層構成)보드의 휨강도보다도 낮은 값을 나타냈다. 3층구성(層構成)보드의 휨강도는 사(絲)칩 함량(含量) 9% 이하(以下)의 길이 1.5cm 구성보드는 모두 톱밥대조(對照)보드보다 높은 값을 나타냈으며 KSF 기준값을 훨씬 상회(上廻) 하였다. 4. 배향사구성(配向絲構成) 톱밥보드의 경우(境遇), 배향간격(配向間隔)이 좁은 0.5cm에서 가장 높은 휨강도를 나타냈으며, 배향간격이 보다 넓은 1.0cm 와 1.5cm 구성(構成)에서는 휨 강도가 0.5cm 간격 보다 낮았다. 그러나 배향사구성(配向絲構成) 톱밥보드는 모두 톱밥대조(對照)보드 보다 높은 휨강도를 나타냈다. 5. 사(絲칩) 배향사(配向絲) 구성 보드의 휨강도는 거의 대부분(大部分)의 구성보드에서 톱밥대조(對照)보드보다 높은 값을 나타냈으며 KSF 기준값을 훨씬 상회(上廻) 하였다. 특(特)히 배향간격이 좁고, 길이가 긴 사(絲)칩으로 구성한 보드의 휨강도가 높은 값을 나타냈다. 그리고 사(絲)칩을 배향사(配向絲)와 혼합(混合) 구성(構成)할 때 배향사의 간격이 넓어짐에 따라 톱밥과 배향사(配向絲)만으로 구성한 보드보다도 휨 강도가 높아지는 현상(現象)이 나타났다. 6. 단층(單層), 2층(層) 및 3층(層) 구성(構成) 보드의 탄성계수는 대부분(大部分) 톱밥대조(對照)보드 보다 낮은 값을 나타냈다. 그러나 배향사(配向絲) 구성(構成) 톱밥보드에 있어서는, 배향 간격이 0.5, 1.0, 1.5crn로 됨에 따라서 톱밥대조(對照)보드보다도 각각(各各) 20%, 18%, 10% 탄성계수가 증가(增加)되었다. 7. 사(絲)칩 배향사(配向絲) 구성(構成) 보드의 탄성계수(彈性係數)는 배향간격 0.5crn, 1.0cm 및 1.5crn에서 거의 모두 톱밥대조(對照)보드보드보다도 훨씬 높은 값을 나타냈다. 그리고 함량(含量)9% 이하(以下)에서 사(絲)칩길이를 0.5cm이상(以上)으로 구성하였을 때 배향사(配向絲)만을 구성한 톱밥보드보다도 탄성계수가 높아지는 현상(現象)이 나타났는데, 배향(配向)간격이 좁은 경우 사(絲)칩결체(結締)에 의(依)한 탄성계수(彈性係數) 증가효과(增加效果)가 컸다. 8. 사(絲)칩 혼합(混合) 단층구성(單層構成) 보드의 박리저항(剝離抵抗)은 톱밥대조(對照)보드 보다 모두 낮았다. 그러나 비중(比重) 0.63의 사(絲)칩 구성보드는 KS F 3104의 100타입 기준 값인 1.5kgf/$cm^2$를 모두 상회(上廻) 하였고, 비중(比重) 0.72의 사(絲)칩 구성보드는 200타입의 기준값 3kgf/$cm^2$를 상회(上廻)하는 박리저항(剝離抵抗)을 나타냈다. 2층(層), 3층(層) 및 배향구성(配向構成)도 거의 모두 200타입의 기준값 3kgf/$cm^2$를 상회(上廻) 하였다. 9. 단층구성(單層構成)보드의 나사못유지력(維持力)은 사(絲)칩을 혼합 구성한 경우, 대체(大體)로 톱밥대조(對照)보드보다도 낮은 값을 나타냈다. 그러나, 2층(層) 및 3층구성(層構成)보드에서는 사(絲)칩 구성(構成)에 따른 감소경향(減少傾向)이 나타나지 않고 대체로 고른 나사못 유지력을 나타냈다. 또한, 사(絲)칩 배향사(配向絲) 구성(構成)보드에서는 사(絲)칩함량(含量) 9% 이하(以下)에서 거의 모두 톱밥대조(對照)보드 보다도 높은 나사못 유지력을 나타냈다.

  • PDF