• 제목/요약/키워드: Screening ultrasound

검색결과 80건 처리시간 0.024초

Automated Breast Ultrasound Screening for Dense Breasts

  • Sung Hun Kim;Hak Hee Kim;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제21권1호
    • /
    • pp.15-24
    • /
    • 2020
  • Mammography is the primary screening method for breast cancers. However, the sensitivity of mammographic screening is lower for dense breasts, which are an independent risk factor for breast cancers. Automated breast ultrasound (ABUS) is used as an adjunct to mammography for screening breast cancers in asymptomatic women with dense breasts. It is an effective screening modality with diagnostic accuracy comparable to that of handheld ultrasound (HHUS). Radiologists should be familiar with the unique display mode, imaging features, and artifacts in ABUS, which differ from those in HHUS. The purpose of this study was to provide a comprehensive review of the clinical significance of dense breasts and ABUS screening, describe the unique features of ABUS, and introduce the method of use and interpretation of ABUS.

산전 검진의 최신 지견 (The recent trend of prenatal screening)

  • 황도영
    • Journal of Genetic Medicine
    • /
    • 제5권1호
    • /
    • pp.7-14
    • /
    • 2008
  • Twenty years have passed since a prenatal screening for Down syndrome and neural tube defect was applied to obstetric field. The Quad test (AFP, hCG, uE3, Inhibin-A) of the second trimester and the combination test (PAPP-A, hCG, NT) of the first trimester became popular now. The recent trend of prenatal screening is to combine these two screening tests together in order to increase a detection rate of Down syndrome. Three types of screening methods are introduced as follows; integrated test, sequential test and contingent test. In addition to combination of each test, an incorporation of characteristic ultrasound findings of Down syndrome is suggested for its risk calculation. The absence of fetal nasal bone would be a very useful marker especially in the first trimester screening test. According to a change of way calculating risk of Down syndrome, obstetrician's role will be more increased not by passive participation, but by active participation using ultrasound in risk calculation.

  • PDF

The Results of a Breast Cancer Screening Camp at a District Level in Rural India

  • Reddy, Neha;Ninan, Tilu;Tabar, Laszlo;Bevers, Therese
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권12호
    • /
    • pp.6067-6072
    • /
    • 2012
  • Background: Breast cancer in developing countries is on the rise. There are currently no guidelines to screen women at risk in India. Since mammography in the western world is a well-accepted screening tool to prevent late presentation of breast cancer and improve mortality, it is intuitive to adopt mammography as a screening tool of choice. However, it is expensive and fraught with logistical issues in developing countries like India. Materials and Methods: Our breast cancer screening camp was done at a local district hospital in India after approval from the director and administrators. After initial training of local health care workers, a one-day camp was held. Clinical breast examination, mammograms, as well as diagnostic evaluation with ultrasound and fine needle aspiration biopsy were utilized. Results: Out of total 68 women screened only 2 women with previous history of breast cancer were diagnosed with breast cancer recurrence. None of the women in other groups were diagnosed with breast cancer despite suspicious lesions either on clinical exam, mammogram or ultrasound. Most suspicious lesions were fibroadenomas. The average cost of screening women who underwent mammography, ultrasound and fine needle aspiration was $30 dollars, whereas it was $16 in women who had simple clinical breast examination. Conclusions: Local camps act as catalysts for women to seek medical attention or discuss with local health care workers concerns of discovering new lumps or developing breast symptoms. Our camp did diagnose recurrence of breast cancer in two previously treated breast cancer patients, who were promptly referred to a regional cancer hospital. Further studies are needed in countries like India to identify the best screening tool to decrease the presentation of breast cancer in advanced stages and to reduce mortality.

Comparison of Mammography in Combination with Breast Ultrasonography Versus Mammography Alone for Breast Cancer Screening in Asymptomatic Women

  • Boonlikit, Sarawan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7731-7736
    • /
    • 2013
  • Aim: To compare the agreement of screening breast mammography plus ultrasound and reviewed mammography alone in asymptomatic women. Materials and Methods: All breast imaging data were obtained for women who presented for routine medical checkup at National Cancer Institute (NCI), Thailand from January 2010 to June 2013. A radiologist performed masked interpretations of selected mammographic images retrieved from the computer imaging database. Previous mammography, ultrasound reports and clinical data were blinded before film re-interpretation. Kappa values were calculated to assess the agreement between BIRADS assessment category and BIRADS classification of density obtained from the mammography with ultrasound in imaging database and reviewed mammography alone. Results: Regarding BIRADS assessment category, concordance between the two interpretations were good. Observed agreement was 96.1%. There was moderate agreement in which the Kappa value was 0.58% (95%CI; 0.45, 0.87). The agreement of BI-RADS classification of density was substantial, with a Kappa value of 0.60 (95%CI; 0.54, 0.66). Different results were obtained when a subgroup of patients aged ${\geq}60$ years were analyzed. In women in this group, observed agreement was 97.6%. There was also substantial agreement in which the Kappa value was 0.74% (95%CI; 0.49, 0.98). Conclusions: The present study revealed that concordance between mammography plus ultrasound and reviewed mammography alone in asymptomatic women is good. However, there is just moderate agreement which can be enhanced if age-targeted breast imaging is performed. Substantial agreement can be achieved in women aged ${\geq}60$. Adjunctive breast ultrasound is less important in women in this group.

Digital Breast Tomosynthesis Plus Ultrasound Versus Digital Mammography Plus Ultrasound for Screening Breast Cancer in Women With Dense Breasts

  • Su Min Ha;Ann Yi;Dahae Yim;Myoung-jin Jang;Bo Ra Kwon;Sung Ui Shin;Eun Jae Lee;Soo Hyun Lee;Woo Kyung Moon;Jung Min Chang
    • Korean Journal of Radiology
    • /
    • 제24권4호
    • /
    • pp.274-283
    • /
    • 2023
  • Objective: To compare the outcomes of digital breast tomosynthesis (DBT) screening combined with ultrasound (US) with those of digital mammography (DM) combined with US in women with dense breasts. Materials and Methods: A retrospective database search identified consecutive asymptomatic women with dense breasts who underwent breast cancer screening with DBT or DM and whole-breast US simultaneously between June 2016 and July 2019. Women who underwent DBT + US (DBT cohort) and DM + US (DM cohort) were matched using 1:2 ratio according to mammographic density, age, menopausal status, hormone replacement therapy, and a family history of breast cancer. The cancer detection rate (CDR) per 1000 screening examinations, abnormal interpretation rate (AIR), sensitivity, and specificity were compared. Results: A total of 863 women in the DBT cohort were matched with 1726 women in the DM cohort (median age, 53 years; interquartile range, 40-78 years) and 26 breast cancers (9 in the DBT cohort and 17 in the DM cohort) were identified. The DBT and DM cohorts showed comparable CDR (10.4 [9 of 863; 95% confidence interval {CI}: 4.8-19.7] vs. 9.8 [17 of 1726; 95% CI: 5.7-15.7] per 1000 examinations, respectively; P = 0.889). DBT cohort showed a higher AIR than the DM cohort (31.6% [273 of 863; 95% CI: 28.5%-34.9%] vs. 22.4% [387 of 1726; 95% CI: 20.5%-24.5%]; P < 0.001). The sensitivity for both cohorts was 100%. In women with negative findings on DBT or DM, supplemental US yielded similar CDRs in both DBT and DM cohorts (4.0 vs. 3.3 per 1000 examinations, respectively; P = 0.803) and higher AIR in the DBT cohort (24.8% [188 of 758; 95% CI: 21.8%-28.0%] vs. 16.9% [257 of 1516; 95% CI: 15.1%-18.9%; P < 0.001). Conclusion: DBT screening combined with US showed comparable CDR but lower specificity than DM screening combined with US in women with dense breasts.

Screening in the Era of Economic Crisis: Misperceptions and Misuse from a Longitudinal Study on Greek Women Undergoing Benign Vacuum-assisted Breast Biopsy

  • Domeyer, Philip John;Sergentanis, Theodoros Nikolaos;Katsari, Vasiliki;Souliotis, Kyriakos;Mariolis, Anargiros;Zagouri, Flora;Zografos, George Constantine
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권9호
    • /
    • pp.5023-5029
    • /
    • 2013
  • Background: To evaluate knowledge about screening tests and tests without proven screening value in a Greek Breast Unit population undergoing benign vacuum-assisted breast biopsy (VABB). Materials and Methods: This study included 81 patients. Three knowledge-oriented items (recommended or not, screening frequency, age of onset) were assessed. Regarding screening tests two levels of knowledge were evaluated: i). crude knowledge (CK), i.e. knowledge that the test is recommended and ii). advanced knowledge (AK), i.e. correct response to all three knowledge-oriented items. Solely CK was evaluated for tests without proven screening value. Risk factors for lack of knowledge were assessed with multivariate logistic regression. A second questionnaire was administered 18 months after VABB to assess its impact on the performance of tests. Results: Concerning screening tests considerable lack of AK was noted (mammogram, 60.5%; Pap smear, 59.3%; fecal occult blood testing, 93.8%; sigmoidoscopy, 95.1%). Similarly lack of CK was documented regarding tests without proven screening value (breast self-examination, 92.6%; breast MRI, 60.5%; abdominal ultrasound, 71.6%; barium meal, 48.1%; urine analysis, 90.1%; chest X-Ray, 69.1%; electrocardiogram, 74.1%; cardiac ultrasound, 75.3%). Risk factors for lack of AK were: place of residence (mammogram), age (Pap smear), personal income (sigmoidoscopy); risk factors for lack of CK included number of offspring (breast MRI, chest X-Ray), BMI (abdominal ultrasound), marital status (urine analysis), current smoking status (electrocardiogram). VABB's only effect was improvement in mammogram rates. Conclusions: A considerable lack of knowledge concerning screening tests and misperceptions regarding those without proven value was documented.

The Prenatal and Postnatal Incidence of Congenital Anomalies of the Kidneys and Urinary Tract (CAKUT) Detected by Ultrasound

  • Choi, Hyun Ah;Lee, Dong Jun;Shin, Son Moon;Lee, Yeon Kyung;Ko, Sun Young;Park, Sung Won
    • Childhood Kidney Diseases
    • /
    • 제20권1호
    • /
    • pp.29-32
    • /
    • 2016
  • Purpose: Congenital anomalies of the kidneys and urinary tract (CAKUT) are the most common anomalies identified in newborns. This study aims to demonstrate the prevalence of CAKUT including hydronephrosis diagnosed by antenatal and postnatal ultrasound over a five-year period. Methods: The records of births between May $1^{st}$, 2009 and April $30^{th}$, 2014 at our hospital were collected. The number of infants who underwent renal ultrasound after birth for the detection of CAKUT was counted. The incidence of each type of CAKUT such as hydronephrosis, size abnormality, horseshoe kidney, and Multicystic dysplastic kidney (MCDK) was retrospectively evaluated for antenatal screening and postnatal follow-up examination. Results: During the study period, 33,276 infants were born and 521 neonates underwent postnatal renal ultrasound. 183 cases of CAKUT were detected prenatally and 140 postnatally using ultrasonographic examinations at the following time: (i) 3-7 days postnatally in 123 newborns (87.9%), (ii) during 1-3 months in 11 newborns (7.9%), and (iii) later than 3 months in 6 newborns (4.3%). Among diagnosed CAKUT, hydronephrosis was the most common anomaly with 113 newborns diagnosed prenatally and 46 postnatally. Duplex kidney was the second most common anomaly followed by horseshoe kidney, simple cysts in the kidney and so on. Conclusion: The detection of CAKUT is an important part of the prenatal ultrasound. This study analyzed the prevalence of CAKUT detected on prenatal screening and compared the results to those detected postnatally. Prenatal ultrasound screening fulfills the needs of postnatal examinations and therefore, both antenatal and postnatal sonographic investigations are of vital importance for diagnosis of renal and urinary tract anomalies.

The Use of Transabdominal Ultrasound in Inflammatory Bowel Disease

  • Jiro Hata;Hiroshi Imamura
    • Korean Journal of Radiology
    • /
    • 제23권3호
    • /
    • pp.308-321
    • /
    • 2022
  • Transabdominal ultrasound (TAUS) is useful in all aspects of lesion screening, monitoring activity, or treating/diagnosing any related complications of inflammatory bowel disease. Its ability to screen or diagnose complications is almost the same as that of other methods, such as CT or MRI. Moreover, its noninvasiveness makes it a first-line examination method. A TAUS image depicting ulcerative colitis will show large intestinal wall thickening that is continuous from the rectum, which is mainly due to mucosal layer thickening, while for Crohn's disease, a TAUS image is characterized by a diversity in the areas affected, distribution, and layer structure. Indicators of activity monitoring include wall thickness, wall structure, and vascular tests that use Doppler ultrasound or contrast agents. While all of these have been reported to be useful, at this time, no single parameter has been established as superior to others; therefore, a comprehensive evaluation of these parameters is justified. In addition, evaluating the elasticity of lesions using elastography is particularly useful for distinguishing between fibrous and inflammatory stenoses. However, the lack of objectivity is the biggest drawback of using ultrasound. Standardizing and popularizing the ultrasound process will be necessary, including scanning methods, equipment settings, and image analysis.

Comparative Efficacy of Four Imaging Instruments for Breast Cancer Screening

  • Mehnati, Parinaz;Tirtash, Maede Jafari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권15호
    • /
    • pp.6177-6186
    • /
    • 2015
  • Sensitivity and specificity are the two most important indicators in selection of medical imaging devices for cancer screening. Breast images taken by conventional or digital mammography, ultrasound, MRI and optical mammography were collected from 2,143,852 patients. They were then studied and compared for sensitivity and specificity results. Optical mammography had the highest sensitivity (p<0.001 and p<0.006) except with MRI. Digital mammography had the highest specificity for breast cancer imaging. A comparison of specificity between digital mammography and optical mammography was significant (p<0.021). If two or more breast diagnostic imaging tests are requested the overall sensitivity and specificity will increase. In this literature review study patients at high-risk of breast cancer were studied beside normal or sensitive women. The image modality performance of each breast test was compared for each.