• Title/Summary/Keyword: Screening System

Search Result 1,401, Processing Time 0.03 seconds

Screening of New Antibiotics Inhibiting Bacterial Peptide Deformylase (PDF) (세균의 Peptide Deformylase(PDF)를 억제하는 새로운 항균물질의 스크리닝)

  • 곽진환;김현주;설민정;서병선;이종국;최수영
    • YAKHAK HOEJI
    • /
    • v.47 no.3
    • /
    • pp.184-189
    • /
    • 2003
  • Peptide deformylase (PDF) is essential and unique to bacteria, thus making it an attractive target for the discovery of novel antibacterial drugs. PDF deformylates the N-formylmethionine of newly synthesized polypeptides in prokaryotes. In this study, a pdf gene from Staphylococcus aureus 6538p was cloned in pET-14b vector and PDF protein was over-produced in Escherichia coli BL21 (DE3). NH$_2$-terminal His-tagged PDF protein was purified by nickel-nitrilotriacetic acid (Ni-NTA) metal-affinity chromatography. Enzymatic activity of purified 6xHis-tagged PDF was tested on the substrate (formyl-Methionine-Alanine-Serine) by formate dehydrogenase-coupled spectrometric assay of peptide deformylase. For the discovery of new PDF inhibitors from chemical libraries and culture broths of soil bacteria, a target-oriented screening system using a 96-well plate was developed. About 3,000 commercial chemical libraries were tested in this screening system, and 2 chemicals (0.07%) among them showed an inhibitory activity against PDF enzyme. This result showed that a new screening system can be used for the discovery of new PDF inhibitors.

Fabrication of a Parallel Polymer Cantilever to Measure the Contractile Force of Drug-treated Cardiac Cells (약물처리된 심장세포의 세포 수축력 측정을 위한 병렬 폴리머 캔틸레버 제작)

  • Kim, Dong-Su;Lee, Dong-Weon
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.100-104
    • /
    • 2020
  • Thus far, several in vivo biosensing platforms have been proposed to measure the mechanical contractility of cultured cardiomyocytes. However, the low sensitivity and screening rate of the developed sensors severely limit their practical applications. In addition, intensive research and development in cardiovascular disease demand a high-throughput drug-screening platform based on biomimetic engineering. To overcome the drawbacks of the current state-of-the-art methods, we propose a high-throughput drug-screening platform based on 16 functional high-sensitivity well plates. The proposed system simulates the physiological accuracy of the heart function in an in vitro environment. We fabricated 64 cantilevers using highly flexible and optically transparent silicone rubber and placed in 16 independent wells. Nanogrooves were imprinted on the surface of the cantilever to promote cell alignment and maturation. The adverse effects of the cardiovascular drugs on the cultured cardiomyocytes were systematically investigated. The 64 cantilevers demonstrated a highly reliable and reproducible mechanical contractility of the drug-treated cardiomyocytes. Real-time high-throughput screening and simultaneous evaluation of the cardiomyocyte mechanical contractility under multiple drugs verified that the proposed system could be used as an efficient drugtoxicity test platform.

Effectiveness of a Community-based Program Using Tailored Stage-matched Messages to Promote Screening for Stomach Cancer (지역사회 여성 주민을 대상으로 한 대상중심형 위암 조기검진 교육 프로그램의 개발 및 효과평가)

  • Kim, Young-Bok
    • Korean Journal of Health Education and Promotion
    • /
    • v.22 no.2
    • /
    • pp.97-110
    • /
    • 2005
  • Objectives: Recent studies have shown that tailored messages for cancer screening to the beliefs and stage of cancer screening behavior of individual women increases the take-up probability. Many studies on cancer screening have used the Transtheoretical Model (TTM) to identify variables associated with cancer screening behavior. This study was carried out to identify the cognitive-behavioral factors associated with stomach cancer screening among women aged 40 years and over, and to develop and evaluate a tailored educational program for stomach cancer screening by stages of change. Methods: Building on the TTM constructs, we conducted a quasi-experimental study(N=283) to test the effectiveness of a tailored educational program for endoscopic stomach cancer screening. We carried out pre and post tests in the experimental group(N=162) and the control group(N=121), and the experimental group was subdivided into an on-line group(N=81) and an off-line group(N=81) by educational methodology using e-mail and the postal service. We used the chi-square test, trend test, and paired t-test to test the effectiveness of the program for stomach cancer using a tailored stage-matched messages. Results: To examine the effectiveness of the program for stomach cancer screening by the tailored stage-matched messages, the stage-matched materials were offered to the experimental group(N=162) four times for 4 weeks. The stage-matched materials consisted of the four types for stomach cancer. The tailored message was effective in changing the cognitive-behavioral factors, such as experience process, behavior process, con opinion for stomach cancer, self-efficacy, and the behavioral stages for stomach cancer screening. The stomach cancer screening adherence was higher for the stage-matched materials using postal mail than for those using e-mail. Conclusion: To improve the stomach cancer screening rate, the use of tailored messages for stomach cancer screening will be generated using an expert system. Therefore the implementation of tailored educational program will be supported a partnership between public and private health organizations and increasing awareness of the necessity of community-based interventions.

A Study of Contingency Screening Method Considering Voltage Security (전압안전도를 고려한 상정사고 스크린닝에 관한 연구)

  • 송길영;김영한;최상규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.2
    • /
    • pp.133-141
    • /
    • 1990
  • In the operation of an electric power system, the voltage security of the system has acquired more significant importance after the occurrence of large system black-outs caused by voltage collapse several times. This paper describes a fast contingency screening method concerning voltage security. The method defines a voltage-sensitive buses where significant voltage changes would occur as a result of the contingency to reduce the number of bus voltages to be solved for continngency screening. This method is based on the observation that it is not necessary to solve the entire network in most contingency cases because boltage changes actually occur around the contingency. The P-Q decoupled linearized model and the fast error correction method are also adopted in the method to define voltage-sensitive buses and to calculate voltage magnitude on the selected voltage-sensitive buses fastly and reliably. The method suggested in this papaer has been tested in IEEE 30-bus model system and KEPCO 130-bus actual system and its effectiveness for practical use has also been confirmed.

  • PDF

A Study on the Health Screening Solution by Using Electronic Medical Record (전자의무기록을 활용한 건강검진 솔루션에 관한 연구)

  • Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.7
    • /
    • pp.825-830
    • /
    • 2015
  • The Electronic Medical Record(: EMR) is to store medical data not in the form of document, but in the data storage. Such EMR can not only solve various problems of document use such as storage/arrangement of and securing space for document, but also make it possible to provide customized-treatment based on large quantity of customer data, so that hospitals can reduce the management cost and also improve the work efficiency. Customers also can receive the great quality of medical service. Owing to such strengths, the EMR has been rapidly introduced and applied to many hospitals and clinics since 1990s. In case of the current health screening system, however, paper forms used for health screening is also stored, on top of EMR. There would be various reasons why it is stored in the form of document. While the EMR used in hospitals is comprised of a unit program performing medical record, the health screening system is comprised of a unit program performing logics related to health screening. For this reason, it might be unavoidable for the health screening system to store document forms. If the EMR function is applied to the health screening system, it is expected to be able to operate more efficient health screening solution.

Design and Implementation of Service based Virtual Screening System in Grids (그리드에서 서비스 기반 가상 탐색 시스템 설계 및 구현)

  • Lee, Hwa-Min;Chin, Sung-Ho;Lee, Jong-Hyuk;Lee, Dae-Won;Park, Seong-Bin;Yu, Heon-Chang
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.6
    • /
    • pp.237-247
    • /
    • 2008
  • A virtual screening is the process of reducing an unmanageable number of compounds to a limited number of compounds for the target of interest by means of computational techniques such as molecular docking. And it is one of a large-scale scientific application that requires large computing power and data storage capability. Previous applications or softwares for molecular docking such as AutoDock, FlexX, Glide, DOCK, LigandFit, ViSION were developed to be run on a supercomputer, a workstation, or a cluster-computer. However the virtual screening using a supercomputer has a problem that a supercomputer is very expensive and the virtual screening using a workstation or a cluster-computer requires a long execution time. Thus we propose a service-based virtual screening system using Grid computing technology which supports a large data intensive operation. We constructed 3-dimensional chemical molecular database for virtual screening. And we designed a resource broker and a data broker for supporting efficient molecular docking service and proposed various services for virtual screening. We implemented service based virtual screening system with DOCK 5.0 and Globus 3.2 toolkit. Our system can reduce a timeline and cost of drug or new material design.

Cost analysis of hypertension screening program (고혈압 건강진단의 비용분석)

  • Park, Eun-Cheol;Yu, Seung-Hum
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.3 s.27
    • /
    • pp.380-388
    • /
    • 1989
  • To evaluate the costs of the hypertension screening program of the Korea Medical Insurance Corporation, the records of the screening examinations were used. The sample size was 49,983 of the 906,554 people insured by the Corporation and was obtained by two-stage stratification random sampling. The alternatives for efficiency of the screening program, which were divided into three categories : modification of the screening test package, application of other hypertension diagnostic criteria, and selective approach of tested groups by age, were evaluated according to the cost per patient detected. The results of this study were as follows In the hypertension screening system, the cost per patient detected was Won 30,883. The most nonsensitive test for hypertension detection was ophthalmoscopy, which was examined during the second stage of screening. If the ophthalmoscope examination was excluded, olny one person was not detected, which was 0.2% of detected persons, and the cost per patient detected decreased to Won 28,098. The most efficient modification of the screening test package was measurement of blood pressure through the first and second stages of screening. The cost per patient detected by this modification was Won 24,408. The application of other diagnostic critera, which were more restricted criteria, increased the cost per patient detected by 3.7%-6.7%. The cost per patient detected were Won 170,582 for persons less than 39 years old, Won 20,032 for persons 40 to 59 years old, and Won 8,675 for persons 60 years old and over. In conclusion, the best alternative suggested with respect to efficiency and practical application excluded the ophthalmoscope examination of second stage screening and restricted the target population to persons greater than 40 years old. The application of this alternative decreased 54.9% of the screening costs and the cost per patient detected was Won 15,222. This study was limited in that measurement of effectivenes was not of the ultimate goal of screening, which is decreasing morbidity and mortality, but was of disease detection as the short-term objective.

  • PDF

Trends in MEA-based Neuropharmacological Drug Screening (MEA 기반 신경제약 스크리닝 기술 개발 동향)

  • Y.H. Kim;S.D. Jung
    • Electronics and Telecommunications Trends
    • /
    • v.38 no.1
    • /
    • pp.46-54
    • /
    • 2023
  • The announcement of the US Environmental Protection Agency that it will stop conducting or funding experimental studies on mammals by 2035 should prioritize ongoing efforts to develop and use alternative toxicity screening methods to animal testing. Toxicity screening is likely to be further developed considering the combination of human-induced pluripotent-stem-cell-derived organ-on-a-chip and multielectrode array (MEA) technologies. We briefly review the current status of MEA technology and MEA-based neuropharmacological drug screening using various cellular model systems. Highlighting the coronavirus disease pandemic, we shortly comment on the importance of early prediction of toxicity by applying artificial intelligence to the development of rapid screening methods.