• Title/Summary/Keyword: Screening

Search Result 9,018, Processing Time 0.036 seconds

Research on Quality Components for Service Design of Health Screening : Focus on IT Services

  • Chung, Ju Youn;Jung, Dukyoo
    • Journal of Information Technology Applications and Management
    • /
    • v.27 no.4
    • /
    • pp.37-48
    • /
    • 2020
  • This research proposes how to enhance low customer satisfaction with health screening services caused by procedural complexity and limits of health screening. The purpose of this study is to identify sub-components of the service quality provided by general health examination centers. This is a qualitative analysis of in-depth interviews of providers and consumers of medical services. The data were primarily analyzed by affinity diagram, and the data were sorted and analyzed according to the criteria suggested by Donabedian's four components. Four types of quality factors and the health screening service quality components of 39 subordinate items were assessed. Components related to the use of IT facilities comprise a significant amount of the physical factors, and there are high demands for IT facilities among customers.

Determination of Optimal Mean Value and Screening Limit for a Production Process with Logistic Function (로지스틱 함수를 갖는 생산공정에 대한 최적공정평균 및 스크리닝 한계선의 결정)

  • Hong, Sung Hoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.29 no.3
    • /
    • pp.239-246
    • /
    • 2003
  • Individual items are produced continuously from an industrial process. Each item is checked to determine whether it satisfies a lower screening limit for the quality characteristic which is the weight of an expensive ingredient. If it does, it is sold at a regular price; if it does not, it is reprocessed or sold at a reduced price. The process mean may be adjusted to a higher value in order to reduce the proportion of the nonconforming items. Using a higher process mean, however, may result in a higher production cost. In this paper, the optimal process mean and lower screening limit are determined in situations where the probability that an item functions well is given by a logistic function of the quality characteristic. Profit models are constructed which involve four price/cost components; selling prices, cost from an accepted nonconforming item, and reprocessing and inspection costs. Methods of finding the optimal process mean and lower screening limit are presented and numerical examples are given.

A Study on the Determination of the Screening Factors for the Tunnel and the Overbridge of the Electric Railway (전기철도 터널 및 고가 구조물의 차폐계수 산정에 대한 연구)

  • Choi, Kyung;Lee, Hyang-Beom;Kim, Hyeong-Seok;Kim, Hak-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1249-1256
    • /
    • 2018
  • For the screening factor of the tunnel and overbridge structure in the electrified railway, the ITU-T regulation denotes only a theoretical estimation method, and the actual numeric values are notified differently by the official announcement of each nations. In this study, the factors which can affect the screening factor are investigated and analysed by FEM and a suitable calculation method based on multi-conductor line theory for the current pre-estimation formula for the induction noise voltage in the national notice is presented. The case studies are performed using the real data of the tunnel and the overbridge of the electrified railway, and a satisfactory formula for the determining of screening factor is derived.

Design of Screening Procedures Using a Surrogate Variable with Specified Producer's and Consumer's Risks (대용특성을 활용한 규준형 스크리닝 절차의 설계)

  • Hong, Sung-Hoon;Jung, Min-Young
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.4
    • /
    • pp.23-30
    • /
    • 2009
  • When the measurement method for a performance variable is destructive or expensive, it is profitable to replace the performance variable with a highly correlated surrogate variable. In this paper we propose screening procedures using a surrogate variable with specified producer's and consumer's risks. Blending the basic concepts of acceptance sampling plans and screening procedures, the proposed model can be used effectively by quality professionals. Two models are considered: the normal model with dichotomous performance and continuous surrogate variables, and the bivariate normal model with continuous performance and surrogate variables. It is assumed the surrogate variable given the performance variable is normally distributed in the normal model, and performance and surrogate variables are jointly normally distributed in the bivariate normal model. For the two models, producer's and consumer's risks are derived, and methods of finding the optimal screening procedures are presented. Numerical examples are also given.

Fast Screening of Harmful Disinfectants in Household Products via Low-Temperature Plasma Ionization-Mass Spectrometry

  • Lee, Hyoung Jun;Kweon, Gi Ryang;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.44-47
    • /
    • 2017
  • Isothiazolinone derivatives are widely used in consumer products as disinfectants or preservatives, but there are growing concerns about their impact on human health. Therefore, rapid screening of these biocides is very important for proper control and regulation of potentially hazardous substances. To this end, low-temperature plasma (LTP) ionization mass spectrometry (MS) was investigated to demonstrate its potential for direct and selective analysis of isothiazolinones from sprayed aerosol samples. Benzisothiazolinone (BIT) was clearly identified from a commercial fabric deodorant using LTP ionization MS and MS/MS. LTP allowed selective ionization of BIT directly from the simply sprayed aerosol sample and illustrated its potential for fast screening without sample pre-treatments. Selective nature of LTP ionization, on the other hands, implicates use of LTP ionization MS as a general screening method for specific groups of hazardous chemicals in commercial products.

Agglomeration of Toner Particles with Fatty Alcohol and Their Removal by Screening (고급알코올을 이용한 토너의 응집 및 스크리닝을 통한 제거 효과)

  • 허용성;이학래
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.2
    • /
    • pp.24-32
    • /
    • 2004
  • Toner used in xerographic printing process is hydrophobic powder with low surface energy. The toner ink film fused on paper surface can be efficiently detached from a fiber surface during pulping, but it does not fragment again into fine toner particles. Ink agglomerates that result have too large particle size to be deinked by flotation. The purpose of this study is to enhance toner agglomeration using 1-octadecanol for improving the toner removal by screening. The effect of pH, pulping temperature, and 1-octadecanol on toner agglomeration and removal by screening was investigated using image analysis methods. Results showed that the size of toner agglomerates increased substantially when pulping was carried out at high temperature under acidic condition. When toner agglomerates showed spherical shape, the particle removal efficiency of screening was improved.

Re-SSS: Rebalancing Imbalanced Data Using Safe Sample Screening

  • Shi, Hongbo;Chen, Xin;Guo, Min
    • Journal of Information Processing Systems
    • /
    • v.17 no.1
    • /
    • pp.89-106
    • /
    • 2021
  • Different samples can have different effects on learning support vector machine (SVM) classifiers. To rebalance an imbalanced dataset, it is reasonable to reduce non-informative samples and add informative samples for learning classifiers. Safe sample screening can identify a part of non-informative samples and retain informative samples. This study developed a resampling algorithm for Rebalancing imbalanced data using Safe Sample Screening (Re-SSS), which is composed of selecting Informative Samples (Re-SSS-IS) and rebalancing via a Weighted SMOTE (Re-SSS-WSMOTE). The Re-SSS-IS selects informative samples from the majority class, and determines a suitable regularization parameter for SVM, while the Re-SSS-WSMOTE generates informative minority samples. Both Re-SSS-IS and Re-SSS-WSMOTE are based on safe sampling screening. The experimental results show that Re-SSS can effectively improve the classification performance of imbalanced classification problems.

Worldwide national intervention of developmental screening programs in infant and early childhood

  • Kim, Seunghyo
    • Clinical and Experimental Pediatrics
    • /
    • v.65 no.1
    • /
    • pp.10-20
    • /
    • 2022
  • The prevalence of developmental disabilities is increasing worldwide over time. Developmental issues in infancy or early childhood may cause learning difficulties or behavioral problem in school age, further adversely affecting adolescent quality of life, which finally lead to low socioeconomic status in family, increase in medical expenses, and other relevant issues in various ways. Early childhood has brain plasticity, which means there is a high chance of recovering from developmental issues by early detection and timely intervention. Pediatricians are placed an ideal position to meet with young children till 6 years of age, of which age range is the time applicable to early intervention. Determining child's developmental status can be made by 2 pathways such as developmental surveillance and developmental screening tests. For better results, pediatricians should update their knowledge about developmental issues, risk factors, and screening techniques through varying educational program or other relevant educating materials. This paper will update reports on the prevalence of developmental disabilities and review the recent results of the Korean developmental screening test and discuss relevant issues. Finally, it will be addressed the pediatrician's role in early detecting developmental issues and timely intervention.

Abbreviated Magnetic Resonance Imaging for Breast Cancer Screening: Concept, Early Results, and Considerations

  • Eun Sook Ko;Elizabeth A. Morris
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.533-541
    • /
    • 2019
  • Breast magnetic resonance imaging (MRI) has been increasingly utilized, especially in screening for high-risk cases, because of its high sensitivity and superior ability to detect cancers as compared with mammography and ultrasound. Several limitations such as higher cost, longer examination time, longer interpretation time, and low availability have hindered the wider application of MRI, especially for screening of average-risk women. To overcome some of these limitations and increase access to MRI screening, an abbreviated breast MRI protocol has been introduced. Abbreviated breast MRI is becoming popular and challenges the status quo. This review aims to present an overview of abbreviated MRI, discuss the current findings, and introduce ongoing prospective trials.

Characterization of the KG1a Cell Line for Use in a Cell Migration Based Screening Assay

  • Bernhard O. Palsson;Karl francis;Lee, Gyun-Min
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.3
    • /
    • pp.178-184
    • /
    • 2002
  • High-throughput screening has become a popular method used to identify new “leads”for potentially therapeutic compounds. Further screening of these lead compounds is typically done with secondary assays which may utilize living, functioning cells as screening tools. A problem (or benefit) with these cell-based assays is that living cells are very sensitive to their environment. We have been interested in the process of stem cell migration and how it relates to the cellular therapy of bone marrow transplantation. In this study we describe a secondary, cell-based assay for screening the effects of various in-vitro conditions on Immature Hematopoietic Cell (IHC) migration. Our results have revealed many subtle factors, such as the cell's adhesive characteristics, or the effect of a culture's growth phase, that need to be accounted for in a screening protocol. Finally, we show that exponentially glowing KG1a cells (a human IHC cell line) were 10 times more motile than those in the lag or stationary phases. These data strongly suggest that KG1a cells secrete a chemokinetic factor during the exponential growth phase of a culture.