• 제목/요약/키워드: Screen X

검색결과 323건 처리시간 0.03초

PZT/BT 이종 세라믹의 특성 (Characteristics of PZT/BT Multilayered thick film using Sol-gel Process)

  • 이상헌;이영희;이성갑
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.365-366
    • /
    • 2005
  • PZT films are the most intensively investigated because PZT has advantages such as low processing temperature and large remnant values. In this paper, the microstructure and electric properties of $Pb(Zr_x,Ti_{(1-x)})O_3/BaTiO_3$ heterolayered thick films with Zr mole ranging from 30 to 70 % screen printed onto a alumina substrate were studied. $Pb(Zr_x,Ti_{(1-x)})O_3$ and $BaTiO_3$ powders were prepared by the sol-gel method. The $BaTiO_3$ powders were calcined at $700^{\circ}C$ for 2 hours. Structural properties of $Pb(Zr_x,Ti_{(1-x)})O_3/BaTiO_3$ multilayered thick films were investigated. As a result of the X-ray diffraction (XRD) analysis, $Pb(Zr_x,Ti_{(1-x)})O_3/BaTiO_3$ exhibited a perovskite polycrystalline phase without pyrochlore phase or any preferred orientation.

  • PDF

음성인식 기반 인터렉티브 미디어아트의 연구 - 소리-시각 인터렉티브 설치미술 "Water Music" 을 중심으로-

  • 이명학;강성일;김봉화;김규정
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2008년도 학술대회 1부
    • /
    • pp.354-359
    • /
    • 2008
  • 소리-시각 인터랙티브 설치미술인 "Water Music" 은 관객의 음성에 따라서 변하는 물결의 파동을 표현한다. 음정인식 기반 인터페이스 기술을 이용하여 벽면에 비디오 프로젝션 된 시각적 물결이미지로 나타난다. 물결이미지는 동양화의 붓으로 그린 물결과 작은 원형의 입자들을 생성하여 표현된 영상으로 구성된다. 관객은 입김을 불어 넣거나 소리를 냄으로써 화면에서 연속적으로 생성되는 컴퓨터 프로그램 기반 물결의 움직임과 상호 반응할 수 있다. 이러한 공생적인 소리 시각 환경은 관객에게 생각으로 그리고 신체적으로 환영적 공간을 경험하도록 한다. 본 설치작업에서 관객과 상호 반응 할 수 있는 움직이는 물결을 생성하기 위하여 적용된 주요 프로그램은 Visual C++ and DirectX SDK이며, 풀 프레임 3D 렌더링 기술과 파티클 시스템이 사용되었다.

  • PDF

실시간 고화질 영상에 대한 웹기반의 HLS 멀티뷰 시스템 설계 (Web-based HLS(Http Live Streaming) Multi-view System for Real-time High Quality Video)

  • 김대진
    • 한국콘텐츠학회논문지
    • /
    • 제17권11호
    • /
    • pp.312-318
    • /
    • 2017
  • 최근 고화질 영상 입력장치가 일반화 되고 있으며, 실시간으로 입력된 영상을 한 곳에서 동시에 볼 수 있는 중앙관제시스템이 필수 요소가 되고 있다. 이때 프로그램을 따로 설치하지 않고, 웹을 통한 접근을 하려는 시도들이 있으나, 여러 개의 고화질 영상을 동시에 웹 브라우저를 통해 시청하려하면, 웹 브라우저가 강제 종료되는 현상이 발생된다. 본 논문에서는 실시간 고화질 영상에 대한 웹기반의 HLS 멀티뷰 시스템을 제안한다. 화면으로 보이는 멀티뷰 화면을 트랜스코딩을 통해서 재구성하였고, 보안의 취약점이 있는 ActiveX를 사용하지 않으면서도, 통시에 웹브라우저를 통해서 여러 영상 입력을 모니터링 할 수 있는 시스템을 구현 하였다.

스크린 인쇄법에 의해 제조한 PMW-PZT 후막의 특성 (Characterization of PMW-PZT Thick Films Prepared by Screen Printing Method)

  • 손진호;김용범;천채일;유광수;김태송
    • 한국세라믹학회지
    • /
    • 제41권1호
    • /
    • pp.30-35
    • /
    • 2004
  • 스크린 인쇄법 및 PZT sol 처리의 복합공정을 적용하여 $30{\mu}m$ 두께의 PMW-PZT 후막을 Pt/$TiO_2$/$SiN_x$Si 기판위에 제작하였다. 그 결과 PZT sol 처리 횟수가 증가함에 따라 후막의 소결 밀도가 증가하고 전기적, 압전 특성의 증진되는 것을 관찰할 수 있었다. $800^{\circ}C$에서 소결한 10회 sol 처리한 PMW-PZT 후막은 745의 유전상수 및 155 pC/N의 $d_33$ 값을 나타내었다.

고온/고습 조건이 스크린 프린팅 Ag와 Polyimide의 필 강도에 미치는 영향 (Effects of Temperature/Humidity Treatment Conditions on the Peel Strength between Screen-printed Ag and Polyimide Films)

  • 이현철;배병현;손기락;김가희;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제29권2호
    • /
    • pp.43-48
    • /
    • 2022
  • 인쇄전자소자의 금속배선 적용을 위해 스크린 프린팅 Ag/폴리이미드(polyimide, PI) 사이의 계면접착력을 85℃/85% 상대습도의 고온/고습 처리 시간에 따라 PI 필링을 통한 90° 필 테스트로 평가하였다. 고온/고습 처리 전 필 강도는 약 25.99±1.47 gf/mm이었고, 500시간 동안 고온/고습 처리 후 필 강도는 6.05±0.54 gf/mm까지 지속적으로 감소하였다. 박리 파면에 대해 X-선 광전자 분광법 분석 결과, 이는 Ag/PI 계면으로 수분이 지속적으로 침투하여 계면 근처 PI 일부가 가수분해되어 weak boundary layer를 형성하기 때문이고, 이로 인해 고온/고습 처리 전 Ag/PI 계면 박리모드가 고온/고습 처리 후 계면 근처 PI의 얕은 내부 박리 모드로 변경된 것으로 판단된다.

증감지의 X-선 에너지 유효 이용에 관한 연구 (Studies on Effective Utilization of X -ray Energy Using Intensifying Screens)

  • 김영근;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.825-828
    • /
    • 1998
  • The X-ray spectra dependence for intensifying screens of medical radiography was investigated through analysis of the absorbed coefficiency($\mu$), absorbed efficiency(${\eta}_{\alpha}$) and absorbed ratio(R). It was found that the absorbed coefficiency was increased in the order of $CaWO_4$$CaWO_4$ screen showed the highest value.

  • PDF

선량과 선질에 따른 형광량계 응답특성 (The Response of Fluorescence Meter according to X-ray dose and quality)

  • 김정민;김명준;윤종민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권1호
    • /
    • pp.71-75
    • /
    • 1995
  • In order to establish the photographic effects and sensitivity of various screens, fluorescence meter is used with convenience. When the radiation quality has been fixed the fluorescence has increased in proportion to X-ray dose. However, the response of fluorescence meter has the dependency of X-ray quality in accordance with KVP. as well as the difference of screen and scatter fraction can influence on the response of fluorescence meter. Using accurate fluorescence meter as a radiation detecter and as for a proper supervision the sensitive materials, we have to aware of the meter's dependency of X-ray quality and the scatter fraction.

  • PDF

X선 진단영역에서 중원소(Ho) 여과판 사용에 따른 피폭선량 감소와 대조도 개선에 관한 연구 (A Study on the Reduction of Exposure Dose and Contrast Improvement by Use of Heavy Elements Filter)

  • 김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권1호
    • /
    • pp.91-96
    • /
    • 2000
  • This work was on the reduction of exposure dose and contrast improvement by Use of Heavy Elements Filter From the result of experimental evaluation, it was found that the beam harding of X-ray was not showed in Ho and Gd, heavy elements filters, contrast to Cu and Al filters In which the harding showed. And the ratio of transit dose to surface dose and the load of X-ray tube increase in order of Al, Cu, Gd and Ho, respectively. The contrast of X-ray images using the intensifying screen and the input phosphor showed the higher value in order of Cu, Al, Gd and Ho. Therefore, in the case of using contrast media and phosphor in region of diagnostic radiology, X-ray image quality depends primarily on kVp and heavy elements filters.

  • PDF

$Al_{2}O_{3}$가 첨가된 BSCT 후막의 유전특성 (Dielectric Properties of $Al_{2}O_{3}-Doped$ BSCT Thick Films)

  • 이성갑;김창일;김정필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.338-341
    • /
    • 2002
  • $(Ba_{1-x}Sr_{0.4}Ca_x)TiO_{3}$ (x=0.10, 0.15, 0.20) powders were prepared by the sol-gel method and BSCT thick films were fabricated by the screen-printing method. Their structural and dielectric properties were investigated with variation of composition ratio and $Al_{2}O_{3}$ doping contents. As results of the X-ray diffraction and microstructure analysis, the grain size of BSCT thick films was decreased with increasing $Al_{2}O_{3}$ amount. The thickness of BSCT thick films by 4-coating/drying is about $110{\sim}120{\mu}m$. The tunability increased with decreasing Ca content, and the BSCT(50/40/10) specimen doped with 1.0wt% $Al_{2}O_{3}$ showed the highest value of 12.94% at 5kV /cm.

  • PDF

증감지를 이용한 방사선검출기 개발 (Development of Radiation Detector with Intensifying Screen)

  • 서정민
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.859-863
    • /
    • 2023
  • 본 연구에서는 엑스선 증감지와 광센서, 마이크로컨트롤러(MCU)를 이용하여 휴대와 이동이 용이한 교육용 방사선검출기를 제안하였다. 광센서와 증감지로 이루어진 검출부와 마이크로컨트롤부로 간단하게 구성되어 제작이 쉽고 소형화 및 휴대형으로 적합하게 제작되었다. 검출기의 성능 확인을 위해 전압을 50에서 100 kVp까지 변경하며 검출시스템과 흡수선량계를 이용하여 방사선을 측정하였다. 관전류량은 100 mAs, SDD는 100 cm로 고정하였고 각 관전압에서 10회 반복 측정하였다. 측정값을 이용하여 검출기의 응답과 선형성을 확인하였다. 검출기와 흡수선량계의 측정결과 비교에서 높은 상관성(r:0.998, p<.001)을 보임을 확인하였다. 이러한 결과를 통하여 본 연구에서 제안된 증감지와 마이크로컨트롤러 기반의 검출기의 사용가능성을 확인할 수 있었으며, 휴대형 방사선검출시스템이 소형, 저가형, 휴대형 시스템으로 교육용으로 적용이 가능할 것으로 판단되었다.