• Title/Summary/Keyword: Scratch 3.0

Search Result 69, Processing Time 0.025 seconds

A Study on the standardize the characteristic evaluation of DC magnetron sputtered silver coatings for engineering purposes (D.C. magnetron sputter를 이용한 Ag layer 건식 도금층의 특성 평가 국제 표준화에 대한 연구)

  • Gyawali, Gobinda;Choi, Jinhyuk;Lim, Tae Kwan;Jung, Myoung Joon;Lee, Soo Wohn
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.249-249
    • /
    • 2015
  • Silver films have been of considerable interest for years due to their better performance relative to other metal films for engineering applications. A series of multi-layer silver coatings with different thickness (i.e. 0.3 um to 1.5 um) were prepared on Aluminium substrate containing copper undercoat by direct current (DC) magnetron sputtering method. For the comparative purpose, similar thickness silver coatings were prepared by electrolytic deposition method. Microstructural, morphological, and mechanical characteristics of the silver coatings were evaluated by means of scanning electron microscope (SEM), X-ray diffraction (XRD), Surface roughness test, microhardness test and nano-scratch test. From the results, it has been elucidated that the silver films prepared by DC magnetron sputtering method has superior properties in comparison to the wet coating method. On the other hand, DC magnetron sputtering method is relatively easier, faster, eco-friendly and more productive than the electrolytic deposition method that uses several kinds of hazardous chemicals for bath formulation. Therefore, a New Work Item Proposal (NWIP) for the test methods standardization of DC magnetron sputtered silver coatings has recently been proposed via KATS, Korea and a NP ballot is being progressed within a technical committee "ISO/TC107-metallic and other inorganic coating".

  • PDF

THE AMOUT OF LOSS AND THE DEGREE OF SURFACE SMOOTHNESS OF GOLD ALLOY BY GOLD ALLOY POLISHING RUBBER POINT MATERIALS (금합금 연마재 종류에 따른 금합금 소실량과 연마 정도)

  • Kim, Myoung-Hwa;Yim, Soon-Ho;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.277-295
    • /
    • 1997
  • After clinical adjustment of dental casting restoration, re-polishing procedure is recommanded because the smooth gold sureface is lost. But there is the possibility to get more loose contact than that intended by loss of gold alloy according to the kinds of polishing materials and polishing time. Therefore in this study I polished type II gold alloy with 390gm force, 20,000rpm speed, and 8 kinds of gold alloy polishing materials, fabricated by 4 companies and then measured the amount of loss of gold alloy with Surfcorder SEF-30D and observed alloy surfaces polished by 3 brown rubber points with SEM. The amount of loss of gold alloys polished with 8 kinds of polishing materials and the degree of smoothness of gold alloys according to polishing time and polishing materials were compared. The following results were obtained : 1. When the amount of loss of gold alloys polished with 3 kinds of brown rubber point was compared, Alphalex brown point had the most amount of alloy loss, followed in decreasing order by Shofu brown point and Eveflex brown point. There was statistically significant difference in the amount of alloy loss according to polishing materials. 2. When the amount of loss of gold alloys polished with 5 kinds of green rubber point was compared, Shofu green point had the most amount of alloy loss, followed in decreasing order by Alphaflex green point, Dedeco green clasp polisher, and Eveflex green point. There was statistically significant difference in the amount of alloy loss according to polishing materials except Alphaflex green point and Dedeco green clasp polisher. 3. When the amount of loss of gold alloys polished with all kinds of rubber point was compared, there was no significant difference in Eveflex brown point, Alphaflex green point, and Dedeco green clasp polisher. 4. When average amount of alloy loss per 1 revolution by polishing materials was compared, Alphalex brown point had the greatest value as $0.329{\mu}m$ and Shofu supergreen point had the lowest value as $0.022{\mu}m$. 5. When the degree of sureface smoothness of gold alloy polished with 3 kinds of brown rubber point was compared, In Alphalex brown point surface roughness was completely lost after 20 seconds polishing time, in Shofu brown point 30 seconds, in Eveflex brown point 40 seconds. But in every gold alloys fine scratch formed by rubber points was observed. Based on the results of this study, as rubber polishing materials used in polishing of dental casting restoration after clinical adjustment influenced on the tightness of occlusal or proximal contact, we should make dental casting restoration with minimum error through careful laboratory procedure and form very smooth surface of restoration with tripoli and rouge after use of silicone polishing materials.

  • PDF

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

The Effects of Treatment Dumbbell Exercise on Body Composition, Fitness, and Blood Lipid Profiles in Sarcopenic Elderly (미용덤벨 운동이 노인의 근감소증 예방을 위한 신체조성, 체력 및 혈중지질에 미치는 영향)

  • So, Wi-Young;Song, Mi-Soon;Cho, Be-Long;Park, Yeon-Hwan;Kim, Yeon-Soo;Lim, Jae-Young;Kim, Seon-Ho;Song, Wook
    • 한국노년학
    • /
    • v.29 no.3
    • /
    • pp.837-850
    • /
    • 2009
  • Previous epidemiological studies reported that significant muscle loss is observed with advancing aging, called sarcopenia. This study is to investigate the effects of treatment dumbbell exercise on prevention of sarcopenia. The subjects were elderly between 60~70 years old who participated in J-Welfare senior center exercise program at J-gu in S-city and divided into control group(N=19) and exercise group(N=8). Treatment dumbbell exercise was performed 2 times per week for 12 weeks and body composition, fitness, and blood lipid profiles were measured before and after this program. There was no significance in body fat before and after 12 weeks of treatment dumbbell exercise, but there was significance in weight(F=4.312, p=0.048), BMI(F=4.532, p=0.043), and FFM(F=4.743, p=0.039). There was no significance in fitness such as arm curl(F=1.103, p=0.304), and back scratch(F=0.214, p=0.648), but there was significance in 2-minute step(F=33.638, p<0.001), chair stand(F=14.575, p=0.001), chair sit and reach(F=7.198, p=0.013), and 8-ft up and go(F=14.890, p=0.001). The variables of blood lipid profiles such as TC(F=0.030, p=0.864), TG(F=0.142, p=0.710), HDL(F=2.066, p=0.163), glucose (F=0.125, p=0.727), and HbA1c(F=0.945, p=0.340) has no significance. It was found that treatment dumbbell exercise has positive effects on body composition and fitness but has no positive effects on blood lipid profiles of the elderly.

A Scanning electron microscopic study of enamel surface by debracketing of ceramic bracket (도재브라켓의 제거방법에 따른 법랑질표면의 주사전자현미경학적 관찰)

  • Park, Mi-Suk;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.613-622
    • /
    • 1996
  • The purposes of this study were to evaluate and compare the frequency of ceramic bracket fracture, frequency of enamel fracture, bond fracture site, adhesive remnant index after mechanical and electrothermal debracketing, to evaluate effectiveness of high and low speed rotary instrument and ultrasonic instrument during residual adhesive remnants removal, and to measure resin film surface(percentage) using by image analyser(Leco 300). Bond fracture site, bracket fracture, and enamel surface damage were examined by scanning electron microscope. The following results were obained : 1. In the mechanical debracketing group, the bond failed predominantly at enamel-adhesive interface with the bulk of adhesive remaining on bracket base. 2. In the eletrothermal debracketing group, the bond failed predominantly at adhesive-bracket interface with the bulk of adhesive remaining on enamel surface. 3. The most effectiveness of residual resin removal was obtained by means of the resin polishing bur and the order of scratch formation was the procedure using tungsten carbide bur, ultrasonic scaler, sof-lex disc, and polishing bur. 4. The order of the resin film surface percentage was ultrasonic scaler, tungsten carbide bur, sof-lex disc, and resin polishing bur.

  • PDF

Foreign Body in the Gastrointestinal Tract in Children (소아의 위장관 이물질에 대한 임상적 고찰)

  • Lee, Bo-Hyeong;Lee, Hyun-Kyung;Kim, Mi-Jung;Choi, Kwang-Hae
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.75-84
    • /
    • 2001
  • Background: The accidental swallowing of foreign body is a common problem in the children. Ingested foreign bodies may be managed by endoscopy, observation, or surgery. So we analyzed the methods of removal, type, location and complications of foreign bodies. Materials and Methods: This report reviewed 37 cases of ingested foreign body in the gastrointestinal tract at the Department of Pediatrics, Yeungnam University Hospital between January 1997 and April 2001. Results: The age ranged from 8 months to 8 years. The most prevalent age group was between 1 year and 2 years of age(19%). The male to female ratio was 2.1:1 with 25 male and 12 female patients. The type of foreign bodies were coins in 20 cases(54%), nail in 4 cases(11%), key in 4 cases(11%), pin in 2 cases(5.5%), necklace in 2 cases(5.5%) and others. The locations of foreign bodies were upper esophagus in 12 cases(32.5%), lower esophagus in 4 cases(10.8%), stomach in 16 cases(43.2%), small bowel in 5 cases(13.5%). 4. Presenting symptoms were variable with asymptomatic(59.4%), vomiting(19.0%), epigastric pain(8.1%), dysphagia(5.4%) and others. The methods for removal of foreign bodies included 20 cases of endoscopic removal(54.0%). 3 cases of spontaneous removal(8.1%) and there was no surgical removal. 14 cases(37.9%) did not confirmed removal of foreign body because of no revisit of our hospital. Endoscopic finding of patients were normal(15 cases), ulceration(2 cases), erosion(1 case), inflammation(1 case), mucosal scratch(1 case). Conclusion: It appears that the endoscopic approach is the preferable method for the removal of upper gastrointestinal foreign bodies in the children.

  • PDF

Anti-metastatic Effects on B16F10 Melanoma Cells of Extracts and Two Prenylated Xanthones Isolated from Maclura amboinensis Bl. Roots

  • Siripong, Pongpun;Rassamee, Kitiya;Piyaviriyakul, Suratsawadee;Yahuafai, Jantana;Kanokmedhakul, Kwanjai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.7
    • /
    • pp.3519-3528
    • /
    • 2012
  • Inhibitory effects of Maclura amboinenesis Bl, one plant used traditionally for the treatment of cancers, on metastatic potential of highly metastatic B16F10 melanoma cells were investigated in vitro. Cell proliferation was assessed using the MTT colorimetric assay. Details of metastatic capabilities including invasion, migration and adhesion of B16F10 melanoma cells were examined by Boyden Chamber invasion and migration, scratch motility and cell attachment assays, respectively. The results demonstrated that n-hexane and chloroform extracts exhibited potent anti-proliferative effects (p<0.01), whereas the methanol and aqueous extracts had less pronounced effects after 24 h exposure. Bioactivity-guided chromatographic fractionation of both active n-hexane and chloroform extracts led to the isolation of two main prenylated xanthones and characterization as macluraxanthone and gerontoxanthone-I, respectively, their structures being identified by comparison with the spectral data. Interestingly, both exhibited potent effective effects. At non-toxic effective doses, n-hexane and chloroform extracts (10 and $30{\mu}g/ml$) as well as macluraxanthone and gerontoxanthone-I (3 and $10{\mu}M$) significantly inhibited B16F10 cell invasion, to a greater extent than $10{\mu}m$ doxorubicin, while reducing migration of cancer cells without cellular cytotoxicity. Moreover, exposure of B16F10 melanoma cells to high concentrations of chloroform ($30{\mu}g/ml$) and geratoxanthone-I ($20{\mu}M$) for 24 h resulted in delayed adhesion and retarded colonization. As insights into mechanisms of action, typical morphological changes of apoptotic cells e.g. membrane blebbing, chromatin condensation, nuclear fragmentation, apoptotic bodies and loss of adhesion as well as cell cycle arrest in the G1 phase with increase of sub-G1 cell proportions, detected by Hoechst 33342 staining and flow cytometry were observed, suggesting DNA damage and subsequent apoptotic cell death. Taken together, our findings indicate for the first time that active n-hexane and chloroform extracts as well as macluraxanthone and gerontoxanthone-I isolated from Maclura amboinensis Bl. roots affect multistep of cancer metastasis processes including proliferation, adhesion, invasion and migration, possibly through induction of apoptosis of highly metastatic B16F10 melanoma cells. Based on these data, M. amboinensis Bl. represents a potential candidate novel chemopreventive and/or chemotherapeutic agent. Additionally, they also support its ethno-medicinal usage for cancer prevention and/or chemotherapy.

MicroRNA-101 Inhibits Cell Proliferation, Invasion, and Promotes Apoptosis by Regulating Cyclooxygenase-2 in Hela Cervical Carcinoma Cells

  • Huang, Fei;Lin, Chen;Shi, Yong-Hua;Kuerban, Gulinar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5915-5920
    • /
    • 2013
  • Aim: Although aberrant miRNA expression has been documented, altered miR-101 expression in cervical cancer and its carcinogenic effects and mechanisms remain unexplored. The aim of our study was to investigate the role of miR-101 alteration in cervical carcinogenesis. Methods: Expression of miR-101 was examined by quantitative real-time reverse transcriptase PCR (qRT-PCR) in Hela cells. After modulating miR-101 expression using miR-101 mimics, cell growth, apoptosis and proliferation, and migration were tested separately by MTT or flow cytometry and cell wound healing assay and protein expression was detected by qRT-PCR. The expression of COX-2 in Hela cell was also examined by immunohistochemical staining and the correlation with miR-101 expression was analysed. Results: The miR-101 demonstrated significantly low expression in Hela cell. When we transfected miR-101 mimics into Hela cells, the modulation of miR-101 expression remarkably influenced cell proliferation, cycling and apoptosis: 1) The expression of microRNA-101 tended to increase after transfection; 2) Overexpression of miR-101 was able to promote cell apoptosis, the apoptosis rate being markedly higher (97.6%) than that seen pre-transfection (12.2%) (P<0.05); 3) The miR-101 negatively regulates cell migration and invasion, scratch results being lower ($42.7um{\pm}2um$) than that observed pre-transfection ($181.4um{\pm}2um$); 4) miRNA-101 inhibits the proliferation of Hela cells as well as the level of COX-2 protein, which was negatively correlated with miR-101 expression. Conclusions: Overexpression of miR-101 has obvious inhibitory effects on cell proliferation, migration and invasion. Thus reduced miR-101 expression could participate in the development of cervical cancer at least partly through loss of inhibition of target gene COX-2, which probably occurs in a relative late phase of carcinogenesis. Our data suggest an important role of miR-101 in the molecular etiology of cancer and indicate potential application of miR-101 in cancer therapy.

Does Sarcopenic Obesity Affect Physical Function and Physical Fitness of Korean Older Women? (근위축비만이 국내 여성고령자의 신체기능과 체력에 미치는 영향)

  • Hong, Seung-youn
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.831-842
    • /
    • 2010
  • BACKGROUND: Sarcopenic obesity(SO), a condition of the reduction in muscle mass paired with an increased fat mass has been paid attention because of its association with disability in later life. A few evidence, however, has reported the association with these factors. PURPOSE: To explore the association among SO, physical function and fitness in older women. METHOD: 257 older women(age of 74) were recruited from Y city and 7 physical functions and 4 fitness tests were measured. Participants were classified into one of four groups based on their body fat and muscle mass: Normal group (GR-A), high fat(GR-B), sarcopenia(GR-C), and sarcopenic obese(GR-D). GLMand LSD-test were conducted with SPSS 12.0. RESULTS: Chair stand, arm-curl, back-scratch, 2-min steps of GR-A was higher than GR-C and GR-D(p<.05). One-leg stand of GR-A was higher than GR-D(p<.01) and of GR-C was higher than GR-D(p<.01).8ft-TUG of GR-D was lower than GR-A(p<.01). Grip strength, knee extension of GR-A was higher than that of GR-C and GR-D(p<.01) and knee flexion of GR-A was also higher than that of GR-C and GR-D(p<.01). CONCLUSION: Based on our findings, we conclude that SO is significantly associated with lower physical function and fitness in older Korean women, which alarm the risk of frailty induced by SO.