• Title/Summary/Keyword: Scoliosis Images

Search Result 15, Processing Time 0.018 seconds

Surgical Outcomes and Complications Following All Posterior Approach for Spinal Deformity Associated with Neurofibromatosis Type-1

  • Park, Byoung-Joo;Hyun, Seung-Jae;Wui, Seong-Hyun;Jung, Jong-Myung;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.6
    • /
    • pp.738-746
    • /
    • 2020
  • Objectives : The purpose of this study was to evaluate surgical outcomes and complications of spinal deformity associated with neurofibromatosis type-1 (NF-1). Methods : From 2012 to 2018, patients suffering from spinal deformity associated with NF-1 who underwent surgical correction were identified. Demographic data and radiographic measures were retrospectively reviewed. Pre- and postoperative whole spine radiograph images were used to determine both coronal and sagittal Cobb angles. All of patients underwent 3-dimentional computed tomographic scan and magnetic resonance imaging scan to confirm dystrophic features. For evaluation of clinical outcomes, we surveyed the pre- and postoperative scoliosis research society-22r (SRS-22r) score. Results : Seven patients with spinal deformity associated with NF-1 were enrolled in this study. The mean age of patients was 29.5±1.2 years old. The mean follow-up period was 2.8±1.4 years. The apex of the deformity was located in cervicothoracic (n=1), thoracic (n=4), and lumbar region (n=2). Most patients have poor bone quality and decreased bone mineral density with average T-score of -3.5±1.0. All patients underwent surgical correction via posterior approach. The pre- and postoperative mean coronal and sagittal Cobb angle was 61.6±22.6° and 34.6±38.1°, 56.8±18.5° and 40.2±9.1°, respectively. Mean correction rate of coronal and sagittal angle was 44.7% and 23.1%. Ultimate follow-up SRS-22r score (average score, 3.9±0.4) improved comparing to preoperative score (average score, 3.3±0.9). Only one patient received revision surgery due to rod fracture. No serious complication occurred, such as neurological deficit, and viscerovascular injury. Conclusion : The surgical correction of patients having spinal deformity associated with NF-1 is challenging, however the radiographic and clinical outcomes are satisfactory. The all posterior approach can be a safe and effective surgical option for patients having dystrophic curves associated with NF-1.

Percutaneous Sacroplasty : Effectiveness and Long-Term Outcome Predictors

  • Lee, Jaehyung;Lee, Eugene;Lee, Joon Woo;Kang, Yusuhn;Ahn, Joong Mo;Kang, Heung Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.6
    • /
    • pp.747-756
    • /
    • 2020
  • Objective : To evaluate the effectiveness and long-term outcome predictors of percutaneous sacroplasty (PSP). Methods : This single-center study assessed 40 patients with sacral insufficiency fractures using the short-axis technique under C-arm flat-panel detector computed tomography (CT). Two radiologists reviewed the patients' magnetic resonance and CT images to obtain imaging findings before PSP and determine technical success, respectively. The short-term outcomes were visual analog scale score changes and opioid usage reductions. Long-term outcomes were determined using telephone interviews and the North American Spine Society (NASS) patient-satisfaction index at least one year after PSP. Results : Technical success was achieved without any significant complications in 39 patients (97.5%). Telephone interviews were possible with 12 patients and failed in 10 patients; death was confirmed in 18 patients. Fifteen patients (50%) re-visited the hospital and received conservative treatment, including spinal injections. Nine patients reported positive satisfaction (NASS patient-satisfaction index 1 or 2), while the negative satisfaction group (NASS patient-satisfaction index 3 or 4, n=3) showed a higher incidence of compression fractures at the thoracolumbar spine level (66.7% vs. 22.2%) and previous spinal injection history (66.7% vs. 33.3%). The poor response group also showed higher incidences of facet joint arthrosis (100% vs. 55.6%), central canal stenosis (100% vs. 22.2%), neural foraminal stenosis (33.3% vs. 22.2%), scoliosis (100% vs. 33.3%), and sagittal malalignment (100% vs. 44.4%). Conclusion : PSP was effective for sacral insufficiency fractures and showed good long-term outcomes. Combined compression fractures in the thoracolumbar spine and degenerative lumbar pathologies could be possible poor outcome predictors.

Three-dimensional Reconstruction of X-ray Imagery Using Photogrammetric Technique (사진측량기법을 이용한 엑스선영상의 3차원 모형화)

  • Kim, Eui Myoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2D
    • /
    • pp.277-285
    • /
    • 2008
  • X-ray images are wildly used in medical applications, and these can be more efficiently find scoliosis which is appearing during the growth of human skeleton than others. This research is focused on the calibration of X-ray image and three-dimensional coordinate determination of objects. Three-dimensional coordinate of objects taken by X-ray are determined by two step procedure. Firstly, interior and exterior orientation parameters are determined by camera calibration using Primary Calibration Object (PCO) which has two sides with embedded radiopaque steel ball. Secondly, calibration cage coordinates which is composed of two acrylic sheets that are perpendicular to X-ray source are determined by the parameters. Three-dimensional coordinates of calibration cage determined by photogrammetric technique are compared with that of Coordinate Measuring Machine (CMM). Though the accuracy analysis, X direction which is parallel to X-ray source error values are relatively higher than those of Y and Z directions. But, the accuracies of Y and Z axis are approximately -3 mm to 3 mm. From the research results, it is considered that photogrammetric technique is applied to determine three-dimensional coordinates of patients or assist to make medical devices.

Improved Fuzzy Binarization Method with Trapezoid type Membership Function and Adaptive α_cut (사다리꼴 형태의 소속 함수와 동적 α_cut 을이용한 개선된 퍼지 이진화)

  • Woo, Hyun-su;Kim, Kwang-baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1852-1859
    • /
    • 2016
  • The effectiveness of a binarization algorithm in image processing depends on how to eliminate the uncertainty of determining threshold in a reasonable way and on minimizing information loss due to the binarization effect. Fuzzy binarization technique was proposed to handle that uncertainty with fuzzy logic. However, that method is known to be inefficient when the given image has low intensity contrast. In this paper, we propose an improved fuzzy binarization method to overcome such known drawbacks. Our method proposes a trapezoid type fuzzy membership function instead of most-frequently used triangle type one. We also propose an adaptive ${\alpha}$_cut determination policy. Our proposed method has less information loss than other algorithms since we do not use any stretching based preprocessing for enhancing the intensity contrast. In experiment, our proposed method is verified to be more effective in binarization with less information loss for many different types of images with low intensity contrast such as night scenery, lumber scoliosis, and lipoma images.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF