• 제목/요약/키워드: School Ventilation

검색결과 684건 처리시간 0.03초

학교교실의 환경개선 환기시스템 최적화 기반 연구 (Optimization of a Ventilation System for Indoor Environment Improvement in School Building)

  • 서승직;홍성희;박효순;박종훈;장용성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.229-234
    • /
    • 2005
  • This study aims to build basic data for a optimization of a ventilation system for indoor environment improvement in school building. To this end, we conducted field tests and computation fluid dynamics simulations about a indoor environment in dependence on operation of a ceiling type inverter air conditioner and ventilation system. The results could be summarized as follows. (1) For the ventilation system of 350CMH, 500CMH and 850CMH, reduction of each $CO_2$ concentration was measured 662ppm, 748ppm and 526ppm. (2) A optimal discharge angle of the ceiling type inverter air conditioner system was evaluated 45 degree in heating and cooling.

  • PDF

Estimation of Risk from Air Pollution in the Underground Highway Proposed to Construct in Seoul, Korea

  • Lee, Ki-Young;Yukio-Yanagisawa
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제9권E호
    • /
    • pp.397-400
    • /
    • 1993
  • The possible air pollution problems in a proposed underground highway are discussed using carbon monoxide (CO) as an indicator. Carbon monoxide concentrations in the underground highway depend on several factors, including the size of tunnel, the number of automobiles, the CO emission rate, and the tunnel ventilation rate. Using the estimated values, CO concentrations in the underground highway can be predicted. Without proper ventilation system, CO concentration in the underground highway can be dangerous level. However, the cost of operating the mandatory mechanical ventilation system may be tremendouslyy high and may be technically unrealistic to implement. If the underground highway is constructed with proper ventilation system, a continuous air pollution monitoring system with alarming function must be installed to alert personnel of serious air pollution built up in the underground highway. Traffic must be restricted, whenever the inside air pollution levels exceed agreed values. Short distances between evacuation exits are necessary for emergency situations or malfunction of ventilation system.

도로 터널내의 공기유동 양상을 예측하기 위한 수치해석 (Numerical Analysis to Predict Air Flow Phenomena in a Road Tunnel)

  • 최인수;박병덕;윤일로
    • 한국산업융합학회 논문집
    • /
    • 제5권4호
    • /
    • pp.313-320
    • /
    • 2002
  • A 2-dimensional $k-{\varepsilon}$ numerical model was developed to explore the effects of vehicle movement, jet fan and wind speed for the ventilation of road tunnels. To consider the temperature distribution in the tunnel, the energy equation was solved with a source term of the energy exhausted from vehicles. Although the tunnel ventilation can be made by the piston effect of vehicle movement, an additional ventilation is necessary when a head wind is existing. Jet fans may assist the air flow in the tunnel. However, more efficient ventilation system should be necessary, because the exhaust gas from vehicles flow along the road surface and it cannot be diffused in the longitudinal tunnel.

  • PDF

Monte-Carlo 모의실험을 이용한 초·중·고등학교의 환기부족 평가 (Evaluation of Ventilation Deficiecy in Elementary, Middle, and High Schools using Monte Carlo Simulation)

  • 최영태;박진현;김은채;류현수;김동준;민기홍;정다영;우병렬;조만수;양원호
    • 한국환경보건학회지
    • /
    • 제46권6호
    • /
    • pp.627-635
    • /
    • 2020
  • Objectives: Indoor air quality has become more important aspeople spend most of their times indoors. Since students spend most of their times at home or at school, they are more likely to be exposed to indoor air pollutants. Ventilation in school classrooms can affect health and learning performance. In this study, ventilation deficiency was evaluated in school classrooms using Monte Carlo simulation. Methods: This study used sensor-based monitoring for six months to measure carbon dioxide (CO2) concentrations in classrooms in elementary, middle, and high schools. The volume of the classroom and the number of students were investigated, and the students' body surface area was used to calculate the CO2 emission rate. The distribution of ventilation rates was estimated by measured CO2 concentration and a mass-balance model using Monte Carlo simulation. Results: In the elementary, middle, and high schools, the average CO2 concentrations exceeded 1000 ppm, indicating that the ventilation rates were insufficient. The ventilation rates were deficient from July to August and in December, but showed relatively high ventilation rates in October. Forty-three percent of elementary schools, 56% of middle schools, and 62% of high schools showed insufficient ventilation rates. Conclusions: The ventilation rates calculated in elementary, middle and high schools were found to be quite insufficient. Therefore, proper management is needed to overcome the lack of ventilation and improve air quality.

군 내무실의 실내공기질 개선을 위한 환기량 산정에 관한 연구 (A Study on the Calculation of Ventilation Rate for the Improvement of Indoor Air Quality on the Barracks)

  • 최정민;유진상;정영일
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1043-1049
    • /
    • 2005
  • The purpose of this study is to improve indoor air quality of the barracks which have been changed from floor-type living barracks to bed-type living barracks since 2003. Therefore, the ventilation rates of newly constructed two type barracks were simulated with the various building materials including VOCs and HCHO components. And indoor air quality of two type living barracks was measured by the field experiments. With these steps, the measures for upgrading indoor air quality depending on building material types and ventilation rate are suggested.

Contralateral Tension Pneumothorax during One Lung Ventilation by a $Univent^{(R)}$ Tube

  • No, Min-Young;Moon, Sung-Ha;Kim, Hyun-Soo
    • Journal of Yeungnam Medical Science
    • /
    • 제29권1호
    • /
    • pp.31-34
    • /
    • 2012
  • Tension pneumothorax during one-lung ventilation (OLV) is a rare but life-threatening complication. A 79-year-old male patient who was diagnosed with lung cancer underwent $Univent^{(R)}$ Tube (Fuji Systems Corporation, Tokyo) intubation for left upper lobectomy. Two hours after the initiation of OLV, the patient could not tolerate it. Thus, one-and two-lung ventilation were alternatively applied to continue the operation. After the operation, an emergent chest radiograph was taken, and pneumothorax was found at the right (dependent) lung field.

  • PDF

Effectiveness of Ventilation Control in a Dry Room with a Heat and Moisture Source

  • Lee, Kwan-Soo;Lim, Kwang-Ok;Ahn, Kang-Ho;Jung, Young-Sick
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.1-9
    • /
    • 2001
  • The temperature and moisture distributions in a dry room with a heat and moisture source -i.e., workers- are studied numerically by using a standard $k-\varepsilon$ turbulence model. In order to evaluate the effectiveness of heat and moisture ventilation inside the room, the heat removal capacity and the moisture exhaust efficiency are introduced. The effectiveness of ventilation control is analyzed by evaluating the temperature and humidity distributions in the room quantitatively. It is found that the mean absolute humidity inside the room is almost constant regardless of the models and the heat generation rates in this study range. This results from the fact that the moisture generation by the workers was relatively small. Through the modification of the design, 40% improvement in critical decay time was achieved.

  • PDF

Risk factors for persistent otitis media with effusion in children: a case-control study

  • Lee, Ju Yeon;Kim, Se-Hyung;Song, Chan Il;Kim, Young Ree;Kim, Yoon-Joo;Choi, Jae Hong
    • Journal of Yeungnam Medical Science
    • /
    • 제35권1호
    • /
    • pp.70-75
    • /
    • 2018
  • Background: Otitis media with effusion (OME) is defined as middle ear effusion without acute signs of infection. OME usually resolves spontaneously; however, persistent OME may require the insertion of a ventilation tube. This study investigated risk factors for persistent OME in children who undergo ventilation tube insertion. Methods: Children who were admitted to undergo ventilation tube insertion at Jeju National University Hospital between August 2015 and July 2016 were enrolled as the case group. Healthy children without persistent OME from August 2016 to July 2017 were enrolled as the control group. Baseline characteristics and predisposing factor data were collected using an interview questionnaire. Middle ear fluids were collected from the case group. Results: A total of 31 patients underwent ventilation tube insertion. The mean age of the case group was 4.53 years, with a male-to-female ratio of 21:10. Twenty-nine (93.5%) children attended a daycare center, and 21 (67.7%) had experience with bottle feeding. Fifteen (48.4%) children in the case group and 3 (9.7%) in the control group first attended a daycare center at <1 year of age (odds ratio=9.96; 95% confidence interval=2.44-39.70; p=0.001). No bacteria were found in middle ear fluid collected from the 31 operated children. Nasopharyngeal bacterial colonization was found in 13 (41.9%) and 17 (54.8%) children in the case and control groups, respectively. Conclusion: Earlier attendance at a daycare center was the only predisposing factor for ventilation tube insertion in our study. The aseptic nature of middle ear fluids found in children with OME highlights the efficacy of antimicrobial use.

패시브환기외피의 통기성능 및 열관류율에 대한 연구 (A Study on Ventilation and Heat Transfer Coefficient of Passive Ventilation Skin)

  • 이태철;손유남;윤성환
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.679-684
    • /
    • 2012
  • This paper aims to evaluate performances of ventilation and insulation of 6types PVS(Passive ventilation skin) by numerical simulation. The results are as follows. 1) The result of Performance of ventilation by pressure difference, it was shown that the amount of ventilation changed bigger under 1Pa and amount of ventilation increased according to increase opening area (${\alpha}A$). Although same opening area of PVS, it can predict that pressure differences cause ventilation differences. 2) In case of same opening area of PVS, however, it was changed the amount of ventilation each types of PVS that is distinguished opening area by flow coefficient. 3) Dynamic U-value that represents performance of insulation PVS was similar change upper ${\alpha}A40\;cm^2/m^2$, great change in casse of 0.1 Pa pressure difference. In case of ${\alpha}A10\;cm^2/m^2$, it was changed bigger under 0.3 Pa pressure difference, ${\alpha}A20\;cm^2/m^2$ of PVS was changed under 0.2 Pa pressure difference.

Treatment of Idiopathic Persistent Hiccups with Positive Pressure Ventilation - A Case Report -

  • Byun, Sung-Hye;Jeon, Young-Hoon
    • The Korean Journal of Pain
    • /
    • 제25권2호
    • /
    • pp.105-107
    • /
    • 2012
  • A 41-year-old male patient presented with idiopathic persistent hiccups. The hiccups did not respond to pharmacologic treatments including cisapride, omeprazole, and baclofen. Phrenic nerve block was also ineffective. However, the persistent hiccups were successfully treated with short-term positive pressure ventilation using a short-acting muscle relaxant.