• Title/Summary/Keyword: School Outdoor Environment

Search Result 252, Processing Time 0.032 seconds

The Effect of the Ground Composition on Thermal Environment in Multi -residential Building Block (공동주택 단지 내 지반 특성 및 지반 구성에 따른 열적 특성에 관한 연구)

  • Hwang, Hyo-Keun;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.88-97
    • /
    • 2009
  • In these days, it attracts our attention to create a green outdoor environment around the building block in urban area. Green space and permeable ground covering are increased by laws and regulations. According to these trends, variety researches for improving outdoor environment are accomplished at this moment. However, the problems for outdoor environment such as heat island effect and air contaminant in urban area are still reported. The purpose of this study is to examine the variables to affect the formation of outdoor thermal environment by quantitative analysis. As a initial study, in this paper, the effect of ground composition on changes of surface temperature and heat flux in multi-residential building were analyzed by field measurement and numerical simulation. Through field measurement, the surface temperature and heat flux of artificial ground in multi-residential building in Suwon city were measured. The result showed that the surface temperature was decreased by about $20^{\circ}C$ with afforestation of artificial ground compared with those of concrete covering. Moreover, the inner temperature of artificial ground was changed as same behaviors of outdoor temperature changes to depths of 20cm. In simulation, the effect of soil types and depth of artificial ground on the changes of the surface temperature and heat flux were analyzed. As results, the natural soil ground was more effective against lowering the surface temperature than any other cases in the analyzed cases.

Characteristics of Heavy Metal Concentrations and Indoor Atmospheric Environments in Busan Metropolitan Area, Korea

  • Park, Jong-Kil;Kim, Yoo-Kuen;Lee, Hwa-Woon;Jang, Nan-Sim;Park, Moon-Ki
    • Journal of Environmental Science International
    • /
    • v.11 no.8
    • /
    • pp.801-810
    • /
    • 2002
  • The current paper describes the indoor/outdoor air quality in school environments through analyses of the heavy metal concentrations using Inductive Coupled Plasma(ICP). School environments in a heavy traffic area, two industrial areas, quasi-industrial area, and residential area were evaluated. The results were as follows: (1) The locations with the highest indoor and outdoor concentrations of heavy metals were the industrial areas followed by the heavy traffic area, residential area, and quasi-industrial area in a descending order of magnitude. Plus, the indoor heavy metal concentrations were higher then the outdoor ones. (2) The main heavy metal components were Zn, Al and Ca. Higher concentration levels were found indoors than outdoors. The heavy metal concentrations were also higher in the classrooms than in the corridor or outdoors. (3) The total heavy metal concentrations in the studied areas were highly dependent on the weather elements. including the relative humidity, mixing ratio, and wet-bulb depression. Accordingly, special ventilation systems are recommended to reduce air pollution in school environments.

Development of Time-location Weighted Spatial Measures Using Global Positioning System Data

  • Han, Daikwon;Lee, Kiyoung;Kim, Jongyun;Bennett, Deborah H.;Cassady, Diana;Hertz-Picciotto, Irva
    • Environmental Analysis Health and Toxicology
    • /
    • v.28
    • /
    • pp.5.1-5.7
    • /
    • 2013
  • Objectives Despite increasing availability of global positioning system (GPS), no research has been conducted to analyze GPS data for exposure opportunities associated with time at indoor and outdoor microenvironments. We developed location-based and time-weighted spatial measures that incorporate indoor and outdoor time-location data collected by GPS. Methods Time-location data were drawn from 38 female subjects in California who wore a GPS device for seven days. Ambient standard deviational ellipse was determined based on outdoor locations and time duration, while indoor time weighted standard deviational ellipse (SDE) was developed to incorporate indoor and outdoor times and locations data into the ellipse measure. Results Our findings indicated that there was considerable difference in the sizes of exposure potential measures when indoor time was taken into consideration, and that they were associated with day type (weekday/weekend) and employment status. Conclusions This study provides evidence that time-location weighted measure may provide better accuracy in assessing exposure opportunities at different microenvironments. The use of GPS likely improves the geographical details and accuracy of time-location data, and further development of such location-time weighted spatial measure is encouraged.

Outdoor Table Design Study of Applying the Structure of Soban (소반의 구조를 적용한 Outdoor Table 디자인 연구)

  • Go, Young-Lok;Kim, Chung Ho
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.4
    • /
    • pp.288-296
    • /
    • 2014
  • The approach of using the structure of the Joseon Dynasty Zen tradition we design a piece of table for outdoor camping is a necessity in modern culture as continuing to develop this research. Analyzing outdoor and camping equipment according to the time change, we focus on the study table for outdoor camping can apply the structure of the elbow. Outdoor supply is also overlaid with the change, while changing in the picnic and camping camp sensibility that was taking advantage of the individuality of each of the general camp. However, it is a surface camp that Korean culture is not to build up the camp culture that has been fixed camp culture of the world in the only development, following the camp trend of European and American. In an attempt to adhere to the trend of Korea currently camped, camping outdoor products that apply the beauty of Korea with a combination of new modern representation tradition and our culture has designed research. I have designed the camp outdoor table based on the contents mentioned above. For the design of this time, it is now possible to use appropriately in accordance with the outdoor environment conditions that are designed to upright seat sharing table in the market tables for camping and to be divided into the seat and upright.

  • PDF

Interpretive Approaches to the Characteristics of Neighborhood Environment Using Qualitative GIS of the Elderly's Outdoor Activities - Focused on the Musugol, a Low-Income Elderly Concentrated Area in Seoul - (노인층 옥외활동의 질적 GIS를 활용한 근린환경 특성의 해석 - 서울시 저소득 노인밀집지역 무수골을 대상으로 -)

  • Yun, Ye-Hwa;Sung, Jong-Sang
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.3
    • /
    • pp.1-18
    • /
    • 2022
  • Prior studies have shown positive effects of outdoor activities on the elderly's physical, mental and social health. 'Active aging' and 'age-friendly' neighborhood can be created by modifying the experiences and perceptions of the outdoor environment. This study aims to investigate the outdoor activities of the elderly living in a low-income elderly concentrated area and their perception of the neighborhood environment. We also explored the context of interactions between the facilitators and inhibitors of outdoor activities on the basis of temporal, spatial, and social conditions. We used a mixed method approach by collecting two different types of qualitative GIS data : observation maps of the main places and individual cognitive maps with in-depth interviews. The observational map analysis indicated that the preferred places and activity patterns differ by age, gender, and size of the group. The cognitive map and interviews demonstrated that the elderly's activity goals and perception of the landscape differ by places such as forests, parks, streams, open-spaces, vegetable gardens, and alleys. The elderly's desire for outdoor activities can be better fulfilled when their front doors and alleys are well-connected to an open-sight pleasant space. Familiarity is an important factor for the elderly, therefore it is important to remove the psychological and physical barriers by increasing the legibility and accessibility of places. In addition, social interactions and conflicts can have a significant influence on the elderly's occupation of space in the neighborhood environment.

Development and Application of Real-Time Monitoring System for Efficient Operation of Workplace in Plant Equipment Maker (플랜트 기자재 업체의 효율적인 작업장 운영을 위한 실시간 모니터링 시스템 개발 및 적용)

  • Jeong, A-Reum;Cho, Chi-Woon;Baek, Tae-Hyun
    • IE interfaces
    • /
    • v.25 no.1
    • /
    • pp.114-126
    • /
    • 2012
  • This study describes a real-time location monitoring system developed for efficient operation of workplace in plant equipment maker. This monitoring system can be applied for indoor and outdoor working environment respectively. By using the real-time tracking system based on RTLS, it is possible to track worker's movement and location of working object under indoor working environment. For outdoor working environment, the real-time monitoring system based on IDGPS is applied for work safety and balanced workload. A case study is provided to evaluate the performance of the real-time monitoring system.

A Study on the Ultraviolet Aging Characteristics of Outdoor Polymeric Insulating Materials (옥외용 고분자 절연재료의 자외선 열화특성 연구)

  • Kim, Yeong-Seong;Jeong, Sun-Ok
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.409-413
    • /
    • 1999
  • Recently, the polymeric insulators have been accepted in several countries for the outdoor high voltage applications. In comparison with the conventional porcelain, polymeric insulators offer various advantages such as light weight, superior vandal resistance and better contamination performance. The outdoor polymeric insulating materials such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged such as silicone rubber, ethylene propylene diene monomer(EPDM), ethylene vinyl acetate(EVA) and epoxy are aged under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-under the various natural environment with the long-term performance in outdoor. In this paper, the effects of UV-ray on the surface of silicone rubber were investigated by using the weather-Ometer. The accelerated aging stresses were simulated by UV radiation, high temperature and humidity as well as water spray. These aging characteristics were examined through contact angle measurements, tracking resistance test, FT-IR and SEM/EDS analysis. The experimental results showed that tracking resistance decreases with increase in the UV-ray irradiation period. But the surface of silicone rubber kept hydrophobicity. It is found that the inorganic filler such as)$ Al(OH_3$ improves tracking resistance and the $Tio_2$is very effective in preventing degradation of silicone rubber surface from UV-ray.

  • PDF

A Review of Scientific Evidence on Indoor Air of School Building: Pollutants, Sources, Health Effects and Management

  • Chithra, V.S;Shiva, Nagendra S.M
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.87-108
    • /
    • 2018
  • Schools are one of the critical social infrastructures in a society, the first place for social activity and the most important indoor environment for children besides the home. Poor IAQ in classrooms can increase the chance of long-term and short-term health problems for students and staffs; affects productivity of teachers; and degrade the student learning environment and comfort levels. The primary objective of this paper is to review and summarize available scientific evidence on indoor air quality of schools and related health effects in children. It was found that the indoor air pollutant levels in school buildings varied over a wide range in different parts of the world depending on site characteristics, climatic conditions, outdoor pollution levels, occupant activities, ventilation type and building practices. Among the indoor air pollutants, particulate matter concentrations were found to be very high in many schools. Outdoor pollutant sources also play a major role in affecting the IAQ of the school building. Hence, scientific knowledge on sources of indoor pollutants, quantification of emissions, temporal and spatial dispersion of pollutants, toxicological properties, chemical and morphological characteristics of the pollutants and associated health risk among children in the school buildings are essential to evaluate the adequacy and cost effectiveness of control strategies for mitigating the IAQ issues.

A Study on the Development of Design Guidelines for the Outdoor Play Settings in Child Care Center (아동보육시설의 실외놀이 환경 디자인지침 개발 연구)

  • Choi, Mock-Wha;Byun, Hea-Ryung
    • Korean Journal of Human Ecology
    • /
    • v.16 no.4
    • /
    • pp.855-875
    • /
    • 2007
  • The purpose of this study is to suggest a guideline for outdoor play settings in child care centers. From March to July, 2005, data were collected from 223 directors at child care centers through a structured questionnaire, field measurement survey and non-participatory observation in seventeen child care centers in Seoul and Daejeon. The statistical methods for analysing data were frequency, percentage, mean, $X^2$ and F-test. The results showed as follows: 1)the existing outdoor playground area in child care centers should be expanded more than $4\;m^2$ per child. 2) Outdoor play facilities should be equipped with two structured play sets, a play facility for unstructured play and an adventure facility to make child's various activities possible and to promote child development. 3)flooring materials for outdoor playground should be required to use more than three kinds such as solid coverings (cf. asphalt, standard concrete), wood, lawn, soil or sands. 4)to let children enjoy various activities, outdoor playground area should be composed of various play facilities like indoor play gyms and should be independent but have good connections between play facilities depending on characteristics of play activities. 5)Play spaces of outdoor playground should be composed of physical play space, unstructured and dramatized play space, rest space, space for nature and adventure space. In addition, appropriate play equipments should be provided in respective play space.

Indoor PM2.5 Concentrations in Different Sizes of Pubs with Non-comprehensive Smoke-free Regulation (비 포괄적인 금연정책을 시행한 호프집의 면적에 따른 실내 PM2.5 농도)

  • Kim, Jeonghoon;Lim, Chaeyun;Lee, Daeyeop;Kim, Heyjin;Guak, Sooyoung;Lee, Na Eun;Kim, Sang Hwan;Ha, Kwon Chul;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.126-132
    • /
    • 2015
  • Objectives: The Korean government implemented a smoke-free regulation for pubs with a net indoor area of ${\geq}100m^2$ on January 1, 2014. The purpose of this study was to determine the indoor levels of concentrations of particulate matter smaller than $2.5{\mu}m$ ($PM_{2.5}$) in implemented and non-implemented pubs in Seoul and Changwon. Methods: $PM_{2.5}$ concentrations in fifty-two $100-150m^2$ (implemented) and fifty-seven < $100m^2$ (non-implemented) pubs were measured. A real-time aerosol monitor was used to measure $PM_{2.5}$ concentrations. Field technicians recorded characteristics of the pubs including net indoor area, indoor volume and presence of smoking rooms and counted the number of burning cigarettes, patrons and vents. Results: Differences between indoor and outdoor $PM_{2.5}$ concentrations in $100-150m^2$ and < $100m^2$ pubs were not significantly different in each city. Smoking was observed in 33% of $100-150m^2$ pubs and 51% of < $100m^2$ pubs. Average differences between indoor and outdoor $PM_{2.5}$ concentrations in the $100-150m^2$ and < $100m^2$ pubs were $79.2{\mu}g/m^3$ and $155.6{\mu}g/m^3$, respectively. When smokers were not observed, differences between indoor and outdoor $PM_{2.5}$ concentrations ware $12.4{\mu}g/m^3$ in $100-150m^2$ pubs and $24.5{\mu}g/m^3$ in < $100m^2$ pubs. Conclusion: Although the regulation was implemented only in ${\geq}100m^2$ pubs, a higher difference between indoor and outdoor $PM_{2.5}$ concentrations was observed in implemented and non-implemented pubs with smokers. Strict implementation of the regulation in all pubs is needed for better indoor air quality.