• Title/Summary/Keyword: Scanning width

Search Result 366, Processing Time 0.025 seconds

A Study on the Display Discharge Characteristics of PDP for the HDTV (HDIV를 위한 PDP의 표시방전특성에 관한 연구)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.39-46
    • /
    • 2005
  • This research concerns the ADS drive method of 3 electrodes AC PDP and is determined the minimum pulse width of the address and the sustain, which the steady sustain discharge without decreasing luminance can be obtained. From the experimental result, if the address pulse width became $1.5[{\mu}s]$ or more a effective address discharge with the operating margin of 35[V] was possible. And if the sustain pulses width became $2[{\mu}s]$ or more, a steady sustain discharge with the operation margin of 25[V] was possible. When this condition is applied to Full-HDTV class PDP with the in lines of horizontal scanning lines, 8 sub-fields and total 1420 sustain pulses can be used.

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.

Discharge Characteristics of Narrow Width Pulse Addressing for the High-Speed Driving of Plasma Display Panels (플라즈마 디스플레이 패널의 고속 구동을 위한 세폭 펄스 어드레스 방전특성)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.13-19
    • /
    • 2007
  • This study relates to a new high-speed drive method for the full-HD PDP with 1080 horizontal scanning lines. The characteristics of the new drive method is evaluated considering the characteristics of the display discharge by the high-speed addressing. In this drive method, if the width of the address pulse narrows, the relati0[V]e discharge strength and the discharge time lag of the first display discharge are received the influence of it. Though the change in the applied position of the address pulse is unrelated to the discharge strength, it influences at the discharge time lag. However, the stable display discharges can be induced regardless of the address pulse position and width if the address pulse position is within [$6{\mu}s$] and the width is up to [$0.7{\mu}s$]. From the experiments, it has been understood that the high-speed drive technique with the address pulse of narrow width is sensitively influenced by the space charge because of the insufficiency of wall charge.

Evaluating Measurements: A Comparative Study of Digital and Plaster Models for Orthodontic Applications in Mixed Dentition

  • Seo Young Shin;Yong Kwon Chae;Ko Eun Lee;Mi Sun Kim;Ok Hyung Nam;Hyo-seol Lee;Sung Chul Choi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.55-65
    • /
    • 2024
  • This study aimed to assess the accuracy of tooth widths, intermolar widths, and arch lengths acquired through two intraoral scanners, including iTero Element Plus Series (Align Technology, Santa Clara, CA, USA) and Trios 4 (3Shape, Copenhagen, Denmark), specifically on mixed dentition. A total of 30 subjects were divided into 2 groups, each undergoing both alginate impressions and intraoral scanning using either the iTero or Trios scanner. The plaster models were measured with a caliper, while the digital models were measured virtually. In the iTero group, all tooth width measurements exhibited differences compared to the plaster values, except for maxillary left lateral incisors (p = 0.179), mandibular right (p = 0.285), and left (p = 0.073) central incisors. The Trios group did not display significant differences in any of the tooth width measurements. Intermolar width comparisons for both groups indicated differences, except for mandibular primary canine to primary canine values (p = 0.426) in the iTero group. Regarding arch length, the mandibular anterior, maxillary right, and left arch lengths in the iTero group demonstrated larger caliper values than those of iTero. Conversely, in the Trios group, all parameters showed smaller caliper values, especially in upper anterior, maxillary right, mandibular right, and mandibular left arch lengths with significance (p = 0.027, 0.007, 0.003, and 0.047, respectively). Despite the differences between the two groups, digital models might be clinically suitable alternatives for plaster models. Pediatric dentists should carefully assess these differences, as a comprehensive evaluation would result in precise orthodontic treatment planning and favorable outcomes for young patients with mixed dentition.

A Study On The Text Recognition Using Artificial Intelligence Technique (인공지능 기법을 이용한 텍스트 인식에 관한 연구)

  • 이행세;최태영;김영길;김정우
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.11
    • /
    • pp.1782-1793
    • /
    • 1989
  • Stroke crossing number, syntactic pattern recognition procedure, top down recognition structure, and heuristic approach are studied for the Korean text recognition. We propose new algorithms: 1)Korean vowel seperation using limited scanning method in the Korean characters, 2) extracting strokes using stroke width method, 3) stroke crossing number and its properties, 4) average, standard deviation, and mode of stroke crossing number, and 5) classification and recognition methods of limited chinese character. These are studied with computer simuladtions and experiments.

  • PDF

Effect of Geometric Surface Structure on Frictional Behavior (표면의 기하학적 형상에 따른 마찰 특성)

  • 이형석;김대은
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.205-211
    • /
    • 2000
  • Friction control is highly desirable for optimization of tribological systems. In this work, the effect of geometric structure of the solid surface on friction is investigated using a Scanning Electron Microscope equipped with a tribotester. Silicon and silicon oxide specimens were used and undulations on the surface were fabricated by mechanical and chemical methods. It is shown that the friction coefficient depends on the relative dimensions of the ball and the width of undualation. By optimizing the geometry of the undulation, friction reduction may be achieved.

  • PDF

Creation of Three-dimensional Convergence Model for Artifact Based on Optical Surface Scanning and X-ray CT: Sam-Chongtong Hand Canon in Jinju National Museum (광학식 표면스캐닝 및 X-선 CT를 활용한 유물의 3차원 융합모델 제작: 국립진주박물관 소장 삼총통)

  • Jo, Younghoon;Kim, Dasol;Kim, Haesol;Huh, Ilkwon;Song, Mingyu
    • Conservation Science in Museum
    • /
    • v.22
    • /
    • pp.15-26
    • /
    • 2019
  • This study was focused on the three-dimensional convergence modeling that can multilaterally analyze internal and external shapes of the Sam-Chongtong Hand Canon by optical precision scanning optimized for acquiring the surface shape and X-ray CT scanning used for obtaining the internal shape. First, the scanning results were converted by compatible extension, after which three-dimensional deviation analysis was conducted to verify mutual conformities. Accordingly, most (56.98%) deviations between the two scanning models was found be ±0.1mm. This result did not influence registration and merging based on the ICP algorithm. The merged data exhibited the external surface color, detailed shapes, internal width, and structure of the hand canon. The three-dimensional model based on optical surface scanning and X-ray CT scanning can be used for traditional technique interpretation as well as digital documentation of cultural heritage. In the future, it will contribute to deliver accessible scientific information of exhibits for visitors.

A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE (호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구)

  • Cho, Su-Mi;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

Drafting Method of Upper Bodice Pattern using 3-D Anthropometric Data for Elderly Women (노년 여성 3-D 입체형상 데이터를 활용한 상반신 원형 설계방법 연구)

  • Suh, Chu-Yeon;Park, Soon-Jee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.5
    • /
    • pp.846-858
    • /
    • 2008
  • This study was designed to propose a method to draft bodice block pattern from 3D body scan data. Subjects were ten elderly women in their 60's, who wear basic size(B: 94cm, W: 82cm) garment. Scanning was done using 3D whole body scanner(WB4, Cyberware). Measurements for 3D data and cross section were attained using Auto CAD, by which a upper bodice pattern for elderly women was drawn on the basis of short measured method. The results are as following: As for most items, no significant differences were shown between measurements from Martin's anthropometry and those from 3D scan data, suggesting measurement from 3D scan data could be used to draft a pattern. The drafting equations acquired were as follows; width of pattern=B/2+5.5, width of waist=W/2+3.5cm, dart amount=8cm. Dart distributions were 23%(B.P.) : 20%(front armpit) : 17%(side seam) : 18%(back armpit) : 15%(back protruded point) : 7% (center back line). Through wearing test using 5-point Likert scale, resultant pattern was evaluated as appropriate for elderly women's pattern to get over 4 point. As a result, it might be said that 3D scanning application is effective for elderly women in that it doesn't take time so much as Martin's anthropometry and that their body shape vary compared with those of young women.

A Study on the Estimation of Fish School Abundance Using Sonar Image (소너 화상을 이용한 어군량 추정에 관한 연구)

  • 이유원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.2
    • /
    • pp.92-98
    • /
    • 2003
  • The quantification of fish school abundance was carried out by using luminance of pixel on scanning sonar image, and compared with the indices of fish school abundance e.g. school number, school area and weighted school area. The survey was carried out in Funka Bay off southern Hokkaido, Japan using research vessel Ushio-Maru during December 1999. A 180-degree scanning sonar with a frequency of 164kHz was used. The school number was counted both left and right 40-degree radial lines from the center of own vessel mark on a scanning image. The school area was measured approximately as an ellipse from the school length and width. The weighted school area was calculated by multiplying school area and average value of inner pixel luminance. A quantification of pixel luminance was also measured to integrate squared pixel luminance value on these lines. Fish school and school bottom were discriminated by the produced sonar echogram using pixel luminance value on these lines. The relationships between the quantified luminance value and other abundance indices such as school area and weighted school area revealed a good correlation. Therefore, the quantified luminance is a useful method in estimating fish school abundance in the acoustic survey using sonar.