• 제목/요약/키워드: Scanning system

검색결과 2,489건 처리시간 0.029초

중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구 (Comparison of Size between direct-measurement and 3D body scanning)

  • 차수정
    • 패션비즈니스
    • /
    • 제16권1호
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

갈바노 스캐너와 DMD(Digital Micro-mirror Device)를 이용한 두부 고정형 다초점 디스플레이 시스템 (Head Fixed Type Multi-Focus Display System Using Galvano-Scanner and DMD(Digital Micro-Mirror Device))

  • 김동욱;권용무;김성규
    • 한국통신학회논문지
    • /
    • 제34권10B호
    • /
    • pp.1117-1123
    • /
    • 2009
  • DMD(Digital Micro-mirror Device)와 갈바노 스캐너를 이용한 두부 고정형 다초점 디스플레이 시스템은 초점조절이 가능하여 스테레오스코픽 디스플레이에서 발생하는 양안의 수렴작용과 단안의 초점조절 작용의 불일치에 의한 눈의 피로 문제를 해결할 수 있는 디스플레이 시스템이다. 이 시스템은 레이저 스캐닝 방법으로 각 시점에 대한 영상의 수렴점을 형성하여 관찰자 동공에 제공함으로 초점조절이 가능토록 한다. 본 논문에서는 이 다초점 디스플레이 시스템의 레이저 스캐닝 방법을 수학적으로 분석하였고, 이러한 분석에 기반 한 다초점 시스템을 제작하여 비디오카메라를 통하여 초점조절이 가능함을 보였고, 결과적으로 레이저 스캐닝 방법에 의한 다초점 시스템의 시점 형성원리가 검증되었다.

주사전자현미경을 활용한 세라믹의 분석 (Analysis of Ceramics Using Scanning Electron Microscopy)

  • 이수정
    • 세라미스트
    • /
    • 제22권4호
    • /
    • pp.368-380
    • /
    • 2019
  • A ceramic is used as a key material in various fields. Accordingly, the use of scanning electron microscopy is increased for the purpose of evaluating the reliability and defects of advanced ceramic materials. The scanning electron microscope is developed to overcome the limitations of optical microscopy and uses accelerated electrons for imaging. Various signals such as SE, BSE and characteristic X-rays provide useful information about the surface microstructure of specimens and, the content and distribution of chemical components. The development of electron guns, such as FEG, and the improved lens system combined with the advanced in-lens detectors and STEM-in-SEM system have expanded the applications of SEM. Automated SEM-EDS analysis also greatly increases the amount of data, enabling more statistically reliable results. In addition, X-ray CT, XRF, and WDS, which are installed in scanning electron microscope, have transformed SEM a more versatile analytical equipment. The performance and specifications of the scanning electron microscope to evaluate ceramics were reviewed and the selection criteria for SEM analysis were described.

실시간 입자분포 측정을 위한 Radial Exhaust Multi-port System의 개발 및 성능평가 (Development and Performance Evaluation of Radial Exhaust Multi-port System for Real-time Particle Size Distribution Measurement)

  • 이홍규;이양우;전기수;안강호
    • 한국입자에어로졸학회지
    • /
    • 제9권3호
    • /
    • pp.133-137
    • /
    • 2013
  • Measuring particle size distribution is one of the primary concerns in aerosol studies. For a nano-particle size distribution measurement, many scientists use a combination of a differential mobility analyzer (DMA) and a condensation particle counter (CPC) system, which is a called scanning mobility particle sizer (SMPS). Although it has a very high particle size resolution, some issues still remain. These problems include residence time between a DMA and a CPC, discontinuity of a CPC, and disturbance due to long scanning time during the precise measurement of particles. In particular, long scanning time is not adequate for measuring particle size distribution since the particle concentration is changing during the measurement. In this study, we developed radial exhaust multi-port system (REM-system) with no scanning time and high resolution to measure real-time particle size distribution. As a result of the REM-system performed using mono-disperse particle, it is expected that this system will be suitable for measuring continuously changing aerosol. If the counting efficiency of multi-condensation particle counter (M-CPC) and data inversion matrix are completed, REM-system will be a very adequate system for unsteady aerosol, which changes for SMPS scanning time.

압전작동기를 이용한 레이져 스케닝 미러의 위치제어 (Position Control of Laser Scanning Mirror Using Piezoelectric Actuator)

  • 지학래;김재환;최승복
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.442-445
    • /
    • 1995
  • This paper presents the position tracking control of a laser scanning mirror system in which piezoelectic actuator is incorporated. Using the shear mode of the piezoelectric actuator,angular oscillation of a laser scanning mirror is derived. Torsion bar is rhen designed and attached to the piezoelctric actuator in order to magnify the amplitude generated by the actuator. Finite element modeling and analysis are essntial for designing the piezoelectic actuator. The torsional resonance mode of the piezoelectric actuator is found from the model analysis of the actuator and the mechanical shear is matched with the driving frequency. Transfer function between the electrical excitation and the mechanical shear deformation at resonance frequency is found form the response of the actuator calculated by the finite element analysis and the governing equation of the system is derived from d'Alembert's principle. Tracking control performance for desired trajectory which is, in fact, sinusoidal curve is presented in order to demonstrate the validity of the proposed system.

  • PDF

원통주사법을 이용한 저비용 근역장 시스템 설계 (Design of low-cost near-field system using circular cylindrical scanning)

  • 류홍균;송진우;임영훈;조용희
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2004년도 추계 종합학술대회 논문집
    • /
    • pp.280-284
    • /
    • 2004
  • 안테나의 특성 중 지향성(Directivity)과 관계있는 방사 패턴을 측정하기 위한 저가의 근역장 측정 시스템을 설계한다. 근역장 측정방법은 평면주사법에 기반을 둔 개선된 원통형 주사법 공식을 이용한다. 고가의 측정 장비인 네트워크 분석기를 대체하기 위한 방법을 제시하고 필요한 장치 규격을 제안한다.

  • PDF

Lynx Mobile Mapper를 이용한 레이저스캐너 기반 차량 MMS의 정확도 평가 (Accuracy Estimation of Laser scanning Mobile Mapping System using Lynx Mobile Mapper)

  • 정태준;윤홍식;황진상;김용현;위광재
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.69-71
    • /
    • 2010
  • In this paper, we focus on the accuracy estimation of laser scanning mobile mapping system using Lynx Mobile Mapper. For this, we surveyed checkpoints(181 points) in study areas. A method to estimate the accuracy of laser scanning mobile mapping system based on the measurement range, interval of control points and gps signal environments. As a result, to ensure reliable measurement results, we must be made a plan considering Measure range(60m or under) and operation. The estimation results showed the need for improving accuracy using control points about 150m interval according to environment error source.

  • PDF

면광원을 사용한 Scanning Backlight System의 설계 및 제작 (Design and Fabrication of Scanning Backlight System using Flat Fluorescent Lamp)

  • 채형준;허정욱;황선남;이준영;임성규
    • 반도체디스플레이기술학회지
    • /
    • 제7권2호
    • /
    • pp.29-33
    • /
    • 2008
  • LCD panels are increasingly used to show moving image material, for example in LCD television sets. However, moving images become blurred on LCD panels. One of the causes of motion blur is the slow reaction of LC(liquid crystal) cell to change in the pixel value. Another cause of motion blur is the hold-type characteristic of the LCD panel, during the frame time the image is shown continuously. This type of motion blur can be reduced with a scanning backlight. We have designed and fabricated a scanning backlight system that solves the hold-type characteristic problem in a way that Flat fluorescent lamp divided 6 blocks was scanned 60Hz.

  • PDF

저온 주사 레이저 및 홀소자 현미경을 이용한 YBCO 초전도 선재의 국소적 임계 온도 및 전류 밀도 분포 분석 (Distribution Analysis of the Local Critical Temperature and Current Density in YBCO Coated Conductors using Low-temperature Scanning Laser and Hall Probe Microscopy)

  • 박상국;조보람;박희연;이형철
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.28-33
    • /
    • 2011
  • Distribution of the local critical temperature and current density in YBCO coated conductors were analyzed using Low-temperature Scanning Laser and Hall Probe Microscopy (LTSLHPM). We prepared YBCO coated conductors of various bridge types to study the spatial distribution of the critical temperature and the current density in single and multi bridges. LTSLHPM system was modified for detailed linescan or two-dimensional scan both scanning laser and scanning Hall probe method simultaneously. We analyzed the local critical temperature of single and multi bridges from series of several linescans of scanning laser microscopy. We also investigated local current density and hysteresis curve of single bridge from experimental results of scanning Hall probe microscopy.

Airborne Infrared Scanning Imaging System with Rotating Drum for Fire Detection

  • Song, c;Chang, Jun;Cao, Jiao;Zhang, Lifei;Wen, Yao;Wei, Aman;Li, Jiang
    • Journal of the Optical Society of Korea
    • /
    • 제15권4호
    • /
    • pp.340-344
    • /
    • 2011
  • Airborne infrared techniques have been used in wild land fire management for decades. This paper describes a kind of infrared scanning system based on a rotating drum with a tilted porthole underside the plane nose. This design increases the stability of the mechanism system, reduces air resistance and protects inner parts. Aberration characteristics of a tilted ellipsoid porthole are analyzed and an effective solution is invented which makes the system achieve $30^{\circ}$ field of regard. The system's ultimate value of modulation transfer function is near the diffraction limit, which indicates that the performance of the rotating optical system meets the imaging requirements.