• Title/Summary/Keyword: Scanning range

Search Result 1,202, Processing Time 0.029 seconds

Poisson's Ratio Scanning Using Immersion Ultrasonic Testing

  • Oh, Seo-Young;Kim, Young-H.;Shin, Yo-Sub;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.519-523
    • /
    • 2008
  • Poisson's ratio is one of elastic constants of elastic solids. However, it has not attracted attention due to its narrow range and difficult measurement. Transverse wave velocity as well as longitudinal wave velocity should be measured for nondestructive measurement of Poisson's ratio. Hard couplant for transverse wave prevents transducer from scanning over specimen. In the present work, a novel measurement of Poisson's ratio distribution was proposed. Immersion method was employed for the scanning over the specimen. Echo signals of normal beam longitudinal wave were collected. Transverse wave modes generated by mode conversion were identified. From transit time of longitudinal and transverse waves, Poisson's ratio can be determined without information of specimen thickness. This technique was demonstrated for aluminum and steel specimens.

Kinetic Measurements on Elastomer by Differential Scanning Calorimetry (Differential Scanning Calorimetry에 의(依)한 탄성체(彈性體)의 속도론적(速度論的) 연구(硏究))

  • Choi, Sei-Young
    • Elastomers and Composites
    • /
    • v.22 no.4
    • /
    • pp.333-339
    • /
    • 1987
  • A modern kinetic evaluation method for nonisothermal reactions measured with Differential Scanning Calorimetry(DSC) is presented. It is based on multiple linear regression analysis using a number of curve points in a selectable range of conversion. The obtained kinetic data are the basis to compute a reaction process under any condition e.g. isothermal or adiabatic. The DSC measurements was performed on a Mettler TA3000 SYSTEM with the built in evaluation software. Mainly the following reactions are discussed: vulcanization of natural rubber compounds containing vulcanizing accelerators. The purpose of this work is to analyse the vulcanization kinetics of typical NR vulcanization systems using DSC. These systems were chosen because they are typically reactive elastomer and are commercially important.

  • PDF

Modeling and Calibration of a 3D Robot Laser Scanning System (3차원 로봇 레이저 스캐닝 시스템의 모델링과 캘리브레이션)

  • Lee Jong-Kwang;Yoon Ji Sup;Kang E-Sok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.1
    • /
    • pp.34-40
    • /
    • 2005
  • In this paper, we describe the modeling for the 3D robot laser scanning system consisting of a laser stripe projector, camera, and 5-DOF robot and propose its calibration method. Nonlinear radial distortion in the camera model is considered for improving the calibration accuracy. The 3D range data is calculated using the optical triangulation principle which uses the geometrical relationship between the camera and the laser stripe plane. For optimal estimation of the system model parameters, real-coded genetic algorithm is applied in the calibration process. Experimental results show that the constructed system is able to measure the 3D position within about 1mm error. The proposed scheme could be applied to the kinematically dissimilar robot system without losing the generality and has a potential for recognition for the unknown environment.

CFRP Laser Joining Computer Simulation in a Parallel Kinematic Machine (병렬가공기계용 CFRP의 레이저 용접특성 시뮬레이션)

  • Lee, Seung-Taek;Park, Seung-Gyu;Choi, Hae-Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.77-82
    • /
    • 2017
  • A computer simulation method is introduced to understand the joining phenomena of PC and CFRP by estimating the temperature of the weld zone. Following the prior or preliminary research, the power range was set between 3 watts and 7 watts, and the scanning speed was set at 500 mm/min and 1,000 mm/min, respectively. Based on the computer simulation, the temperature near the joining boundary was not sufficient at the scanning speed of 1,000 mm/min, regardless of the selected powers. However, the temperature increases above the melting temperature of the selected polymers at the scanning speed of 500 mm/min. The simulation results were compared with actual weld samples to validate its actual use.

Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

The feature of scanning path algorithm shown at natural visual search activities of space user (공간사용자의 본능적 시선탐색활동에 나타난 주사경로 알고리즘 특성)

  • Kim, Jong-Ha;Kim, Ju-Yeon
    • Science of Emotion and Sensibility
    • /
    • v.17 no.2
    • /
    • pp.111-122
    • /
    • 2014
  • This study has analyzed the scanning path algorithm shown at the process of exploring spatial information through an observation experiment with the object of lobby in subway station. In the estimation of observation time by section, the frequency of scanning type was found to increase as the observation time got longer, which makes it possible that the longer the observation lasts the more the observation interruptions occur. In addition, the observation slipped out of the range of imaging when any fatigue was caused from the observation or the more active exploration took place. Furthermore, when the trend line was employed for the examination of the changes to the scanning type by time section, "concentration" "diagonal or vertical" showed a sharp and a gentle increases along with the increase of time section respectively, while "circulation. combination, horizontal" showed a reduction. The observation data of the subjects observing a space include various visual information. The analysis of the scanning type found at "attention concentration" enabled to draw this significant conclusion. The features of increase and decrease of scanning types can be a fundamental data for understanding the scanning tendency by time.

The Evaluation of Accuracy for Airborne Laser Surveying via LiDAR System Calibration (시스템 초기화(Calibration)에 따른 항공레이저측량의 정확도 평가)

  • 이대희;위광재;김승용;김갑진;이재원
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.15-26
    • /
    • 2004
  • The calibration for systematic error in LiDAR is crucial for the accuracy of airborne laser scanning. The main error is the misalignment of platforms between INS(Inertial Navigation System) and Laser scanner For planimetrical calibration of LiDAR, the building is good feature which has great changes in height and continuous flat area in the top. The planimetry error(pitch, roll) is corrected by adjustment of height which is calculated from comparing ground control points(GCP) of building to laser scanning data. We can know scale correction of laser range by the comparison of LiDAR data and GCP is arranged at the end of scan angle where maximize the height error. The area for scale calibration have to be large flat and have almost same elevation. At 1000m for average flying height, The Accuracy of laser scanning data using LiDAR is within 110cm in height and ${\pm}$50cm in planmetry so we can use laser scanning data for generating 3D terrain surface, expecically digital surface model(DSM) which is difficult to measure by aerial photogrammetry in forest, coast, urban area of high buildings

  • PDF

A Examination on Stability of Dam using 3D Laser Scanning System (3D Laser Scanning을 이용한 댐체의 안정성 검토)

  • Lee, Jae-One;Shon, Ho-Woong;Yun, Bu-Yeol
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.451-454
    • /
    • 2007
  • There is an inseparable relation between human race and engineering work. As world developed into highly industrialized society, a diversity of large structures is being built up correspondently to limited topographical circumstance. Though large structures are national establishments which provide us with convenience of life, there are some disastrous possibilities which were never predicted such as ground subsidence and degradation. It is very difficult to analyze the volume of total metamorphosis with the relative displacement measurement system which is now used and it is impossible to know whether there is structural metamorphosis within a permissible range of design or not. In this research with an object of 13-year-old earthen dam, through generating point-cloud which has 3D spatial coordinates(x, y, z) of this dam by means of 3D Laser Scanning, we can get real configuration data of slanting surface of this dam with this method of getting a number of 3D spatial coordinates(x, y, z). It gives 3D spatial model to us and we can get various information of this dam such as the distance of slanting surface of dam, dimensions and cubic volume. It can be made full use of as important source material of reinforcement and maintenance works to detect previously the bulging of the dam through this research.

  • PDF

Development of Cross Section Management System in Tunnel using Terrestrial Laser Scanning Data (지상 레이저 스캐닝 자료를 이용한 터널단면관리시스템 개발)

  • Roh, Tae-Ho;Kim, Jin-Soo;Lee, Young-Do
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.1
    • /
    • pp.90-104
    • /
    • 2008
  • Laser scanning technology with high positional accuracy and high density will be widely applied to vast range of fields including geomatics. Especially, the development of laser scanning technology enabling long range information extraction is increasing its full use in civil engineering. This study taps into the strengths of a terrestrial laser scanning technique to develop a tunnel cross section management system that can be practically employed for determining the cross section of tunnels more promptly and accurately. Three dimensional data with high density were obtained in a prompt and accurate manner using a terrestrial laser scanner. Data processing was then conducted to promptly determine arbitrary cross sections at 0.1meter, 0.5meter and 1.0meter intervals. A laser scanning technique was also used to quickly and accurately calculate the overbreak and underbreak of both each cross section and the entire tunnel section. As the developed system utilizes vast amounts of data, it was possible to promptly determine the shape of arbitrary cross section and to calculate the overbreak and underbreak more accurately with higher area precision. It is expected, therefore, that the system will not only enable more efficient and cost effective tunnel drilling management and monitoring but also will provide a basis for future construction and management of tunnel cross section.

  • PDF

A Study on 3D Reconstruction of Urban Area

  • Park Y. M.;Kwon K. R.;Lee K. W.
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.470-473
    • /
    • 2005
  • This paper proposes a reconstruction method for the shape and color information of 3-dimensional buildings. The proposed method is range scanning by laser range finder and image coordinates' color information mapping to laser coordinate by a fixed CCD camera on laser range finder. And we make a 'Far-View' using high-resolution satellite image. The 'Far-View' is created that the height of building using DEM after contours of building extraction. The user select a region of 'Far View' and then, appear detailed 3D-reconstruction of building The outcomes apply to city plan, 3D-environment game and movie background etc.

  • PDF