• Title/Summary/Keyword: Scanning Image

Search Result 1,092, Processing Time 0.029 seconds

The Analysis of CT Number Rate of Change of Applying The Iterative Metallic Artifact Reduction Algorithm for CT Reconstruction Image (Iterative Metallic Artifact Reduction 알고리즘 적용 CT 재구성영상의 CT Number 변화율 분석)

  • Kim, Hyeonju;Yoon, Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.84-91
    • /
    • 2017
  • This study was performed using Somatom Definition Flash (Siemens, Enlarge, Germany) and GE 64-MDCT (Discovery 750 HD, GE HEALTHCARE, Milwaukee, USA.) using high-density medical materials that (are indispensable to?) computed tomography. We analyzed quantitatively the rate of change of the CT number of the CT reconstruction images by means of the IMAR and MAR algorithms using the phantom images acquired after scanning and previously captured raw data images. As a result, it was shown that the IMAR and MAR algorithms provided if ferent phantom images in the case of all medical high-density materials (p <0.05). The black streak artifacts were analyzed using the MAR and IMAR algorithms to determine if they corresponded to stainless steel materials (p>0.05). Also, it was found that the application of the IMAR algorithm affects the attenuation deviation, because there is a change in the image CT number compared to that before. The results suggest that, in the future, after the implant procedure, it would be useful to observe the surgical site and surrounding tissues during follow-up CT scans.

Study On The Signal Radar Plan Position Indicator Scope Of The Data Expressed Scanning System Implemented As An Sticking Image On LCD Display (Plan Position Indicator Scope 주사방식의 Radar 영상신호를 LCD Display에 잔상영상으로 데이터 표출 구현에 관한 연구)

  • Shin, Hyun Jong;Yu, Hyeung Keun
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.94-101
    • /
    • 2015
  • The display device is an important video information communication system device to connect between human and device. it transfers the information as characters, shapes, images and pattern to enable recognizing by eyes. Theres absolutely needs some key functions and role to quickly display informations. It can analyse a information through a PPI Scope of a cathode-ray tube(CRT) displays information which can perform a role. this research proposed a radar device to display informations as received signal. The radar display researches can apply to fixed function graphics pipeline algorithms of the large capacity type through a vertical blanking interval and buffer swap of display unit. Also, it can be possible to apply to performed algorithms to FPGA logic without high-performance graphics processing unit GPU through synchronization which can implement a display system. In this paper, we improved the affordability and reliability through proposed research. 이So, we have studied the radar display unit which can change a flat display from radar display of CRT radar display.

Preparation and Characteristic of Size Controlled Platy Silver by Polyol Process with $PdCl_2$ ($PdCl_2$ 첨가 폴리올공정(工程)을 이용(利用)한 판상 은(銀) 분말(粉末) 제조(製造) 및 특성(特性))

  • Shin, Gi-Wung;Ahn, Jong-Gwan;Kim, Dong-Jin;Cho, Sung-Wook;Ahn, Jea-Woo
    • Resources Recycling
    • /
    • v.19 no.5
    • /
    • pp.58-67
    • /
    • 2010
  • Platy silver powders with varied size and thickness were prepared by polyol process with $PdCl_2$ in ethylene glycol and characterized its properties and investigated the effects of reaction time, $NH_4OH$, PVP(poly-vinylpyrrolidone) and $PdCl_2$. The characteristics of the products were verified by scanning electron microscopy(SEM), high resolution transmitted electron microscopy(HR-TEM), X-ray diffraction(XRD) and particle size analyzer(PSA) and image analyzer. Platy silver powder was prepared about $5.5\;{\mu}m$ of size and $0.2\;{\mu}m$ at 120minute. It was found that the size of powders increased by the increasing of $NH_4OH$ and $PdCl_2$ concentrations, and the thickness of powders was decreased by increasing of PVP concentration.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN

  • Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.599-610
    • /
    • 2001
  • Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.

  • PDF

Growth of GaAs/AlGaAs structure for photoelectric cathode (광전음극 소자용 GaAs/AlGaAs 구조의 LPE 성장)

  • Bae, Sung Geun;Jeon, Injun;Kim, Kyoung Hwa
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.6
    • /
    • pp.282-288
    • /
    • 2017
  • In this paper, GaAs/AlGaAs multi-layer structure was grown by liquid phase epitaxy with graphite sliding boat, which can be used as a device structure of a photocathode image sensor. The multi-layer structure was grown on an n-type GaAs substrate in the sequence as follows: GaAs buffer layer, Zn-doped p-type AlGaAs layer as etching stop layer, Zn-doped p-type GaAs layer, and Zn-doped p-type AlGaAs layer. The Characteristics of GaAs/AlGaAs structures were analyzed by using scanning electron microscope (SEM), secondary ion mass spectrometer (SIMS) and hall measurement. The SEM images shows that the p-AlGaAs/p-GaAs/p-AlGaAs multi-layer structure was grown with a mirror-like surface on a whole ($1.25mm{\times}25mm$) substrate. The Al composition in the AlGaAs layer was approximately 80 %. Also, it was confirmed that the free carrier concentration in the p-GaAs layer can be adjusted to the range of $8{\times}10^{18}/cm^2$ by hall measurement. In the result, it is expected that the p-AlGaAs/p-GaAs/p-AlGaAs multi-layer structure grown by the LPE can be used as a device structure of a photoelectric cathode image sensor.

Numerical Analysis of Debris Flow Using Drone Images and NFLOW (드론 영상 및 NFLOW를 활용한 토석류 수치해석 연구)

  • Lee, Seungjoo;Lim, Hyuntaek;Lim, Moojae;Lee, Eungbeom;Lee, Kang-Il;Kim, Yongseong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.3
    • /
    • pp.1-8
    • /
    • 2020
  • In this study, numerical analysis of debris flow was performed using the SPH (Smoothed Particle Hydrodynamics) technique to analyze the mechanism of debris flow, and the applicability of soil parameters was verified by comparison with previous studies. In addition, after performing aerial photographic survey using a drone, a topographic model was created based on this survey to check the applicability of the site to the valley part of Jagul Mountain basin. And after numerical analysis of debris flow was performed using NFLOW, and the result was compared and analyzed with the existing satellite image based method. As a result of this study, the numerical analysis method using drone image and NFLOW was found to have a higher applicability to predicting the impact of debris flow, because it can reflect the actual topography better than the existing method based on satellite imagery. Therefore, it is considered that this study can be used as basic data to establish the preventive measures for debris flow such as location selection of the eruption control dam.

Comparison of Hounsfield Units by Changing in Size of Physical Area and Setting Size o f Region o f Interest b y Using the CT Phantom Made with a 3D Printer (3D 프린터로 제작된 CT 팬톰을 이용한 물리적 관심영역과 설정 관심영역의 크기에 따른 하운스필드의 비교)

  • Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.421-427
    • /
    • 2015
  • In this study, we have observed the change of the Hounsfield (HU) in the alteration of by changing in size of physical area and setting size of region of interest (ROI) at focus on kVp and mAs. Four-channel multi-detector computed tomography was used to get transverse axial scanning images and HU. Three dimensional printer which is type of fused deposition modeling (FDM) was used to produce the Phantom. The structure of the phantom was designed to be a type of cylinder that contains 33 mm, 24 mm, 19 mm, 16 mm, 9 mm size of circle holes that are symmetrically located. It was charged with mixing iodine contrast agent and distilled water in the holes. The images were gained with changing by 90 kVp, 120 kVp, 140 kVp and 50 mAs, 100 mAs, 150 mAs, respectively. The 'image J' was used to get the HU measurement of gained images of ROI. As a result, it was confirmed that kVp affects to HU more than mAs. And it is suggested that the smaller size of physical area, the more decreasing HU even in material of a uniform density and the smaller setting size of ROI, the more increasing HU. Therefore, it is reason that to set maximum ROI within 5 HU is the best way to minimize in the alteration of by changing in size of physical area and setting size of region of interest.

Evaluated the L-spine Magnetic Resonance Imaging for the Scanning Method of the Lateral Recumbent Position with to the Embarrassed Control of the Acute Low Back Pain (자기공명검사에서 통증제어가 불가능한 급성 요통 환자의 옆으로 누운 자세에 대한 영상평가)

  • Lee, Jaeheun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.255-260
    • /
    • 2014
  • The acute lumbar pain patients who were unavoidable to take MRI examination were made to take altered lateral recumbent position. they were also not able to control their painfulness and to be in supine position. In this study, it is supposed to increase success rate of the MRI examination through taking the altered lateral recumbent position in using spine and body matrix coil. This altered position made relaxing lumber pain and fatigue for the patients who suffered from sever lumber pain. In these reasons, it decreases the motion artifacts through correcting uncomfortable posture. As a result, qualitative analysis for the image quality was estimated to have average points of supine position A group(lateral recumbent position) of normal candidates and B group(lateral recumbent position) of the abnormal candidates who have sever pain at 4.64, 3.44, and 3.40, respectively. In conclusion, while qualitative analysis in the examination with supine position of the normal patients had significantly high points, the qualitative analysis in the examination with lateral recumbent position of the normal patients and abnormal patients who had sever lumbar pain was almost same. In addition, it was judged that radiologists' imagery interpretation had no other problems in the image evaluation of B group who had acute lumbar pain of abnormal patients. Hereupon, if this technique becomes generalized for the patients who suffer from supine position in the examination, it is supposed to be useful in medical field.

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.