Effect of Saline Flush on the Enhancement of Vascular and Liver via Saphenous Vein for Abdominal CT in Dogs

  • Kim, Song Yeon;Hwang, Tae Sung;An, Soyon;Hwang, Gunha;Go, Woohyun;Lee, Jong Bong;Lee, Hee Chun
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.135-142
    • /
    • 2021
  • The aim of this study was to evaluate the contrast effect if a saline flush following low-volume contrast medium bolus improves vascular and parenchymal enhancement using a saphenous vein in abdominal CT for small animals. Six clinically healthy beagle dogs underwent abdominal contrast-enhanced CT. They were divided into nine groups (each group, n = 6), according to the volume of contrast medium 1, 2, and 3 mL/kg, and volume of the saline solution 0, 5, and 10 mL. Dynamic CT scanning was performed at the hepatic hilum level. The maximum contrast enhancement, time to maximum enhancement, and time to equilibrium phase were calculated from the time attenuation curves. Mean attenuation values for all groups were measured in the aorta, portal vein, and liver. After contrast enhancement, grading of image quality regarding surrounding artifacts and evaluation of the hepatic hilum structures was performed. For comparison of the effect of the contrast material and saline solution doses, differences in mean attenuation values between the contrast medium 2 mL/kg without saline flush group and the remaining groups, and between contrast medium 3 mL/kg without saline flush group and the remaining groups, were analyzed for statistical significance. There were no significant differences between with and without saline flushing at the same contrast medium dose groups. There were no significant differences in peak values between the 3 mL/kg dose of contrast medium alone and the 2 mL/kg dose of contrast medium with saline solution flush. However, there was a significant difference in peak values between the 3 mL/kg dose of the contrast medium without the saline flush group and the 2 mL/kg dose of the contrast medium alone group. Grades of the artifacts were not significantly different in the saline flush regardless of the dose of the contrast medium. Using 2 mL/kg of contrast medium with saline solution flush resulted in similar liver parenchyma attenuation, compared with using 3 mL/kg of contrast medium without saline solution flush. In CT evaluation of hepatic parenchymal diseases, using 2 mL/kg of contrast medium with saline solution flush may yield decreased risk of contrast nephropathy and cost-saving.

A Study on Inhibition of Bacterial Membrane Formation in Biofilm formed by Acne Bacteria in Valine through Property Analysis (물성 분석을 통한 Valine 의 여드름균 바이오필름 내부 세균막 형성 억제 연구)

  • Song, Sang-Hun;Hwang, Byung Woo;Son, Seongkil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.2
    • /
    • pp.163-170
    • /
    • 2021
  • This study was conducted to create a technology to remove acne bacteria with human-friendly materials. First, the Cutibacterium acnes (C. acnes) were adsorbed to the mica disc to grow, and then the biofilm was checked through an atomic microscope to see if the biofilm had grown. Based on the topographic image, the shape changed round, the size was 17% longer on average, and the phase value of the resonance frequency separating materials was observed as a single value, the biofilm grown by covering the extracellular polymeric substrate (EPS). As a result of processing 50 mM of amino acids in the matured biofilm, the concentration of C. acnes decreased when valine, serine, arginine and leucine were treated. Scanning with nanoindentation and AFM contact modes confirmed that the hardness of biofilms treated with Valine (Val) increased. This indicates that an AFM tip measured cell which may have more solidity than that of EPS. The experiment of fluorescent tagged to EPS displays an existence of EPS at the condition of 10 mM Val, but an inhibition of growth of EPS at the 50 mM Val. Number of C. acnes was also reduced above 10 mM of Val. Weak adhesion of biofilm generated from an inhibition of EPS formation seems to induce decrease of C. acnes. Accordingly, we elucidated that Val has an efficiency which eliminates C. acnes by approach of an inhibition of EPS.

Effect of Aluminum Chloride Hemostatic Agent on Bonding Strength of RMGIC in Primary Tooth (염화알루미늄 지혈제가 유치와 레진강화형 글라스아이오노머 시멘트의 결합강도에 미치는 영향)

  • Woo, Seung-Hee;Shin, Jisun;Lee, Joonhaeng;Han, Miran;Kim, Jong Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.397-404
    • /
    • 2021
  • The purpose of this study was to evaluate the effect of a hemostatic agent containing aluminum chloride on the shear bond strength of resin-modified glass ionomer cement (RMGIC) to the dentin of primary teeth. Thirty-six extracted non-carious human primary teeth were collected in this study. Dentin surfaces were cut and polished. The specimens were randomly divided into 4 groups; group I: RMGIC without conditioning; group II: polyacrylic acid (PAA), RMGIC; group III: aluminum chloride, RMGIC; group IV: aluminum chloride, PAA, RMGIC. All teeth were thermocycled between 5.0℃ and 55.0℃ for 5000 cycles. Fifteen specimens from each group were subjected to shear bond strength test and 3 specimens from each group were inspected using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy. The mean shear bond strength of each group was as follows: 4.04 ± 0.88 MPa in group I, 8.29 ± 1.40 MPa in group II, 1.39 ± 0.47 MPa in group III, 6.24 ± 2.76 MPa in group IV. There were significant differences among all groups (p < 0.001). SEM image of the dentinal tubules were partially exposed in group III and group IV. Fully exposed dentinal tubules were found in group II. In conclusion, aluminum chloride decreased the shear bond strength of RMGIC to dentin, regardless of PAA conditioning.

The Effect of the Mixing Order on PVA Fiber-Reinforced Cementitious Composites with CNTs (CNT 혼입 PVA 섬유보강 시멘트 복합체에서의 배합 순서에 따른 영향)

  • Seong-Hyun Park;Dongmin Lee;Seong-Cheol Lee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.2
    • /
    • pp.130-137
    • /
    • 2023
  • This study analyzed the effect of mixing order on the flowability, compressive strength, and flexural strength of cement composites reinforced with polyvinyl alcohol(PVA) fibers and multi-walled carbon nanotubes(MWCNTs). The experimental results showed that the addition of CNTs significantly reduced the flowability, and the flowability was considerably affected by the mixing order when CNTs were added. The compressive strength was most effectively improved when water and CNTs solution were mixed first before adding PVA fibers, and the flexural strength was highest when water and CNTs solution were mixed with PVA fibers after dry mixing. However, there was no clear correlation between the flexural toughness and the mixing order. In addition, scanning electron microscopy(SEM) image analysis was conducted to analyze the microstructure. The SEM images showed that CNTs were randomly dispersed through the specimens and contributed to the strength improvement, but the effect of the mixing order was not clearly observed. The main results of this study are expected to be useful for evaluations of workability and material performance of PVA fiber-reinforced cement composites with CNTs.

A STUDY ON THE SHEAR BOND STRENGTH AND THE ANTICARIOGENICITY OF GLASS IONOMER CEMENT FOR BRACKET BONDING (브라켓 접착용 글라스 아이어노머 시멘트의 접착강도 및 항우식 효과에 관한 연구)

  • Kang, Yong-Joo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.538-553
    • /
    • 1999
  • The purpose of this study was to compare the shear bond strength and the anticariogenicity of glass ionomer cement with conventional bonding resin and fluoride releasing resin. After the shear bond strength test, scanning electron microscopic observation was performed for the evaluation of the fracture patterns in each group. Under the polarizing light microscope, artificially induced carious lesions were evaluated and the lesion depths of the samples were measured using image analyzing program(Image-Pro $PLUS^{TM}$, USA). 50 sound maxillary premolars were used for the bond strength test and another 30 for the anticariogenic test. Data collected were analyzed statistically using Oneway-ANOVA and Scheffe test. The results were as follows: 1. Glass ionomer groups(G-III, IV, V) generally showed the lower bond strength values than resin groups(G-I, II). 2. Among the two resin groups, G-I showed the higher bond strength than G-II without statistically significant difference between them(p>.05). 3. Within glass ionomer groups, statistical significance was found between G-III and G-V with the superior bond strength in G-V (p<.05). 4. Under the SEM, adhesive failure was the predominant fracture pattern in G-I and II, whereas cohesive failures were mainly observed in G-III. In G-IV and V, mixed type of pattern where the both fracture patterns coexisted within samples could be seen. 5. In evaluation of the depth of artificially developed carious lesion, glass ionomer group showed shallower depth than resin groups with statistical significance between G-III and G-I, II(p<.05). Among resin groups, fluoride releasing resin(G-II) showed the shallower depth than conventional resin(G-I)(p<.05).

  • PDF

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Microstructural Study of Mortar Bar on Akali-Silica Reaction by Means of SEM and EPMA Analysis (알칼리-실리카 반응에 의한 모르타르 봉의 SEM과 EPMA 분석을 통한 미세구조 연구)

  • Jun, Ssang-Sun;Lee, Hyo-Min;Jin, Chi-Sub
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.531-537
    • /
    • 2009
  • In this study alkali reactivity of crushed stone was conducted according to the ASTM C 227 that is traditional mortar bar test, and C 1260 that is accelerated mortar bar test method. The morphology and chemical composition of products formed in mortar bar, 3 years after the mortar bar tests had been performed, were examined using scanning electron microscopy (SEM) with secondary electron imaging (SEI) and electron probe microanalysis (EPMA) with backscattered electron imaging (BSEI). The crushed stone used in this study was not identified as being reactive by ASTM C 227. However, mortar bars exceeded the limit for deleterious expansion in accelerated mortar bar test used KOH solution. The result of SEM (SEI) analysis, after the ASTM C 227 mortar bar test, confirmed that there were no reactive products and evidence of reaction between aggregate particles and cement paste. However, mortar bars exposed to alkali solution (KOH) indicated that crystallized products having rosette morphology were observed in the interior wall of pores. EPMA results of mortar bar by ASTM C 227 indicated that white dots were observed on the surface of particles and these products were identified as Al-ASR gels. It can be considered that the mortar bar by ASTM C 227 started to appear sign of alkali-silica reaction in normal condition. EPMA results of the mortar bar by ASTM C 1260 showed the gel accumulated in the pores and diffused in to the cement matrix through cracks, and gel in the pores were found to be richer in calcium compared to gel in cracks within aggregate particles. In this experimental study, damages to mortar bars due to alkali-silica reaction (ASR) were observed. Due to the increasing needs of crushed stones, it is considered that specifications and guidelines to prevent ASR in new concrete should be developed.

Evaluation of Dose and Position Compensation of Parotid Gland Using CT On-rail System in Head-and-Neck Cancer (두경부 암환자 치료 시 CT On-rail System을 이용한 이하선의 위치 보정 및 선량 평가)

  • Jang, Hyeong-Jun;Im, Chung-Geun;Chun, Geum-Sung;Jeong, Il-Seon;Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Purpose: The checking method of target and normal structure are used by MVCBCT, KVCBCT, CT On-rail System, Ultrasound in H&N cancer patient. In case of MVCT, the utilization of bone structure is valuable to check around tissue. But the utilization of soft tissue is not enough. The point of this paper is dose variation in movable parotid and changeable volume of H&N cancer patient of CT On-rail System. Materials and Methods: The object of H&N cancer patient is 5 in this hospital. The selected patient are scanned ARTISTE CT Vision (CT On-ral System) a triweekly. After CT scanning, tranfered coordinates are obtained by movable of parotid gland comparison with planning image. Checking for the changeable volume of parotid gland. A Obtained CT image are tranfered to the RTP System. So dose variation are checked by following changed volume. Results: The changes of target coordinate by the parotid gland movement are X: -0.4~0.4 cm, Y: -0.4~0.3 cm, Z: -0.3~0.3 cm. the volume of GTV is decreased to about 7.11%/week and then both parotid gland volume are shrinked about 4.81%/week (Lt), 2.91%/week (Rt). At the same time, each parotid gland are diminished in radiation dose as 3.66%/week (Lt), 2.01%/week. Conclusion: Images from CT on the rail System which are able to aquire the better quality images of soft tissue in Target area than MVCBCT. After replanning and dose redistribution by required images, It could gain not only the correction of the patient set-tup errors but exact dose distribution. Accordingly, the delivery of compensated dose, It makes that we could do Adaptive Targeting Radiotherapy and need Real Time Adaptive Targeting Radiotherapy by reduce beam delivary time.

  • PDF