• Title/Summary/Keyword: Scanning Confocal Microscope

Search Result 198, Processing Time 0.028 seconds

Effect of NaCl on Biofilm Formation of the Isolate from Staphylococcus aureus Outbreak Linked to Ham

  • Lee, Soomin;Choi, Kyoung-Hee;Yoon, Yohan
    • Food Science of Animal Resources
    • /
    • v.34 no.2
    • /
    • pp.257-261
    • /
    • 2014
  • The objective of this study was to evaluate the effects of NaCl on the biofilm formations of the isolate from Staphylococcus aureus outbreaks linked to ham. The S. aureus ATCC13565 isolated from ham was exposed to NaCl concentrations of 0%, 2%, 4%, and 6% supplemented in tryptic soy broth (TSB) for 24 h at $35^{\circ}C$, followed by plating 0.1 mL of the culture on tryptic soy agar containing 0%, 2%, 4%, and 6% NaCl, respectively. After incubating at $35^{\circ}C$ for 24 h, the colonies on the plates were collected and diluted to $OD_{600}$ = 0.1. The diluents of S. aureus were incubated on a 96-well flat bottom plate containing TSB plus the appropriate NaCl concentrations, and the biofilm formation was quantified by crystal violet staining after being incubated at $35^{\circ}C$ for 9 h. Confocal laser scanning microscope (CLSM) was also used for visualizing the biofilm formation of S. aureus at NaCl concentrations of 0%, 2%, 4%, and 6%. The transcriptional analysis of biofilm-related genes, such as icaA, atl, clfA, fnbA, sarA, and rbf, was conducted by quantitative real-time PCR. Crystal violet staining and CLSM showed that the biofilm formations of S. aureus increased (p<0.05) along with the NaCl concentrations. Moreover, the expression of the icaA genes was higher at the NaCl concentrations of 4% and 6% as compared with 0% of NaCl by approximately 9-folds and 20-folds, respectively. These results indicated that the NaCl formulated in processed food may increase the biofilm formations of S. aureus by increasing the icaA gene expressions.

The Influence of Microinjection of Foreign Gene into the Pronucleus of Fertilized Egg on the Preimplantation Development, Cell Number and Diameter of Rabbit Embryos

  • Makarevich, A.V.;Chrenek, P.;Fl’ak, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.2
    • /
    • pp.171-175
    • /
    • 2006
  • The aim of this in vitro study was to test the effect of microinjection (Mi) of foreign gene into the rabbit egg pronucleus and epidermal growth factor (EGF) addition on the blastocyst rate, the cell number and the diameter of embryos, and to determine possible relationships between embryo cell number and embryo diameter. Blastocyst rate was significantly decreased in gene- Mi (G-Mi/E0) group (63.1%) comparing to intact ones (83.5%, $p_1$<0.05). The addition of EGF at 20ng/ml (G-Mi/E20) or 200 ng/ml (GMi/ E200) to gene-Mi embryos did not affect blastocyst rate (65.6 and 55.2% resp.). As a control for Mi, the eggs were microinjected with the same volume of phosphate-buffered solution (PBS-Mi) instead of the gene construct solution. Cell numbers and embryo diameters were measured from embryo images obtained on confocal laser scanning microscope. Bonferroni-modified LSD test showed that the embryo cell number in PBS-Mi group was significantly lower ($p_1$<0.05) and in gene-Mi group was tended to decrease compared with intact embryos. Embryo diameter was not different among experimental groups. No effect of EGF given at any doses both on the cell number and embryo diameter was found. A positive correlation between cell number and embryo diameter was observed in all groups of embryos. Since embryo diameter was not changed under the influence of Mi or EGF addition in this study, this seems to be more conservative characteristics of the embryo morphology. These results suggest that the pronuclear microinjection compromises developmental potential of embryos, decreasing blastocyst rate and embryo cell number, whilst embryo diameter is not affected. No effects of EGF on studied parameters were confirmed. Declined quality of Mi-derived embryos is caused by the microinjection procedure itself, rather than by the gene construct used.

CLSM Analysis of Change in Roughness and Physical Properties of Granite after Freeze-Thaw Experiments (CLSM을 이용한 동결/융해 실험 후 화강암 시료의 표면 및 물성변화 분석)

  • Jeong, Jongtaek;Choi, Junghae;Chae, Byung-Gon;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.271-281
    • /
    • 2013
  • Freeze-thaw experiments were conducted to evaluate changes in surface roughness and physical properties in samples of granite from Ilgwang and Imki mines, Korea. The temperature range in the experiments was $-20^{\circ}C$ to $40^{\circ}C$, based on typical summer and winter temperatures in Korea, and the surface was observed every 20 cycles. One cycle comprised 1 hour of heating or cooling of the samples and 1 hour during which the target temperature was maintained. With increasing repetitions of the freeze-thaw experiment, porosity increased by 0.05%-0.15% in the two samples and the dry weight increased, whereas the volume of the soil and saturation weight decreased. Observations by confocal laser scanning microscope (CLSM) revealed that line and surface roughness parameters showed a tendency to increase and decrease, respectively, with elapsed time. Changes in surface roughness were apparent on the CLSM images.

In Situ Observation of Solidification Behavior in Undercooled $Pd_{40}Cu_{30}Ni_{10}P_{20}$ Alloy Melts during Linear Cooling (연속냉각 중 과냉 된 $Pd_{40}Cu_{30}Ni_{10}P_{20}$ 합금 용탕의 실시간 응고거동 관찰)

  • Kim, Ji-Hun
    • Journal of Korea Foundry Society
    • /
    • v.23 no.5
    • /
    • pp.276-285
    • /
    • 2003
  • In the undercooled melt of $Pd_{40}Cu_{30}Ni_{10}P_{20}$ alloy, the solidification behavior including nucleation and growth of crystals at the micrometer level has been observed in-situ by use of a confocal scanning laser microscope combined with an infrared image furnace. The $Pd_{40}Cu_{30}Ni_{10}P_{20}$ alloy specimens were cooled from the liquid state to glass transition temperature. 575 K, at various cooling late under a helium gas flow. According to the cooling rate, the morphologies of the solidification front are changed among various types, irregular jog like front, columnar dendritic front, cellular grain, star like shape jog and fine grain, etc. The velocities of the solid-liquid interface are measured to be $10^{-5}{\sim}10^{-8}$ m/s which are at least two orders higher than the theoretical crystal growth rates. Combining the morphologies observed in terms of cooling rates and their solidification behaviors, we conclude that phase separation takes place in the undercooled molten $Pd_{40}Cu_{30}Ni_{10}P_{20}$ alloy. The continuous cooling transformation (CCT) diagram was constructed from solidification onset time at various linear cooling conditions with different rate. The CCT diagram suggests that the critical cooling rate for glassy solidification is about 1.5 K/s, which is in agreement with the previous calorimetric findings.

Changes in pre-osteoblast cells associated with non-precious metal cores with dental implants: Pilot test (치과용 임플란트 적용 비귀금속 코어와 관련된 전조골세포의 변화)

  • Park, Jung-Hyun;Kang, Seen-Young;Kim, Jong-Woo;Kim, Jang-Ju;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.40 no.2
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the non-precious metal core materials used in the dental laboratory to fabricate the implant superstructure by CAD / CAM method. And to observe and compare the morphology and distribution of the osteoblasts in relation to implant osseointegration. Methods: In this study, the mandibular right first molar tooth model was selected as an international standard to produce a single core. Using this model, the impression was made with the silicone rubber, the tooth model was scanned, and a single core was designed and 5-axis milling was performed. The materials used were Cobalt-Chromium and Nickel-Chromium, and the cores for dental implant top structures were fabricated according to the procedures of the dental labs. After the fabrication, the marginal area of the core was separated and cell culture experiment was performed. The osteoblast cells used MC3T3-E1, which is currently widely used. For morphological analysis of osteoblasts, cells were posttreated and observed using CLSM (Confocal Laser Scanning Microscope) and compared. Results: The cell adhesion behavior of the specimen surface measured by CLSM was uniformly distributed in specimen A (Cobalt-Chromium) than in specimen B (Nickel-Chromium). The distribution and changes of the cells were different in the two specimens. Conclusion : It is possible to confirm that specimen A (Cobalt-Chromium) is suitable for the living body through adhesion and proliferation of osteoblasts related to implant osseointegration in the non-precious metal superstructure used after implantation. It is considered that it is preferable to use Co-Cr when fabricating the superstructure.

SURFACE ANALYSES OF TITANIUM SUBSTRATE MODIFIED BY ANODIZATION AND NANOSCALE Ca-P DEPOSITION

  • Lee, Joung-Min;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.795-804
    • /
    • 2007
  • Statement of problem. Nano-scale calcium-phosphate coating on the anodizing titanium surface using ion beam-assisted deposition (IBAD) has been recently introduced to improve the early osseointegration. However, not much is known about their surface characteristics that have influence on tissue-implant interaction. Purpose. This study was aimed to investigate microtopography, surface roughness, surface composition, and wettability of the titanium surface modified by the anodic oxidation and calcium phosphate coating using IBAD. Material and methods. Commercially pure titanium disks were used as substrates. The experiment was composed of four groups. Group MA surfaces represented machined surface. Group AN was anodized surface. Group CaP/AN was anodic oxidized and calcium phosphate coated surfaces. Group SLA surfaces were sandblasted and acid etched surfaces. The prepared titanium discs were examined as follows. The surface morphology of the discs was examined using SEM. The surface roughness was measured by a confocal laser scanning microscope. Phase components were analyzed using thin-film x-ray diffraction. Wettability analyses were performed by contact angle measurement with distilled water, formamide, bromonaphtalene and surface free energy calculation. Results. (1) The four groups showed specific microtopography respectively. Anodized and calcium phosphate coated specimens showed multiple micropores and tiny homogeneously distributed crystalline particles. (2) The order of surface roughness values were, from the lowest to the highest, machined group, anodized group, anodized and calcium phosphate deposited group, and sandblasted and acid etched group. (3) Anodized and calcium phosphate deposited group was found to have titanium and titanium anatase oxides and exhibited calcium phosphorous crystalline structures. (4) Surface wettability was increased in the order of calcium phosphate deposited group, machined group, anodized group, sandblasted and acid etched group. Conclusion. After ion beam-assisted deposition on anodized titanium, the microporous structure remained on the surface and many small calcium phosphorous crystals were formed on the porous surface. Nanoscale calcium phosphorous deposition induced roughness on the microporous surface but hydrophobicity was increased.

The effect of $Ni^{2+}$ on the intracellular $Ca^{2+}$ increase of the mouse early 2-cell embryos (생쥐 초기 2-세포 배에서 세포 내 칼슘 농도의 변화에 $Ni^{2+}$이 미치는 영향)

  • Yoon, Sook-Young;Lee, Eun-Mi;Bae, In-Ha
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.30 no.4
    • /
    • pp.269-280
    • /
    • 2003
  • Objective: We reported the overcoming effect of $Ni^{2+}$ on the in vitro 2-cell block of mouse embryos. In this study, we aim to investigate whether $Ni^{2+}$ should induce intracellular $Ca^{2+}$ transient in the mouse embryos. Materials and Methods: Embryos were collected at post hCG 32hr from the oviduct of the ICR mouse and cultured in M2 medium omitted phenol red. Intracellular $Ca^{2+}$ was checked by using a confocal laser scanning microscope and fluo-3AM by using various intracellular $Ca^{2+}$ antagonists. Results: In 1mM $Ni^{2+}$ treated medium which contained $Ca^{2+}$(1.71mM), 75.7% of the embryos showed $[Ca^{2+}]i$ transient about 200 sec later. In the $Ca^{2+}$-free medium, 69.8% of the embryos showed $[Ca^{2+}]i$ transient. In U73122, phospholipaseC(PLC) inhibitor (5uM, 10min) pretreated group, 33.3% of the embryos showed $[Ca^{2+}]i$ transient. Heparine, inositol 1, 4, 5-triphosphate receptor(IP3R) antagonist preinjected embryos showed no response with 1mM $Ni^{2+}$. In danthrolene treatment, ryanodine receptor(RyR)-antagonist, 43% embryos showed $[Ca^{2+}]i$ transient but they showed delayed response about 340sec in the presence of $Ca^{2+}$. Conclusions: Summing up the above results, $Ni^{2+}$ seems to induce $Ca^{2+}$-release from the $Ca^{2+}$-store even in the $Ca^{2+}$-free medium. IP3 receptors of the mouse 2-cell embryos might have an essential role for the intracellular $Ca^{2+}$ increase by $Ni^{2+}$.

Push-out bond strength and dentinal tubule penetration of different root canal sealers used with coated core materials

  • Sungur, Derya Deniz;Purali, Nuhan;Cosgun, Erdal;Calt, Semra
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.114-120
    • /
    • 2016
  • Objectives: The aim of this study was to compare the push-out bond strength and dentinal tubule penetration of root canal sealers used with coated core materials and conventional gutta-percha. Materials and Methods: A total of 72 single-rooted human mandibular incisors were instrumented with NiTi rotary files with irrigation of 2.5% NaOCl. The smear layer was removed with 17% ethylenediaminetetraacetic acid (EDTA). Specimens were assigned into four groups according to the obturation system: Group 1, EndoRez (Ultradent Product Inc.); Group 2, Activ GP (Brasseler); Group 3, SmartSeal (DFRP Ltd. Villa Farm); Group 4, AH 26 (Dentsply de Trey)/gutta-percha (GP). For push-out bond strength measurement, two horizontal slices were obtained from each specimen (n = 20). To compare dentinal tubule penetration, remaining 32 roots assigned to 4 groups as above were obturated with 0.1% Rhodamine B labeled sealers. One horizontal slice was obtained from the middle third of each specimen (n = 8) and scanned under confocal laser scanning electron microscope. Tubule penetration area, depth, and percentage were measured. Kruskall-Wallis test was used for statistical analysis. Results: EndoRez showed significantly lower push-out bond strength than the others (p < 0.05). No significant difference was found amongst the groups in terms of percentage of sealer penetration. SmartSeal showed the least penetration than the others (p < 0.05). Conclusions: The bond strength and sealer penetration of resin-and glass ionomer-based sealers used with coated core was not superior to resin-based sealer used with conventional GP. Dentinal tubule penetration has limited effect on bond strength. The use of conventional GP with sealer seems to be sufficient in terms of push-out bond strength.

Encapsulation of Lactobacillus rhamnosus GG Using Milk Protein-Based Delivery Systems: Effects of Reaction Temperature and Holding Time on Their Physicochemical and Functional Properties

  • Ayu, Istifiani Lola;Ha, Ho-Kyung;Yang, Dong-Hun;Lee, Won-Jae;Lee, Mee-Ryung
    • Food Science of Animal Resources
    • /
    • v.41 no.5
    • /
    • pp.894-904
    • /
    • 2021
  • Microencapsulation is a protective process for materials that are sensitive to harsh conditions encounted during food manufacture and storage. The objectives of this research were to manufacture a milk protein-based delivery system (MPDS) containing Lactobacillus rhamnosus GG (LGG) using skim milk powder and to investigate the effects of manufacturing variables, such as reaction temerpature and holding time, on the physiccohemical properties of MPDS and viability of LGG under dairy food processing and storage conditions. MPDS was prepared using chymosin at varing reaction temperatures from 25℃ to 40℃ for 10 min and holding times from 5 to 30 min at 25℃. The morphological and physicochemical properties of MPDS were evaluated using a confocal laser scanning microscope and a particle size analyzer, respectively. The number of viable cells were determined using the standard plate method. Spherical-shaped MPDS particles were successfully manufactured. The particle size of MPDS was increased with a decrease in reaction temperature and an increase in holding time. As reaction temperature and holding time were increased, the encapsulation efficiency of LGG in MPDS was increased. During pasteurization, the use of MPDS resulted in an increase in the LGG viability. The encapsulation of LGG in MPDS led to an increase in the viability of LGG in simulated gastric fluid. In addition, the LGG viability was enhanced with an increase in reaction temperature and holding time. In conclusions, the encapsulation of LGG in MPDS could be an effective way of improving the viability of LGG during pasturization process in various foods.

Characterization of Oleogels and Oleogel Emulsions Made with Sucrose Ester and Ceramide as Mixed Gelators (수크로스 에스터와 세라마이드를 혼합 겔레이터로 사용한 올레오겔과 올레오겔 에멀젼의 특성 분석)

  • Dayeon Lee;Byung Suk Jin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.5
    • /
    • pp.501-506
    • /
    • 2023
  • Oleogel and oleogel emulsions of sunflower oil were prepared using sucrose ester and ceramide as mixed gelators. The crystal structure of the gelator in the oleogels and oleogel emulsion formulations was observed with a polarized optical microscope, and the dispersion form of water was confirmed with confocal laser scanning microscopy. Through the DSC thermogram analysis, it was confirmed that the crystal structure of ceramide disappeared when sucrose ester and ceramide were mixed, and the crystallinity of the mixed gelator increased further when water was added to the formulation. Changes in rheological properties such as viscosity and viscoelasticity according to the ratio of sucrose ester, ceramide, and water in the formulation were examined. As the content of ceramide and water increased, the viscosity, storage modulus, and loss modulus all increased, and the stability of the formulation also tended to increase.