• Title/Summary/Keyword: Scanner Motor

Search Result 65, Processing Time 0.027 seconds

Acupuncture stimulation for motor cortex activities: Evidence from 3T functional MRI study

  • 최보영;전신수;유승식;최기순;박상동;임은철;정성택;이형구;서태석
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.85-85
    • /
    • 2003
  • Purpose: To investigate whether or not acupuncture of GB34 produces a significant response of the modulation of somatomotor areas by functional magnetic resonance imaging (fMRI) study. Materials and methods: The acupoint, GB34, located in the back of the knee, is known to be effective in recovering motor function after stroke. Using 3T MRI scanner, functional MR imaging of the whole brain was peformed in 12 normal healthy subjects during two stimulation paradigms; acupuncture manipulation on GB34 and sham points. This study investigates the activation of the motor cortex elicited by a soft and an intensified stimulation of GB 34.Three different paradigms were carried out to detect any possible modulation of the Blood Oxygenation Level Dependent (BOLD) response in the somatomortor area to motor stimulation through acupuncture.

  • PDF

Characteristics of CCD Based Optical CT Scanner for Therapeutic Radiation Dosimetry (치료방사선량평가를 위한 CCD 기반 광학컴퓨터단층촬영 스캐너의 특성)

  • Lee, Jae Choon;Kim, Ae Ran;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.72-78
    • /
    • 2016
  • A CCD camera and an LED light source were combined to fabricate a compact optical CT scanner for the therapeutic radiation dose evaluation of a polymer gel dosimeter. After the collimated beam emitted by the LED passed through aquarium, gel phantom, and telecentric lens, an image was collected by the CCD camera and reconstructed using MATLAB. By using a stepping motor and LabVIEW, the gel dosimeter was rotated at every $0.72^{\circ}$, and the time for collecting 500 slice images per a revolution was within 20 min. At a spatial frequency of 4.5 lp/mm of the optical CT scanner, the modulation transfer function value was 72%. The linear correlation coefficient of the optical CT scanner for the polymer gel dosimeter was 0.987.

Implementation of the laser scanning using the step motor (스텝모터를 활용한 정밀 스케닝 구현에 관한 고찰)

  • Chun, Sam-Suk;Park, Chan-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.967-968
    • /
    • 2007
  • This report is the study for laser scanning. Scanning control of $CO_2$ laser, He-Ne laser, used for the treatment of body skin, has relatively low band about hundered Hz. It could be used as a substitiute for expensive galvanometer that is the established scan method, which operates the number of KHz movement by using step motor when it operates low speed. To increase the accuracy of step motor's the angle of rotation, We could materialize 100Hz low band by using open loop, closed loop method with microprocessor. This causes it to be stable even direction by attaching electric capacity sensor. Therefore, We could expect to reduce the cost by manufacturing low band scanner rather than costly feedback galvanometer.

  • PDF

Development of a Noncontact Three Dimensional Foot Form Measurement System with Optical Triangulation (광삼각법을 이용한 비접촉 3차원 족형 측정 시스템 설계)

  • 박인덕;안형회;송강석;이희만;김시경
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.5
    • /
    • pp.368-373
    • /
    • 2003
  • This paper presents a cost-effective 3D foot scanner system that provides the 3-dimensional point cloud foot data to design the custom footwear. To measure the 3-dimensional point cloud data of the foot, a CCD camera, a Non-Gaussian laser line projector and optical triangulation method are employed. Furthermore, the integrated system employs a measurement base, a frame grabber, a CCD moving cart, a stepping motor and a computer. The measurement result is saved as 3D dxf format and it could be converted to 2D essential data fer a shoe design. The experimental results demonstrate that the proposed system have the decent resolution of 1mm which is enough for last and shoe design.

Design and Performance Verification of Active Phased Array Antenna Near-Field Scanner with Mobility (이동성을 구비한 능동위상배열안테나 근접전계 스캐너 설계 및 성능 검증)

  • Yoo, Woo-Sung;Kim, Sung-Gyun;Kwon, Yong-Wook;Jung, Gi-Young;Jang, Heon-Soon
    • Journal of IKEEE
    • /
    • v.21 no.1
    • /
    • pp.30-38
    • /
    • 2017
  • It is necessary to check the fault of phased array antenna, when the active phased array radar installed in the site is suspected performance degradation due to external impact or long-term operation. However, the near-field test should be performed in anechoic chamber in order to measure the phased array antenna, so that much time and cost must be applied for radar disassembly and transportation, and the operational availability of the radar system is deteriorates. Therefore, we propose a near-field scanner with mobility to check the fault of the phased array antenna at the site, and the effectiveness of the proposed scanner was verified with ${\pm}0.5dB$ magnitude and ${\pm}1.5^{\circ}$ phase in comparison with measured data in anechoic chamber.

Estimation of Hemispherical Aerodynamic Bearing using Experimental Method (반구형 공기동압 베어링의 실험적 평가)

  • 김영일
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.239-244
    • /
    • 1997
  • Recently, the high speed rotation and accuracy is needed in the field of electro-optic devices. But it is difficult for ball bearing to satisfy such conditions. So, we have developed the hemispherical type aerodynamic bearing for LSU(Laser Scanning Unit) motor. The hemispherical type aerodynamic bearing is able to support radial and axial load simultaneously. In this research, We have developed mass production method and tested the perromance of aerodynamic bearing in comparision with ball bearing at the speed of 23,000rpm. In the result, we proved that the properties of aerodynamic bearing is better than ball bearing's.

  • PDF

Bearings for high-speed scanner motor (레이저 스캐너 모터용 베어링의 개발)

  • 정광섭;장성훈;이영제;이기영;박기훈;최형민;정대현;이창조
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.252-257
    • /
    • 1998
  • 레이저 프린터에 사용되는 스케너 모터의 안정적인 베어링을 개발하기 위해서 함유소결 베어링과 빗살무늬 유체베어링을 개발하였다. 함유소결베어링은 9,000~20,000 rpm까지에서 매우 우수한 마찰 및 접촉특성을 나타내었으며, 빗살무늬 유체베어링에서는 35,000rpm까지 우수한 특성을 나타내었다.

  • PDF

Analysis on Vibration Source of Sheet Feeding Apparatus for Digital MFP (Multi-Functional Product) (디지털 복합기 용지이송기구의 가진원 분석)

  • Kim, Hyoung-Rae;Seo, Hong-Seung;Chung, Jin-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.71-76
    • /
    • 2011
  • In this paper, we investigate the vibration source of sheet feeding apparatus installed in scanner cover of the digital MFP through frequency analysis. Gearmesh frequency and motor generated frequency were calculated to analyse autospectrum. During driving state, we measure the vibration level. It was found from the signal analysis that gearmesh frequency and motor generated frequency are identified as vibration source.

  • PDF

Clinical Application of Functional MRI : Motor Cortex Activities by Acupuncture

  • Choe, Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.6 no.2
    • /
    • pp.89-93
    • /
    • 2002
  • We report a preliminary fMRI evidence of modulation of somatomotor areas by acupuncture in GB34 acupoint. GB34, located in the back of the knee, is known to be effective in recovering motor function after stroke. Using 3T MR scanner, functional MR imaging was performed in five normal volunteers in two stimulation paradigms; acupuncture manipulation on GB34 and sham points. Group analysis form five individuals showed that bilateral sensorimotor areas (BA 3,4,6 and 7) showed stimulation related BOLD signal contrast of approximately 6% whereas very few areas were activated when sham stimulation is given. Our results suggest that acupuncture fMRI study can be safely conducted in 3T environment and stimulation in GB34 modulate the cortical activities of the somatomotor area in human.

  • PDF

Clinical Application of Functional MRI : Motor Cortex Activities by Acupuncture

  • Choe, Bo-Young
    • Proceedings of the Korean Magnetic Resonance Society Conference
    • /
    • 2002.08a
    • /
    • pp.21-25
    • /
    • 2002
  • We report a preliminary fMRI evidence of modulation of somatomotor areas by acupuncture in GB34 acupoint. GB34, located in the back of the knee, is known to be effective in recovering motor function after stroke. Using 3T MR scanner, functional MR imaging was performed in five normal volunteers in two stimulation paradigms; acupuncture manipulation on GB34 and sham points. Group analysis from five individuals showed that bilateral sensorimotor areas (BA 3,4,6 and 7) showed stimulation related BOLD signal contrast of approximately 6% whereas very few areas were activated when sham stimulation is given. Our results suggest that acupuncture fMRI study can be safely conducted in 3T environment, and stimulation in GB34 modulate the cortical activities of the somatomotor area in human.

  • PDF