• Title/Summary/Keyword: Scanned data

Search Result 479, Processing Time 0.028 seconds

NIS quality analysis of pre- and post-harvest sugarcane.

  • Johnson, Sarah E.;Berding, Nils
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1621-1621
    • /
    • 2001
  • The quality of sugarcane grown on the NE Australian tropical coast ($16^{\circ}$15'- $18^{\circ}$15' S Lat.) has declined markedly in the past seven years. This has been linked to dilution of mill-supply cane with increasing levels of non mature-stalk material consisting of leaves and sucker culms. The prime research objective was to examine the transition from the pre-harvest, in-field crop to harvested material sent for processing, in terms of quality and crop fraction proportions. A secondary objective was to quantify the effects of preharvest-season crop habit and culm condition on crop quality. Ten quadrat samples from each of 54 random crop sites (17 in 1999 and 37 in 2000), covering a wide range of variables (cultivar, crop class, and edaphic, topographic, climatic, and temporal factors) were collected immediately before harvest. Samples were partitioned into four fractions:- sound and unsound mature stalks (culms), sucker culms, and extraneous matter (leaves). Material harvested from each site was sampled and partitioned into four fractions:- sound and unsound billets (culm pieces), culm-spindle pieces, and leaf. In 2000, before harvest, 14 additional sites were sampled monthly, on three occasions, from March - June. Erect and non-erect culms were divided into sound and unsound classes. All samples were disintegrated and presented to a remote reflectance module of a scanning spectrophotometer using the BSES large cassette module. Near infra-red spectroscopic (NIS) analyses were developed for the rapid determination of quality components (Brix, commercial cane sugar (CCS), fibre, moisture, and polariscope reading). Calibrations for three material groups (culm (n = 639), non-culm (n = 496), and combined) were developed for all components using the 1999 data set. Two sub-sets (n = 178, and 190) of about 10% of the preharvest-season and harvest populations scanned in 2000 also were subjected to full routine laboratory analyses. The 1999 combined calibrations were excellent, but the culm calibrations produced consistently lower standard errors. Non-culm calibrations were marginally better than the combined for only CCS and pol. reading. Analysis of the 2000 culm data with calibrations using all 1999 and 2000 culm data resulted in better predictions relative to the 1999 culm calibrations. This also was true for the combined calibrations. Assessment of quality components in pre- and post-harvest sugarcane using NIS calibrations was more cost effective than using routine laboratory techniques. Outcomes from this NIS-facilitated research will have important economic consequences for the Australian sugarcane industry. Potential CCS present in mature culms is being discounted by dilution with leaves and sucker culms, threatening farm viability. The results question the efficacy of current harvesting technology. The CCS of harvested cane is improved only marginally over that of the in-field crop. Current harvesting technology requires either supplementary, innovative pre-mill processing or a design revolution to improve mill-supply cane quality, and therefore whole of industry economics. NIS-facilitated analyses, before the harvest season, highlighted the benefits of growing erect, sound crops. Loss of CCS then, can be minimized only by a combination of crop improvement and agronomic solutions, applied as part of sound on-farm management.

  • PDF

Wine quality grading by near infrared spectroscopy.

  • Dambergs, Robert G.;Kambouris, Ambrosias;Schumacher, Nathan;Francis, I. Leigh;Esler, Michael B.;Gishen, Mark
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1253-1253
    • /
    • 2001
  • The ability to accurately assess wine quality is important during the wine making process, particularly when allocating batches of wines to styles determined by consumer requirements. Grape payments are often determined by the quality category of the wine that is produced from them. Wine quality, in terms of sensory characteristics, is normally a subjective measure, performed by experienced winemakers, wine competition judges or winetasting panellists. By nature, such assessments can be biased by individual preferences and may be subject to day-to-day variation. Taste and aroma compounds are often present in concentrations below the detection limit of near infrared (NIR) spectroscopy but the more abundant organic compounds offer potential for objective quality grading by this technique. Samples were drawn from one of Australia's major wine shows and from BRL Hardy's post-vintage wine quality allocation tastings. The samples were scanned in transmission mode with a FOSS NIR Systems 6500, over the wavelength range 400-2500 ㎚. Data analysis was performed with the Vision chemometrics package. With samples from the allocation tastings, the best correlations between NIR spectra and tasting data were obtained with dry red wines. These calibrations used loadings in the wavelengths related to anthocyanins, ethanol and possibly tannins. Anthocyanins are a group of compounds responsible for colour in red wines - restricting the wavelengths to those relating to anthocyanins produced calibrations of similar accuracy to those using the full wavelength range. This was particularly marked with Merlot, a variety that tends to have relatively lower anthocyanin levels than Cabernet Sauvignon and Shiraz. For dry white wines, calibrations appeared to be more dependent on ethanol characteristics of the spectrum, implying that quality correlated with fruit maturity. The correlations between NIR spectra and sensory data obtained using the wine show samples were less significant in general. This may be related to the fact that within most classes in the show, the samples may span vintages, glowing areas and winemaking styles, even though they may be made from only one grape variety. For dry red wines, the best calibrations were obtained with a class of Pinot Noir - a variety that tends to be produced in limited areas in Australia and would represent the least matrix variation. Good correlations were obtained with a tawny port class - these wines are sweet, fortified wines, that are aged for long periods in wooden barrels. During the ageing process Maillard browning compounds are formed and the water is lost through the barrels in preference to ethanol, producing “concentrated” darkly coloured wines with high alcohol content. These calibrations indicated heaviest loadings in the water regions of the spectrum, suggesting that “concentration” of the wines was important, whilst the visible and alcohol regions of the spectrum also featured as important factors. NIR calibrations based on sensory scores will always be difficult to obtain due to variation between individual winetasters. Nevertheless, these results warrant further investigation and may provide valuable Insight into the main parameters affecting wine quality.

  • PDF

Evaluation of the accuracy of three different intraoral scanners for endocrown digital impression: An in vitro study (엔도크라운 디지털 인상을 위한 구강스캐너 3종의 정확도 평가: 실험실 연구)

  • Ural, Cagri;Park, Ji-Man;Kaleli, Necati;Caglayan, Esma
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.282-289
    • /
    • 2020
  • Purpose: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (IOSs) on digital impressions of different types of endocrown cavity preparations. Materials and methods: Two human mandibular molar teeth were prepared with different endocrown abutment designs: one with a buccal wall (Class 2) and the other without a buccal wall (Class 3). Both cavity designs were scanned using a reference desktop scanner (E3) and three different intraoral scanners: Trios3 (TRI group), Cerec Omnicam (CER group), and i500 (I5 group). The obtained Standard Tessellation Language (.stl) datasets were exported to metrology software. The precision was evaluated based on deviations among repeated scan models recorded by each IOS. The trueness was evaluated based on deviations between the reference data and repeated scans. For detecting interaction, data were statistically analyzed using a univariate analysis of variance (ANOVA) and for analyzing the comparison of the test groups data were analyzed by one-way ANOVA and post-hoc Tukey test at the significance level of .05. Results: The deviation values for both cavity designs in the I5 group were significantly lower than those in the other IOS groups in terms of trueness. For both cavity designs, the TRI group exhibited better precision than the other IOS groups. Conclusion: Different technologies of IOS device's and different endocrown prepration designs affected the accuracy of the digital scans.

A Terrain Data Acquisition for Slope Safety Inspection by Using LiDAR (지상 LiDAR에 의한 사면안전진단용 지형정보 취득)

  • Lee, Jong Chool;Kim, Hee Gyoo;Roh, Tae Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.4
    • /
    • pp.311-319
    • /
    • 2013
  • As heavy rains occur more frequently due to the recent climate change, slope collapses are increasing, and damage to human life and properties is accordingly increasing every year. The most proper method to take preventive measures against slope collapses is to remove the cause after understanding the cause of slope collapse in advance, and for such, slope safety inspection is implemented for preventive purposes, to investigate the cause, and as a measure for restoration. Thus, this Research was able to reach the following conclusion after utilizing LiDAR, which obtains detailed topographic information in a short period of time with point cloud data on slopes subject to safety inspection. First, as a result of analyzing the errors after installing a check point in the subject area, the RMSE of the horizontal location error appeared to be ${\pm}2.2cm$ and the RMSE of the vertical location error appeared to be ${\pm}3.0cm$, which shows a practically satisfactory result. Second, the economic feasibility was outstanding and obtaining accurate topographic information was available. Third, an area once scanned allowed to accurately obtain an unprescribed cross-sectional diagram in a short period of time, thus, appeared to be convenient for experts to detect dangerous sections.

Comparison of 3D Scanned Anthropometric Data between Korean and American Adults by using Ratios and Indices (지수치를 활용한 한국과 매국 성인 3차원 인체치수 비교)

  • Yi, Kyong-Hwa;Istook, Cynthia
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.6
    • /
    • pp.959-967
    • /
    • 2008
  • The body measurement ratios and indices used in this study are all 3D female measurement data of the two countries were obtained from Size Korea Project and SizeUSA Project. The purpose of the study is to compare and analyze body measurement data between two countries. The results of this research are helpful for the clothing manufacturer and company to trade with America. The samples were 1,988 Korean and 6,306 American females. Thirty-five body measurement ratios and indices were chosen as the principal measurements in making garments. The conclusion of this research was as follow; First, U.S. females have measurements that exceed Korean women, except for crotch length total and shoulder slope. Second, the correlation coefficients of height and weight are relatively higher than other measurements in the two countries' body measurements. Finally, American women's height ratios are significantly bigger than Korean women's in most height ratios. On the other hand, Korean are significantly bigger than American in weight ratios. The drop values of Korean females are also smaller than those of American. It was recognized that American women are much bigger, wider and more obese than Korean according to the results by utilizing the girth ratios. BMI, Rohrer and Vervaeck index.

The Data Transmission of Image Storage System of PACS (PACS내 영상저장 장치의 데이터 전송)

  • Cho, EuyHyun;Park, Jeongkyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.785-791
    • /
    • 2018
  • Recently, Disk array is widely used as a long term storage device in PACS, but reliability is not enough in relation to annual failure rate of disk. Between October 2016 and February 2017, we scanned the serial port of the hard disk while reading or storing medical images on a PACS reader. The data rate was calculated from the data stored in HDD 99ea that were used in the PCAS image storage device and in HDD 101ea that were used in the Personal Computer. When a CT image was read from a PACS reader, Reading was 87.8% and Writing was 12.2% in units of several tens of megabytes or less. When the CT image was stored in the PACS reader, Reading was 11.4% and Writing was 88.6% in units of several tens of megabytes or less. While reading the excel file on the personal computer, Reading was 75% and Writing was 25% in less than 3 MB, and In the process of storing the excel file on the personal computer, Reading was carried out by 38% and Writing was carreid out 62% in the units of 3 MB or less. The transfer rate of the hard disk used in the PACS image storage device was 10 GB/h, and the transfer rate per hour of the hard disk of the personal computer was 5 GB / h. Annual failure rate of hard disk of image storage system is 0.97 ~ 1.13%, Annual failure rate of Hard Disk of personal computer is 0.97 ~ 1.13%. the higher transfer rate is, the higher annual failure rate is. These results will be used as a basis for predicting the life expectancy of the hard disk and the annual failure rate.

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

Prediction accuracy of incisal points in determining occlusal plane of digital complete dentures

  • Kenta Kashiwazaki;Yuriko Komagamine;Sahaprom Namano;Ji-Man Park;Maiko Iwaki;Shunsuke Minakuchi;Manabu, Kanazawa
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.281-289
    • /
    • 2023
  • PURPOSE. This study aimed to predict the positional coordinates of incisor points from the scan data of conventional complete dentures and verify their accuracy. MATERIALS AND METHODS. The standard triangulated language (STL) data of the scanned 100 pairs of complete upper and lower dentures were imported into the computer-aided design software from which the position coordinates of the points corresponding to each landmark of the jaw were obtained. The x, y, and z coordinates of the incisor point (XP, YP, and ZP) were obtained from the maxillary and mandibular landmark coordinates using regression or calculation formulas, and the accuracy was verified to determine the deviation between the measured and predicted coordinate values. YP was obtained in two ways using the hamularincisive-papilla plane (HIP) and facial measurements. Multiple regression analysis was used to predict ZP. The root mean squared error (RMSE) values were used to verify the accuracy of the XP and YP. The RMSE value was obtained after crossvalidation using the remaining 30 cases of denture STL data to verify the accuracy of ZP. RESULTS. The RMSE was 2.22 for predicting XP. When predicting YP, the RMSE of the method using the HIP plane and facial measurements was 3.18 and 0.73, respectively. Cross-validation revealed the RMSE to be 1.53. CONCLUSION. YP and ZP could be predicted from anatomical landmarks of the maxillary and mandibular edentulous jaw, suggesting that YP could be predicted with better accuracy with the addition of the position of the lower border of the upper lip.

A research on improving signal to noise ratio for magnetic resonance imaging through increasing filling factor inside surface coil (자기공명 검사시 코일 내 filling factor 증가를 통한 신호대 잡음비의 향상에 관한 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5299-5304
    • /
    • 2012
  • MRI signals are significantly reduced by the magnetic field inhomogenity result from human body itself being consisted of various materials like air, fat, muscle, bone and blood vessels. In this study we used silicon which is tissue equivalent to compensate wound body shapes. Objects were eight adults who do not have any special symptoms. Feet were scanned because of their complicated structures and consequently signal reduction occurs a lot. Thirty images were acquired from the middle of arcus pedis longitudinalis including five distal phalanges parallel to the line connecting metatarsal bone and phalanges. SNR data from bones and soft tissues were compared before and after sticking silion between toes and paired t test was performed. It was came out that SNR data from bone and soft tissue were both significantly higher after applying silicon on both T1 and T2 weighted images and it was statistically meaningful having positive corelation. As a result, this study dramatically increases SNR without affecting object by increasing the object volume inside the surface coil.

Clinicopathological Features in Bilateral Breast Cancer

  • Baykara, Meltem;Ozturk, Selcuk Cemil;Buyukberber, Suleyman;Helvaci, Kaan;Ozdemir, Nuriye;Alkis, Necati;Berk, Veli;Koca, Dogan;Coskun, Ugur;Oksuzoglu, Berna;Uncu, Dogan;Arpaci, Erkan;Ustaalioglu, Basak Oven;Demirci, Umut;Kucukoner, Mehmet;Dogu, Gamze Gokoz;Alici, Suleyman;Akman, Tulay;Ozkan, Metin;Aslan, Ulku Yalcintas;Durnali, Ayse Gok;Benekli, Mustafa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4571-4575
    • /
    • 2012
  • Introduction and Purpose: The frequency of bilateral breast cancer is 1.4-11.0% among all breast cancers. It can present as synchronous (SC) or metachronous (MC). Data regarding clinical course of bilateral breast cancer are scarce. In this study, we therefore evaluated demographic, pathological and clinical characteristics, treatments and responses in bilateral breast cancer cases; making distinctions between metachronous-synchronous and comparing with historic one-sided data for the same parameters. Materials and Methods: One hundred fifty bilateral breast cancer cases from ten different centers between 2000 and 2011 were retrospectively scanned. Age of the cases, family history, menopausal status, pathological features, pathological stages, neoadjuvant, surgery, adjuvant and palliative chemotherapy/radiotherapy were examined in the context of the first and second occurrence and discussed with reference to the literature. Results: Metachronous and synchronous groups showed similar age, menopausal status, tumor type, HER2/neu expression; the family history tumor grade, tumor stage, ER-negativity rate, local and distant metastases rates, surgery, adjuvant chemotherapy application rates were identified as significantly different. Palliative chemotherapy response rate was greater in the metachronous group but median PFS rates did not differ between the groups. Conclusion: Although bilateral breast cancer is not frequent, MC breast cancer is different from SC breast cancer by having more advanced grade, stage, less ER expression, more frequent rates of local relapse and distant metastasis and better response to chemotherapy in case of relapse/metastasis.