• 제목/요약/키워드: Scan technique

검색결과 594건 처리시간 0.024초

New Digital Esthetic Rehabilitation Technique with Three-dimensional Augmented Reality: A Case Report

  • Hang-Nga, Mai;Du-Hyeong, Lee
    • Journal of Korean Dental Science
    • /
    • 제15권2호
    • /
    • pp.166-171
    • /
    • 2022
  • This case report describes a dynamic digital esthetic rehabilitation procedure that integrates a new three-dimensional augmented reality (3D-AR) technique to treat a patient with multiple missing anterior teeth. The prostheses were designed using computer-aided design (CAD) software and virtually trialed using static and dynamic visualization methods. In the static method, the prostheses were visualized by integrating the CAD model with a 3D face scan of the patient. For the dynamic method, the 3D-AR application was used for real-time tracking and projection of the CAD prostheses in the patient's mouth. Results of a quick survey on patient satisfaction with the two visualization methods showed that the patient felt more satisfied with the dynamic visualization method because it allowed him to observe the prostheses directly on his face and be more proactive in the treatment process.

구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례 (Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique)

  • 홍용신;박은진;김선종;김명래;허성주;박지만
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.67-73
    • /
    • 2012
  • 최근 디지털 인상채득 시스템이 개발되면서 이를 기존의 CAD/CAM 시스템과 접목한 인레이, 온레이, 크라운이나 간단한 계속가공의치 등의 고정성 보철물의 제작이 활발히 소개되고 있다. 그러나 임플란트 보철에서는 주로 기존의 아날로그식 인상채득 후 이를 스캔하여 제작하는 방법이 사용되어 왔으나, 구강 내 디지털 스캔한 데이터를 이용하여 나사형 보철물을 제작하는 술식은 아직 활발히 이루어지지 않았다. 이에 본 증례보고에서는 6명의 환자를 대상으로 구강 내 스캐너인 iTero를 사용하여 디지털 스캔을시행한후그중다섯명은맞춤형지대주와 시멘트 합착 후 나사형 임플란트 보철물(screw-retained implant prosthesis after cementation, or SCRP)을 제작하였고, 임상적으로 기능과 심미적인 측면으로 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

어블레이션 영역 레이저 초음파의 시뮬레이션과 내부결함 검사 (Simulations for Internal Defect Inspection Using Laser Generated Ultrasonic Wave in Ablation Regime)

  • 김진겸;최성호;장경영
    • 비파괴검사학회지
    • /
    • 제34권3호
    • /
    • pp.226-232
    • /
    • 2014
  • 본 연구에서는 고출력 레이저를 재료 표면에 조사하였을 때 나타나는 어블레이션 현상에 의한 레이저 초음파의 특성을 시뮬레이션과 실험을 통해 분석하였다. 레이저 초음파 기법은 비파괴검사 분야에서 기존의 접촉식 초음파 기법을 적용하기 어려운 환경요인(고온 등)을 극복할 수 있는 장점들을 가지고 있다. 특히, 어블레이션 영역에서는 종파의 신호 세기 및 직진성이 강하므로, 투과 및 반사 신호를 통한 내부결함 검사법으로 활용하기 적합하다. 본 논문에서는 유한요소해석을 통해 어블레이션 영역에서의 레이저 초음파의 발생 및 전파를 해석하였다. 그리고 개발된 유한요소해석 모델을 활용해 결함모사시편을 대상으로 B-Scan을 수행한 결과, 실험 결과와 동일하게 나타나는 것을 확인하였고, 이로부터 개발된 해석모델의 타당성을 검증할 수 있었다.

전기화학적 방법에 의한 내열강의 열화도측정 제2보 : 열화도측정치에 미치는 측정조건들의 영향과 기계적성질 변화에 대해서 (Degradation Degree Evaluation of Heat Resisting Steel by Electrochemical Technique Part 2 : Effect of Testing Conditions on Evaluation Value of Degradation Degree and Changes of Mechaical Properties)

  • 정희돈;권영각;장래웅
    • 대한기계학회논문집
    • /
    • 제17권2호
    • /
    • pp.300-312
    • /
    • 1993
  • The material deterioration of service-exposed boiler tube steels in fossil power plant was evaluated by using the electrochemical technique namely, modified electrochemical potentiokinetic reactivation(EPR). It was focused that the passivation of Mo$_{6}$C carbide which governs the mechanical properties of Mo alloyed steels did not occur even in the passivity region of steel in sodium molybdate solution and the reactivation peak current (Ip) observed as the result of non-passivation indicating the precipitation of Mo$_{6}$C carbides. To obtain the optimal test conditions for the field test by using the specially designed electrochemical cell, the effects of scan rate, the surface roughness and the pH of electrolyte on Ip value were also investigated. Furthermore, the change of mechanical properties occurred during the long time exposure at high temperature was evlauated quantitatively by small punch(SP) tests and micro hardness test taking account of the metallurgical changes. It is known that reactivation peak current (Ip) has a good relationship with Larson-Miller Parameter(LMP) which represents the information about material deterioration occurred at high temperature environment. In addition it was possible to estimate the ductile-brittle transition temperature (DBTT) by means of the SP test. The Sp test could be, therefore, suggested as a reliable test method for evaluating the material degradation of boiler tube steels. From the good correaltion between the SP DBTT and Ip values shown in this study, it was knows that the change of mechanical properties could be evaluated non-destructively by measurring only Ip values.ues.

전자적 스캔에 의한 미소결함길이 평가기법 (A Small Crack Length Evaluation Technique by Electronic Scanning)

  • 조용상;김재훈
    • 비파괴검사학회지
    • /
    • 제29권1호
    • /
    • pp.15-20
    • /
    • 2009
  • 초음파에 의한 결함평가 방법은 결과가 검사자의 경험과 지식에 의존되고 검사자에 따라 평가결과가 달라진다. 위상배열 초음파는 탐촉자 소자에 초음파를 발생하는 시간지연을 부여함으로서 초음파 빔의 집속방향과 위치를 전자적으로 제어할 수 있는 특징이 있으며 탐촉자를 움직이지 않고 결함의 평가가 가능하다. 본 연구에서는 위상배열 초음파의 전자적 스캔 특성을 이용하여 미소결함에 대한 크기평가의 기법에 대한 고찰을 하였다. 일반적으로 탐촉자를 움직여서 결함길이를 평가하는 기존의 방법은 결함의 길이가 아주 미소할 경우는 탐촉자의 이동거리 역시 미소하여 크기를 평가하기가 곤란하다. 따라서 전자적 스캔의 특성을 이용하여 미소결함에 대해서도 결함길이를 정확하게 평가할 수 있는 방법 및 기법에 대하여 고찰하여 그 유효성을 입증하였다.

Estimation of Genetic Correlations and Selection Responses for Carcass Traits between Ultrasound and Real Carcass Measurements in Hanwoo Cows

  • Son, Jihyun;Lee, Deukhwan
    • Journal of Animal Science and Technology
    • /
    • 제55권6호
    • /
    • pp.501-508
    • /
    • 2013
  • This study was conducted to determine genetic correlations among carcass traits measured by ultrasound and real carcass measurements and to estimate indirect selection responses for real carcass traits based on ultrasound measurements in Hanwoo cows. To accomplish this, 22,080 ultrasound measurement records from 17,926 cows collected from 2001 to 2012 and 11,907 carcass records obtained from fattened cattle from 2008 to 2012 were used. Genetic parameters were estimated based on eye muscle area (EMA), backfat thickness (BF) and marbling score (MS) measured by ultrasound-scanning of live cows and using the official technique on chilled bovine half-carcasses after slaughtering. Heritability and genetic correlation for carcass traits were estimated using a mixed model equation that consisted of environmental effects as fixed parameters and additive genetic effects and residual effects as random parameters, assuming that traits were different between ultrasound and carcass measurements. This statistical method was applied to the average information restricted maximum likelihood method. The heritability of EMA, BF and MS measured by ultrasound were 0.33, 0.61 and 0.46, respectively, while the heritability estimates of the corresponding traits based on carcass measurements were 0.29, 0.40 and 0.38, respectively and the genetic correlation between ultrasound and carcass traits for EMA, BF and MS were 0.41, 0.78 and 0.67, respectively. The genetic correlation between ultrasound and carcass traits was highly positive. Additionally, the selection response for marbling score was estimated to be 0.42 per generation if the cows were selected based on the ultrasound scan marbling score with an assumed selection intensity of 0.8. Overall, these results indicate that the ultrasound scan technique would be applicable to judging cow selection for genetically improved meat quality.

Dual-Sensor 기반 스테레오 X-선 영상의 3차원 형상복원기술을 이용한 검색 자동화를 위한 연구 (The Study of automated inspection technology using a three-dimensional reconstruction of stereo X-ray image based dual-sensor Environment)

  • 황영관;이남호;김종열
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.695-698
    • /
    • 2014
  • 화물 검색용으로 사용되고 있는 X-선 검색장치는 대상물의 단면 정보만을 제공하고 있기에 검색 대상체의 식별에 어려움이 있어 이에 대한 개선이 요구되어 왔다. 또한 대량의 화물 검색을 효율적으로 수행하기 위해서는 검색시스템에 대한 자동화가 요구되며 자동화를 위해서는 대상체를 식별하기 위한 다양한 식별자가 필요하다. 스테레오 X-ray 시스템은 기존의 검색 장치에 라인센서를 추가하여 검색 대상체에 대한 추가적인 정보를 제공함으로써 검색 효율을 높이도록 고안되었다. 본 논문에서는 선행 연구를 통해 개발된 스테레오 X-선 검색장치를 이용하여 다양한 물체에 대한 검색을 수행하며 형상정보를 복원하여 실제 값과의 비교를 통해 스테레오 방사선 스캔장치에 대한 성능분석을 수행하였다. 또한 본 논문에서 제시하는 3차원 형상복원 알고리즘을 통해 검색시스템을 자동화할 수 있는 새로운 식별자의 제공이 가능하다고 판단된다. 본 연구의 결과는 대형 화물 스캔 장치 및 고속화물 스캔 장치 개발을 위해 활용될 수 있다.

  • PDF

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

대구경 탐촉자를 이용한 초음파 현미경 시스템 연구 (A Study of the Acoustic Microscope System by Large Aperture Probe)

  • 조용상;김재훈
    • 비파괴검사학회지
    • /
    • 제23권5호
    • /
    • pp.475-479
    • /
    • 2003
  • 재료에 존재하는 미소균열을 검출하기 위한 일반적인 초음파 탐상법은 고주파수 집속형 수직 초음파 탐촉자를 이용한 펄스-에코법을 사용하거나 표면파를 발생시키는 사각 탐상법을 사용한다. 이러한 방법들은 압연 롤, 세라믹 롤등 대형 구조물의 표면에 존재하는 미소 크랙의 존재 여부 및 위치 측정을 위한 자동화 초음파 탐상장치를 구성하기에는 다랑의 검사 데이터, 결함 위치정보의 불확실성 등 현실적으로 많은 어려움이 있다. 본 연구에서는 고정밀도 초음파 현미경(scanning acoustic microscope)에 비교적 저주파수의 대구경 초음파 탐촉자를 사용하여 미세균열의 존재 여부 및 위치 등의 검사결과를 실시간 A, B, C-Scan으로 표시할 수 있으며, 기존의 방법보다 검사 속도 및 시간을 10배 이상으로 향상된 파동화 초음파 탐상법 및 초음파 현미경법의 실용성을 검증하였다.

근골격계 종양에서 탈륨 스캔의 역할 (The Role of Thallium-201 Scintigraphy in Bone and Soft Tissue Tumor)

  • 신덕섭
    • Journal of Yeungnam Medical Science
    • /
    • 제20권2호
    • /
    • pp.117-128
    • /
    • 2003
  • Thallium-201 scintigraphy is used to discriminate the malignant bone tumor from the benign by qualitatively and quantitatively, and to predict the response of preoperative chemotherapy in osteosarcoma, by comparing the changes of thallium uptake ratio after chemotherapy to the tumor necrosis ratio. Thallium-201 scintigraphy scan should be done prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator is usually used for scanning. The patient is injected with 2-3mCi of Tl-201 and the early phase is checked in 30 minutes and delayed phase in 3 hours. The scan images are visually evaluated by a blinded nuclear medicine physician. We could evaluate true positive, true negative, false positive and false negative by the comparison of results with those of biopsy, and calculate positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%). For the quantitative analysis of thallium uptake, we drew the region of interest on the tumor side and contralateral normal side as mirror image, and calculated the uptake ratio with dividing the amount of gamma count in tumor side by normal side. We could calculate the percent changes of thallium uptake ratio in early and delayed phase, and compare them to the ratio of tumor necrosis. Thallium-201 scintigraphy proved as useful imaging study to discriminate malignant bone tumor from benign, but had exception in giant cell tumor and low grade malignant bone tumors. We can use T1-201 scan to differentiate the benign from the malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF