• Title/Summary/Keyword: Scan technique

Search Result 594, Processing Time 0.025 seconds

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF

A Fast Sensing Method using Concurrent Driving and Sequential Sensing for Large Capacitance Touch Screens (동시구동 및 순차센싱을 이용한 대형 정전용량 터치스크린용 고속 센싱 기법)

  • Mohamed, Mohamed G.A.;Kim, HyungWon;Cho, Tae-Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • Recently the demand for projected capacitance touch screens is sharply growing especially for large screens for medical devices, PC monitors and TVs. Large touch screens in general need a controller of higher complexity. They usually have a larger number of driving and sensing lines, and hence it takes longer to scan one frame for touch detection leading to a low frame scan rate. In this paper, a novel touch screen control technique is presented, which scans each frame in two steps of simultaneous multi-channel driving. The first step is to drive all driving lines simultaneously and determine which sensing lines have any touch. The second step is to sequentially rescan only the touched sensing lines, and determine exact positions of the touches. This technique can substantially increase the frame scan rate. This technique has been implemented using an FPGA and an AFE board, and tested using a commercial 23-inch touch screen panel. Experimental results show that the proposed technique improves the frame scan rate by 8.4 times for the 23-inch touch screen panel over conventional methods.

Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report (지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고)

  • Shilpa;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • Tardive dyskinesia is an involuntary neurological movement disorder caused by long-term use of dopamine receptor-blocking drugs leading to dental implications like uncontrolled gnashing and grinding of teeth which in turn imperil the oral rehabilitation procedures as the excessive load increases the risk of prosthesis fracture. A 40-year male with a medical history of tardive dyskinesia visited the hospital to receive oral rehabilitation for missing maxillary anterior teeth. After the oral examination, tooth preparation was done on teeth 13, 15, and 23. After that silicon impression was made and the gypsum cast was digitalized using a desktop scanner and an interim prosthesis was fabricated by milling a resin block. During the try-in, the occlusal one-third of the interim prosthesis was trimmed, and an auto-polymerizing acrylic resin was applied on the occlusal surfaces and inserted in the patient's mouth. Then, the functionally generated path (FGP) of occluding surfaces of opposing arches was traced on the resin surface. When the resin was hardened, the modified interim prosthesis was removed and digitized using an intraoral scanner. The scan image was used in designing the occlusal morphology of definitive prosthesis by modifying the design of the interim prosthesis using the dual scan method. Lastly, a monolithic zirconia prosthesis was fabricated by milling a zirconia block. The definitive prosthesis was delivered reflecting the patient's occlusal scheme. This case report shows that the FGP technique with the dual scan method can help in fabricating fixed prosthesis with harmonious occlusion in a tardive dyskinesia patient.

A Reliability Study of the Phased Array Ultrasonic Testing: Case Study for the Composite Blades of Wind Power Generation (위상배열 초음파 탐지검사의 신뢰성에 관한 연구: 풍력발전기 복합소재 블레이드 사례연구)

  • Kang, Byung Kwon;Lim, Ik Sung;Koo, Ilseob
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.338-346
    • /
    • 2016
  • Purpose: The purpose of this research is to improve the reliability of the composite material blades used for the wind power generator, by applying the phased array ultrasonic testing technique out of the many nondestructive test into the blades. Method: The wind power generation composite blades are used, as a case study, in order to evaluate the reliability of the phased array ultrasonic testing technique. Defects that are most likely occurred in the field are injected into the different locations of the three different types of artificial test pieces and then phased array ultrasonic testing technique are applied to evaluate the reliability of its effectiveness. Result: As a result of the analysis of the defect signals by applying the A scan and B scan simultaneously, depth and width of the defect could be obtained. An area of defect was proportional to the amount of energy by color in B scan image. The larger amount of energy, reflected amount of energy was appeared in the order of red, orange, yellow, blue color. Conclusion: The most reliable testing method to detect the defect in composite blades for wind power generation is considered to be the combination of the other destructive testing technique with the phased array ultrasonic testing since the PAUT alone could not detect all range of the defects in the blades.

Inflammation Scan Using $^{99m}Tc-HMPAO$ Labelled Leukocytes ($^{99m}Tc-HMPAO$를 이용한 자가백혈구표지 및 그를 이용한 염증병소의 스캔)

  • Yang, Woo-Jin;Chung, Soo-Kyo;Shinn, Kyung-Sub;Bahk, Yong-Whee;Kim, Hoon-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.219-223
    • /
    • 1989
  • Inflammation scan using radiolabelled leukocytes has high sensitivity and specificity. Several methods for labelling leukocytes have been evaluated using P-32 diisopropyl fluorophosphate (DFP-32), H-3 thymidine, Cr-51 chromate, Ga-67 citrate and Tc-99m-sulfur colloid. In-111-oxine has proved so far to be the most reliable agent for labelling leukocytes. In-111-oxine is, however, expensive, not easily available when needed, and its radiation dose to leukocytes is relatively high. Moreover, resolution of the resultant image is relatively poor. Tc-99m is still the agent of choice because of, as compared with the indium, its favorable physical characteristics, lower cost and availability. Now the technique for labelling the leukocytes with technetium is successfully obtained using the lipophilic HAPAO with higher efficiency for granulocytes than for other cells. With this technique it is possible to label leukocytes in plasma to improve the viability of the leukocytes. Inflammation scan using Tc-99m-HMPAO has been evaluated in several laboratories, and difference in methods for separation and labelling accounts for difference in efficiency, viability and biodistribution of the labelled leukocytes. We performed inflammation scan using leukocytes labelled with Tc-99m-HMPAO in three dogs 24 hours after inoculation of live E. Coli and A. Aureus in their right abdominal wall. We separated mixed leukocytes by simple sedimentation using 6% hetastarch (HES) and labelled the leukocytes with Tc-99m-HMPAO in 20% cell free plama diluted with phosphate buffer solution(Fig. 1). Uptake was high in the liver and spleen but is was minimal in the lungs on whole body scan. Kidneys and intestine showed minimal activity although it was high in the urinary bladder(Fig. 2). Uptake of labelled leukocytes in the inflammation site was do(mite on 2 hour-postinjection scan and abscess was clearly delineated on 24 hour-delayed scan with high target-to-nontarget ratio(Fig. 3, 4). Inflammation scan using mixed leukocytes labelled with Tc-99m-HMPAO is very sensitive and specific in early detection of inflammation.

  • PDF

An Efficient AP Channel Scanning Scheme for Real-time VoIP Streaming in Wireless LAN (WLAN 기반 실시간 VoIP Streaming을 위한 효율적 채널 스캐닝 기법)

  • Cheon, Young-Chang;Youn, Hee-Yong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.595-598
    • /
    • 2014
  • In order to provide the Mobile Stations operating in IEEE 802.11 Wireless LAN network with seamless handover, a comprehensive study on the functions of handover considering various networking environments and characteristics of Mobile Stations is required. Note that the channel scan process finding a new AP takes the major portion of handover time, and this is the most significant issue with seamless handover for real-time multimedia service in WLAN environment. In this paper the functions required to provide seamless handover in IEEE 802.11 WLAN network are identified, and a new scanning technique is proposed with which the Mobile Stations can selectively scan the channels to reduce the channel scan time in various network environments. Here each Mobile Station awares of the channels the neighbor APs are using by scanning them in advance according to the proposed technique. Afterwards, when handover is actually required, the optimal AP is decided quickly by scanning only the predetemined group of channels and order of scan without unnecessary scan of all the channels. In addition, proposes to enter the Scan Trigger Value and Handover Threshold Value in mobile phones in order to prevent the phenomenon can not handover.

  • PDF

Design Technique for Wide Swath SAR TOPS imaging Mode (광역관측을 위한 영상레이더 TOPS 모드 설계 기법)

  • Kim, Se-Young;Sung, Jin-Bong;Yi, Dong-Woo;Shim, Sang-Heun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.5
    • /
    • pp.466-471
    • /
    • 2015
  • In this paper, the design technique of the wide swath TOPS(Terrain Observation by Progressive Scan) imaging mode is introduced. The TOPS mode overcomes the scalloping limitations imposed by ScanSAR mode by steering the antenna pattern along track direction during the acquisition of a burst. This paper reports the operation concept of TOPS imaging and mode design result to extract the SAR operational parameters. Finally, several analyzed results such as IRF(Impulse Response Function), NESZ(Noise Equivalent Sigma Zero) and DTAR(Distributed Target Ambiguity Ratio) are presented.

IEEE1149.1 Boundary Scan Design for the Detection of Delay Defects (지연고장 탐지를 위한 IEEE 1149.1 바운다리스캔 설계)

  • Kim, Tae-Hyeong;Park, Seong-Ju
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.26 no.8
    • /
    • pp.1024-1030
    • /
    • 1999
  • IEEE 1149.1 바운다리스캔은 보드 수준에서 고장점검 및 진단을 위한 테스트 설계기술이다. 그러나, 바운다리스캔 제어기의 특성상 테스트 패턴의 주입에서 관측까지 2.5 TCK가 소요되므로, 연결선상의 지연고장을 점검할 수 없다. 본 논문에서는 UpdateDR 신호를 변경하여, 테스트 패턴 주입에서 관측까지 1 TCK가 소요되게 함으로써, 지연고장 점검을 가능하게 하는 기술을 소개한다. 나아가서, 정적인 고장점검을 위한 테스트 패턴을 개선해 지연고장 점검까지 가능하게 하는, N개의 net에 대한 2 log(n+2) 의 새로운 테스트패턴도 제안한다. 설계와 시뮬레이션을 통해 지연고장 점검이 가능함을 확인하였다.Abstract IEEE 1149.1 Boundary-Scan is a testable design technique for the detection and diagnosis of faults on a board. However, since it takes 2.5TCKs to observe data launched from an output boundary scan cell due to inherent characteristics of the TAP controller, it is impossible to test delay defects on the interconnect nets. This paper introduces a new technique that postpones the activation of UpdateDR signal by 1.5 TCKs while complying with IEEE 1149.1 standard. Furthermore we have developed 2 log(n+2) , where N is the number of nets, interconnect test patterns to test delay faults in addition to the static interconnect faults. The validness of our approach is verified through the design and simulation.