• Title/Summary/Keyword: Scan order

Search Result 587, Processing Time 0.029 seconds

Efficient Image Data Processing using a Real Time Concurrent Single Memory Input/Output Access (실시간 단일 메모리 동시 입출력을 이용한 효율적인 영상 데이터 처리)

  • Lee, Gunjoong;Han, Geumhee;Ryoo, Kwangki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.103-106
    • /
    • 2012
  • A memory access method that data are read with different sequences with writing order is a simple but important procedure in many image compression standards, such as JPEG, MPEG1/2/4, H.264, and HEVC. For real time processing, double buffering is widely used using two block sized buffers, that accesses buffers concurrently with alternative way to read and write. In some cases like a transpose memory in 2D DCT with a simple and regular access order, a single buffering which requires only single block sized buffer can be used. This paper shows that even in complex access orders there is a regularity among updating orders within a finite turns, and suggested an effective implementation method using a single block sized buffer to process concurrent read/write operation with different access orders.

  • PDF

Non-linear optical properties of PECVD nanocrystal-Si nanosecond excitation (PECVD로 제조된 나노결정실리콘 비선형 광학적특성)

  • Yang, Hyeon-Hun;Kim, Han-Wool;Kim, Joo Hoe;Kim, Chul Joong;Lee, Chang Gwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.60.2-60.2
    • /
    • 2011
  • A study of the non-linear optical properties of nanocrystal-Si embedded in SiO2 has been performed by using the z-scan method in the nanosecond and femtosecond ranges. Substoichiometric SiOx films were grown by plasma-enhanced chemical-vapor deposition(PECVD) on silica substrates for Si excesses up to 24 at/%. An annealing at $1250^{\circ}C$ for 1 hour was performed in order to precipitate nanocrystal-Si, as shown by EFTEM images. Z-scan results have shown that, by using 5-ns pulses, the non-linear process is ruled by thermal effects and only a negative contribution can be observed in the non-linear refractive index, with typical values around $-10-10cm^2/W$. On the other hand, femtosecond excitation has revealed a pure electronic contribution to the nonlinear refractive index, obtaining values in the order of 10-12 cm2/W. Simulations of heat propagation have shown that the onset of the temperature rise is delayed more than half pulse-width respect to the starting edge of the excitation. A maximum temperature increase of ${\Delta}T=123.1^{\circ}C$ has been found after 3.5ns of the laser pulse maximum. In order to minimize the thermal contribution to the z-scan transmittance and extract the electronic part, the sample response has been analyzed during the first few nanoseconds. By this method we found a reduction of 20% in the thermal effects. So that, shorter pulses have to be used obtain just pure electronic nonlinearities.

  • PDF

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF

A Fast Full-Search Motion Estimation Algorithm using Adaptive Matching Scans based on Image Complexity (영상 복잡도와 다양한 매칭 스캔을 이용한 고속 전영역 움직임 예측 알고리즘)

  • Kim Jong-Nam
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.10
    • /
    • pp.949-955
    • /
    • 2005
  • In this Paper, we propose fast block matching algorithm by dividing complex areas based on complexity order of reference block and square sub-block to reduce an amount of computation of full starch(FS) algorithm for fast motion estimation, while keeping the same prediction quality compared with the full search algorithm. By using the fact that matching error is proportional to the gradient of reference block, we reduced unnecessary computations with square sub-block adaptive matching scan based image complexity instead of conventional sequential matching scan and row/column based matching scan. Our algorithm reduces about $30\%$ of computations for block matching error compared with the conventional partial distortion elimination(PDE) algorithm without any prediction quality, and our algorithm will be useful in real-time video coding applications using MPEG-4 AVC or MPEG-2.

Utility of Spinal Injury Diagnosis Using C-Spine Lateral X-Ray and Chest, Abdomen and Pelvis Computed Tomography in Major Trauma Patients with Impaired Consciousness

  • Jang, Yoon Soo;So, Byung Hak;Jeong, Won Jung;Cha, Kyung Man;Kim, Hyung Min
    • Journal of Trauma and Injury
    • /
    • v.31 no.3
    • /
    • pp.151-158
    • /
    • 2018
  • Purpose: The regional emergency medical centers manage the patients with major blunt trauma according to the process appropriate to each hospital rather than standardized protocol of the major trauma centers. The primary purpose of this study is to evaluate the effectiveness and influence on prognosis of additional cervical-thoracic-lumbar-spine computed tomography (CTL-spine CT) scan in diagnosis of spinal injury from the victim of major blunt trauma with impaired consciousness. Methods: The study included patients visited the urban emergency medical center with major blunt trauma who were over 18 years of age from January 2013 to December 2016. Data were collected from retrospective review of medical records. Sensitivity, specificity, positive predictive value, and negative predictive value were measured for evaluation of the performance of diagnostic methods. Results: One hundred patients with Glasgow coma scale ${\leq}13$ underwent additional CTL-spine CT scan. Mechanism of injury was in the following order: driver, pedestrian traffic accident, fall and passenger accident. Thirty-one patients were diagnosed of spinal injury, six of them underwent surgical management. The sensitivity of chest, abdomen and pelvis CT (CAP CT) was 72%, specificity 97%, false positive rate 3%, false negative rate 28% and diagnostic accuracy 87%. Eleven patients were not diagnosed of spinal injury with CAP CT and C-spine lateral view, but all of them were diagnosed of stable fractures. Conclusions: C-spine CT scan be actively considered in the initial examination process. When CAP CT scan is performed in major blunt trauma patients with impaired consciousness, CTL-spine CT scan or simple spinal radiography has no significant effect on the prognosis of the patient and can be performed if necessary.

Usefulness of Application of Tube Voltage Changes to Reduce Patient Dose during Abdominal CT Follow up (반복적인 복부 컴퓨터단층촬영 시행 시 환자선량 감소를 위한 관전압 변화 적용의 유용성)

  • Yoon, Joon;Kim, HyeonJu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2021
  • In order to reduce the irresistible radiation exposure of patients who perform periodic examinations using a CT among various scan parameters a method to reduce patient dose was investigated through changes in the tube voltage close to X-ray penetrating power. As a result of the experiment 100 kVp was applied instead of 120 kVp which is commonly used in clinical practice and CTDI decreased by about 41% during scan. In addition the degree of change in image quality was measured as 1046.1±3.7 HU for CT value and 71.4±7.9 for Pixel value and statistical analysis showed no significant difference (0.05

Processing of Side Scan Sonar and SBP Data for the Artificial Reef Area (인공어초지역에 대한 사이드스캔소나와 SBP 탐사 자료처리)

  • Shin, Sung-Ryul;Lim, Min-Hyuk;Jang, Won-Il;Lim, Jong-Se;Yoon, Ji-Ho;Lee, Seong-Min
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.2
    • /
    • pp.192-198
    • /
    • 2009
  • Side scan sonar and SBP (sub-bottom profiler) play a very important role in the survey for seafloor imaging and sub-bottom profiling. In this study, we have acquired side scan sonar and SBP data from the artificial reef area. We applied digital image processing techniques to side scan sonar data in order to improve an image quality. For the enhancement of data quality and image resolution, we applied the typical seismic data processing sequence including gain recovery, muting, spectrum analysis, predictive deconvolution, migration to SBP data. We could easily estimate if artificial reef structures were settled properly and their distribution on the seafloor from the integrated interpretation of side scan sonar and SBP data. From the sampling analysis of seabed sediments, texture filtering of side scan sonar data and SBP data interpretation, we could evaluate the sediment type, distribution and thickness of seafloor sediments in detail.

Growth and Characterization of Lithium Potassium Phthalate (LiKP) Single Crystals for Third Order Nonlinear Optical Applications

  • Sivakumar, B.;Raj, S. Gokul;Kumar, G. Ramesh;Mohan, R.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3755-3760
    • /
    • 2012
  • Single crystals of lithium potassium phthalate (LiKP) were successfully grown from aqueous solution by solvent evaporation technique. The grown crystals were characterized by single crystal X-ray diffraction. The lithium potassium phthalate $C_{16}\;H_{12}\;K\;Li_3\;O_{11}$ belongs to triclinic system with the following unit-cell dimensions at 298(2) K;$a=7.405(5){\AA}$;$b=9.878(5){\AA}$;$c=13.396(5){\AA}$;${\alpha}=71.778(5)^{\circ}$;${\beta}=87.300(5)^{\circ}$;${\gamma}=85.405(5)^{\circ}$; having a space group P1. Mass spectrometric analysis provides the molecular weight of the compound and possible ways of fragmentations occurs in the compound. Thermal stability of the crystal was also studied by both simultaneous TGA/DTA analyses. The UV-Vis-NIR spectrum shows a good transparency in the whole of Visible and as well as in the near IR range. Third order nonlinear optical studies have also been studied by Z-scan technique. Nonlinear absorption and nonlinear refractive index were found out and the third order bulk susceptibility of compound was also estimated. The results have been discussed in detail.

An improved block matching algorithm for fast motion estimation (고속 움직임 추정을 위한 개선된 블록 정합 방식)

  • 문용호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.5C
    • /
    • pp.539-547
    • /
    • 2003
  • According to the PDE scheme, it is desirable to make the value of SAD to be rapidly increased in motion estimation. In this paper, we propose a new block matching algorithm based on the combination of a new scan and search order. In the proposed scan order, a current block is divided by the frequency that is estimated by summing the difference between the mean and the values of the pixels. And then the calculation of SAD is performed from the highest frequency area. In the proposed search order based on DC difference between the current and the candidate block, candidate blocks with low DC are early checked in motion estimation. Simulation results show that the proposed method achieves about 6% computational gain compared with the conventional methods.