Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change (진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향)

  • Choi, Kwanyong;Lim, Hyun Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

A Study of the Discharge Characteristics of AC-PDP Having Auxiliary Electrodes (보조전극을 가진 AC-PDP cell구조의 방전특성 연구)

  • Kang, Kyung-Il;Jang, Jin-Ho;Choi, Jun-Young;Kim, Dong-Hyun;Lee, Ho-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.173-174
    • /
    • 2007
  • 본 논문에서는 scan 전극과 common 전극 사이에 보조 전극을 가진 PDP에서 asymmetry, long gap mode 와 같은 새로운 구동방법을 제안한다. asymmetry mode에서 주전극의 가운데 부분에 위치한 보조전극은 리셋, 어드레스, 서스테인의 모든 구간동안 scan 또는 common 전극에 연결되어 있다. long gap mode에서는 전기적으로 끊어져있거나 초기 몇 개의 서스테인 펄스를 제외하고 서스테인 구간동안 Vs/2의 전압으로 유지된다. 제안된 조와 구동 방법에서 전력에너지소비를 최소화함으로써 더 높은 발광효율을 얻을 수 있다. 새로운 구동방법의 효용은 다양한 Xe분압상태에서도 연구되었다.

  • PDF

Low Power Consumption Scan Driver Using Depletion-Mode InGaZnO Thin-Film Transistors (공핍 모드 InGaZnO 박막 트랜지스터를 이용한 저소비전력 스캔 구동 회로)

  • Lee, Jin-Woo;Kwon, Oh-Kyong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.2
    • /
    • pp.15-22
    • /
    • 2012
  • A low power consumption scan driver using depletion-mode n-type InGaZnO thin-film transistors is proposed. The proposed circuit uses 2 clock signals and generates the non-overlap output signals without the additional masking signals and circuits. The power consumption of the proposed circuit is decreased by reducing the number of the clock signals and short circuit current. The simulation results show that the proposed circuit operates successfully when the threshold voltage of TFT is varied from -3.0V to 1.0V. The proposed scan driver consumes 4.89mW when the positive and negative supply voltage is 15V and -5V, respectively, and the operating frequency is 46KHz on the XGA resolution panel.

GC/MS and its applications for the analysis of cosmetic produtcts (GC/MS와 화장품 분석의 응용)

  • 노경원
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-19
    • /
    • 1993
  • Gas chromatography serves to separate the mixtures into its components, and mass spectrometer is used to analyzing of unknown compounds. But there are many problems the identification of horn compounds using by GC only. As this reason GC/MS a very powerful analyzing technique. Mass spectrometer consists of 1) inlet stem 2) ion source 3) Bass filter 4) detectors and 5) data system. There are two analyzing modes in the GC/MS, those are scan and SIM(selected ion mom toping) modes. Scan mode is used when analyzing unknown compounds and SIM mode al lows the mass spectrometer to detect specific compound with very high sensitivity. As GC/MS applications for the analysis of cosmetic products, volatile compounds in lotion, earn foundation and hair color, and carbon distribution of fatty acids in soap were performed. Also as a new sample pre-treatment technique, head space sampler/GC/MS introduced in order to analyze the volatile compounds in a toothpaste.

  • PDF

Vibration Pattern Prediction through The Analysis on the Break-up Mode and the Heat Transfer Relationship of Slim Speaker Diaphragm (슬림 스피커 진동판의 분할진동 모드와 열전달 관계 분석을 통한 진동 패턴 예측)

  • Kim, Hyun-Kab;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.109-115
    • /
    • 2016
  • In this paper, In this paper, we use two methods to compare the slim speakers. That way, the diaphragm scan using laser and diaphragm photographed using a thermal imaging camera. Slim speaker has the structure of a flat plate type. Break-up mode by this characteristic is displayed in a larger size. Further, since the installation space is narrow, it has limited moving coil cooling. As a result, the break-up mode slim speakers, a significant impact on quality. In this study, try to connect the break-up mode of the diaphragm, the heat transfer mode of the diaphragm. Experiment for comparison, a two-step. The first step is to measure the divided vibration through the vibration plate scan. The second step measures the diaphragm photographed using a thermal imaging camera. Then, compare the results of both of the same frequency. Thus, comparing the heat transfer pattern and the pattern of break-up mode. Tend to be analysis of break-up mode from the pattern comparison, and document for the optimum design.

Design for Lour pouter Scan-based BIST Using Circuit Partition and Control Test Input Vectors (회로분할과 테스트 입력 벡터 제어를 이용한 저전력 Scan-based BIST 설계)

  • 신택균;손윤식;정정화
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.125-128
    • /
    • 2001
  • In this paper, we propose a low power Scan-based Built-ln Self Test based on circuit partitioning and pattern suppression using modified test control unit. To partition a CUT(Circuit Under Testing), the MHPA(Multilevel Hypergraph Partition Algorithm) is used. As a result of circuit partition, we can reduce the total length of test pattern, so that power consumptions are decreased in test mode. Also, proposed Scan-based BIST architecture suppresses a redundant test pattern by inserting an additional decoder in BIST control unit. A decoder detects test pattern with high fault coverage, and applies it to partitioned circuits. Experimental result on the ISCAS benchmark circuits shows the efficiency of proposed low power BIST architecture.

  • PDF

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

Study on the Residue Analysis of Organophosphorus and Organochlorine Pesticides with Ion Trap and Quadrupole Mass Spectrometer (Ion Trap Mass Spectrometer와 Quadrupole Mass Spectrometer를 이용한 유기인제 및 유기염소제 농약 분석에 관한 연구)

  • Rhee, Jae-Seong;Park, Hyun-Mee;Er, Yon-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.12
    • /
    • pp.902-909
    • /
    • 1995
  • Detection limit as well as calibration curves on organophosphorus pesticide(dimethoate, diazinon, parathion-methyl, fenitrothion, malathion) and BHCs were measured for evaluation of utility on qualitative or quantitative analysis of pesticides with ion Trap mass spectrometer and quadrupole mass spectrometer. As ionization source, EI and CI were adopted for qualitative analysis of pesticides by comparison of each fragmentation pattern. At the same time, the utility as trace analysis techniques through scan or selected ion monitoring(SIM) mode was evaluated. With ion trap for all pesticides, detection limit(DL, 1 ${\mu}L$ injection) on scan mode was ranged 0.008∼0.225 ng at signal to noise ratio 3. With quadrupole DL on scan mode was ranged 0.23∼3.1 ng over 0.032∼0.68 ng on SIM mode. The calibration curve with ion trap generated good linearity over 0.99 as correlation coefficient. As clean up procedure, Bio Beads S-X3 was used for the separation of oils from five organophosphorous pesticides in flour extractant showing more than 80% as recovery at most cases. In case of BHCs in jinseng with Florisil column, the recovery of pesticides has been 60% to 90%.

  • PDF

Adaptive Coefficient Scanning Based on the Intra Prediction Mode

  • Choi, Byeong-Doo;Kim, Jin-Hyung;Ko, Sung-Jea
    • ETRI Journal
    • /
    • v.29 no.5
    • /
    • pp.694-696
    • /
    • 2007
  • This letter presents an adaptive coefficient scanning method for intra mode coding in H.264. The proposed adaptive scanning uses six alternative scanning orders based on the intra prediction mode. Experimental results show that the proposed method improves the coding efficiency up to 3% compared to conventional scanning methods without additional computations.

  • PDF