• Title/Summary/Keyword: Scan body

Search Result 574, Processing Time 0.03 seconds

Drafting Method of Upper Bodice Pattern using 3-D Anthropometric Data for Elderly Women (노년 여성 3-D 입체형상 데이터를 활용한 상반신 원형 설계방법 연구)

  • Suh, Chu-Yeon;Park, Soon-Jee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.5
    • /
    • pp.846-858
    • /
    • 2008
  • This study was designed to propose a method to draft bodice block pattern from 3D body scan data. Subjects were ten elderly women in their 60's, who wear basic size(B: 94cm, W: 82cm) garment. Scanning was done using 3D whole body scanner(WB4, Cyberware). Measurements for 3D data and cross section were attained using Auto CAD, by which a upper bodice pattern for elderly women was drawn on the basis of short measured method. The results are as following: As for most items, no significant differences were shown between measurements from Martin's anthropometry and those from 3D scan data, suggesting measurement from 3D scan data could be used to draft a pattern. The drafting equations acquired were as follows; width of pattern=B/2+5.5, width of waist=W/2+3.5cm, dart amount=8cm. Dart distributions were 23%(B.P.) : 20%(front armpit) : 17%(side seam) : 18%(back armpit) : 15%(back protruded point) : 7% (center back line). Through wearing test using 5-point Likert scale, resultant pattern was evaluated as appropriate for elderly women's pattern to get over 4 point. As a result, it might be said that 3D scanning application is effective for elderly women in that it doesn't take time so much as Martin's anthropometry and that their body shape vary compared with those of young women.

The Value of Preoperative MRI and Bone Scan in Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fractures (골다공증성 척추체 압박골절에 대한 경피적 척추성형술시 자기공명영상과 골 주사 검사의 의의)

  • Kim, Se Hyuk;Lee, Wan Su;Seo, Eui Kyo;Shin, Yong Sam;Zhang, Ho Yeol;Jeon, Pyoung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.7
    • /
    • pp.907-915
    • /
    • 2001
  • Objective : Percutaneous vertebroplasty is often complicated by the presence of multiple fractures or non-localizing pain in the patients with osteoporotic vertebral fractures. The purpose of this study is to estimate the value of preoperative radiologic studies in the localization of symptomatic vertebrae and to determine the factors which can influence on the clinical results. Materials and Methods : We retrospectively reviewed the clinical and radiologic data of 57 vertebrae in 30 patients underwent percutaneous vertebroplasty for osteoporotic vertebral compression fractures. Inclusion criteria was severe pain(McGill-Melzack score 3, 4 or 5) associated with the acute vertebral fractures and absence of spinal nerve root or cord compression sign. Acute symptomatic vertebral fracture was determined by the presence of signal change on MR images or increased uptake on whole body bone scan. Results : Pain improvement was obtained immediately in all patients and favorable result was sustained in 26 patients(86.7%) during the mean follow-up duration of 4.7 months(5 complete pain relief, 21 marked pain relief). Those who underwent vertebroplasty for all acute symptomatic vertebrae had significantly better clinical result than those who did not. Further vertebral collapse and eventual bursting fracture occurred in 1 vertebra which showed intradiskal leakage of bone cement and disruption of cortical endplate on postoperative CT scan. Conclusion : Preoperative MR imaging and whole body bone scan are very useful in determining the symptomatic vertebrae, especially in the patients with multiple osteoporotic vertebral fractures. To obtain favorable clinical result, the careful radiologic evaluation as well as clinical assessment is required. Control of PMMA volume seems to be the most critical point for avoiding complications.

  • PDF

The Qualitative Study on the Evaluation and the Application of 3D scan and virtual try-on technology (3차원 스캔과 가상 착의 기술의 평가와 활용에 관한 질적연구)

  • Choi, Young-Lim;Nam, Yun-Ja
    • The Korean Fashion and Textile Research Journal
    • /
    • v.11 no.3
    • /
    • pp.437-444
    • /
    • 2009
  • According to the activation of the fashion electronic commerce, this research investigated the merits and demerits and improvement plan of the 3D virtual try-on technology using the qualitative research method. This research was performed by interview with 70 evaluation group. The evaluation group of 3D virtual try-on was organized and the fit evaluation process by 3D human body scan and the 3D virtual try-on of the i-Fashion technology center were experienced. This study was performed by interview after the actual and virtual try-on about the casual shirt. The convenience and accuracy of measurement, usability in online shopping, body evaluation, complement of sizing system, and body shape management were discovered as merits. The requirement of high accuracy in sizing and avatar, limits of fabric expression, practical limitation by cost, vexatious of measurement garment, differences between real and virtual fittings, personal information leakage risk, and etc were pointed out as demerits. The mass customization, customized garment connected with medical service, humanized avatar, improved fitting report, entertainment, coordination, wardrobe manager were proposed as improvement plan.

Height-Based Formula Predicting Renal Length in Korean Children derived from Technesium-99m Dimercaptosuccinic Acid Scan

  • Cho, Myung Hyun;Yoo, Ha Yeong;Kwak, Byung Ok;Park, Hye Won;Chung, Sochung;Kim, Soo Nyung;Son, Jae Sung;Kim, Kyo sun
    • Childhood Kidney Diseases
    • /
    • v.19 no.2
    • /
    • pp.131-135
    • /
    • 2015
  • Purpose: The aim of this study was to establish a simple formula to predict renal length in children using a Technesium-99m dimercaptosuccinic acid (DMSA) scan data, and to compare it with the formula derived from ultrasonography, which is widely accepted. Methods: Children who underwent a DMSA scan and ultrasonography were reviewed retrospectively, and those who had anatomical urinary tract abnormalities or urinary tract infections were excluded. Results: A total of 230 children (84 males and 146 females; age, 1 month to 16 years; mean age, $16.8{\pm}27.4$ months). Mean renal length measured by DMSA scan was longer than that by ultrasonography ($6.38{\pm}1.16$ vs. $6.02{\pm}1.14cm$; P < 0.001). Renal length was correlated with age, weight, height, and body surface area on the DMSA scan and ultrasonography, and showed the strongest positive correlation with height. The following formulae were established to predict renal length: mean renal length (cm) = 5.433 ${\times}$ height (m) + 2.330 (R2, 0.833) using the DMSA scan data, and mean renal length (cm) = 5.367 ${\times}$ height (m) + 2.027 (R2, 0.853) using ultrasonography data. Conclusion: We propose a simple height-based formula to predict renal length in children using a DMSA scan data, and validate it by comparing with ultrasonography formula.

Body Shape Variations Measurements with 3D Scanner for Wearing Foundation (3D Scanner를 이용한 foundation 착용시의 인체 변화 계측)

  • Park, Ji-Eun;Kim, Hee-Eun
    • The Korean Fashion and Textile Research Journal
    • /
    • v.9 no.6
    • /
    • pp.651-657
    • /
    • 2007
  • This study was carried out to analyse body configuration and to observe any space between skin and foundation. A special 3D scanner was used to analyze this foundation. Experimental foundations were brassiere, girdle, and all-in-one. Four subjects volunteered, each subject was scanned while wearing foundation and not wearing foundation. Body shape variations were analyzed with an Auto CAD and ScanWax program which analyzes cross section of the skin surface to look for any changes. Height was increased all parts of body, circumference was increased in breast and bust while wearing the foundation. The hip thickness was not increased with wearing the foundation. Therefore this foundation makes people have a different appearance due to unexpected body shape variations. The effects of this foundation should be classified by observing height, circumference, and thickness changes in the body.

Sine Scan Inhomogeneity Field Mapping using Multiple Echo (다중 Echo를 이용한 Single Scan Inhomogeneity Field Mapping)

  • Kim, C.Y.;Han, S.Y.;Jung, K.W.;Oh, C.H.;Yi, Y.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.307-308
    • /
    • 1998
  • In this paper, we describe a field measurement technique using multiple gradient echo method. For this purpose, 3 differential phase map is used between two images obtained in a single scan. The phase map is further processed to unfold phase folding (2n $\pi$). The inhomogeneity map is used to correct image distortion along readout gradient direction. Some experimental results obtained at 1.0 Tesla whole body MR system are shown with the proposed technique.

  • PDF

Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System (Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

Investigation of NESDIS's Calibration Algorithm of the Imagers for IR Channels on GOES-12

  • Chang, Ki-Ho;Oh, Tae-Hyung;Ahn, Myung-Hwan;Cho, Nam-Seo;Oh, Sung-Nam
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.1
    • /
    • pp.55-58
    • /
    • 2007
  • The prototype radiometric calibration algorithm of the imagers for IR channels has been developed according to the Weinreb's method. Applying the algorithm to the GOES-12 count data, we have shown that the calibration coefficients (slope and intercept) evaluated by the algorithm gives good agreement with the NESDIS's ones, and that the scanning error due to the scan mirror emissivity and stripe error are almost eliminated by the East/West angle dependent scan-mirror correction and the respective calculation of intercept for each North/South scan line, respectively.

Usefulness of 3-Dimensional Body Surface Scanning in the Evaluation of Patients with Pectus Carinatum

  • Song, Seung Hwan;Kim, Chong Hoon;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.301-305
    • /
    • 2020
  • Background: Radiographic modalities have been commonly used to evaluate pectus carinatum (PC), and compressive orthotic bracing is the most widely accepted treatment method. The aim of this study was to determine the efficacy of 3-dimensional (3D) body surface scanning as an alternative modality for the evaluation of PC. Methods: The medical records of 63 patients with PC who were treated with compressive orthotic bracing therapy between July 2017 and February 2019 were retrospectively analyzed. Using both 2-view chest radiography (posteroanterior and lateral view) and 3D body scanning, the height of maximal protrusion of the chest wall was measured both before and after 2 weeks of bracing therapy. The difference between the pre- and post-treatment measurements was calculated for both modalities, and these differences were compared and analyzed. Results: Based on the comparison between the pre- and post-treatment radiographs, bracing therapy produced favorable outcomes in all patients (p<0.001). The measurements obtained via 3D scanning were strongly correlated with those obtained via chest radiography (r=0.60). Conclusion: Based on the findings of this study, 3D body surface scanning appears to be an effective, radiation-free, and simple method for the post-treatment follow-up evaluation of PC, and thus can be considered an alternative to radiography.

Analysis of Cross Sectional Ease Values for Fit Analysis from 3D Body Scan Data Taken in Working Positions

  • Nam, Jin-Hee;Branson, Donna H.;Ashdown, Susan P.;Cao, Huantian;Carnrite, Erica
    • International Journal of Human Ecology
    • /
    • v.12 no.1
    • /
    • pp.87-99
    • /
    • 2011
  • Purpose- The purpose of this study was to compare the fit of two prototype liquid cooled vests using a 3D body scanner and accompanying software. The objectives of this study were to obtain quantitative measurements of ease values, and to use these data to evaluate the fit of two cooling vests in active positions and to develop methodological protocol to resolve alignment issues between the scans using software designed for the alignment of 3D objects. Design/methodology/approach- Garment treatments and body positions were two independent variables with three levels each. Quantitative dataset were dependent variables, and were manipulated in 3x3 factorial designs with repeated measures. Scan images from eight subjects were used and ease values were obtained to compare the fit. Two different types of analyses were conducted in order to compare the fit using t-test; those were radial mean distance value analysis and radial distance distribution rate analysis. Findings- Overall prototype II achieved a closer fit than prototype I with both analyses. These were consistent results with findings from a previous study that used a different approach for evaluation. Research limitations/implications- The main findings can be used as practical feedback for prototype modification/selection in the design process, making use of 3D body scanner as an evaluation tool. Originality/value- Methodological protocols that were devised to eliminate potential sources of errors can contribute to application of data from 3D body scanners.