• Title/Summary/Keyword: Scan Delay Time

검색결과 74건 처리시간 0.024초

Which Factors Related to the Renal Cortical Defects in Infants Under 3 Months of Age with Urinary Tract Infections?

  • An, Yu Kyung;Cho, Myung Hyun;Kim, Kyo Sun
    • Childhood Kidney Diseases
    • /
    • 제20권2호
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: We used technetium-99m dimercaptosuccinic acid (DMSA) scintigraphy to identify factors predictive of renal cortical defects in infants <3 months of age with urinary tract infections (UTIs). Methods: We retrospectively reviewed data on infants <3 months of age with culture-proven UTIs treated at a single center from March 2010 to February 2016. Blood samples were obtained for laboratory evaluation prior to commencement of antibiotic therapy. The therapeutic delay time (TDT) and therapeutic response time (TRT) were recorded. All patients were divided into two groups depending on features of their DMSA scans. We compared the demographic, clinical, and laboratory characteristics of the two groups. Results: A total of 119 infants (94 males and 25 females; mean age, $56.9{\pm}21.3days$) were included. Cortical defects were evident in the DMSA scans of 47 cases (39.5%). In infants with such defects, the peak temperatures ($38.9{\pm}0.57^{\circ}C$ vs. $38.4{\pm}0.81^{\circ}C$, P=0.001), the absolute neutrophil counts ($8,920{\pm}4,460/mm$ vs. $7,290{\pm}4,090/mm$, P=0.043), and the C-reactive protein (CRP) levels ($6.49{\pm}4.33mg/dL$ vs. $3.21{\pm}2.81mg/dL$, P=0.001) were significantly higher than those in infants without cortical defects. The TDT was also longer in those with cortical defects (P=0.037). Conclusion: We found that a TDT ${\geq}8.5hr$ (odds ratio [OR] 5.81), a peak temperature ${\geq}38.3^{\circ}C$ (OR 6.19), and a CRP level ${\geq}4.96mg/dL$ (OR 7.26) predicted abnormal DMSA scan results in infants <3 months of age with UTIs.

췌장암 환자의 양전자방출단층촬영(PET) 검사 시 혈당치와 영상에 관한 분석 (Comparison of Blood Glucose Level in Pancreatic Cancer on $^{18}F$-FDG PET)

  • 오신현;이승재;박훈희;박용성;강천구;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.65-69
    • /
    • 2011
  • 양전자방출단층촬영 검사 시 정상 췌장의 FDG 섭취가 낮으며, 췌장암은 높은 FDG 섭취를 보이는 종양이므로 PET을 이용하여 췌장 병변의 악성 여부를 진단할 수 있다. 그러나 췌장암 환자에서 당뇨병의 유병률이 높다는 것은 여러 보고에서 잘 알려져 있고, 혈당의 수치가 정상 범위 이상인 경우엔 FDG 섭취가 감소하게 된다. 그러므로 혈당의 수치를 정상 범위로 조절하기 위해 검사를 지연시켜 환자의 불편함 뿐만 아니라 검사 일정 조정에도 지장을 초래 한다. 본 연구에서는 PET 검사 시 췌장암 환자의 혈당치가 영상에 미치는 영향을 평가하였다. 본 연구는 PET 검사를 위해 본원 핵의학과에 내원한 100명의 환자를 대상으로 하였다. 검사 직전 공복 혈장 포도당농도를 측정하여 당뇨병을 진단받은 환자군과 진단받지 않은 환자군으로 분류하였다. 영상분석은 당뇨병을 진단받지 않은 환자군, 당뇨병을 진단받은 환자군 중 7.0 mmol/L (126 mg/dL) 이상 그리고 미만인 세 그룹의 간과 폐에 관심영역(ROI)을 설정하고 최대 표준화 섭취 계수 ($SUV_{max}$)를 구하여 SPSS ver. 17을 이용하여 비교 분석하였다. 100명의 환자 중 남자 53명, 여자 47명이었고 평균 연령은 $60.1{\pm}13.5$세였다. 췌장암과 당뇨병이 같이 있는 환자들이 36명(남 22명, 여 14명)으로 36%였다. 또 검사 직전 공복 혈장 포도당농도가 7.0 mmol/L 이상인 환자는 100명 중 15명, 미만인 환자는 85명이었다. 당뇨병을 진단받은 환자군 중 7.0 mmol/L 이상, 미만, 당뇨병 진단을 받지 않은 그룹 간의 간과 폐에서의 $SUV_{max}$는 유의한 차이가 없었다(p>0.05). 결론적으로 췌장암 환자의 당뇨병 유병율이 높았고, PET 검사 시 공복 혈당치가 정상 혈당치보다 높아도 검사 전처치가 잘되어 있으면 영상을 진단하는데 큰 어려움을 주지 않을 것이라 생각된다. 또한 혈당치 조절을 위한 검사실 일정 조정에 변화를 주지 않을 뿐만 아니라, 추가적인 공복 기간으로 오는 불편함을 줄일 수 있을 것이라 사료된다.

  • PDF

Etching characteristics of Al-Nd alloy thin films using magnetized inductively coupled plasma

  • Lee, Y.J.;Han, H.R.;Yeom, G.Y.
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 1999년도 추계학술발표회 초록집
    • /
    • pp.56-56
    • /
    • 1999
  • For advanced TFT-LCD manufacturing processes, dry etching of thin-film layers(a-Si, $SiN_x$, SID & gate electrodes, ITO etc.) is increasingly preferred instead of conventional wet etching processes. To dry etch Al gate electrode which is advantageous for reducing propagation delay time of scan signals, high etch rate, slope angle control, and etch uniformity are required. For the Al gate electrode, some metals such as Ti and Nd are added in Al to prevent hillocks during post-annealing processes in addition to gaining low-resistivity($<10u{\Omega}{\cdot}cm$), high performance to heat tolerance and corrosion tolerance of Al thin films. In the case of AI-Nd alloy films, however, low etch rate and poor selectivity over photoresist are remained as a problem. In this study, to enhance the etch rates together with etch uniformity of AI-Nd alloys, magnetized inductively coupled plasma(MICP) have been used instead of conventional ICP and the effects of various magnets and processes conditions have been studied. MICP was consisted of fourteen pairs of permanent magnets arranged along the inside of chamber wall and also a Helmholtz type axial electromagnets was located outside the chamber. Gas combinations of $Cl_2,{\;}BCl_3$, and HBr were used with pressures between 5mTorr and 30mTorr, rf-bias voltages from -50Vto -200V, and inductive powers from 400W to 800W. In the case of $Cl_2/BCl_3$ plasma chemistry, the etch rate of AI-Nd films and etch selectivity over photoresist increased with $BCl_3$ rich etch chemistries for both with and without the magnets. The highest etch rate of $1,000{\AA}/min$, however, could be obtained with the magnets(both the multi-dipole magnets and the electromagnets). Under an optimized electromagnetic strength, etch uniformity of less than 5% also could be obtained under the above conditions.

  • PDF

MTF measuring method of TDI camera electronics

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Yong, Sang-Soon;Choi, Hae-Jin
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.540-543
    • /
    • 2007
  • The modulation transfer function (MTF) in a camera system is a measurement of how well the system will faithfully reproduce the original scene. The electro-optical camera system consists of optics, an array of pixels, and an electronics which is related to the image signal chain. The system MTF can be cascaded with each element's MTF in the frequency domain. That is to say, the electronics MTF including the detector MTF can be recalculated easily by the acquired system MTF if the well-known test optics is used in the measuring process. A Time-Delay and Integration (TDI) detector can make a signal increase by taking multiple exposures of the same object and adding them. It can be considered the various methods to measure the MTF of the TDI camera system. This paper shows the actual and practical MTF measuring methods for the detector and electronics in the TDI camera. The several methods are described according to the scan direction as well as the TDI stages such as the single line mode and the multiple-lines mode. The measuring is performed in the in the static condition or dynamic condition to get the point spread function (PSF) or the line spread function (LSF). Especially, the dynamic test bench is used to simulate on track velocity to synchronize with TDI read out frequency for the dynamic movement.

  • PDF

소형 CW Sub-THz 이미징 시스템을 이용한 물체의 비파괴 이미징 (Nondestructive Imaging of an Object Using the Compact Continuous-Wave Sub-Terahertz Imaging System)

  • 장진석;권일범;윤동진;서대철
    • 비파괴검사학회지
    • /
    • 제30권4호
    • /
    • pp.352-358
    • /
    • 2010
  • 전기적인 장치를 기반으로 한 테라헤르츠 송신기(terahertz transmitter; Tx)를 이용하여 0.34 THz의 전자기파를 발생시키는 소형 CW sub-THz 이미징 시스템을 제시하였다. Tx에 의해 발생된 0.34 THz의 전자기파를 point by point 스캔방식으로 샘플에 투과시켰고, 여기서 얻어진 데이터는 테라헤르츠 수신기(terahertz receiver; Rx)를 이용하여 진폭(magnitude)과 위상(phase) 정보로 측정한 후 이를 영상화하였다. 이 논문에서는 보다 좋은 이미지 해상도를 얻기 위하여 데이터 수집 시 이미지의 분해능(resolution)에 영향을 미치는 주사 스테이지(scanning stage)의 시간지연과 스텝거리를 변수로 두어 다양한 샘플들을 주사하여 그 결과를 측정, 비교하였다. 또한 플라스틱, 종이, 나무 등 다양한 샘플들의 이미징 측정을 통해 테라헤르츠 파의 응용 가능성을 확인하였다.

GPS정보를 이용한 위치기반 핸드오프 시스템의 설계 및 구현 (Design and Implementation of Geographical Handoff System Using GPS Information)

  • 한승호;양승철;김종덕
    • 한국통신학회논문지
    • /
    • 제35권1A호
    • /
    • pp.33-43
    • /
    • 2010
  • 최근 사용자들은 IEEE 802.11 무선랜이 탑재된 이동단말을 통해 인터넷, VoIP등과 같은 실시간 멀티미디어 서비스를 받고자 한다. 넓은 지역에서의 이동성을 지원하기 위하여 액세스포인트간의 핸드오프는 필수적이다. 하지만 기존 IEEE 802.11의 핸드오프 방식은 연결의 단절이 발생하며, 연결단절 인지와 채널 검색시간이 대부분의 지연시간을 차지하고 있다. 또한 노드의 이동방향, 위치 등을 고려하지 않고 주위 환경에 민감한 신호 세기만 고려하여 액세스포인트를 선택하기 때문에 충분한 대역폭을 받기 힘들다. 그렇기 때문에 실시간 멀티미디어 서비스를 제공하기 위하여 노드의 연결단절시간을 줄이고 충분한 대역폭을 받을 수 있는 알고리즘이 필요하다. 이에 본 논문에서는 실외환경에서 사용하는 GPS 위치정보를 이용하여 노드의 이동에 따른 핸드오프 지점을 예측하고, 이동방향, 속도와 신호세기를 이용하여 높은 전송 대역폭을 받는 핸드오프 알고리즘을 제안한다. 제안한 알고리즘을 구현하고 성능평가를 통하여 Layer2의 연결단절시간을 3.7ms로 줄이고 약 24.8%의 대역폭 향상을 통해 알고리즘의 우수함을 확인했다.

Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해 (Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases)

  • 류영환;구은회;정재은;동경래;최성현;이재승
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

Optimization of the Flip Angle and Scan Timing in Hepatobiliary Phase Imaging Using T1-Weighted, CAIPIRINHA GRE Imaging

  • Kim, Jeongjae;Kim, Bong Soo;Lee, Jeong Sub;Woo, Seung Tae;Choi, Guk Myung;Kim, Seung Hyoung;Lee, Ho Kyu;Lee, Mu Sook;Lee, Kyung Ryeol;Park, Joon Hyuk
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: This study was designed to optimize the flip angle (FA) and scan timing of the hepatobiliary phase (HBP) using the 3D T1-weighted, gradient-echo (GRE) imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique on gadoxetic acid-enhanced 3T liver MR imaging. Materials and Methods: Sixty-two patients who underwent gadoxetic acid-enhanced 3T liver MR imaging were included in this study. Four 3D T1-weighted GRE imaging studies using the CAIPIRINHA technique and FAs of $9^{\circ}$ and $13^{\circ}$ were acquired during HBP at 15 and 20 min after intravenous injection of gadoxetic acid. Two abdominal radiologists, who were blinded to the FA and the timing of image acquisition, assessed the sharpness of liver edge, hepatic vessel clarity, lesion conspicuity, artifact severity, and overall image quality using a five-point scale. Quantitative analysis was performed by another radiologist to estimate the relative liver enhancement (RLE) and the signal-to-noise ratio (SNR). Statistical analyses were performed using the Wilcoxon signed rank test and one-way analysis of variance. Results: The scores of the HBP with an FA of $13^{\circ}$ during the same delayed time were significantly higher than those of the HBP with an FA of $9^{\circ}$ in all the assessment items (P < 0.01). In terms of the delay time, images at the same FA obtained with a 20-min-HBP showed better quality than those obtained with a 15-min-HBP. There was no significant difference in qualitative scores between the 20-min-HBP and the 15-min-HBP images in the non-liver cirrhosis (LC) group except for the hepatic vessel clarity score with $9^{\circ}$ FA. In the quantitative analysis, a statistically significant difference was found in the degree of RLE in the four HBP images (P = 0.012). However, in the subgroup analysis, no significant difference in RLE was found in the four HBP images in either the LC or the non-LC groups. The SNR did not differ significantly in the four HBP images. In the subgroup analysis, 20-min-HBP imaging with a $13^{\circ}$ FA showed the highest SNR value in the LC-group, whereas 15-min-HBP imaging with a $13^{\circ}$ FA showed the best value of SNR in the non-LC group. Conclusion: The use of a moderately high FA improves the image quality and lesion conspicuity on 3D, T1-weighted GRE imaging using the CAIPIRINHA technique on gadoxetic acid, 3T liver MR imaging. In patients with normal liver function, the 15-min-HBP with a $13^{\circ}$ FA represents a feasible option without a significant decrease in image quality.

소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 - (Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography -)

  • 이희정;손순룡;이원홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.279-286
    • /
    • 2005
  • 목 적 : 소장조영술과 복부골반 CT검사의 진단 결과를 비교함으로써 방사선학적 영상의 특징 파악 및 질환에 따른 적절한 방사선학적 검사법을 선택하는데 기초자료를 제공하고자 한다. 대상 및 방법 : 1999년부터 2000년까지 소장조영술과 복부골반 CT검사를 병행하여 시행한 환자 284명을 대상으로 하여, 각각의 진단 소견을 병명별로 분류하였다. 소장조영술은 250 ml 황산바륨 현탁액(W/V 40W/V%, Methylcellulose+$BaSo_4$)을 경구로 복용시키고, Rt. recumbent position을 취하게 한 후 약 10분 후에 Carboxymethylcellulose solution(0.5%) 600 ml 복용시켰다. 20분, 40분, 1시간 정규촬영을 하고, 조영제가 회맹판(I-C valve)을 통과하면 투시 하에 저격촬영을 시행하였다. 복부골반전산화단층촬영은 검사 1시간 전에 $BaSO_4$+Methylcellulose 1.5 W/V% 450 ml를 복용시키고 검사직전 450 ml 추가로 복용시켰다. 요오드 성분의 비이온성 조영제 2.5 ml flow/sec로 주입하고, 조영제 주입 후 72초 지연 촬영을 하였다. 촬영은 간 상연에서부터 치골결합 부위까지 continuous scan을 시행하였으며, 검사 protocol은 Helical thick 5 mm, picth 1.375 : 1, speed 27.50, increment 5 mm, 120 kV, 245 mA로 하였다. 결 과 : 소장조영술에서는 정상(Normal)이 131예(46.1%), 감염성 장질환(Inflammatory bowel disease ; 이하 IBS)이 65예(22.9%), ischemia+ileocolitis+vasculitis 22예(7.7%), obstruction+stricture 21예(7.4%)의 순으로 나타났고, 복부골반 CT검사에서는 정상이 103예(36.3%) IBS가 65예(22.9%), wall thickening+lymphadenopathy가 42예(14.8%), fluid collection이 17예(6%)의 순으로 나타났다. 소장조영술과 복부골반 CT검사에서 동일하지 않은 결과로 진단된 경우는 소장조영술에서 정상으로 진단된 132명(46.1%) 중 14예(10.6%), 복부골반 CT검사 결과에서는 wall thickening+lymphadenopathy와 IBS로 진단되어 차이를 보였으며, 복부골반 CT검사 결과 정상으로 진단된 103예(36.3%) 중 5예(5.8%)가 소장조영술에서 ischemia+ileocolitis+vasculitis로 진단되었다. 정상으로 진단 된 235예 중 37예(15.9%)가 서로 다른 결과로 진단되어 통계적으로 유의한 차이를 보였다(P<0.05). 결 론 : 본 연구에서 특정질환에 특정검사의 진단결과가 우수하게 나타나는 것으로 조사되었으므로 방사선학적 검사의 진단적 민감도를 높이기 위해서는 처방 및 검사에 있어서 질환에 따른 적절한 검사법의 선택이 무엇보다도 중요하리라 사료된다.

  • PDF

원발성 악성기관종양의 임상적 고찰 (A Clinical Review of Primary Tracheal Carcinoma)

  • 류정선;조현명;양동규;이홍렬;김세규;장준;안철민;신계철;김성규;이원영
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권4호
    • /
    • pp.766-775
    • /
    • 1997
  • 연구배경 : 원발성 악성기관종양은 매우 드문 질환으로 모든 호흡기 종양의 0.1% 정도 차지하는 것으로 되어 있으며 매우 드물게 보고가 있어 왔다. 원발성 악성기관종양을 의심할 만한 특이 증상, 신체검사 소견이 없으며 흉부 X-선 상에서도 정상으로 보이는 경우가 많아 상당 기간을 폐쇄성 폐질환 또는 기관지 천식 등으로 치료 받게되어 기관종양에 대한 의심을 하지않을 경우 진단에 어려움이 많으며 적극적인 치료시기를 놓치는 수가 많다. 방 법 : 1981년 1월부터 1995년 12월까지 연세의료원, 영동세브란스병원과 원주기독병원에 입원하였던 환자중 원발성 악성기관종양으로 진단된 17예를 대상으로 후향적 연구를 하였으며 기관내 종양의 발병위치, 흡연력과 호흡기증상 등 입상양상, 내원 당시 흉부 X-선 판독 결과, 내원 후 시행한 객담 세포진 검사 및 환자가 처음으로 의료기판에 방문해서 부터 원발성 악성기관종양으로 진단되기까지의 기간, 내원 당시 초진진단명 및 치료에 따른 생존기간을 관찰하였다. 결 과 : 50세를 기준으로 하여 종양의 발생 빈도를 보면 편평상피세포암의 9예중 8예(88%)가 50세 이상에서, 경우 6예중 5예(83%)가 50세 미만에서 발생하였다. 편평상피세포암의 경우 전 예가 남자에서 관찰 되었으며 전 예에서 흡연력이 있었다. 원주종 6예 중 여자가 5예 이었다. 기관내 발생 위치는 상부 $\frac{1}{3}$이 17예 중 8예(47%)로 제일 많았다. 임상 양상은 호흡곤란이 13예(76%)로 제일 많았으며 그 다음으로는 천명음, 기침, 가래 등의 순이었다. 내원 당시 흉부 X-선 판독 결과 15예중 1예에서만 기관종양으로 판독되었으며 객담 세포진 검사에서는 12예중 1예에서만 악성 종양세포가 관찰 되었다. 진단 되기까지의 기간은 원주종의 경우 평균 24.9개월이었고 편평상피세포암의 경우 5개월 이었다. 내원 당시 진단으로는 천식이 8예(47%)로 제일 많았으며 기관종양을 의심하였던 경우는 4예(23%) 이었다. 결 론 : 원인이 불분명한 객혈 및 쉰 목소리, 흡기성 천명음, 체위 변동에 따른 호흡곤란의 악화, 기관지 천식의 치료에 반응이 없는 경우 등의 비특이적인 기관지 천식의 임상양상을 갖는 경우 기관의 폐쇄성 병변을 의심하여야 하며 흉부 X-선 촬영시 높은 관전압의 사용과 지관지경등 적극적인 진단수기를 시행하여야 하며 원발성 악성기관종양으로 진단되면 가능한 한 근치적 절제술을 시도하고 근치적 수술이 어려운 경우 60Gy 이상의 외부 방사선 치료를 시행함이 바람직 할 것으로 생각된다.

  • PDF