• Title/Summary/Keyword: Scalp tumor

Search Result 65, Processing Time 0.026 seconds

Surgical refinement of the purse-string suture for skin and soft tissue defects of the head and neck

  • Park, Hyochun;Lee, Yunjae;Yeo, Hyeonjung;Park, Hannara
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.4
    • /
    • pp.183-192
    • /
    • 2021
  • Background: The purse-string suture (PSS) is a simple and rapid wound closure method that results in minimal scarring. It has been used to treat circular or oval skin defects caused by tumor excision or trauma. However, due to obscurity, it is not widely used, especially for the head and neck. This study aimed to modify the PSS to obtain predictable and acceptable results. Methods: A total of 45 sites in 39 patients with various types of skin and soft tissue defects in the head and neck were treated with PSS. We used PDS II (2-0 to 5-0), which is an absorbable suture. Minimal dissection of the subcutaneous layer was performed. The suture knot was hidden by placing it in the dissection layer. Depending on the characteristics of the skin and soft tissue defects, additional surgical interventions such as side-to-side advancement sutures, double PSS, or split-thickness skin graft were applied. Results: All wounds healed completely without any serious complications. Large defects up to 45 mm in diameter were successfully reconstructed using only PSS. Postoperative radiating folds were almost flattened after approximately 1-2 months. Conclusion: PSS is simple, rapid, and relatively free from surgical design. Owing to the circumferential advancement of the surrounding tissue, PSS always results in a smaller scar than the initial lesion and less distortion of the body structures around the wound in the completely healed defect. If the operator can predict the process of healing and immediate radiating folds, PSS could be a favorable option for round skin defects in the head and neck.

A study on the manufacturing method and usefulness of Bolus-helmet used for malignant scalp tumor patients (악성두피종양환자에게 사용되는 보루스헬멧(Bolus-helmet)의 제작방법 및 유용성에 관한 연구)

  • Lee, joung jin;Moon, jae hee;Kim, hee sung;Kim, koon joo;Seo, jung min;Choi, jae hoon;Kim, sung gi;Jang, in gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.15-24
    • /
    • 2021
  • This study is about the introduction and usefulness evaluation of the manufacturing method of the bolus-helmet. Helmet-production for the treatment of scalp tumor patients has been tried and will continue in many creative and various ways. However, Most of the research data did not significantly reduce the psychological burden and physical and physical discomfort that the patient had to bear due to the time and economic cost required for the production of the helmet, the convenience of production, and the complexity of the process. In addition, recently, studies using more advanced technologies and equipment such as 3D-printer technology, which are being studied as a way to increase the treatment effect, are being introduced, but the time, economic cost, and psychological and physical burden are still the sole responsibility of the patient. Isn't it getting worse? The reality is that the thoughts of concern cannot be erased. Therefore, by maintaining the physical properties of the bolus and manufacturing a helmet without incurring additional costs, the physical and physical discomfort aggravated to the patient was reduced and the procedure and time for helmet manufacturing were minimized. In this way, it was possible to reduce the time, economic cost, and physical discomfort required for the production of the helmet, and it was also possible to minimize the psychological burden of the patient, although it is invisible. Additionally, in evaluating the usefulness of helmets, we are able to continuously seek and develop ways to reduce the air-gap interval, and as a result, we will be able to introduce a method to keep it within 2.0mm along with the manufacturing method through this study. I feel very welcome. Finally, I hope that anyone working in the Department of Radiation Oncology will be able to easily manufacture the helmet required for radiation therapy using a bolus through the guide-line on helmet manufacturing provided by this institute. I hope and hope that if you have any questions or inquiries that arise during the production process, please feel free to contact us through the researcher's e-mail or mobile phone at any time.

Fractionated Stereotactic Radiation Therapy for Intracranial Benign Tumor : Preliminary Results of Clinical Application (양성 뇌종양의 분할정위 방사선치료 : 임상적 응용의 예비적 결과)

  • Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Choi Dong Rak;Nam Jong Hyun;Lee Jung Il;Park Kwan;Nam Do-Hyun;Kim Moon Kyung
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.185-194
    • /
    • 1998
  • Purpose : With the development of stereotactic immobilization systems capable of reliable serial repositioning, fractionated stereotactic radiation therapy (FSRT) offers the Potential for an improved treatment outcome by excellent dose delivery, and dose distribution characteristics with the favorable radiobiological properties of fractionated irradiation. We describe our initial experience using FSRT for the treatment of intracranial benign tumor. Materials and Methods : Between August 1995 and December 1996. 15 patients(7 males and 8 females aged 6-70 years) were treated with FSRT. The patients had the following diagnosis pituitary adenoma(10) including one patient who previously had received radiotherapy, craniopharyngioma (2), acoustic neurinoma (1), meningioma (2). Using the Gill-Thomas-Cosman relocatable head frame and multiple non-coplanar therapy, the daily dose of 2Gy was irradiated at 90% to 100% isodose surface of the isocenter The collimator sizes ranged from 26mm to 70mm. Results : In all patients except one follow-up lost, disease was well-controlled. Acute complication was negligible and no patient experienced cranial nerve neuropathies and radiation necrosis. In overall patient setup with scalp measurements, reproducibility was found to have mean of $1.1{\pm}0.6mm$ from the baseline reading. Conclusion : Relocatable stereotactic system for FSRT is highly reproducible and comfortable. Although the follow-up period was relatively short. FSRT is considered to be a safe and effective radiation technique as the treatment of intracranial tumor. But the fractionation schedule(fraction size, overall treatment time and total dose) still remains to be solved by further clinical trials.

  • PDF

A Retrospective Analysis of Six Cases of Angiosarcoma (6례의 Angiosarcoma 환자에 대한 경과 분석)

  • Song, Kyeong-Ho;Nam, Su-Bong;Kim, Kyoung-Hoon;Choi, Chi-Won;Oh, Heung-Chan;Choi, Soo-Jong;Bae, Yong-Chan
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.791-797
    • /
    • 2011
  • Purpose: Angiosarcoma is a rare and aggressive malignant soft tissue tumor. Due to a lack of the established optimal treatment modalities, however, an extensive resection followed by an early detection has been reported to be the best treatment of choice. We analyzed the clinical course of six patients, hence attempted to contribute to making a treatment plan for patients with angiosarcoma. Methods: Six patients who have been surgically treated between 2005 and 2010 are included. Through a retrospective analysis of the medical records, we evaluated the pattern of disease detection, a past history, time span between the detection and the primary surgery, surgical treatment modalities, time span between the primary surgery and the recurrence/metastasis, the sites of metastasis and the secondary treatment modalities. Results: The mean age of patients was 70.5 years; all male; and the sites were the scalp. Four patients underwent the reconstruction using a local flap with a skin graft and two patients using a free flap. The mean period elapsed until the primary operation since the identification was 7.3 months and until a recurrence or a metastasis occurred following the primary operation was 12 months. Four patients had pulmonary metastasis. As a secondary therapy, four patients underwent the radiotherapy and one was treated with the chemotherapy. At the present, five patients died and one undergoes a monitoring of the clinical course. Conclusion: It would be mandatory to shorten the length of hospital stay and to return patients to their daily lives as the earliest as possible using relatively simpler surgical methods, thus attempting to give them opportunity to resume their previous normal life.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF