• 제목/요약/키워드: Scale of Ventilation Efficiency

검색결과 28건 처리시간 0.026초

Dry room내 수분환기에 대한 수치적 연구 (Numerical Analysis of Moisture Ventilation in the Dry Room)

  • 이관수;임광옥;정영식
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.908-916
    • /
    • 2000
  • In this paper, the characteristics of moisture ventilation in the lithium ion battery manufacturing dry room are studied numerically using standard $k-\varepsilon$ turbulence model. Both the steady-state and the unsteady behaviors of moisture ventilation are analyzed by considering local and uniform moisture generation. In order to evaluate the characteristics of moisture ventilation, three scales of ventilation efficiency and characteristic ventilation time are presented from the numerical results. It was shown that moisture distribution was dependent strongly on the flow field. The characteristics of moisture ventilation were improved by 20% and 40% in terms of the 1st scale of ventilation efficiency (SVE1) and the 2nd scale of ventilation efficiency (SVE2), respectively, through the modifications of design variables such as the addition of inlets, outlets and partition. A significant improvement in the characteristic ventilation time and the moisture exhaust efficiency was also made by these modifications.

  • PDF

CFD해석에 의한 침실 호흡역의 환기효율 분석 (Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room)

  • 유복희;윤정숙
    • KIEAE Journal
    • /
    • 제2권3호
    • /
    • pp.11-16
    • /
    • 2002
  • Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

선박 복합 밀폐공간 내 환기효율 분석을 통한 공기환경 개선에 관한 연구 (Study on Improvement of Air Quality through Analysis of Ventilation Efficiency in Complex Enclosures of a Ship)

  • 정재훈;송두삼
    • 설비공학논문집
    • /
    • 제27권8호
    • /
    • pp.440-447
    • /
    • 2015
  • In the shipbuilding process, the confined work spaces of the ship are formed continuously; the ventilation method can therefore be limited to dilution ventilation due to the complex structure and limited opening of the confined space. Also, it is difficult to evaluate air-quality using measurement and an adequate ventilation method. CFD simulation methods are typically used in analyzing ventilation efficiency in these cases. In this study, a method is suggested to analyze the air quality of the complex enclosures in shipbuilding using CFD. Especially, among the conventional indices, the ventilation efficiency scales or indices, the supply air contribution (SVE4), and the age of the air (SVE3) (fit for the confined and complex enclosure) were applied.

극저습 공조실의 환기성능에 대한 수치적 모사 (Numerical Simulation of Ventilation Performance in a Dry Room)

  • 최석호;이관수
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.594-603
    • /
    • 2002
  • The characteristics of moisture ventilation in a dry room were studied numerically The effect of three important parameters: position of outlets, aspect ratio($\beta$) of horizontal plane and air exchange rate(N), was analyzed by using the scales of ventilation efficiency. The ventilation performance was evaluated by varying the aspect ratio and air exchange rate in the four types of outlet position. It was shown that the ventilation performance was improved by decreasing the aspect ratio in the longitudinal arrangement of outlet. The highest ventilation performance was determined when $\beta$ was 4 in the transverse arrangement of outlet. Regardless of the aspect ratio, the ceiling arrangement of outlet played more dominant effect on the ventilation efficiency than the floor arrangement. In every type and aspect ratio, the increase of air exchange rate to improve ventilation performance was appropriate up to N=60 /h.

Dry Room에서 종횡비와 배기구 위치가 환기성능에 미치는 영향 (Effect of Aspect Ratio and Location of Outlets on Ventilation Performance in a Dry Room)

  • 이관수;임광옥;최석호
    • 설비공학논문집
    • /
    • 제14권4호
    • /
    • pp.324-331
    • /
    • 2002
  • The characteristics of moisture ventilation in a dry room are studied numerically The behaviors of moisture ventilation are analyzed by varying the aspect ratio of the horizontal plane and for various positions of the outlets in the room. Three different ventilation efficiencies have been used to examine the effect of the longitudinal arrangement of outlets and transverse arrangement of outlets for each aspect ratio on ventilation inside the room. It is shown that the ventilation efficiency in the dry room can be improved by arranging the outlets transversely in the cases that the aspect ratio is less than three and longitudinally in the cases that it is greater than four.

Dry Room내 기류 및 수분오염에 관한 수치적 연구 (Numerical analysis on the flow field and moisture contamination in a dry room)

  • 이관수;임광옥;정영식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.865-870
    • /
    • 2000
  • The flow and the moisture contamination of the dry room in the manufacturing process of lithium ion battery are analyzed numerically by finite volume method. Standard ${\kappa}-{\varepsilon}$ turbulent model widely applied in predicting turbulent flow is adopted in this study. Moisture contamination and distribution are studied by assumption of two cases; one-point generation and uniform generation throughout the room. To evaluate ventilation efficiency on moisture contamination, scales of ventilation efficiency are introduced. From these analyses, moisture contamination is strongly dependent on the flow field and the radius of moisture contamination can be reduced by closing a part of outlets in a dry room.

  • PDF

도로터널 내 환기소 위치별 방재 효율에 관한 실험적 연구 (An experimental study of smoke extraction efficiency along with ventilation building location in the mad tunnel)

  • 이동호;김하영;윤찬훈;김진
    • 한국터널지하공간학회 논문집
    • /
    • 제12권3호
    • /
    • pp.215-222
    • /
    • 2010
  • 본 연구에서는 도로터널 화재 시 지하 및 지상 환기소의 방재 효율을 검토하기 위해 터널 축소모형실험을 실시하였다. 터널 모형은 Froude 상사를 기본으로 도로터널을 1/50로 축소하여 20 m의 모형 터널을 제작하였다. 방재 효율 분석에 적용된 연직갱은 설제 터널 설계시 고려된 두 가지 모형으로서 실터널 560, $280\;m^3/s$의 배연량을 1/50으로 상사하여 적용하였다. 결과로 모두 연직갱을 통한 CO 가스의 전량 배출이 가능한 것으로 분석되었다. 두 환기소의 CO 농도는 지상 환기소가 지하 환기소 보다 2.23~2.73 ppm 작게 배출되었다. 그리고 지상 환기소의 경우 터널 벽면의 냉각효과로 인해 화재 후 온도의 상승이 지하 환기소보다 $0.53{\sim}0.94^{\circ}C$ 낮게 나타났다. 이상의 축소모형 환기소 내 CO농도 및 온도변화의 분석 결과, 방재적인 측면에서 볼 때 도로터널 내 환기소의 위치는 지하보다 지상에 위치하는 것이 유리할 것으로 판단되었다.

건축물의 대공간 집회시설의 실내공기질 개선방안에 관한 연구 (A Study of the Indoor Air Quality Improvement for Large Scale Assembly Facilities)

  • 임태섭;강승모
    • 한국실내디자인학회논문집
    • /
    • 제20권4호
    • /
    • pp.183-190
    • /
    • 2011
  • Lately majority of churches have preferred to enlarge their worship area to both horizontal and vertical axis. According to expand their area which brings more devotees to the limited service area. Transform from a small church into a large church is no longer unprecedented issue in South Korea. As the size of church getting bigger, many unexpected issues become matters. One of the significant problem is that the number of people have experienced either fall a sleep or feel a doziness during their service period. Due to the limited condition for the specific building type such as religion facility(church), IAQ improvements is seriously concerned. Therefore, we are going to examine by using simulation tool, CF, a difference of ventilation efficiency about the location and number of windows, and find the best way of the ventilation efficiency in a multi-stories type church by changing the exhaust pipes location and size. Furthermore, in this thesis, by changing a ceiling height from the existing building to confirm that $CO_2$ have been satisfied for both the ventilation efficiency and IAQ.

풀화재를 이용한 터널화재 부분배연 모델실험 (Reduced-Scale Experiments of the Partial Smoke Extraction System in Tunnel Fires)

  • 이의주;유용호
    • 한국화재소방학회논문지
    • /
    • 제20권4호
    • /
    • pp.58-64
    • /
    • 2006
  • 부분배연설비를 가지고 있는 침매터널에서 화재시 배연효율을 분석하기위해 풀화재를 이용하여 축소모형실험을 수행하였다. 화재가 발생하였을 때 주위 유동이 없는 경우인 자연배연과 임계속도로 제트팬을 가동하는 강제배연의 경우에 터널내의 온도와 연소가스 농도를 측정하였다. 자연배연에 비해 강제배연은 화재발생 초기에 화원과 터널 내 기류와의 급격한 혼합에 의해 성층화 정도가 미미해지고 보다 낮은 온도를 화원주위에서 얻을 수 있었다. 이러한 급격한 혼합은 터널 상부에 위치한 부분제연 갤러리의 효율을 변화시키는데, 자연배연인 경우에 약 30%의 배연효율이 증가되었다. 일산화탄소 농도계측으로 얻어진 배연효율은 등온기체모델을 사용한 선행연구와 비교하여 거의 일치하는 결과를 얻을 수 있었다. 이러한 결과는 침매터널 화재시 승객의 안전한 대피를 위한 부분배연설비의 최적 운전방안으로 제시된다.

추적가스법을 적용한 국내 석회석 광산의 환기성능 평가 연구 (Ventilation Efficiency Evaluation of Domestic Limestone Mine Using Tracer Gas Method)

  • 김영수;노장훈;김진
    • 터널과지하공간
    • /
    • 제26권4호
    • /
    • pp.274-282
    • /
    • 2016
  • 현재 국내에서 가행 중인 석회석 광산은 자연환기력을 주된 환기방법으로 사용하고 있고, 대단면 굴착으로 매우 저속의 공기유동현상이 나타나고 있다. 이로 인하여 작업구간의 공기질이 매우 저하되어 있는 실정이다. 이러한 문제점들을 개선하기 위해서는 먼저 환기성능을 면밀하게 평가할 필요가 있다. 본 연구에서는 이러한 환기성능평가를 위해서 추적가스법을 적용하여 평가를 실시하였다. 연구 결과, 추적가스법을 통해 매우 저속의 공기유동, 공기재순환현상, 작업장 공기교환율 등을 정량적으로 평가함에 따라서 연구광산의 환기문제점들을 정밀하게 확인할 수 있었다. 이러한 추적가스법을 활용한 환기성능 평가방법은 광산의 작업환경 개선을 위하여 매우 정밀한 도구로 사용될 수 있음을 확인하였다.