• 제목/요약/키워드: Scale down test

검색결과 180건 처리시간 0.027초

축소모형실험을 통한 콘크리트 충전 FRP 합성교각의 성능 평가 (Performance Evaluation of Scale-down Concrete Filled FRP Columns)

  • 염광수;이승혜;이영호;송재준;황윤국
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권1호통권53호
    • /
    • pp.135-144
    • /
    • 2009
  • 본 연구에서는 현장타설과 프리캐스트 방식의 콘크리트 충진 FRP 교각의 성능평가 실험을 수행하였다. 8개의 축소모형 실험체에 대한 준정적 실험을 실시하였으며, 실험변수로는 FRP 두께, 콘크리트 강도, 횡방향 철근비, 직경을 선정하였다. 반복 횡하중에 대한 연성능력을 평가하고 각 시험체의 강성저하에 따른 감쇠비와 파괴양상 등을 비교하였다.

전산유체역학을 이용한 풍력터빈 축소효과 수치해석 (Numerical Analysis of Wind Turbine Scale Effect by Using Computational Fluid Dynamics)

  • 박영민;장병희
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.28-36
    • /
    • 2006
  • Numerical analysis of wind turbine scale effect was performed by using commercial CFD code, Fluent. For the numerical analysis of wind turbine, the three dimensional Navier-Stokes solver with various turbulence models was tested. As a turbulence mode, the realizable k-e turbulence model was selected for the simulation of wind turbines. To validate the present method, performance of NREL (National Renewable Energy Laboratory) Phase VI wind turbine model was analyzed and compared with its wind tunnel test and blind test data. Using the present method, numerical simulations for various size of wind tunnel models were carried out and characteristics were analyzed in detail. For wind tunnel test model, the size of nacelle may not be scaled down precisely because of available motor. The effect of nacelle size was also computed and analyzed though CFD simulation. The present results showed the good correlations in pre-stall region but much to be improved in post-stall region. In 2006 and 2007, the performance and the scale effect of standard wind turbine model will be tested in KARI(Korea Aerospace Research Institute) LSWT(Low Speed Wind Tunnel) and the present results will be validated with the wind tunnel data.

  • PDF

Uncertainty analysis of ROSA/LSTF test by RELAP5 code and PKL counterpart test concerning PWR hot leg break LOCAs

  • Takeda, Takeshi;Ohtsu, Iwao
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.829-841
    • /
    • 2018
  • An experiment was conducted for the OECD/NEA ROSA-2 Project using the large-scale test facility (LSTF), which simulated a 17% hot leg intermediate-break loss-of-coolant accident in a pressurized water reactor (PWR). In the LSTF test, core uncovery started simultaneously with liquid level drop in crossover leg downflow-side before loop seal clearing, and water remaining occurred on the upper core plate in the upper plenum. Results of the uncertainty analysis with RELAP5/MOD3.3 code clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges. For studying the scaling problems to extrapolate thermal-hydraulic phenomena observed in scaled-down facilities, an experiment was performed for the OECD/NEA PKL-3 Project with the Primarkreislaufe Versuchsanlage (PKL), as a counterpart to a previous LSTF test. The LSTF test simulated a PWR 1% hot leg small-break loss-of-coolant accident with steam generator secondary-side depressurization as an accident management measure and nitrogen gas inflow. Some discrepancies appeared between the LSTF and PKL test results for the primary pressure, the core collapsed liquid level, and the cladding surface temperature probably due to effects of differences between the LSTF and the PKL in configuration, geometry, and volumetric size.

고효율 순산소 버너의 연소 특성에 관한 실험적 연구 (Experimental study on combustion characteristics of high efficiency oxy-fuel burner)

  • 김세원;안재현;김민수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.57-64
    • /
    • 2002
  • This paper describes the results of a series of experiments executed by using two pilot-scale oxv-fuel burners are designed for maximum capacity of 50,000 kacl/hr, 300,000 kcal/hr and installed in the test furnace. The effects of turn-down ratio, excess oxygen ratio, nozzle exit velocity, injection angle, swirl vane angle and inlet oxygen temperature on the combustion characteristic are investigated. Temperature distributions are measured using R-type and Molybdenum sheathed C-type thermocouple. The results showed that maximum temperature and mean temperature increase with the increase of turn-down ratio and inlet oxygen temperature. The maximum flame temperature was increased about 35% compared to the case of equivalent air operated condition. In addition, Optimum excess oxygen ratio and nozzle characteristics are obtained for this oxy-fuel glass melting furnace.

  • PDF

향부자팔물탕으로 호전된 알코올성 다발신경병증 치험 1례 (A Case Study of Alcoholic Polyneuropathy Improved with Hyangbujapalmul-tang)

  • 최송;박혜선
    • 사상체질의학회지
    • /
    • 제35권4호
    • /
    • pp.55-64
    • /
    • 2023
  • Objectives This study was aimed to report improvement of Soeumin patient diagnosed with Alcoholic Polyneuropathy using Hyangbujapalmul-tang. Method The 41-year-old man had severe foot pain, sensory slow down and ataxic gait. The patient was diagnosed Soeumin and medicated with Hyangbujapalmul-tang three times a day. Clinical improvement was evaluated with blood test, ataxic gait evaluation, deep tendon reflex and visual analogue scale (VAS). Results The symptoms of foot pain, sensory slow down and ataxic gait were dramatically improved after treatment. Conclusions Constitutional treatment for foot pain, sensory slow down and ataxic gait diagnosed with Alcoholic Polyneuropathy are potentially effective.

발목관절 강화운동이 낙상경험이 있는 노인의 통증, 관절가동범위, 균형능력에 미치는 효과 (The Effect of Ankle Strengthening Exercise who Old Man Have fall Down Experience on Pain, ROM and Balance Ability)

  • 안목
    • 대한물리치료과학회지
    • /
    • 제18권3호
    • /
    • pp.79-86
    • /
    • 2011
  • Background : The purpose of this study was to investigate on the ankle pain, Range of Motion(ROM) and balance ability with old man have fall down experience used to ankle strengthening exercise for 6 weeks. We introduced ankle strengthening exercise in this study in order to recover the pain, ankle ROM and balance ability. Methods : Twenty-four old mans have fall down experience were included for the study. Among them, twelve old mans(experimental group) were ankle strengthening exercise and physical science methods(H/P, TENS, U/S), another twelve old mans(control group) were treated by physical science methods(H/P, TENS, U/S). Each group made use of Visual Analogue Scale(VAS) to pain and goniometer to ankle ROM and Berg Balance Test(BBS) to balance ability to compare the possible changes of pain, ROM and balance ability in two groups after treatment. Results : In experimental group, pain reduced, ankle ROM has increased in dorsi-flexion, plantar-flexion and balance ability has increased for 6 weeks. In control group, pain reduced, ankle ROM has not changed in dorsi-flextion, plantar-flextion and balance ability has not changed for 6 weeks. Conclusion : According to the results, we concluded that ankle strengthening exercise for 6 weeks is effective for reducing pain and increasing ankle ROM and balance ability. Therefore, we thought the old man have fall dawn experience need ankle strengthening exercise for prevention repeatedly fall down.

  • PDF

CANDU-6 원자로 감속재 열수력 개별영향실험을 위한 축소화 기법에 따른 1/8 축소형 HU-KINS 설계 (Design of the 1/8 Scaled HU-KINS Based on the Scaling Laws for the Experimental Investigation of Thermal-Hydraulic Effect of CANDU-6 Moderator)

  • 이재영;김만웅;김남석
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.825-833
    • /
    • 2006
  • To investigate the moderator coolability for CANDU-6 reactors, a test facility (HU-KINS) has been manufactured as a 1/8 scaled-down of a calandria tank. In the design of the test facility, a scaling law was developed in such a way to consider the thermal-hydraulic characteristics of a CANDU-6 moderator. The proposed scaling law takes into consideration of the energy conservation, the dynamic similitude such as dimensionless numbers, Archimedes number (Ar) and Reynolds number (Re), and thermal-hydraulic properties similitude. Using this proposed scaling law, the thermal-hydraulic scaling analyses of similar test facilities such as the SPEL (1/10 scale) and the STERN (1/4 scale), have been identified. As a result, in the case of the SPEL, while the energy conservation is well defined, the similarities of Ar and the heat density are not well considered. As for the similarity of the STERN, while both the energy conservation and the characteristics of Ar are well defined, the heat density is not. In the meanwhile, the HU-KINS test facility with 1/8 length scaled-down is well similitude in compliance with all similarities of the energy conservation, the fluid dynamics and thermal-hydraulic properties. To verify the adequacy of the similarities in terms of thermal-hydraulics, a computational fluid dynamic (CFD) analysis has been conducted using the CFX-5 code. As the results of the CFD analyses, the predicted flow patterns and variation of axial properties inside the calandria tank are well consistant with those of previous studies performed with FLUENT and this implies that the present scaling method is acceptable.

LMI-BASED $H_{\infty}$ LATERAL CONTROL OF AN AUTONOMUS VEHICLE BY LOOK-AHEAD SENSING

  • Kim, C.S.;Kim, S.Y.;Ryu, J.H.;Lee, M.H.
    • International Journal of Automotive Technology
    • /
    • 제7권5호
    • /
    • pp.609-618
    • /
    • 2006
  • This paper presents the lateral control of an autonomous vehicle by using a look-ahead sensing system. In look-ahead sensing by an absolute positioning system, a reference lane, constructed by straight lanes or circular lanes, was switched by a segment switching algorithm. To cope with sensor noise and modeling uncertainty, a robust LMI-based $H_{\infty}$ lateral controller was designed by the feedback of lateral offset and yaw angle error at the vehicle look-ahead. In order to verify the safety and the performance of lateral control, a scaled-down vehicle was developed and the location of the vehicle was detected by using an ultrasonic local positioning system. In the mechatronic scaled-down vehicle, the lateral model and parameters are verified and estimated by a J-turn test. For the lane change and reference lane tracking, the lateral controllers are used experimentally. The experimental results show that the $H_{\infty}$ controller is robust and has better performance compared with look-down sensing.

90 nm급 텅스텐 폴리사이드 게이트 식각공정에서 식각종말점의 안정화에 관한 연구 (A Study for Stable End Point Detection in 90 nm WSix/poly-Si Stack-down Gate Etching Process)

  • 고용득;천희곤;이징혁
    • 한국전기전자재료학회논문지
    • /
    • 제18권3호
    • /
    • pp.206-211
    • /
    • 2005
  • The device makers want to make higher density chips on the wafer through scale-down. The change of WSix/poly-Si gate film thickness is one of the key issues under 100 nm device structure. As a new device etching process is applied, end point detection(EPD) time delay was occurred in DPS+ poly chamber of Applied Materials. This is a barrier of device shrink because EPD time delay made physical damage on the surface of gate oxide. To investigate the EPD time delay, the experimental test combined with OES(Optical Emission Spectroscopy) and SEM(Scanning Electron Microscopy) was performed using patterned wafers. As a result, a EPD delay time is reduced by a new chamber seasoning and a new wavelength line through plasma scan. Applying a new wavelength of 252 nm makes it successful to call corrected EPD in WSix/poly-Si stack-down gate etching in the DPS+ poly chamber for the current and next generation devices.

쌍계사 오층석탑 실물 크기 모델의 동적 거동 시험 (Dynamic Test of a Full Scale Model of Five-Story Stone Pagoda of Sang-Gye-Sa)

  • 김재관;류혁
    • 한국지진공학회논문집
    • /
    • 제5권4호
    • /
    • pp.51-66
    • /
    • 2001
  • 1936년 7월 4일 경상남도 하동군 화개면을 진앙지로 하는 규모 5의 지진이 발생하였다. 이 지진으로 인하여 쌍계사 경내 건물과 문화재가 손상을 입었으며 금당 앞에 위치한 오층석탑의 탑두(종형석)가 추락하였다. 쌍계사 지진의 세기를 정량적으로 평가하기 위하여 철저한 고층을 거쳐서 실물크기의 석탑 모델을 제작하였다. 제작된 석탑모델을 진동대에 탑재하여 낮은 진폭에서 석탑모델의 동특성을 확인하는 예비시험과 지진파의 지진가속도를 증가시켜 가면서 석탑모델의 거동 특성을 규명하는 본 시험을 실시하였다. 석탑모델의 제작과정과 시험 절차에 관하여 상세히 기술하였고 진동대 시험 결과를 제시하고 그 결과에 관하여 논하였다.

  • PDF