액체식 제습시스템을 위한 재생기와 제습기의 높이에 따른 성능특성에 관한 연구 (Study on the Performance Characteristics with the Height of a Regenerator and Dehumidifier for Liquid Desiccant Dehumidification System)

  • 이수동;박문수;정진은;최영석
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.630-638
    • /
    • 2004
  • Liquid desiccant dehumidification systems have the ability to provide efficient humidity and temperature control while saving the electrical energy requirement for air conditioning as compared to a conventional system. The dehumidifier and the regenerator form the heart of this system. The latent part of the cooling load is overcome using liquid desiccant. The model regenerator has been designed to study the absorption characteristic of the aqueous triethylene glycol (TEG) solution which is in the flow range from 20 to 50 LPM. Also, this system designed that was able to change the height of the regenerator and dehumidifier. Because the effect of performance have different result according the height. The effect of performance factors of the regenerator with inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity have been analyzed. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.

Study of Mechanism of Counter-rotating Turbine Increasing Two-Stage Turbine System Efficiency

  • Liu, Yanbin;Zhuge, Weilin;Zheng, Xinqian;Zhang, Yangjun;Zhang, Shuyong;Zhang, Junyue
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권3호
    • /
    • pp.160-169
    • /
    • 2013
  • Two-stage turbocharging is an important way to raise engine power density, to realize energy saving and emission reducing. At present, turbine matching of two-stage turbocharger is based on MAP of turbine. The matching method does not take the effect of turbines' interaction into consideration, assuming that flow at high pressure turbine outlet and low pressure turbine inlet is uniform. Actually, there is swirl flow at outlet of high pressure turbine, and the swirl flow will influence performance of low pressure turbine which influencing performance of engine further. Three-dimension models of turbines with two-stage turbocharger were built in this paper. Based on the turbine models, mechanism of swirl flow at high pressure turbine outlet influencing low pressure turbine performance was studied and a two-stage radial counter-rotation turbine system was raised. Mechanisms of the influence of counter-rotation turbine system acting on low-pressure turbine were studied using simulation method. The research result proved that in condition of small turbine flow rate corresponding to engine low-speed working condition, counter-rotation turbine system can effectively decrease the influence of swirl flow at high pressure turbine outlet imposing on low pressure turbine and increases efficiency of the low-pressure turbine, furthermore increases the low-speed performance of the engine.

건조효율 향상을 위한 고추건조공정의 최적화 (Process Optimization of Red Pepper Drying for the Improvement of Drying Efficiency)

  • 정순경;금동혁;이동선
    • 한국식품과학회지
    • /
    • 제24권5호
    • /
    • pp.428-439
    • /
    • 1992
  • 고추건조에 대한 에너지사용의 효율성을 표현할 수 있는 건조효율 지표를 유도하고 정의하였으며 건조효율에 미치는 공정변수의 영향을 분석하고 carotenoids 보존의 제한조건하에서 건조효율을 최대화시키는 최적건조조건을 찾았다. 전체 사용에너지에 대한 증발에너지의 비로 단순화시켜서 열풍의 건구 및 습구온도의 함수로 표현된 건조효율이 건조공정중 실제의 에너지 사용의 효율성을 표현할 수 있는 것으로 확인되었고, 이를 이용하여 주어진 조건에서의 최적화가 가능하였다. 최적화 결과 1단계 건조에 비해서 2단계 건조가 같은 품질제한 조건하에서 건조효율을 증가시킬 수 있었다. 한편 배기공기 온도를 포함하는 간단한 변환변수와 건조되는 고추의 수분함량 사이의 관계에 의하여 건조시간 종료를 제어할 수 있는 가능성도 검토되었다. 전체적으로 본 연구에서 고추 건조시 좋은 품질을 유지하면서 건조효율을 향상시키고 에너지소비를 절감할 수 있는 건조기 운전의 방향을 제시하였다.

  • PDF

스마트 그리드 서비스에 대한 고객 수용도 분석 (Customer Willingness to Use Smart Grid Services in Home)

  • 김영명;이영우
    • 한국통신학회논문지
    • /
    • 제35권9B호
    • /
    • pp.1399-1406
    • /
    • 2010
  • 기존 전력망에 ICT를 접목한 스마트 그리드 환경에서 고객니즈에 기반한 수용가 서비스를 도출하기 위하여 HV, FGD 및 정량설문조사를 통해 수용가의 전기사용 추구 가치와 Unmet 니즈를 분석하였다. 연구결과, 소비자들은 전기를 가전기기 이용을 더욱 '편리'하게 해주는 존재로 인식하고, 전자파 감전 감소의 '안전'을 추구하며, 이해가 쉽고 스트레스가 적은 전기 '절약'을 원하는 것으로 조사 되었다. 그리고 전기절약을 도와주는 간편한 '기능', 전기사용량이나 전자제품의 '정보', 전기절약 유도를 위한 '동기' 유발 등에 Unmet 니즈가 존재하는 것으로 분석 되었다. 본 연구에서는 고객이 추구하는 가치와 Unmet 니즈를 반영하여 전자기기에 대한 사용량 실시간 모니터링과 제어가 가능한 홈 네트워크와 결합된 서비스로서 에너지 사용량 알리미 서비스, 대기전력 차단 서비스, 댁내 가전기기 원격제어 서비스, 에너지 컨설팅 서비스 등 4종의 스마트 홈 서비스를 도출하였다. 미래 스마트 그리드 홈 서비스 고객은 4종 서비스 모두에 60%이상의 이용의향을 보였으며 특히 에너지 사용량 알리미 서비스와 대기전력 차단 서비스에 약 80%의 이용의향을 보였다.

건축물 단열 진단을 통한 에너지 효율 개선에 관한 연구 (A Study on Energy Efficiency Improvement through Building Insulation Diagnosis)

  • 조광문
    • 사물인터넷융복합논문지
    • /
    • 제7권3호
    • /
    • pp.9-14
    • /
    • 2021
  • 본 논문에서는 주택이나 건물의 단열 진단을 통하여 에너지 손실 요인을 발견하고 이에 따른 에너지 효율 개선에 대한 방향을 제시하고 있다. 건축물의 에너지 효율 요소는 단열 진단, 열교 진단, 창호 진단, 기밀 진단, 설비 진단 등으로 구성된다. 에너지 복지 사각지대 주민 및 시설 중 전라남도 나주시에 위치한 한 경로당 건물을 대상으로 하여 에너지 효율 진단을 실시하고 단열 시공을 한 후의 에너지 효율 진단을 실시하였다. 에너지 측정과 진단 및 분석은 IoT 기반 통합 유무선 에너지 진단 플랫폼인 에너지 파인더를 이용하였다. 비교 결과 전체적으로 16.38%의 에너지 절감률을 달성하였다. 연간 단위 면적당 난방 에너지 소요량은 시공 전 333.51kWh에서 시공 후 277.35kWh로 감소되었고, 연간 단위 면적당 냉방 에너지 소요량은 시공 전 5.51kWh에서 시공 후 5.22kWh로 감소되었다. 연간 단위 면적당 1차 에너지 소요량은 시공 전 464.52kWh 였으나 시공 후 403.69kWh로 감소되었으며, 연간 에너지 사용 비용은 시공 전 3,063,307.14원이었으나 시공 후 2,641,072.49원으로 절감되었다. 단열 이외의 에너지 효율에 영향을 미치는 기준들에 대한 추가적인 개선 작업이 필요하다고 판단된다.

주거공간 내 광선반 곡률 형태에 따른 채광성능평가 연구 (Research on Lighting Performance Evaluation for Different Curvature Reflection Rate in Residential Space)

  • 오상원;이행우;김용성;서장후
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.328-336
    • /
    • 2015
  • Currently, 22% of the total energy consumption of buildings in Korea is used for lighting. Light-shelves have garnered attention as a way to reduce consumption, but there are few studies on the types of curve and curvature, which limits the improvement of light-shelf performance and its design. This study constructed a test bed of actual residential types to evaluate the performance. Outcomes of light usage, according to variables of light-shelves, were used as indicators of performance evaluation. The results are as follows:1) Performance evaluation was conducted on flat-type light-shelves to verify performance of curvature-shelves, which are movable with a width of 200 mm, and the most ideal angle and specification per solar term are calculated. 2) The (-) shaped curvature contributed to a reduction in energy consumption and an improvement of evenness. 3) In case of light-shelves with (-) shaped curvature, an increased angle not exceeding $80^{\circ}$ of the arc contributed to an improvement of light penetration. 4) Appropriate specifications of curved light-shelves include movable types with widths of 200 mm, and angle ranges of $20^{\circ}{\sim}60^{\circ}$. 5) Light energy consumption of a movable light-shelf with curvature and width of 200 mm were reduced by 17% and 7.8% compared to a $0^{\circ}$ fixed and a movable light-shelf, respectively.

지중가온이 온실의 난방부하에 미치는 영향 (The Effect of Soil Warming on the Greenhouse Heating Load)

  • 남상운
    • 한국농공학회논문집
    • /
    • 제48권5호
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.

열가소성 폴리올레핀으로 구성된 범퍼 후방 보 개발에 관한 연구 (Investigation of Development of Bumper Back-Beam Using a Thermoplastic Polyolefin)

  • 안동규;김세훈;박근성
    • 한국정밀공학회지
    • /
    • 제29권8호
    • /
    • pp.896-905
    • /
    • 2012
  • Recently, the application of the plastic material to automotive components and structures has steadily increased to satisfy demands on the saving of overall weight and the improvement of energy efficiency. The objective of this paper is to investigate the development of a bumper back-beam using a thermoplastic olefin (TPO). The bumper back-beam was designed to be manufactured from the injection molding process. In order to obtain a proper design of the bumper back-beam, three-dimensional finite element analyses were performed for various design alternatives. Stress-strain curves for different strain rates were measured by high speed tensile tests of the TPO to consider strain rate effects in the FEA. The influence of the sectional shape and the rib formation on the contact force-intrusion curves, the deflection and the energy absorption rate of the bumper back-beam was examined. From the results of the examination, a proper design of the bumper back-beam was acquired. The bumper back-beam consisting of TPO was fabricated from the injection moulding process and the vibration welding. Pendulum crash tests were carried out using the fabricated bumper back-beam. The results of the tests showed that the designed bumper back-beam can satisfy requirements of the federal motor vehicle safety standard (FMVSS). Through the comparison of the previously designed bumper back-beam with the newly designed bumper back beam, it was noted that the weight of the designed bumper back-beam is lighter than that of the previously designed bumper back beam by nearly 16 %. In addition, it was considered that the newly designed bumper back beam can improve recycling of the bumper back-beam.

섬유기반 녹화시스템 적용에 따른 노후주택의 누진세기반 전력요금 저감효과에 대한 모니터링 연구 (A Study on Monitoring the Progressive Tax-based Power Charges Reduction Effects by Applying Fiber-based Artificial Vegetation System to Obsolete Houses)

  • 김태한;이소담
    • 한국환경복원기술학회지
    • /
    • 제20권6호
    • /
    • pp.67-77
    • /
    • 2017
  • Demands for housing has diversified recently due to low birth rate and the growth of aging population. Also, a share of idle houses and obsolete houses over 20 years old is gradually rising. Therefore, there is a need for a sustainable, environment-friendly improvement policy that is in line with a new housing paradigm and avoids full-scale new construction, such as a customized housing renovation plan considering local economic circumstances. Therefore, afforestation system applicable to buildings are assessed positively, but lack objective performance evaluation. Through one-year, long-term monitoring of replicated obsolete buildings that have poor insulation performance, this study calculated monthly average power consumption and analyzed power charges by applying pricing plans before and after the revision of progressive tax in order to examine economic effects expected by applying the afforestation system. In the obsolete buildings, the study showed that monthly average power consumption was reduced by 16.6kWh with 5.2% average reduction rate. Highest reduction was made in July at 11.3%. Aggregate monthly power consumption charges were relatively high in winter before and after the revision of progressive tax. Power charges reduction effect was highest in March when monthly power consumption was reduced to 300kWh level by applying the afforestation system.

가스계 소화설비의 밀폐도 시험에 영향을 미치는 사전조치에 관한 연구: 발전소를 중심으로 (A Study on the Precautions Effects of the Enclosure Integrity Test for the Gaseous Extinguishing Systems: Focusing on the Power Plant)

  • 김영철;조일현;이수경
    • 한국화재소방학회논문지
    • /
    • 제29권1호
    • /
    • pp.60-66
    • /
    • 2015
  • 본 연구에서는 가스계 소화설비시스템이 설치된 방호구역에 소화농도유지시간 성능실험인 밀폐도 시험(Enclosure Integrity Test)를 진행하여, 성공에 미치는 사전조치요인에 대하여 실험하였다. 국내외에 발전소 방호구역에 사전 조치를 취한 방호구역과 사전 조치를 취하지 않은 방호구역으로 나누어 Enclosure Integrity Test를 진행하였다. 따라서, 사전조치 여부에 따라 시험의 성공률을 알아보고, 각각의 가스계 소화시스템 및 실의 종류에 따른 Enclosure Integrity Test의 실패 요인, 설계 농도 유지시간 및 체적대비 누설면적의 크기를 확인하였다. 그리고 사전조치를 수행하여 Enclosure Integrity Test의 성공률이 증가되는 것을 알 수 있으며, 실패에 의해 반복되는 실험의 수를 줄임으로 인하여 발생되는 비용을 절약할 수 있었다.