A Study on the Heat Transfer in boiler through the performance test in thermal power plant (화력발전소 보일러내의 열전달에 관한 연구)

  • Kwon, Y.S.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2064-2069
    • /
    • 2004
  • The main reason to analyze heat transfer in boiler inside through the performance test in fossil power plant is to increase plant high efficiency and energy saving movement in the government. Tins study intends to have trend and analyze the boiler heat transfer through the performance test, so it may give us the heat distribution in boiler inside in super-critical and sub-critica1 pressure type power plant

  • PDF

A Study on Indoor Environmental Factors in Elementary School Classroom for Eco-School Planning (에코스쿨 계획을 위한 초등학교 실내 환경계획 요소 조사)

  • Kim, Chang-Sung;Kang, Seung-Ku
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.6
    • /
    • pp.4-11
    • /
    • 2008
  • Global environment is getting deteriorated at an alarming rate. Eco-school could be one of the effective solutions to protect our environment and a good sample of architecture to economize in total energies, resources and greenhouse gases. In case of our country, the study of eco-school planning is not sufficient compared with other countries, so this paper would be a good study on the indoor environment of the classroom by surveying their opinions and ideas from the group of users in elementary school. The result of this study shows that the proper installation of building equipment and nature ventilation system is necessary to provide delightful environment for the students and to save the energy. To ensure that we have adequate saving and protection, it is necessary to change the existing appraisal standard.

A Study on Commercialization of Condensing Fluidized-Bed Heat Exchanger for Paper Mill Hood Exhaust Air (제지설비 후드 배공기의 응축형 유동층열교환기 상용화 연구)

  • Park, Sang-Il
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1101-1106
    • /
    • 2006
  • The water fluidized bed heat exchanger was installed to recover heat from paper mill hood exhaust air containing lot of moisture and also fouling contaminants. The hood exhaust air flow rate was about $110,000m^3/hr$ at $70^{\circ}C$. The commercial scale field test apparatus has been operated for 3 months. As a result of operation, total heat recovered was 2,380,000 kcal/hr and proportion of the latent heat to total heat was 74%. The annual energy saving was estimated as 450 million won.

  • PDF

A Study on Economic Analysis Algorithm for Energy Storage System Considering Peak Reduction and a Special Tariff (피크저감과 특례요금제를 고려한 ESS 경제성 분석 알고리즘에 관한 연구)

  • Son, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1278-1285
    • /
    • 2018
  • For saving electricity bill, energy storage system(ESS) is being installed in factories, public building and commercial building with a Time-of-Use(TOU) tariff which consists of demand charge(KRW/kW) and energy charge(KRW/kWh). However, both of peak reduction and ESS special tariff are not considered in an analysis of initial cost payback period(ICPP) on ESS. Since it is difficult to reflect base rate by an amount of uncertain peak demand reduction during mid-peak and on-peak periods in the future days. Therefore, the ICPP on ESS can be increased. Based on this background, this paper presents the advanced analysis method for the ICPP on ESS. In the proposed algorithm, the representative days of monthly electricity consumption pattern for the amount of peak reduction can be found by the k­means clustering algorithm. Moreover, the total expected energy costs of representative days are minimized by optimal daily ESS operation considering both peak reduction and the special tariff through a mixed-integer linear programming(MILP). And then, the amount of peak reduction becomes a value that the sum of the expected energy costs for 12 months is maximum. The annual benefit cost is decided by the amount of annual peak reduction. Two simulation cases are considered in this study, which one only considers the special tariff and another considers both of the special tariff and amount of peak reduction. The ICPP in the proposed method is shortened by 18 months compared to the conventional method.

Photo-grafting Dyeing of Wool Fabrics with ${\alpha}$-bromoacrylamide reactive dye (반응성 염료를 이용한 양모직물의 광그라프트 염색)

  • Dong, Yuanyuan;Jang, Jin-Ho
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.31-31
    • /
    • 2011
  • Lanasol dyes containing ${\alpha}$-bromoacrylamide or ${\alpha},{\beta}$-dibromopropionylamide group are used for wool dyeing. They are normally applied to wool under pH 4.5 to 6.5 at $100^{\circ}C$. Although wool fabric can be dyed to obtain deep colour, high light and wet fastness, the dyeing processes need long dyeing time at high temperature, with salt addition, which inevitably causes environmental problems. Grafting is a modification method for textile where monomers are covalently bonded onto the polymer chain. It can be initiated by ozone, ${\gamma}$ rays, electron beams, plasma, corona discharge and UV irradiation. Coloration by UV-induced photografting exhibits several advantages such as fast reaction rate, energy saving, simple equipment, easy exploitation and environmentally friendliness. Also it requires much lower energy compared to the conventional dyeing and less damage to the substrate. In this study, a direct sequential UV-induced photografting onto wool fabrics was discussed. To understand the graft polymerization mechanism further, several characterization methods were used. Moreover, the effects of several principal factors on the graft photopolymerization were investigated. Furthermore, the colorfastness results were compared with conventional dyeing methods.

  • PDF

A Holistic Approach to Optimizing the Lifetime of IEEE 802.15.4/ZigBee Networks with a Deterministic Guarantee of Real-Time Flows

  • Kim, Kang-Wook;Park, Myung-Gon;Han, Junghee;Lee, Chang-Gun
    • Journal of Computing Science and Engineering
    • /
    • v.9 no.2
    • /
    • pp.83-97
    • /
    • 2015
  • IEEE 802.15.4 is a global standard designed for emerging applications in low-rate wireless personal area networks (LR-WPANs). The standard provides beneficial features, such as a beacon-enabled mode and guaranteed time slots for realtime data delivery. However, how to optimally operate those features is still an open issue. For the optimal operation of the features, this paper proposes a holistic optimization method that jointly optimizes three cross-related problems: cluster-tree construction, nodes' power configuration, and duty-cycle scheduling. Our holistic optimization method provides a solution for those problems so that all the real-time packets can be delivered within their deadlines in the most energy-efficient way. Our simulation study shows that compared to existing methods, our holistic optimization can guarantee the on-time delivery of all real-time packets while significantly saving energy, consequently, significantly increasing the lifetime of the network. Furthermore, we show that our holistic optimization can be extended to take advantage of the spatial reuse of a radio frequency resource among long distance nodes and, hence, significantly increase the entire network capacity.

The path analysis of carbon emission reduction: A case study of the Silk Road Economic Belt

  • Kong, Yang;He, Weijun
    • Environmental Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.71-79
    • /
    • 2020
  • This paper uses super-efficiency DEA model and Malmquist index to evaluate the carbon emission efficiency (CEE) values of the nine western provinces along the "Silk Road Economic Belt" for the period from 2000 to 2015, and analyses the influencing factors of the CEE. The major findings of this study are the following: (1) the overall CEE of the nine western provinces is not high, and there are significant inter-provincial differences in the CEE. Meanwhile, the provinces with higher levels of economic development generally have higher CEE. (2) The annual total factor productivity (TFP) of the nine western provinces, which is mainly determined by technological change, is greater than 1. Moreover, the total average growth rate of the TFP is 15.5%. (3) The CEE of the nine western provinces is not spatially dependent. In addition, the urbanization, openness, use of energy-saving technologies and research and development (R&D) investment have a significant positive impact on the CEE values, while the industrial structure, foreign direct investment, fixed asset investment, government expenditure levels and energy structure have a significant negative impact on the CEE. Among them, R&D investment is the primary factor in promoting the development of CEE, and the government expenditure has the greatest negative impact on the CEE.

Effects of the Air Volume in the Air Chamber on the Performance of Water Hammer Pump System

  • Saito, Sumio;Takahashi, Masaaki;Nagata, Yoshimi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.2
    • /
    • pp.255-261
    • /
    • 2011
  • Recently, as global-scale problems, such as global warming and energy depletion, have attracted attention, the importance of future environmental preservation has been emphasized worldwide, and various measures have been proposed and implemented. This study focuses on water hammer pumps that can effectively use the water hammer phenomenon and allow fluid transport without drive sources, such as electric motors. An understanding of operating conditions of water hammer pumps and an evaluation of their basic hydrodynamic characteristics are significant for determining whether they can be widely used as an energy-saving device in the future. However, conventional studies have not described the pump performance in terms of pump head and flow rate, common measures indicating the performance of pumps. As a first stage for the understanding of water hammer pump performance in comparison to the characteristics of typical turbo pumps, the previous study focused on understanding the basic hydrodynamic characteristics of water hammer pumps and experimentally examined how the hydrodynamic characteristics were affected by the inner diameters of the drive and lift pipes and the angle of the drive pipe. This paper suggests the effect of the air volume in the air chamber that affects the hydrodynamic characteristics and operating conditions of the water hammer pump.

A study on the selection of optimal marine engine and its techno- economical evaluation method (최적박용기관의 선정 및 그의 경제성 평가방법에 관한 연구)

  • 전효중;조기열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.51-66
    • /
    • 1984
  • The cost percentage of engine part in the total building cost of a ship is about 30-40% and the main engine occupies about 50% of the engine part cost. For certain ships the fuel bill can be as high as about 60-70% of the total operating cost after two oil shocks and its amount for one year is nearly equivalent to her main engine price. This fact has further increased the pressure on the engine builders to develop engines of higher efficiency and better possibilities to burn further deteriorated fuel qualities. But the energy-saving plants are ordinarily more expensive and their available amount of exhaust gas energy is less and therefore, they are not always profitable and optimum systems. This paper is prepared to decide the most economical and efficient engine systems by presenting reasonable selecting and economical evaluation methods of the main engine, which is the largest single unit and the most expensive, and its auxiliaries. In order to demonstrate the application of investigated methods in a practical case, a 46, 000 DWT class bulk carrier is selected as a model ship and her main engine and its auxiliaries are selected and evaluated. The result shows that the optimum determined has one year three months POP, 0.903 IRR at a year, 4, 116, 000 dollars PW in 15 years (for 5% escalation rate of fuel cost) and 9.522 BCR for same condition, when the engine plant of a same existing ship is taken as the basis.

  • PDF

A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.