• Title/Summary/Keyword: Saturation Phenomenon

Search Result 112, Processing Time 0.018 seconds

Blood Pressure Reactivity during Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)이 혈력학적(血力學的) 변화(變化)에 끼치는 영향(影響))

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.

  • PDF

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.