• 제목/요약/키워드: Saturated temperature

검색결과 613건 처리시간 0.02초

Mechanical and acoustic behaviors of brine-saturated sandstone at elevated temperature

  • Huang, Yan-Hua;Yang, Sheng-Qi
    • Geomechanics and Engineering
    • /
    • 제17권2호
    • /
    • pp.215-225
    • /
    • 2019
  • The mechanical behavior of rock is essential to estimate the capacity and long-term stability of $CO_2$ storage in deep saline aquifers. As the depth of reservoir increases, the pressure and temperature that applied on the rock increase. To answer the question of how the confining pressure and temperature influence the mechanical behavior of reservoir rock, triaxial compression experiments were carried out on brine-saturated sandstone at elevated temperature. The triaxial compressive strength of brine-saturated sandstone was observed to decrease with increasing testing temperature, and the temperature weakening effect in strength enhanced with the increase of confining pressure. Sandstone specimens showed single fracture failures under triaxial compression. Three typical regions around the main fracture were identified: fracture band, damaged zone and undamaged zone. A function was proposed to describe the evolution of acoustic emission count under loading. Finally, the mechanism of elevated temperature causing the reduction of strength of brine-saturated sandstone was discussed.

액체유도체의 절연특성에 미치는 초음파의 영향 (Ultransonic Effect on the Break-Down Characteristics of Liquid Dielectrics)

  • 전춘생;김홍근;홍봉식
    • 전기의세계
    • /
    • 제26권4호
    • /
    • pp.61-67
    • /
    • 1977
  • This paper treats the Ultrasonic effects on the break down characteristics of Liquid Dielectric Material 1) Relative Dielectric constant, Es of Liquid Dielectric Material at a constant temperature decreases in proportion to the irradiated time of Ultrasonic radiation and its intensity, and reaches to a certain saturated value. The saturated value varies with the intensity of Ultrasonic radiation. 2) Power factor of Liquid Dielectric Material at a constant temperature increases in proportion tothe irradiated time of Ultrasonic radiation and its intensity, and reaches to a certain saturated value. The saturated value varies with the intensity of Ultrasonic radiation. 3) Relative resistance of Liquid Dielectric Material at a constant temperature decrease with the irradiated time of Ultrasonic radiation, but the effect of its intensity is very irregular. 4) Break-down strength of Liquid Dielectric Material, at a constant temperature decreases with the irradiated time of Ultrasonic radiation and its intensity, and then reaches to a saturated value.

  • PDF

Delineation of Groundwater and Estimation of Seepage Velocity Using High-Resolution Distributed Fiber-Optic Sensor

  • Chang, Ki-Tae;Pham, Quy-Ngoc
    • 한국지반환경공학회 논문집
    • /
    • 제16권6호
    • /
    • pp.39-43
    • /
    • 2015
  • This study extends the Distributed Temperature Sensing (DTS) application to delineate the saturated zones in shallow sediment and evaluate the groundwater flow in both downward and upward directions. Dry, partially and fully saturated zones and water level in the subsurface can be recognized from this study. High resolution seepage velocity in vertical direction was estimated from the temperature data in the fully saturated zone. By a single profile, water level can be detected and seepage velocity in saturated zone can be estimated. Furthermore, thermal gradient analysis serves as a new technique to verify unsaturated and saturated zones in the subsurface. The vertical seepage velocity distribution in the recognized saturated zone is then analyzed with improvement of Bredehoeft and Papaopulos' model. This new approach provides promising potential in real-time monitoring of groundwater movement.

함수다공질층의 진공건조에 관한 실험적 연구 (Ⅰ) (An Experimental Study on Vacuum Drying of Water-Saturated Porous Media)

  • 박형진;김경근;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권5호
    • /
    • pp.68-75
    • /
    • 1996
  • The vacuum drying characteristics of water-saturated porous media were studied experimentally. The water-saturated porous media, water-saturated sand layer, was heated by the isothermal bottom wall of the rectangular vessel. The vacuum drying rate and temperature distribution of the sand layer were measured and calculated under a variety of conditions of heated wall temperature, vacuum rate, and thickness of the test material. It was found that the drying rate due to the heat and mass teansfer is greatly influenced by the heated wall temperature, vacuum rate, and thickness of the test material.

  • PDF

수포화 암석코어의 상온 전기비저항 모니터링 (Resistivity Monitoring of Saturated Rock Cores at Room Temperature)

  • 이상규;이태종;이명종
    • 지구물리와물리탐사
    • /
    • 제18권3호
    • /
    • pp.105-114
    • /
    • 2015
  • 상온 상습 환경에서 수포화 암석코어의 전기비저항을 장시간 모니터링 할 수 있는 장치를 구현하였다. 양쪽 금속망 전극에 덧댄 종이필터와 암석코어를 감싼 열수축튜브의 상부 중앙 외피면에 3-채널 펌프로 물을 충분히 공급하면서 전기저항을 측정하면 암석코어의 수포화 상태를 유지하면서 일주일 이상 전기비저항을 모니터링 할 수 있다. 이 장치를 이용하여 흑운모 편마암, 안산암질 응회암, 셰일의 3종류 암석코어의 수포화 전기저항을 9일간 모니터링 한 결과 다음과 같은 2가지 가설을 제시할 수 있었다. 즉, 전기비저항 온도계수의 수렴 속도는 열물성과 관련이 있을 것이라는 것과 건조 저항을 수포화 때의 평균 저항으로 나눈 건조/수포화 저항비는 유효공극률과 상관될 것이라는 것이다. 실제로, 3가지 암석의 건조/수포화 저항비는 각각 48, 705, 2로 나타났고 이때 각각의 유효공극률은 3.7%, 3.3%, 13.0%이었다.

The Characteristics of a Pump at Nearly Saturated State

  • Kim, S. N.;Kim, J. C.
    • Nuclear Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.40-46
    • /
    • 1998
  • A set of experiments using a 1/10 scale model pump which was manufactured to simulate performance of reactor coolant pump(RCP) of Y.G.N # 3 and 4, was executed in single phase(at atmospheric pressure and room temperature) and near-saturation(300 ~ 600kPa). The pump characteristics in single phase flow was similar to the characteristics of the RCP. The pump characteristic curves at nearly saturated state were correlated in terms of flow coefficient and head coefficient for subcooled temperature using the cavitation number defined as (equation omitted), which can be predicted the cavitation possibility. The pump behavior around the saturated temperature almost consists with single phase behavior until the cavitation occurs(When cavitation occurs. When the flow coefficient is about 0.12), the pump head rapidly degrades. In this situation, subcooled temperature is about 1.8~8$^{\circ}C$ and cavitation number of model pump is 1.0 ~ 1.7.

  • PDF

Vegetation Canopy의 접지층 환경에 대한 열적 영향 제1부 : 수치실험 (On the Thermal Effect of Vegetation Canopy to the Surface Sublayer Environment Part 1 : Numerical Experiment)

  • 진병화;황수진
    • 한국환경과학회지
    • /
    • 제8권2호
    • /
    • pp.145-150
    • /
    • 1999
  • To estimate the thermal effect of the vegetation canopy on the surface sublayer environment numerically, we used the combined model of Pielke's1) single layer model for vegetation and Deardorff's2) Force restore method(FRM) for soil layer. Application of present combined model to three surface conditions, ie., unsaturated bare soil, saturated bare soil and saturated vegetation canopy, showed followings; The diurnal temperature range of saturated vegetation canopy is only 20K, while saturated bare soil and unsaturated bare soil surface are 30K, 35K, respectively. The maximum temperature of vegetation canopy occurs at noon, about 2 hours earlier than that of the non-vegetation cases. The peak latent heat fluxes of vegetation canopy is simulated as a 600Wm-2 at 1300 LST. They have higher values during afternoon than beforenoon. Furthermore, the energy redistribution ratios to latent heat fluxes also increased in the late afternoon. Therefore, oasis effect driving from the vegetation canopy is reinforced during late afternoon compared with the non-vegetated conditions.

  • PDF

Free vibration of Cooper-Naghdi micro saturated porous sandwich cylindrical shells with reinforced CNT face sheets under magneto-hydro-thermo-mechanical loadings

  • Yazdani, Raziye;Mohammadimehr, Mehdi;Navi, Borhan Rousta
    • Structural Engineering and Mechanics
    • /
    • 제70권3호
    • /
    • pp.351-365
    • /
    • 2019
  • In this paper, free vibration of Cooper-Naghdi micro sandwich cylindrical shell with saturated porous core and reinforced carbon nanotube (CNT) piezoelectric composite face sheets is investigated by using first order shear deformation theory (FSDT) and modified couple stress theory (MCST). The sandwich shell is subjected to magneto-thermo-mechanical loadings with temperature dependent material properties. Energy method and Hamilton's principle are used for deriving of the motion equations. The equations are solved by Navier's method. The results are compared with the obtained results by the other literatures. The effects of various parameters such as saturated porous distribution, geometry parameters, volume fraction and temperature change on the natural frequency of the micro-sandwich cylindrical shell are addressed. The obtained results reveal that the natural frequency of the micro sandwich cylindrical shell increases with increasing of the radius to thickness ratio, Skempton coefficient, the porosity of the core, and decreasing of the length to radius ratio and temperature change.

고온 공기분사공정에 의한 유류오염대수층의 TPH 제거 (TPH Removal of Oil-Contaminated Soil by Hot Air Sparging Process)

  • 이준호;박갑성
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.665-675
    • /
    • 2007
  • In-situ Air Sparging (IAS, AS) is a remediation technique in which organic contaminants are volatilized from saturated zone to unsaturated layer. This study focuses on the removal and interaction of Volatile Organic Compounds (VOCs) and $CO_2$, and Total Petroleum Hydrocarbon (TPH) in saturated and unsaturated, and air space zone on the unsaturated soil surface. Soil sparging temperature of hot air has risen to $34.9{\pm}2.7^{\circ}C$ from $23.0{\pm}1.9^{\circ}C$ for 36 days. At the diffusing point, fluid TPH concentrations were reduced to 78.7% of the initial concentration in saturated zone when hot air was sparged. The TPH concentrations were decreased to 66.1% for room temperature air sparging. The amount of VOCs for hot air sparging system, in air space, was approximately 26% larger than constant air sparging system. The amount of $CO_2$ was 4,555 mg (in unsaturated zone) and 4,419 mg (in air space) when hot air was sparged was 3,015 mg (in unsaturated zone) and 3,634 mg (in air space) for room air temperature in the $CO_2$ amount. The removals of VOCs and biodegradable $CO_2$ through the hot air sparging system (modified SVE) were more effective than the room temperature air sparging. The regression equation were $Y=976.4e^{-0.015{\cdot}X}$, $R^2=0.98$ (hot air sparging) and $Y=1055e^{-0.028{\cdot}X}$, $R^2=0.90$ (room temperaure air sparging). Estimated remediation time was approximately 500 days, if final saturated soil TPH concentration was set to 1.2 mg/L application of tail effect.

푸울 沸騰時 過渡的 流體溫度 變動 (Transient fluid temperature fluctuation in boiling)

  • 김종일;정충식
    • 대한기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.44-47
    • /
    • 1988
  • 본 실험에서는 온도측정용 써미스터인 고감도의 비드형 써미니스터를 이용하여 물의 감압증발에 의한 불등식 푸울내의 깊이 방향과 반경방향의 온도변화를 연속적으로 측정하여 연구한 결과를 보고한다.