• 제목/요약/키워드: Sand filtration

검색결과 174건 처리시간 0.025초

맥동식 침전지에서 맛·냄새 유발물질 제거 특성 (Removal Property of Taste and Odor Causing Material in Pulsator Clarifier)

  • 정일용;차민환
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.104-109
    • /
    • 2011
  • The removal efficiencies of 2-methylisoborneol (MIB) and geosmin were investigated to reveal removal characteristics of typical organic compounds causing disagreeable taste and odor at the conventional water treatment plant installed with pulsator clarifier patented by the French company $Degr{\acute{e}}mont$. The injection rate of Powdered Activated Carbon (PAC) into water was changed step wisely as we conducted jar tests in the laboratory and water treatment in the actual plant. 2-MIB concentration decreased linearly while geosmin did exponentially along with the injection rate of PAC at our jar tests. The removal efficiency of geosmin by PAC injection was considerably higher than that of 2-MIB. In the real pulsator clarifier, 2-MIB concentration started decreasing as the injection rate reached up to 10 mg/L of PAC. On the other hand, the concentration of geosmin in water decreased proportional to the injection rate of PAC. In the sand filtration, removal efficiencies of 2-MIB and geosmin on July were much higher than those on March. It was carefully suggested beforehand and found afterwards that general microorganisms notably existed in the sand filter with no chlorine in filter influent and backwash water and the sand filter biologically activated removed much more odor compounds. It was considered as the reason why the removal efficiency of 2-MIB and geosmin was increased. The microbial activity maybe increased in summer with water temperature rising and low filtration rate possibly increased contact time between odor compounds and general microorganisms.

다목적 여과저류지에서 여과수의 산출율과 수질개선도에 관한 실험연구 (An Experimental Study on the Production Rate and Contaminant Removal of Filtrate in Multi-purpose Filtration Pond)

  • 정재민;최홍규;정관수;김승현
    • 대한환경공학회지
    • /
    • 제35권7호
    • /
    • pp.518-524
    • /
    • 2013
  • 다목적 여과저류지에서 모래여재의 여과수 여과능, 적정한 표층폐색 제거주기 그리고 오염제거효율 등 설계와 운영요소를 파악하기 위하여 서로 다른 3가지 입경의 낙동강 준설토를 채운 파일럿 규모의 테스트베드를 운영하였으며, 여과저류지에서의 다양한 인공하천의 유속을 모사하기 위하여 표류수 유속을 0~40 cm/sec로 단계적으로 변화시켰다. 운영결과 여재표층의 슬러지를 7~13일의 주기로 제거함으로써 여과수량을 5~3 $m^3/m^2-day$로 유지할 수 있었고, 여과수량과 여재입경 그리고 표류수 유속 등의 차이에 의한 여과수의 수질차이가 없음을 알 수 있었다. 대부분의 오염제거는 표층 50 cm 부근에서 발생함을 알 수 있었고, 여과거리 2.4 m에서의 오염제거율은 탁도 80~95%, COD 20~30%, BOD 75~90%, T-N 5~20% 그리고 T-P 20~60%로, 주로 입자성 오염물의 제거율이 높은 것으로 나타났다.

광산배수 부유물질 저감을 위한 다양한 여과 매질의 특성 및 적용성 평가 - H 석탄광산 배수 (Feasibility Tests for Treating Fine Suspended Solids from Mining Drainage, using Various Media by Column Methods - A Case from H Coal Mine)

  • 이상훈;권혁현;오민아;이재영;김덕민
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권6호
    • /
    • pp.112-118
    • /
    • 2012
  • Fine suspended solids from mine drainage draw attentions due to their potential adverse influences on the water quality, such as increasing turbidity and degrading aesthetic landscape. Currently, sand filter beds are adapted in some mine drainage treating systems. However, more efficient system is in demand, as the existing sand beds reveal some problems, such as frequent maintenance intervals. Various filtering mediums including fly ash, mine tailing aggregates and the sand were tested for improving the current system, using column experimental set-up. Mine drainage samples were collected from the current treating systems in the abandoned H coal mine. The experiment was run for 7 days. Suspended solids recorded as 100.9 mg/L and the value exceeds the current standard, 30 mg/L. Sand was proved to still be the optimum medium for the fine suspended solids, compared to fly ash and fly ash + sand. Mine tailing aggregates were placed at the exit of the columns, substituting gravels. The tailing aggregates is made by mine tailings and clay. Sand bed filters can also be improved by mixing granular activated carbon, which was found to be economical and efficient in the batch experiment, conducted at the same time.

모듈형 이동식 물생산 시스템 운전 성능 및 자연 유기물 제거 거동 평가 (Evaluation of the performance and the removal characteristics of natural organic matter in a modular mobile water production system)

  • 황유훈;양필제;송지민;홍민지;최창형;고석오;김도군
    • 상하수도학회지
    • /
    • 제32권1호
    • /
    • pp.55-65
    • /
    • 2018
  • It is necessary to develop a mobile water production system in order to provide stable water supply in case of disasters such as floods or earthquakes. In this study, we developed a modular mobile water production system capable of producing water for various uses such as domestic water and drinking water while improving applicability in various raw water sources. The water production system consists of three stages of filtration (sand filtration - activated carbon filtration - pressure filtration) to produce domestic water and an additional reverse osmosis process to produce drinking water. In laboratory and field experiments, the domestic water production system showed excellent treatment efficiency for particulate matter, but showed limitations in the treatment of dissolved substances such as dissolved organic matter. In addition, ultraviolet irradiation was considered as additional disinfection step, because it does not form precipitates of manganese oxides after disinfection. Reverse osmosis process was added to increase the removal efficiency of dissolved substances and the treated water satisfied drinking water quality standards. Fluorescence analysis of dissolved organic matter showed that the fulvic acid-like substances in raw water was successfully removed in the reverse osmosis process. The mobile water production system developed in this study is expected to be used not only in water supply in case of disaster, but also widely used in islands and rural area.

정수처리에서 생물학적 망간처리 (Biological Manganese Removal in Water Treatment)

  • 김범수;윤재경;안효원;김충환
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.44-52
    • /
    • 2006
  • Bio-filtration processes using honeycomb tubes (process 1) and aeration and manganese-sand filtration (process 2) were evaluated for the biological manganese removal efficiency. The concentration of manganese at effluent was stabilized after 20days operation in process 1. It was estimated the required time for attaching and growing microorganisms to honeycomb tubes. In long term of operation periods, manganese removal efficiency was dropped for the excessively attached biofilm and manganese dioxide to honeycomb tubes. It took several days for normal operation in process 2, after that manganese removal efficiency was increased to 98% and stabilized for 1.5 years. Microorganisms in process 1 and 2 were isolated and cultured to characterize manganese-oxidizing bacteria. Among the four types of colony, light brown colony was turned blue color by leuco crystal violet spot test. Stenotropomonas genus, known as manganese-oxidizing bacteria, was identified by 16S rDNA partial sequencing analysis which was isolated in process 1 and 2. For the biological treatment to remove manganese, these two considerations are important. One is to choose the proper media attaching manganese oxidant, another one is to define the cultural condition of isolated manganese-oxidizing bacteria.

낙동강 하류원수에 적합한 여과지의 여재구성 (The adaptive filter configuration for down stream of Naktong river)

  • 김상구;류동춘;이영식;손진언
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.95-95
    • /
    • 1995
  • This study was carried out to evaluate the variations of headloss rate and of specific deposit to depths with effective size of media and configuration of filter layer during algae blooming period. 0.51mm size media was disqualified because most of headloss occurred rapidly below 5cm from surface layer however 0.91mm size media acted deep filtration more than 20cm from top, as result 0.91mm sixte media filter had 2∼3 times longer filtration time than 0.51mm sixte media filter, but 0.91mm size media have break-through potentiality. multi-layer filter with 1.02mm anthracite and 0.51mm sand had large deposit volume in upper layer that could longer filtration time, moreover smaller media in lower layer that could protect break-through.

도로노면 유출수 처리를 위한 여과에서의 여재별 손실수두 특성 (A study on the headloss of filter media for treatment of Road Runoff)

  • 최원석;송창수;김석구
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.697-704
    • /
    • 2008
  • Stormwater runoff from urban road area as non-point source has a tendency of including lots of pollutants at initial rain period. Recently, there are several cases of having installed treatment facilities for reducing pollution discharge from the impervious cover in urban area to prevent watershed environment from getting worse. The filtration type among non-point source treatment systems has been known as one of the most efficient system for treatment of non-point source pollutants. Therefore, various kinds of filter media such as expanded polypropylene(EPP), granular activated carbon, zeolite, perlite, illite, sand, gravel has been developed. This study was conducted to verify performance and hydraulic characteristics of filter media as measures for non-point source. The experiment was carried out to evaluate applicability and variation of 4 kind of most popular filter media(EPP, GAC, Zeolite, Perlite) in headloss with elapsed time and influent flow rate and to obtain data base that could be used to establish management plan for road runoff treatment. In experiment by tap water, it showed that EPP and perlite those are floatable materials showed stable operating performance and lower headloss than the others.

정수처리공정에서 bisphenol-A의 제거에 관한 연구 (Bisphenol-A Removal in Conventional Water Treatment Systems)

  • 김혜리;이윤진;박선구;남상호
    • 한국환경보건학회지
    • /
    • 제30권1호
    • /
    • pp.59-64
    • /
    • 2004
  • This study was carried out to investigate influencing factors of bisphenol A(BPA) removal characteristic in conventional water treatment systems to be connected with coagulation, sedimentation, filtration and disinfection. The result are summarized as follows; In BPA removal, optimal doses of PAC, alum, ferric chloride were 7.5 mg Al/L, 10.0 mg AI/L, 15.0 mg Fek. PAC was most effective coagulant to remove BPA. In coagulation process, BPA removal efficiency were increased about 2% by adjusting pH of raw water as 6. At temperature rise 1$0^{\circ}C$, BPA removal efficiency were increased 0.94%. but BPA removal efficiency in sand filtration process were under 1 %ie, so that BPA was almost not removed. At free chlorine dose 1, 2 mg/L, the reaction rate constant k in the BPA removal have been calculated to be 0.397, 0.953 min$^{-1}$ . At free chlorine dose 1, 2 mg/1-, degradation reaction of BPA was completed during 10 min and BFA removal efficiencies were 97.66, 99.99% at this time.

농어촌의 수질오염과 수질특성에 적합한 정수 처리시스템의 개발에 관한 연구(1) (A Survey of water pollution and the development of water treatment system on agricultural Area)

  • 정문호;김영규;조태석;배현주;신명옥;김수연;김민지;김민영;김수복
    • 환경위생공학
    • /
    • 제12권2호
    • /
    • pp.65-74
    • /
    • 1997
  • The purpose of this study was to investigate the removal effect and variation of contaminated water by various water treatment processes using sediment filter, activated carbon, photocatalysis, reverse osmosis, ultra violet sterilizer and ultra filtration. The removal effect of chloride and trace metal was low by activated carbon and ultra filter but high in reverse osmosis. The removal effect of bacteria and E. coli was low by activated carbon and membrane filter system using activated carbon but high in impregnated activated carbon. The removal effect of TCE was low in sand and ultra filter system as compared with activated carbon. Ultra filtration process was effective for purify agricultural water without E.coli. Reverse osmosis was effective to remove heavy metal and activated carbon was effective to remove halogenated organic chemical compound. The flux and the removal effect of COD in spiral wound ultrafilter were higher than the hollow fiber ultrafilter.

  • PDF

정수처리과정(淨水處理過程)에서의 잔류불소(殘留弗素)이온 거동(擧動)에 관한 연구(硏究) (A Study on the Behavior of Residual Fluoride in Water Treatment Process)

  • 이택순;문병현;서규태;진홍식
    • 상하수도학회지
    • /
    • 제14권2호
    • /
    • pp.164-173
    • /
    • 2000
  • Fluoridation of drinking water to a level of about 0.8mg/l (below 1.5mg/l) for reducing the incidence of tooth decay is recommended. However, concerns about potential problems of unknown effects and overdosing hinders the fluoridation. This study describes the work performed to obtain information on the behavior of fluoride under various conditions in the process of water fluoridation. Effects of water treatment chemicals, water treatment unit, and water distribution on water fluoridation were investigated at both lab and an actual water treatment plant. Residual fluoride concentration was not affected by lime and chlorine dosage up to 20mg/l. Flocculation with PAC slightly decreased the residual fluoride concentration as PAC dosage increased. Average fluoride concentration of 0.87mg/l at an intake basin was decreased to 0.83mg/l by sedimentation, 0.81mg/l by dual media(sand+anthracite) filtration, and 0.79mg/l by granular activated carbon filtration in the water treatment plant.

  • PDF