• 제목/요약/키워드: Sampling volume

검색결과 342건 처리시간 0.026초

공기중 염화비닐단량체의 포집시 공기 포집량이 파과에 미치는 영향 (Effect of sampling volume on the breakthrough of charcoal tube during vinyl chloride monomer sampling)

  • 윤존중;임남구;김치년;노재훈
    • 한국산업보건학회지
    • /
    • 제11권3호
    • /
    • pp.241-248
    • /
    • 2001
  • The main factors of breakthrough are known to sampling time, flow rate, concentration of the sample, temperature, humidity, and the physical characteristics of the solid sorbent tube. However, no study has been reported the effect of temperature and sampling volume on the breakthrough of acharcoal tube during vinyl chloride monomer (VCM) sampling. The objective of this study is to suggest the optimal sampling condition during VCM sampling based on National Institute for Occupational Safety and Health (NIOSH) method. To evaluate adequate sampling volume for VCM without breakthrough, volume of 1, 2, 3, 4, and 5 L each from VCM of 1, 5, 10, 15, and 20ppm at flow rate of 0.05 L/min were sampled in $22^{\circ}C$ and $40^{\circ}C$. At $22^{\circ}C$, in the case of 1, 5, 10, and 15ppm, VCM was adsorbed completely in first section of charcoal tube regardless of sampling volume. But in 20ppm, detection rates are 99.56% in first section and 0.44% in second section. At $40^{\circ}C$ of 1ppm, VCM was adsorbed completely in first section. In 10, 15, and 20ppm, detection rates of second, third, and forth sections were decreased significantly by reduction of sampling volume. In determination of breakthrough based on NIOSH method, no breakthrough was occurred in 20ppm at $22^{\circ}C$. At $40^{\circ}C$, breakthrough was occurred in 10, 15, and 20ppm when sampling volume was 5L. Although no breakthrough was occurred when sampling volume was 3L. Finally, in environment of temperature around $22^{\circ}C$, breakthrough may not occurred up to 20ppm during sampling for VCM. During sampling for VCM in environment of temperature around $40^{\circ}C$, no breakthrough occurred in 1-5ppm and 10-20ppm when sampling volume is 5L and 3L respectively. This result suggests that the sampling volume should be considered when VCM sampling under hot conditions (> $22^{\circ}C$) by the NIOSH method No. 1007.

  • PDF

대기 중 다환방향족 탄화수소의 측정을 위한 시료포집방법의 비교평가 (Evaluation of Sampling Methodology for the Measurement of Polycyclic Aromatic Hydrocarbons in the Atmosphere)

  • 백성옥;최진수
    • 한국대기환경학회지
    • /
    • 제14권1호
    • /
    • pp.43-62
    • /
    • 1998
  • This study was carried out to investigate the influence of different sampling methods on the measured concentrations of polycyclic aromatic hydrocarbons (PAH) both in the vapor and particulate phases, and to evaluate the effects of ambient temperature and sampling duration on the losses of PAH associated with particle samples due to volatilization. The experimental protocol of this study is consisted of two parts. The first part is related to the comparison of PAH concentrations measured by 4 different sampling systems, each of which involves different sampling principles for comparison purposes, including a medium-volume sampler with XAD-2 adsorbent, a high-volume sampler with polyurethane foam (PUF), two identical low-volume samplers: one with XAD-2 and the other with PUF, respectively. The second part of this study is to quantitatively estimate the losses of particulate PAH samples by volatilization during sampling, using two identical low-volume samplers: one was used for changing the filters every 3 hrs, 6 hrs, 12 hrs, and 24 hrs sampling, while the other was maintained for continuous 48 hours sampling without changing the filter. The concentrations of volatile PAH including 2-3 rings appeared to be significantly affected by the type of adsorbent. Measured levels of these lower-molecular weight PAH by XAD-2 adsorbent were much higher than those by PUF for both high-volume and low-volume sampling. PUF was found to give rise to unknown components that interfered with the PAH analysis, even after extensive clean-up. In addition, the retention efficiency of PUF for lower molecular weight PAH was subject to a large variation, being significantly influenced by sampling conditions such as ambient temperature. However, the effect of sampling methods with different adsorbents on the measured levels of semi-volatile compounds including 4 rings PAH such as fluoranthene, pyrene, BaA and chrysene, was not so much significant as more volatile PAH compounds. It was also clear from this study that volatilization losses of the semi-volatile PAH collected on the filters were inevitably occurred during prolonged sampling, and hence the results obtained from conventional sampling methods may not be expected to yield an accurate distribution of PAH between the vapor and particulate phases.

  • PDF

임분재적(林分材積) 추정(推定)에 관(關)한 연구(硏究) (Study on the Estimate of Stand Volume in the Pitch Pine Forest)

  • 이여하
    • 한국산림과학회지
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 1973
  • 본시험(本試驗)은 리기다소나무 인공단순림(인공단순림)에 있어서 임분재적추정(林分材積推定)을 단급법(單級法) 단순임의추출법(單純任意抽出法) 복합비추정법(複合比推定法) 분리비추정법(分離比推定法) 표준목비추정법(標準木比推定法)등의 방법(方法)으로 조사비교(調査比較)한 것이다. 비추정(比推定)에 의하여 얻은 결과(結果)는 표(表) 8과 같아 실제임분재적(實際林分材積)이 추정임분재적내(推定林分材積內)에 포함(包含)되어 있는 것은 단순임의추출법(單純任意抽出法)과 복합비추정법(複合比推定法)뿐이다. 단순임의추출법(單純任意抽出法)이 좋은 결과(結果)를 갖어온 것은 임분(林分)의 구성상태(構成狀態)가 단순동령림(單純同齡林)이기 때문이라 추측(推測)된다. 추정시(推定時) 측정(測定)이나 계산(計算)이 간편한것은 (1) 단급법(單級法) (2) 단순임의추출법(單純任意抽出法) (3) 표준목비추정법(標準木比推定法) (4) 분리비추정법(分離比推定法) (5) 복합비추정법(複合比推定法)의 순(順)으로 되어 정도면(精度面)이나 실제임분(實際林分) 재적(材積) 측정시(測定時) 시간경비(時間經費) 노력(勞力)을 비교적(比較的) 적게 들이고 측정(測定)할수 있는 방법(方法)은 적어도 인공일제림(人工一齊林)에서는 단순임의추출법(單純任意抽出法)이 가장 좋은 결과(結果)를 가져왔다고 본다.

  • PDF

빈공간 교란과 샘플링 위치 정렬을 이용한 고화질 볼륨 가시화 (High Quality Volume Rendering Using the Empty Space Jittering and the Sampling Alignment Method)

  • 계희원
    • 한국멀티미디어학회논문지
    • /
    • 제16권7호
    • /
    • pp.852-861
    • /
    • 2013
  • 의료영상을 이용한 볼륨가시화를 수행할 때, 사용자가 관심있는 영역을 확대 관찰하는 일은 빈번하게 발생한다. 확대 영상에서 나뭇결 결함으로 불리는 문제가 발생하기 때문에, 기존 연구는 교란 샘플링을 이용하여 문제를 해결하였다. 그러나 교란 샘플링 방법은 관찰 영역 경계에서 잡음이 발생하는 문제가 있다. 본 연구는 교란 샘플링 시 경계에서 발생하는 잡음의 원인을 설명하고 그 해결 방법을 제시한다. 잡음 없이 나뭇결 결함을 제거하기 위해, 본 연구는 빈공간교란 기법과 샘플링 위치 정렬 기법을 제안한다. 제안 방법을 통해, 추가 시간 없이 고화질 볼륨가시화 영상을 생성할 수 있다.

A Comparative Study Between Light Extinction and Direct Sampling Methods for Measuring Volume Fractions of Twin-Hole Sprays Using Tomographic Reconstruction

  • Lee, Choong-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.1986-1993
    • /
    • 2003
  • The spatially resolved spray volume fractions from both line-of-sight data of direct measuring cells and a laser diffraction particle analyzer (LDPA) are tomographically reconstructed by the Convolution Fourier transformation, respectively. Asymmetric sprays generated from a twin-hole injector are tested with 12 equiangular projections of measurements. For each projection angle, a line-of-sight integrated injection rate was measured using a direct sampling method and also a liquid volume fraction from a set of line-of-sight Fraunhofer diffraction measurements was measured using a light extinction method. Interpolated data between the projection angles effectively increase the number of projections, significantly enhancing the signal-to-noise level in the reconstructed data. The reconstructed volume fractions from the direct sampling cells were used as reference data for evaluating the accuracy of the volume fractions from the LDPA.

Volume Rendering를 위한 향상된 Sampling 방법 (Improved Sampling Method For Volume Rendering)

  • 박재영;이병일;최흥국
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2000년도 하계종합학술대회논문집
    • /
    • pp.213-216
    • /
    • 2000
  • 본 논문에서는 volume rendering 기법을 이용하여 2차원 MRI 영상들을 합성하여 3차원 영상 만들 때 보다 해상도를 높이기 위한 개선된 sampling방법을 소개한다 2차원 슬라이스 영상들이 3차원으로 재구성할 때 voxel 기반으로 렌더링을 하기 때문에 오브젝트의 내부 영역까지도 볼 수 있는 것이 volume rendering의 가장 큰 장점이다. 따라서 영상을 재구성하는 과정에서 보다 향상된 interpolation을 적용시켜서 공간 해상도를 향상시키면 보다 명확하게 오브젝트 내부 정보를 살펴 볼 수 있다. 본 논문에서는 nearest neighbor 이나 linear 같은 interpolation으로 sampling한 방법보다 cubic interpolation을 3차원 공간에서 적용 시켜서 보다 resampling이 잘 되도록 하여 해상도를 향상시켜 보았다. 이렇게 향상된 Interpolation 적용시켜서 렌더링할 때 얼마나 오브젝트 내부 영역이 잘 가시화가 되었는지 transfer function을 적용시켜서 오브젝트 내부 정보를 렌더링 해보았고, 임의의 축으로 오브젝트을 잘라서 2D 단면 영상으로 출력해 보았다. 보다 향상된 interpolation을 적용시켜서 resampling을 하면 영상 해상도가 개선되었음을 볼 수 있었다.

  • PDF

The Volume Measurement of Air Flowing through a Cross-section with PLC Using Trapezoidal Rule Method

  • Calik, Huseyin
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.872-878
    • /
    • 2013
  • In industrial control systems, flow measurement is a very important issue. It is frequently needed to calculate how much total fluid or gas flows through a cross-section. Flow volume measurement tools use simple sampling or rectangle methods. Actually, flow volume measurement process is an integration process. For this reason, measurement systems using instantaneous sampling technique cause considerably high errors. In order to make more accurate flow measurement, numerical integration methods should be used. Literally, for numerical integration method, Rectangular, Trapezoidal, Simpson, Romberg and Gaussian Quadrature methods are suggested. Among these methods, trapezoidal rule method is quite easy to calculate and is notably more accurate and contains no restrictive conditions. Therefore, it is especially convenient for the portable flow volume measurement systems. In this study, the volume measurement of air which is flowing through a cross-section is achieved by using PLC ladder diagram. The measurements are done using two different approaches. Trapezoidal rule method is proposed to measure the flow sensor signal to minimize measurement errors due to the classical sampling method as a different approach. It is concluded that the trapezoidal rule method is more effective than the classical sampling.

임목재적(林木材積) 산정(算定)을 위(爲)한 Simple Random Sampling과 Two-stage P.P.S. Sampling 방법(方法)의 비교(比較) (Comparison of Simple Random Sampling and Two-stage P.P.S. Sampling Methods for Timber Volume Estimation)

  • 김재수
    • 한국산림과학회지
    • /
    • 제65권1호
    • /
    • pp.68-73
    • /
    • 1984
  • Simple random sampling과 P.P.S. sampling의 효율을 비교하기 위하여 오스트리아 Salzburg 부근의 침엽수 장령림 임분에서 임목조사를 실시하였다. 축적 1:10,000의 흑백 적외선 사진을 판독하여, 조사 임지를 제지, 유령림, 너도 밤나무 장령림, 침엽수 장령림으로 구분하고, 침엽수 장령림 내에서 random sampling에 의한 99개의 표본점과 P.P.S. sampling에 의한 75개의 표본점을 흉고 단면적 제수 4인 Relascope에 의하여 야외 조사한 자료를 비교한 결과는 다음과 같다. 1) random sampling에 의한 임분 재적의 추정치는 $422.0m^3/ha$이었고, P.P.S. sampling에 의해서는 $433.5m^3/ha$이었으나 이들간의 통계적 유의성은 없었다. 2) 5 %의 허용 오차내에서는 P.P.S. sampling에 의하여는 170점, random sampling에 의하여는 237점이 필요하였다. 3) P.P.S. sampling은 random sampling에 비하여 야외 조사 시간을 17% 감소시킬 수 있었다.

  • PDF

A Simple Proposition for Improving Industrial Hygiene Air Sampling Methods

  • Paik, Samuel Y.;Zalk, David M.
    • Safety and Health at Work
    • /
    • 제10권3호
    • /
    • pp.389-392
    • /
    • 2019
  • When conducting an exposure assessment, the primary goal of the industrial hygienist is to fully characterize the worker's exposure during a work shift to compare it with an occupational exposure limit. This applies regardless of the duration of the work activity as an activity that is relatively short in duration can still present exposure in excess of the occupational exposure limit even when normalized over an 8-hr shift. This goal, however, is often impeded by the specification of a minimum sample volume in the published sampling method, which may prevent the sample from being collected or submitted for analysis. Removing the specification of minimum sample volume (or adjusting it from a requirement to a recommendation), in contrast, allows for a broader assessment of jobs that consist of short-duration and high-exposure activities and also eliminates the unnecessary practice of running sampling pumps in clean air to collect a specified, minimum volume.

Fast Volume Visualization Techniques for Ultrasound Data

  • Kwon Koo-Joo;Shin Byeong-Seok
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권1호
    • /
    • pp.6-13
    • /
    • 2006
  • Ultrasound visualization is a typical diagnosis method to examine organs, soft tissues and fetus data. It is difficult to visualize ultrasound data because the quality of the data might be degraded by artifact and speckle noise, and gathered with non-linear sampling. Rendering speed is too slow since we can not use additional data structures or procedures in rendering stage. In this paper, we use several visualization methods for fast rendering of ultrasound data. First method, denoted as adaptive ray sampling, is to reduce the number of samples by adjusting sampling interval in empty space. Secondly, we use early ray termination scheme with sufficiently wide sampling interval and low threshold value of opacity during color compositing. Lastly, we use bilinear interpolation instead of trilinear interpolation for sampling in transparent region. We conclude that our method reduces the rendering time without loss of image quality in comparison to the conventional methods.