• Title/Summary/Keyword: Sampling and Transport System

Search Result 39, Processing Time 0.032 seconds

Estimation of optimal price of freeway traffic information using a price-sensitivity analysis (가격민감도 기법을 이용한 고속도로 교통정보의 적정가치 산정 연구)

  • Lee Eui-Eun;Kim Jun-Jung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.2 no.1 s.2
    • /
    • pp.85-92
    • /
    • 2003
  • Due to the expansion of freeway networks in Korea, drivers have more routes to choose. Traffic information on various alternative roadway sections and routes may help drivers choose the optimal route that minimizes travel time or cost. Traffic information on roadways is, therefore, invaluable in sense that individual drivers could reduce their travel time or cost by selecting optimal routes, and furthermore total travel cost of the system could be lowered. However, consensus about the price of traffic information that drivers are willing to pay is not made yet. Current price of traffic information is decided according to the price of similar information such as stock, weather and so on. To investigate the value of traffic information, a survey was conducted at freeway rest areas near Seoul Megalopolis area including Kyunggi Province. Eight hundred drivers who had travelled on freeway within a year were randomly selected. Purposive Quota Sampling was used. A price-response function, a relationship between price and sales, was obtained based on the survey, followed by sensitivity analysis

  • PDF

A Study on Injury Severity Prediction for Car-to-Car Traffic Accidents (차대차 교통사고에 대한 상해 심각도 예측 연구)

  • Ko, Changwan;Kim, Hyeonmin;Jeong, Young-Seon;Kim, Jaehee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.4
    • /
    • pp.13-29
    • /
    • 2020
  • Automobiles have long been an essential part of daily life, but the social costs of car traffic accidents exceed 9% of the national budget of Korea. Hence, it is necessary to establish prevention and response system for car traffic accidents. In order to present a model that can classify and predict the degree of injury in car traffic accidents, we used big data analysis techniques of K-nearest neighbor, logistic regression analysis, naive bayes classifier, decision tree, and ensemble algorithm. The performances of the models were analyzed by using the data on the nationwide traffic accidents over the past three years. In particular, considering the difference in the number of data among the respective injury severity levels, we used down-sampling methods for the group with a large number of samples to enhance the accuracy of the classification of the models and then verified the statistical significance of the models using ANOVA.

Exploring Smoothing Techniques for Reliable Travel-Time Information in Probe-Based Systems (프로브 기반 교통정보 신뢰성 향상을 위한 평활화 기법 탐색)

  • Jang, Jinhwan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.1
    • /
    • pp.79-88
    • /
    • 2018
  • With the increasing popularity of electronic toll collection system using 5.8 GHz dedicated short-range communications (DSRC) technology, DSRC-based travel-time collection systems have been deployed on major urban and rural arterial routes in Korea. However, since probe sample sizes are frequently insufficient in probe-based systems, the gathered travel times from probe vehicles fluctuate significantly compared to those of the population; as a result, the accuracy of the collected travel times could decrease. To mitigate the fluctuations (also known as biases), smoothing techniques need to be applied. In this study, some smoothing techniques-moving average, the Loess, and Savitzky-Golay filtering-were applied to probe travel times. Resultantly, the error in the smoothed travel times at the lowest sampling plan (5%) decreased as much as 45% compared to those in non-smoothed travel times. The results of this study can be practically applied to probe-based travel-time estimation systems for providing reliable travel times along the travel corridor.

Assessment of water quality in an artificial urban canal: A case study of Songdo City in South Korea

  • Ahn, Jungkyu;Na, Yeji;Park, Sung Won
    • Environmental Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.582-590
    • /
    • 2019
  • Currently, the waterfront facility was constructed in New Songdo City, South Korea. It has the various water leisure areas and especially an artificial urban canal with filtered seawater by re-circulating flow system. However, due to excessive amount of nutrients from seawater combined with complicated geometry, it is highly vulnerable to deterioration of water quality. In this study, flow characteristics and pollutant transport were analyzed with comprehensive numerical models, MIKE 3 FM and ECO-lab. Based on these numerical results, notable sampling points were selected for field measurements and comparison between modeling and measured results were conducted. In addition, the integrated water quality evaluation index, Water Quality Index was applied to analyze various water quality issues. We also set up scenarios to control the two kinds of water quality factors, dissolved oxygen (DO), and total phosphorus (TP). As a result, the effect of 20% reduction of TP was less than 10% and it was almost ineffective for a year but it was reduced by up to 40% in case of scenario which DO is increased by 20%. Therefore, it was recommended to control the DO concentration, usually by applying re-aeration facility, rather than TP in artificial urban canal with seawater.

Identification of Culturable Bioaerosols Collected over Dryland in Northwest China: Observation using a Tethered Balloon

  • Chen, Bin;Kobayashi, Fumihisa;Yamada, Maromu;Kim, Yang-Hoon;Iwasaka, Yasunobu;Shi, Guang-Yu
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.3
    • /
    • pp.172-180
    • /
    • 2011
  • The transfer of microorganisms is important process for ecosystems. Microorganisms in dryland can transport itself to wetland through atmospheric diffusion, but only few papers reported about the atmospheric bioaerosol present over dryland. We carried out the direct sampling using a tethered balloon over Dunhuang City, China's northwestern dryland. Bioaerosols were collected using a tethered balloon with a bioaerosol collector at 820 m above the ground (1,960 m above the sea level) around noon on August 17, 2007. The bioaerosols were cultured after the collection at Dunhuang Meteorological observatory. Two strains of molds were isolated using the Nutrient agar medium. About 400-bp 18S rRNA partial sequences were amplified by PCR and determined afterwards. The results of a homology search by 18S rRNA sequences of isolates in DNA databases (GenBank, DDBJ, and EMBL) and an observation of the form revealed that two bioaerosols in the convective mixed layer over Dunhuang City were Cladosporium sp. and Aspergillus sp.

Optimization of a Single-Channel Pump Impeller for Wastewater Treatment

  • Kim, Joon-Hyung;Cho, Bo-Min;Kim, Youn-Sung;Choi, Young-Seok;Kim, Kwang-Yong;Kim, Jin-Hyuk;Cho, Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.4
    • /
    • pp.370-381
    • /
    • 2016
  • As a single-channel pump is used for wastewater treatment, this particular pump type can prevent performance reduction or damage caused by foreign substances. However, the design methods for single-channel pumps are different and more difficult than those for general pumps. In this study, a design optimization method to improve the hydrodynamic performance of a single-channel pump impeller is implemented. Numerical analysis was carried out by solving three-dimensional steady-state incompressible Reynolds-averaged Navier-Stokes equations using the shear stress transport turbulence model. As a state-of-the-art impeller design method, two design variables related to controlling the internal cross-sectional flow area of a single-channel pump impeller were selected for optimization. Efficiency was used as the objective function and was numerically assessed at twelve design points selected by Latin hypercube sampling in the design space. An optimization process based on a radial basis neural network model was conducted systematically, and the performance of the optimum model was finally evaluated through an experimental test. Consequently, the optimum model showed improved performance compared with the base model, and the unstable flow components previously observed in the base model were suppressed remarkably well.

An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

  • Sun, Qiang;Wei, Kexin;Gao, Chenghai;Wang, Shasha;Liang, Bin
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1110-1121
    • /
    • 2016
  • The mathematical model of a three phase PWM converter under the stationary αβ reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.

Preliminary study on colloidal partitioning and speciation of trace metals in acid mine drainage

  • Kwon, Jang-Soon;Lee, Jeong-Ho;Yun, Seong-Taek;Jung, Hun-Bok;Chang, Min-Kyoung;Lee, Pyeong-Ku
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.100-101
    • /
    • 2004
  • Many researches in Korea have been performed to understand the pollution of stream waters by acid mine drainage. However, few studies have been conducted regarding the effect of particulate and colloidal fractions on the transport of trace metals. To estimate harmful effects of trace metals, it is important to evaluate the particulate and colloidal metals as well as dissolved metals, because particulate and colloidal fractions of trace metals play an important role in transport of trace metals and may adversely affect habitats and organisms in riverine system. Colloids are solids with effective diameters in size range from 0.001 $\mu$m to 1 $\mu$m. According to Jone et al. (1974), metals in surface water, like Al, Fe, and Mn, require filtration with pore-size membranes smaller than 0.45 $\mu$m to define dissolved concentrations. The main objective of this study is to understand the effects of particulate, colloidal, and truly dissolved fractions on the transport and fate of trace metals in acid mine drainage. This study was conducted for the Onjeong creek in the Uljin mine area. Sampling was carried out in 13 sites, spatially covering the area from mine dumps to the downstream Onjeong reservoir. To examine the metal partitioning between particulate, colloidal, and truly dissolved fraction, we used successive filtration techniques consisting of conventional method (using 0.45 $\mu$m membranes) and tangential-flow ultrafiltration (using 0.001 $\mu$mm membranes). Ultrafiltration may seperate much smaller particles from aqueous phase (Josephson, 1984; Hernandez and Stallard, 1988). The analysis of metals were performed by inductively coupled plasma - atomic emission spectrometer (ICP-AES: model Perkin Elmer OPTIMA3000XL). Anions such as SO$_4$, Cl and NO$_3$ were measured with ion chromatograph (IC: model Dionex 120). Sample analysis is still in progress. The preliminary data show that the studied creek is severely polluted by Al, Fe, Mn, Pb and Zn. Toward upstream sites with relatively lower pH, less than 50% of Al and Fe occur in the sorbed form on particles or colloids, whereas more than 80% of Al and Fe occur in the sorbed form in downstream sites or tributaries with relatively higher pH. Less than 30% of Zn is present in particle or colloidal forms in the whole range of creek. Truly dissolved fraction of trace metals is negatively correlated with pH. The Kd values for Al, Fe and Zn consistently increase with increasing pH and decrease with increasing particle concentration.

  • PDF

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

Concentration Characteristics and Health Effect Assessment of Atmospheric Particulate Matters During Asian Dust Storm Episodes (황사 에피소드 발생시 대기먼지의 농도 특성과 인체 영향)

  • Kang, Gong-Unn
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.21-35
    • /
    • 2009
  • The Asian dust storms which originated in the deserts of Mongolia and China transported particles to Korea and led to a high concentration of atmospheric particulate matters (PM) of more than $1000{\mu}g/m^3$ throughout the country in the spring, of 2007. Public concern, in Korea, about the possible adverse effects of these dust events has increased, as these dust storms can contain various air pollutants emitted from heavily industrialized eastern China. The objectives of this study were to understand the concentration characteristics of PM as a function of particle size between the Asian dust storm episodes and non-Asian dust period and to consider the mass size distribution of PM in the Asian dust storms and their water soluble ion species on the potential, possible effects on deposition levels in the three regions (nasopharyngeal, tracheobronchial, and alveolar) of the human respiratory system. The size distribution of PM mass concentration during the Asian dust storms showed a peak in the coarse particle region due to the long-range transport of soil particles from the deserts of Mongolia and China, which was identified by HYSPLIT-4 model for backward trajectory analysis of air arriving in the sampling site of Iksan. During the non-Asian dust period, there were two different types in PM size distribution: bimodal distribution when low concentrations of $PM_{2.5}$ were observed, while unimodal distribution having a peak in fine particle region when high concentrations of $PM_{2.5}$ were showed. This unimodal distribution with high concentrations of fine particulate and secondary air pollutants such as ${SO_4}^{2-}$, ${NO_3}^-$, ${NH_4}^+$ was found to be due to the long-range transport of air pollutants from industrialized eastern China. During the Asian dust storms, the mean concentrations of PM that can be deposited in the nasopharyngeal, tracheobronchial, and alveolar region were $128.8{\mu}g/m^3$, $216.5{\mu}g/m^3$, and $89.6{\mu}g/m^3$, respectively. During the non-Asian dust period, the mean concentrations of PM that can be deposited in the nasopharyngeal, tracheobronchial, and alveolar region were $8.4{\mu}g/m^3$, $9.5{\mu}g/m^3$ and $38.5{\mu}g/m^3$, respectively.