자연발생석면지역의 토양 내 석면함유율에 따른 비산석면 농도평가 - 활동근거시료채취방법(ABS)과 실시간 섬유 측정 장치(F-1 fiber monitor) 결과 비교 - (Comparison of Airborne Asbestos Concentrations from Soils in Naturally Occurring Asbestos(NOA) Areas - Activity Based Sampling(ABS) vs. Real-time Asbestos Fiber Monitor(F-1 fiber monitor) -)

  • 장광명;박경훈;최성원;김현욱
    • 한국산업보건학회지
    • /
    • 제27권3호
    • /
    • pp.245-256
    • /
    • 2017
  • Objectives: The present study is aimed at performing real-time measurement of fibrous materials using an F-1 fiber monitor, investigating the correlations between the measurements and environmental conditions, and assessing the feasibility of the use of the monitor in actual exposure assessments based on the accuracy and reliability of the device. Methods: Asbestos specimens with a fixed asbestos content were dispersed in a chamber and collected with a particle measuring test device. Measurements obtained by the existing PCM method, and with the F-1 fiber monitor were compared. In addition, concentrations of asbestos fibers obtained by the PCM method, the TEM method, and the F-1 fiber monitor were compared with that of specific ABS scenarios in NOA regions. Correlations of asbestos contents in soil and weather conditions with each method of measurement were analyzed. Results: Laboratory results showed that levels of asbestos fibers measured with each method increased as fiber contents in soil increased. In the accuracy and reproducibility assessment, no significant differences were found between the different methods of measurement. On-site assessment results showed positive correlations among the methods, and these correlations were less significant compared with what was shown by the laboratory results. Levels of asbestos fibers increased as asbestos contents in soil increased, and as temperature increased. Levels of asbestos fibers decreased as humidity increased, and wind speed did not significantly affect the extent to which asbestos fibers were scattered. Conclusions: While it would be premature to replace existing methods with the use of F-1 fiber monitors in real sites based on the results of this study, the monitor may be useful in the screening of the sites, which assesses hazard levels in different regions. Replacement of existing methods with the use of F-1 fiber monitors may be possible after the limitations identified in this study are overcome, and additional assessment data are obtained and reviewed under different conditions to confirm the reliability of the monitor in future research. Obtained assessment results may be used as basic data for the assessment of asbestos hazard in NOA regions.

DXA측정기 종류에 따른 요추부와 대퇴경부 골밀도 값의 측정오차 비교 (Comparison Measurement Error of T-score Between Lumbar and Femoral Neck According to Kind of DXA)

  • 한범희;정홍량;임청환;이혜남;정천수;이상호
    • 한국콘텐츠학회논문지
    • /
    • 제10권3호
    • /
    • pp.250-257
    • /
    • 2010
  • 본 연구는 골밀도측정기 Norland와 Osteocore, Lunar 세 기종을 이용하여 각각 100명씩 총 300명을 대상으로 신체특징 중 연령, 신장, 체중으로 구분하여 측정오차를 비교분석하였으며, 요추부와 대퇴경부를 각각 정상(T-score$\geqq$-1.0), 골감소증(-1.0>T-score>-2.5), 골다공증(T-score>-2.5)으로 분류하여 각각의 그룹에서 측정오차를 비교분석하여 다음과 같은 결론을 얻었다. 연령과 신장에서 Norland측정기가 측정오차의 변화가 가장 적었으며, 체중에서는 Lunar측정기가 측정오차의 변화가 가장 적은 것으로 나타났다. 또한, 요추부를 기준으로 골밀도 측정오차를 비교한 결과 Lunar, Norland, Osteocore 세 기종 모두 골감소증에서 측정오차의 변화가 가장 적은 것으로 나타났고, 대퇴경부를 기준으로 골밀도 측정오차를 비교한 결과 Lunar, Norland, Osteocore 세 기종 모두 골다공증에서 측정 오차의 변화가 가장 적은 것으로 나타났다. 각 변수에 있어서 기종 마다 측정오차가 다르게 나타났으며, 이를 해결하기 위해서는 표준화된 공통 Phantom을 사용하여 각 회사의 측정치를 환산 비교하고, 소프트웨어의 교체에 따른 상호보정이 필요할 것으로 사료된다.

일반인의 미병 인식 변화 양상과 관리방안 조사 (A study on pattern of changes of Mibyeong recognition, prevalence and its management plan in Korean public : national survey)

  • 이은영;박기현;유종향;이시우
    • 대한예방한의학회지
    • /
    • 제20권1호
    • /
    • pp.1-10
    • /
    • 2016
  • Objectives : The purposes of this study were to investigate the recognition of Mibyeong, symptom, management plan and correlation between quality of life and health condition, and to suggest a plan for managing Mibyeong status. Methods : Participants were recruited based on the same sampling methods used on the previous study performed in 2013 based on area, gender and age. Questionnaires were collected by Gallup Korea professional surveyor through face-to-face interviews. The questionnaires contain questions about the recognition of Mibyeong, symptom, management plan and the quality of life in accordance with the relevant health conditions. Descriptive statistics were used for data analysis and the results were expressed as percentage ratios (%). Results : 1,100 of people were acquired in 2015. The responses for "First time to hear of Mibyeong" have shown that the percentage were reduced from 80% to 67% compared with 2013 data. The ratio of Mibyeong's symptoms in 2015 were similar to 2013. we suggested some ways to deal with the Mibyeong status including behavior adjustment (non smoking, non alcohol, control sleep pattern), herbal tea, health functional food, exercise, preventive health care (qi-gong, yoga), meditation, home health care medical device (hot-pack, seat device for fumigation, massager), and medical service (hospital, medical clinic oriental medical clinic). Almost people showed that positive opinion with them. There were significant correlation between quality of life with the health status rather than Mibyeong or disease group. Conclusions : This study was performed through scientific questionnaires collected in 2013 and 2015 to investigate people's understanding of Mibyeong as a present condition in Korean public. Some questions had significantly different responds between both years while others showed similar trends for both years. These results suggest that the concept of Mibyeong in oriental medicine could provide a management mechanisms that help people to manage the Mibyeong status.

정맥주입요법 간호실무지침 개정 (Updates of Nursing Practice Guideline for Intravenous Infusion)

  • 구미옥;조용애;은영;정인숙;김현림;윤희숙;김은현;윤지현;장희경
    • 임상간호연구
    • /
    • 제23권3호
    • /
    • pp.361-375
    • /
    • 2017
  • Purpose: This study was conducted to update the existing nursing practice guideline for intravenous infusion guidelines according to the evidence-based practice guideline in South Korea. Methods: Guideline update process was performed using 22 steps according to the manuals developed by NICE and SIGN. Results: Updated nursing practice guidelines for the intravenous infusion were consisted of 23 domains and 322 recommendations. The number of recommendations in each domain were 4 for general instruction, 12 for vascular access device selection, 20 for site selection, 9 for insertion, 54 for stabilization, 21 for maintaining patency, 4 for blood sampling, 33 for exchange and removal, 28 for add-on device selection, 28, 72 for infusion related complications, 56 for infusion therapies, 7 for education, and 2 for documentation and report. There were 15.9% of A, 30.2% of B, 53.9% of C in terms of grade recommendations. A total of 178 (51.6%) recommendations were newly developed and 24 previous recommendations have been deleted. Conclusion: Updated nursing practice guideline for intravenous infusion was expected to be an evidence-based practice guideline for intravenous infusion in South Korea. This guideline is suggested to be disseminated to clinical nursing settings nationwide to improve the efficiency of intravenous infusion practice.

보행 시 변형 및 복원이 가능한 인솔에 대한 족저압력 비교 분석 (Comparative Analysis of Foot Pressure Distribution by Functional Insole to be Transformed and Restored During Walking)

  • 박승범;이경득;김대웅;유중현;김경훈
    • 한국운동역학회지
    • /
    • 제21권2호
    • /
    • pp.231-241
    • /
    • 2011
  • The purpose of this study was to analyze the distribution of foot pressure generated by active materials of a functional insole. Comfort is an important consideration while selectingfootwear and insoles. Consequently, it has an influence on injury. The development of new materials for functional insoles is considered one of the more important points for their manufacture. The method adopted in this study is as follows. First, ten healthy males were selected as subjects for the study. Each subject's foof was pre-screened podoscope(Alfoots, Korea) to check for the presence of any foot abnormalities, Two kinds of equipment were used for the study: a foot pressure device from Pedar-X, Germany, and a treadmill from Pulsefitness, UK. Next, each subject was asked to test four types of insoles(insoles of outdoor shoes, indoor shoes, walking shoes, and sports shoes) via walking trials on the treadmill at a constant speed of 4.2 km/h. The pressure distribution data(contact area, maximum force, maximum peak pressure, and maximum mean pressure) was collected using the pressure device at a sampling rate of 100 Hz. Results of the tests showed that all four types of functional insoles increased contact areas whit the foot. Further, functional insoles of walking shoes and sport shoes decreased the foot pressure. From these results, we conclude that the active materials of functional insoles of shoes can increase the contact area and provide greater comfort.

CIELAB 색공간에서 균일한 분포를 갖는 색역사상 참조 테이블 생성 방법 (Generation Method of Color Gamut Mapping Look-up Table Uniformly Selected in the CIELAB Color Space)

  • 오현수;이철희;곽한봉;서봉우;안석출
    • 한국멀티미디어학회논문지
    • /
    • 제4권4호
    • /
    • pp.316-323
    • /
    • 2001
  • 장치간 색변환을 위한 색역사상은 영상의 현색을 향상시키거나 보존하기 위하여 장치사이에 색을 변환하기 위한 방법이다. 색 역사상은 본질적으로 색변환 오차를 발생시키며, 이때 색변환 오차는 색역사상 방법, 원시 및 목적 장치 , 그리고 색역 모델링을 위한 표본점에 의존한다. 모니터와 프린터사이의 색 변환의 경우 각 장치에 대한 모델링을 위해 표본의 측정값에 기초한 경험적인 표기법을 많이 사용한다. 색표본은 CMY 혹은 RGB와 같은 장치 색 공간에서 균일하게 분포된 색표본을 측정해서 사용한다. 그러나, 프린터 표본의 경우 이러한 표본들은 프린터 색역 내부에 균일하게 분포되지 않으므로 색변환 오차가 증가한다. 따라서 본 연구에서는 장치 독립적인 색공간인 CIELAB공간에서 균등하게 분포하는 색표본 생성법을 제안하고 3차원 보간법을 이용한 색변환 실험을 통해 제안된 색표본 생성 방법의 성능을 평가하였다.

  • PDF

선택적 지지면에 따른 스쿼트 운동이 정상 성인의 균형조절능력에 미치는 영향 (The Effect of the Squat Exercise by Different Baseform on Balance Ability Enhancement in Normal Adult)

  • 김민수;서인열;정고운;이건철;정한신
    • 대한통합의학회지
    • /
    • 제1권3호
    • /
    • pp.63-78
    • /
    • 2013
  • PURPOSE : This study aims to investigate the positive correlation in pre-post test design between squat exercise on different baseform and the static/dynamic balance ability enhancement in adults. METHOD : This clinical study was designed into three different random-sampling adult groups (flat, balanced, vibration exercise device) and performed squat exercise. The static/dynamic balance ability was measured prior to the intervention and vice-versa. Balance was examined using the balance master 7.0 version systems. RESULT : 1) After the intervention, the controlled mat group in mCTSIB has showned the minimal mean value and the variation regards as acceptable by statistic value. 2) After the intervention, The mean value of LOS shows the minimal average variation in Randomised Trials, but the other two trials shows the maximal fluctuation. The difference variation regards as acceptable statistic value. 3)After the intervention, the mean value of mat group measrued as the maximal results, the difference variation regards as acceptable statistic value. 4)The striking correlation difference at mCTSIB has found in the vibration device exercise group, but LOS and Rhythmic W-S showed the correaltion in Mat group. CONCLUSION : The study found the positive correlation that enhanced balance ability on the different dynamic baseform squat exercise than static baseform environment. The significant difference found the balance pad squat effects on developing balance ability and the correlationship regards as statistically significant value.

마이크로 컴퓨터를 이용한 식품가공(食品加工) 공정중(工程中)의 온도및 무게 측정용(測定用) Analog-digital 변환(變換)및 접속(接續) 시스템의 제작(製作) (Microcomputer-based Data Acquisition System for the Measurements of Temperature and Weight in Food Processing)

  • 최부돌;전재근
    • 한국식품과학회지
    • /
    • 제19권2호
    • /
    • pp.129-133
    • /
    • 1987
  • 마이크로컴퓨터를 식품가공 공정및 연구에서 자료수집및 제어에 응용하기 위하여 Apple ll 컴퓨터에 접속가능한 접속장치(接續裝置)를 설계 제작하였다. 또한 식품의 여러 공정에 주요한 변수가 되는 온도 및 무게값을 전기적 신호로 감지하는 센서와 A/D변환기(變換器)의 적정 입력전압범위 전환을 위한 증폭회로를 구성하였다. 이들을 연결시켜 필요한 BASIC어(語) 프로그램을 작성하여 식품건조 장치의 온도및 무게값의 측정장치로 활용 가능함을 보였다. 컴퓨터를 응용함으로써 공정자료의 정확성과 신뢰성을 향상시키고 여러가지 공정변수를 다량 수집할 수 있게되고 수집된 많은 자료를 용이하게 저장, 분석할 수 있었다. 본 실험장치에 여러가지 목적에 따라 필요한 측정 센서를 개발하여 부착(附着)함으로 비단 온도와 무게 측정뿐 아니라 제반(諸般)식품(食品)제조 공정과 실험의 자동화에 활용할 수 있는 기초적인 자료를 얻었다.

  • PDF

PDA 기반의 학습 영역 추출을 이용한 강의 영상 디스플레이 기법 (Lecture Video Display Technique using Extraction Region of Study based on PDA)

  • 서정희;박흥복
    • 한국정보통신학회논문지
    • /
    • 제11권11호
    • /
    • pp.2127-2134
    • /
    • 2007
  • 전자적인 학습은 이동성 및 접근의 용이성, 즉시성, 유연성을 제공하여 학습자의 시간적인 제약을 극복할 수 있었으나 유선 컴퓨터상에서 공간에 의한 제약은 많은 문제로 남아있다. 따라서 이런 전자적인 학습은 학습자에게 시간과 공간적인 제약을 극복할 수 있는 모바일 학습 환경으로 변화하는 추세이다. 그러나 모바일 디바이스들은 작은 디스플레이 사이즈로 인하여 실시간 동영상에서 제공되는 학습 내용을 정확하게 인식하기는 어려운 실정이다. 따라서 본 논문은 실시간 학습 영상을 관심 영역에 대한 학습 영역을 추출하고 작은 디스플레이 디바이스 사이즈에 적절한 영상 크기로 축소하여 무선 PDA에 디스플레이하는 기법을 제안한다. 실험 결과, 다양한 강의 영상에서 학습 내용 중심의 영역을 적응적으로 추출하고, 사용자 디바이스 사이즈에 적합한 영역을 효과적으로 계산함으로써 계산에 소요되는 시간을 크게 줄일 수 있었다.

고성능 AC-DC 변환기를 이용한 저전압 진동에너지 하베스팅 회로 (A Low-voltage Vibrational Energy Harvesting Circuit using a High-performance AC-DC converter)

  • 공효상;한장호;최진욱;윤은정;유종근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.533-536
    • /
    • 2016
  • 본 논문에서는 진동 에너지를 이용한 MPPT 제어기능을 갖는 에너지 하베스팅 회로를 설계하였다. Body-bias technique과 bulk-driven technique을 이용하여 저전압에서도 높은 효율특성을 갖는 고성능 AC-DC 변환기를 제안하고 진동에너지 하베스팅 회로 설계에 적용하였다. MPPT (Maximum Power Point Tracking) 제어는 진동소자의 개방회로전압과 MPP 전압간의 관계를 이용하였으며, 진동소자의 개방회로전압을 주기적으로 샘플링 함으로써 이를 이용해 MPPT 기준전압을 생성하고, 이를 기준으로 부하로의 에너지 공급을 제어한다. $0.35{\mu}m$ CMOS 공정으로 설계된 회로의 칩 면적은 $1.21mm{\times}0.98mm$이다.

  • PDF